The following codes, programs, and policies will take precedence over the Code in case of conflict:
(a) Any policy notified as taking precedence over this Code, or any other rules on safety,
Reference Standards
The National Building Code of India 2016 (NBC) is the reference standard for lighting levels, heating, ventilating, and air conditioning (HVAC), thermal comfort conditions, natural ventilation, and any other building materials and system design criteria addressed in this Code.
Building Classification
There are many different types of commercial buildings that fall under the purview of the Code. These buildings are different from each other in basic typology, usage of spaces and occupancy. For example, a school is fundamentally a different kind of building compared to a hotel which is again very different compared to an office. Hence, the Code has requirements for different kind of buildings.
Energy efficiency requirements for the Code were derived after analysing 16 different non-residential building typologies, that in turn are broadly based on building classification in the National Building Code of India. Spatial layouts, material specifications, façade characteristics,
and occupancy patterns have an impact on energy efficiency of a building and differ for these typologies.
Potential for reducing energy use with technology and materials thus varies from building type to type. By analysing this potential, ECBC energy efficiency requirements are now sensitive to building typologies and, to the extent possible, only requirements that are feasible have been included.
Any one or more building or part of a building with commercial use is classified as per the functional requirements of its design, construction, and use. The key classification is as below:
(a) Hospitality: Any building in which sleeping accommodation is provided for commercial purposes, except any building classified under Health Care. Buildings and structures under Hospitality shall include the following:
i. No-star Hotels – like Lodging-houses, dormitories, no-star hotels/motels
ii. Resort
iii. Star Hotel
(b) Health Care: Any building or part thereof, which is used for purposes such as medical or other treatment or care of persons suffering from physical or mental illness, disease, or infirmity; care of infants, convalescents, or aged persons, and for penal or correctional detention in which the liberty of the inmates is restricted. Health Care buildings ordinarily provide sleeping accommodation for the occupants. Buildings and structures like hospitals, sanatoria, outpatient healthcare, laboratories, research establishments, and test houses are included under this type.
(c) Assembly: Any building or part of a building, where number of persons congregate or
gather for amusement, recreation, social, religious, patriotic, civil, travel and similar purposes. Buildings like theatres or motion picture halls, gathering halls, and transport buildings like airports, railway stations, bus stations, and underground and elevated mass rapid transit system are included in this group.
(d) Business: Any building or part thereof which is used for transaction of business, for keeping of accounts and records and similar purposes, professional establishments, and service facilities. There are two subcategories under Business – Daytime Business and 24-hour Business. Unless otherwise mentioned, Business buildings shall include both Daytime and 24-hour subcategories.
(e) Educational: Any building used for schools, colleges, universities, and other training institutions for day-care purposes involving assembly for instruction, education, or recreation for students. If residential accommodation is provided in the schools, colleges, or universities or coaching/ training institution, that portion of occupancy shall be classified as a No-star Hotel. Buildings and structures under Educational shall include following types-
i. Schools
ii. Colleges
iii. Universities
iv. Training Institutions
(f) Shopping Complex: Any building or part thereof, which is used as shops, stores, market, for display and sale of merchandise, either wholesale or retail. Buildings like shopping malls, stand-alone retails, open gallery malls, super markets, or hyper markets are included in this type.
(g) Mixed-use Building: In a mixed-use building, each commercial part of a building must be classified separately, and –
If a part of the mixed-use building has different classification and is less than 10% of the total above grade floor area, the mixed-use building shall show compliance based on the building subclassification having higher percentage of above grade floor area.
ii. If a part of the mixed-use building has different classification and one or more sub-classification is more than 10% of the total above grade floor area, the compliance requirements for each subclassification, having area more than 10% of above grade floor area of a mixed-use building shall be determined by the requirements for the respective building classification in §4 to §7.
Any building which does not fall under any of the categories defined above shall be classified in a category mentioned above that best describes the function of the building.
Example 2-A
A new airport is coming up in a city. What building typology will it be considered for ECBC compliance?
As per §2.5, the airport will be classified as an ‘Assembly’ building type.
Example 2-B
A university campus has the following buildings.
Library
Hostel blocks
Faculty housing
Engineering college
Sports complex
Identify which buildings are applicable for ECBC compliance
All buildings on this campus are applicable for ECBC compliance. The hostel blocks and faculty housing, although are residential, but they are intended for a commercial purpose. These buildings are not considered as private residence. Hence will be applicable for Code compliance.
Example 2-C
A project having a built-up area of 100,000 sqm includes the following types of buildings
• 2 storey shopping complex
• 3 storey mall
• 10 storey office block
4 blocks of 15 storey residential buildings
Will this project be applicable for Code compliance? Identify the building typology as per the Code for this project.
The residential buildings in the project are considered as a ‘private residence’. Hence, they are not included in the scope of ECBC. All remaining buildings are applicable for Code compliance.
This project will be classified as a ‘mixeduse Building’ as per §2.5 where individual buildings will be classified as follows.
2 storey shopping complex – Shopping complex
• 3 storey mall – shopping complex
• 10 storey office block - Business
Each of these buildings will have to comply with the requirements for the specific building type as per the Code.
Compliance and Approach
This section enumerates the overall compliance and administrative requirements for demonstrating compliance with the Code. The technical requirements are covered in detail in the subsequent chapters.
SECTION ORGANIZATION
COMPLIANCE
APPROACH
MEET MANDATORY REQUIREMENTS
PRESCRIPTIVE METHOD
DETERMINE EPI RATIOS
BUILDING ENVELOPE TRADE-OFF METHOD
WHOLE BUILDNG PERFORMANCE METHOD
3.COMPLIANCE and Approach