NBC 2016 (SP 7:2016) Volume 1
2016 · PDF page 790
Hover any section to copy its link or text, ask Copilot about it, or bookmark it.
1.1 This Code (Part 6/Subsection 5A) deals with the general structural use of plain and reinforced concrete.
1.1.1 For the purpose of this Subsection, plain concrete structures are those where reinforcement, if provided is ignored for determination of strength of the structure.
1.2 Special requirements of structures, such as shells, folded plates, arches, chimneys, blast resistant structures, hydraulic structures, liquid retaining structures and earthquake resistant structures, covered in respective Indian Standards, have not been covered in this Subsection; these Indian Standards shall be used in conjunction with this Subsection. See good practices [6-5A(1)].
For the purpose of this Subsection, the definitions given in accepted standards [6-5A(2)] shall apply.
For the purpose of this Subsection, the following letter symbols shall have the meaning indicated against each; where other symbols are used, they are explained at the appropriate place:
A — Area
— Breadth of beam, or shorter dimension of
a rectangular column
— Effective width of slab
— Effective width of flange
— Breadth of web or rib
D — Overall depth of beam or slab or diameter of column; dimension of a rectangular column in the direction under consideration
— Thickness of flange
DL — Dead load
— Effective depth of beam or slab
— Depth of compression reinforcement from the highly compressed face
— Modulus of elasticity of concrete
EL — Earthquake load
— Modulus of elasticity of steel
e — Eccentricity
PART 6 STRUCTURAL DESIGN — SECTION 5 CONCRETE: 5A PLAIN AND REINFORCED CONCRETE
s — Spacing of stirrups or standard deviation
— Distributed dead load per unit area
— Distributed imposed load per unit area
— Percentage reduction in moment
— Permissible stress in concrete in bending compression
— Permissible stress in concrete in direct compression
— Permissible stress in metal in direct compression
— Permissible stress in steel in compression
— Permissible stress in steel in tension
— Permissible stress in shear reinforcement
— Design bond stress
— Shear stress in concrete
— Maximum shear stress in concrete with shear reinforcement
— Nominal shear stress
— Diameter of bar
The cement used shall be any of the following conforming to accepted standards [6-5A(3)] and the type selected should be appropriate for the intended use:
a) Ordinary Portland cement,
b) Rapid-hardening Portland cement,
c) Portland slag cement,
d) Portland pozzolana cement (fly ash based),
e) Portland pozzolana cement (calcined clay based),
f) Hydrophobic cement,
g) Low heat Portland cement, and
h) Sulphate resisting Portland cement.
Other combinations of Portland cement with mineral admixture (see 4.2) of quality conforming with relevant Indian Standards laid down may also be used in the manufacture of concrete provided that there are satisfactory data on their suitability, such as performance test on concrete containing them.
4.1.1 Low heat Portland cement conforming to accepted standards [6-5A(4)] shall be used with adequate precautions with regard to removal of formwork, etc.
4.1.2 High alumina cement conforming to accepted standard [6-5A(5)] or supersulphated cement conforming to accepted standard [6-5A(6)] may be used only under special circumstances with the prior approval of the Engineer-in-Charge. Specialist literature may be consulted for guidance regarding the use of these types of cements.
4.1.3 The attention of the Engineer-in-Charge and users of cement is drawn to the fact that quality of various cements mentioned in 4.1 is to be determined on the basis of its conformity to the performance characteristics given in the respective Indian Standard specification for that cement. Any trade-mark or any trade name indicating any special features not covered in the standard or any qualification or other special performance characteristics sometimes claimed/indicated on the bags or containers or in advertisements alongside the ‘Statutory Quality Marking’ or otherwise have no relation whatsoever with the characteristics guaranteed by the Quality Marking as relevant to that cement. Consumers are, therefore, advised to go by the characteristics as given in the corresponding Indian Standard Specification or seek specialist advice to avoid any problem in concrete making and construction.