7 REINFORCED BRICK AND REINFORCED BRICK CONCRETE FLOORS AND ROOFS
The construction and design of reinforced brick and reinforced brick concrete floors and roof shall be in accordance with good practices [6-4(7)].
8 SPECIAL CONSIDERATION FROM EARTHQUAKE POINT OF VIEW
8.0 Special features of design and construction for earthquake resistant masonry buildings are given in 8.2 to 8.8.2. However, special features of design and construction for improving earthquake resistance of low strength masonry buildings is covered in 9.
8.1 For the purpose of 8 and 9, the definitions given below shall apply in addition to those given in 2.
8.1.1 Separation Section — A gap of specified width
between adjacent buildings or parts of the same building either left uncovered or covered suitably to permit movement in order to avoid pounding due to earthquake.
8.1.1.1 Crumple section — The separation gap filled with appropriate material that crumples or factures in the event of an earthquake.
8.1.2 Centre of Rigidity — The point in a structure where application of lateral force produces equal deflections of its components at any level in any particular direction.
8.1.3 Shear Wall — A wall designed to resist lateral force in the own plane. Braced frames, subjected primarily to axial stresses, shall be considered as shear walls for the purpose of this definition.
8.1.4 Space Frame — A three-dimensional structural system comprised of interconnected members, without shear or bearing walls, so that to function as a complete self-contained unit with or without the aid of horizontal diaphragms or floor bracing systems.
8.1.4.1 Vertical load carrying frame — A space frame designed to carry all the vertical loads, the horizontal loads being resisted by shear walls.
8.1.4.2 Moment resistant frame — A space frame capable of carrying all vertical and horizontal loads, by developing bending moments in the members and at joints.
8.1.4.3 Moment resistant frame with shear walls — A space frame with moment resistant joints and strengthened by shear walls to assist in carrying horizontal loads.
8.1.5 Box System — A bearing wall structure without a space frame, the horizontal forces being resisted by the walls that act as shear walls.
8.1.6 Band — A reinforced concrete or reinforced brick runner provided in the walls to tie them together and to impart horizontal bending strength in them.
NOTE — For low strength masonry buildings, wooden runners may also be used as runner.
8.1.7 Seismic Zone and Seismic Coefficient — The Seismic Zones II to IV as classified in 5 of Part 6 'Structural Design, Section 1 Loads, Forces and Effects' of the Code and corresponding basic seismic coefficient αo as specified in 3.4 of good practice [6-4(8)].
8.1.8 Design Horizontal Seismic Coefficient — The value of horizontal seismic coefficient Ah computed taking into account the soil-foundation system and the importance factor as specified in 6.4 of good practice [6-4(9)].
8.1.9 Concrete Grades — 28 day compressive strength
of concrete cubes of 150mm size, in MPa; for example, for Grade M20 as per good practice[6-4(10)], the characteristic compressive strength equals to 20MPa.
8.1.10 Zone Factor (Z) — It is a factor to obtain the design spectrum depending on the perceived maximum seismic risk characterized by maximum considered earthquake (MCE) in the zone in which the structure is located.