AC Induction motors are the most commonly used prime mover for various equipment in buildings.
In these motors, the induced magnetic field of the stator winding induces a current in the rotor. This rotor current produces a second magnetic field, which tries to oppose the stator magnetic field, and this causes the rotor to rotate.
Although induction motors are normally considered fixed speed machines, one potential disadvantage is that their operating speed will change with both load and voltage. In fact, it is difficult to find two induction motors that will operate at exactly the same speed, even when operated at identical voltage and frequency, and driving identical loads.
Induction motors can be constructed so that different pole pairs can be connected and disconnected as desired at the terminal box, producing a variety of speeds. Such squirrel-cage induction motors are multispeed (usually two speed), but are not variable-speed if operating from a supply at fixed frequency. In another variation, part-winding start induction motors energize part of the winding when starting and the rest later, in one or more steps, so as to reduce starting torque or current
Induction motor can also be classified into the following types based on the type of rotor:
a) Squirrel cage motor
b) Slip ring or wound rotor motor.
The 3-phase squirrel cage induction motor is the workhorse of most applications; it is rugged and reliable, and is by far the most common motor type used. These motors drive pumps, blowers and fans, compressors, conveyers and production lines. The 3-phase induction motor has three windings each connected to a separate phase of the power supply.