J-4.4.1 Warning signs posted on entrances to the trainway and on fences or barriers adjacent to the trainway
should clearly state the hazard (for example, DANGER: HIGH VOLTAGE, 25 000 V) with letter sizes and colours in conformance with requirements of Metro Railway Rules.
J-4.4.2 System egress points should be illuminated.
J-4.4.3 Points of exit from elevated and enclosed trainways should be marked with internally or externally illuminated signs.
J-4.4.4 Tunnel lighting should be 100 percent on emergency power source, that is, UPS. Minimum illumination of 10 lux should be maintained on tunnel egress routes. Emergency lighting should be powered from a source independent of that supplying the normal lighting.