Under the WBP method, lighting systems are a very important part of overall building performance for most non-residential building types. Any lighting system efficiency improvements or reductions are reflected as energy savings in the WBP method. The description of lighting systems in building energy simulation models must incorporate the following two characteristics:
Application of a lighting power density (LPD) for each space or thermal zone of the building model. This may be determined using one of the two methods defined in §6.3.2 (building area method) or §6.3.3 (space function method).
An operational schedule for the lighting system which describes the percentage of the maximum LPD value that is energized during a particular hour.
There are further requirements if the electric lighting system is to be controlled in response to the amount of daylight in perimeter zones of the building. In such cases, the building simulation program must be able to explicitly model daylight levels in each perimeter space that has daylight linking. Light sensors must be modeled in these zones, and a control strategy must be applied that modulates electrical energy output from the electric lighting system. Typically there are at least three daylight linked control schemes to modulate electrical energy output:
Stepped control: in this control scheme, the electrical lighting system can respond to the presence of daylight in defined steps
• Linear control: the lighting system modulates it’s output in a linear function to a prescribed minimum level, and
Linear/off: the lighting system modulates it’s output in a linear function and will switch off (use zero electrical energy) when there is sufficient daylight in the space
Either the building area or space function method may be used, but the categorization of spaces must be identical between the Standard Design and the Proposed Design.
The LPD for the Proposed Design is taken from the design documents for the building. If a lighting system already exists, then the lighting system design for Proposed Design will be based on the actual lighting power density of the
existing system. In the special case where no lighting system or design exists, as in a shell building where the lighting will be installed by a future tenant, then a default lighting power density must be assumed, based on the building area method for the appropriate building type. If no building type is known, then an office building is assumed.
Exterior lighting systems as defined in ECBC §6.2.1.4 shall contain lamps having a minimum efficacy of 80 lm/W unless, the luminaire is controlled by a motion sensor or is and emergency lighting
Hvac
Incorporating HVAC systems into whole building energy simulation models is a complex process. It requires knowledge of how buildings respond to climate, in addition to knowledge of the configuration of HVAC systems and appropriate control strategies. For the purpose of building energy simulation it is useful to think of the building model as having three HVAC type components - ZONES, SYSTEMS and PLANT.