J-4.1.1 The system should incorporate a walking surface or other approved means for passengers to evacuate a train at any point along the trainway so that they can proceed to the nearest station or other point of safety.
J-4.1.2 Walkway continuity should be maintained at special track sections like cross over or pocket tracks. Walkway continuity should be provided by cross walks at track level.
J-4.1.3 Within enclosed trainways, the maximum distance between emergency exits/exit stairways should not exceed 750 m.
J-4.1.4 For trainways in twin bore tunnels or trainways in a tunnel divided by a minimum 120 min fire rated wall separation, cross-passageways should be permitted to be used in-lieu of emergency exit stairways.
J-4.1.5 Where cross passageways are utilized in-lieu of emergency exit stairways, the following requirements should apply:
a) First cross-passageway should be provided not farther than 500 m from the end of platform of an enclosed station or from the tunnel portal or from a mid-tunnel exit way.
b) Distance between any two cross-passageways should not be more than 250 m.
c) The crossover in an enclosed trainway should be considered as cross-passageway. The distance between crossover and subsequent cross-passageway should not be more than 250 m.
d) Cross-passageways should be separated from each trainway with separate self-closing fire door assemblies having a fire protection rating of minimum 90 min.
e) A tenable environment should be maintained in the portion of the trainway that is not involved in an emergency and that is being used for evacuation.
f) A ventilation system for the incident trainway should be designed to control smoke in the vicinity of the passengers.
g) Provisions should be made for evacuating passengers via the non-incident trainway to a nearby station or other emergency exit.
h) The provisions should include measures to protect passengers evacuating from non-incident tunnel from oncoming traffic and from other hazards.
j) Where cross-passageways are used in-lieu of emergency exit stairways, the interior of the cross-passage should not be used for any purpose other than as an area of refuge or for access/egress to the opposite tunnel, except for installation of non-combustible equipment inside the cross passageways, provided that such equipment does not infringe the required clear space of the cross-passage.