Lighting for walkways shall be as given below:
a) Lighting should illuminate the walkway; lighting fixtures not exceeding a height of 4 m from ground level should be provided.
b) Lighting shall be provided every 20 m to 30m, focusing light not on the car lanes, but on the walkways.
c) A white light source, for example high-pressure sodium, is preferable in city and town centres for the aesthetic effect and for better colour definition, which benefits those with poor sight.
d) White lighting at average 35 to 40 lux is recommended to ensure colour contrast of tactile blocks and to ensure visibility at night to persons with low vision.
e) Light pole may preferably be located within the tree-planting zone.
f) Lower level light poles are preferred to avoid shadow where there are high trees.

Key
1 Minimum 2100 mm clear height
2 Guardrail against impact, at a height 680 - 700 mm above floor
3 Guardrail detectable with cane, at a maximum height above floor
All dimensions in millimetres.
FIG. 35 WARNING GUARDRAIL IN CASE OF INSUFFICIENT HEADROOM