The Whole Building Performance Method is an alternative to the Prescriptive Method compliance path contained in §4 through §7 of this Code. It applies to all building types covered by the Code as mentioned in §2.5.
In general, the WBP Method may be used to show compliance with the ECBC for any project at the designer’s discretion, subject to the following caveats and exceptions. Specifically, WBP Method may be used when some individual components of the Proposed Building do not meet the prescriptive requirements of the Code,
but the remaining components far exceed the Code requirements. The latter, then, ‘compensate’ for the lower performance of the former components, and the building may Code considering its overall energy use.
It must be noted here that mandatory provisions of the Code must be met at all times, while using the WBP Method as well. For example, if the WWR of the Proposed Building exceeds 40%, compliance cannot be demonstrated using the prescriptive requirements. The WBP Method may be used, wherein other more efficient components of the building may make up for increased WWR.
WHILE USING THE WBP METHOD, MANDATORY PROVISIONS OF THE CODE MUST BE MET AT ALL TIMES
No HVAC System
Use of the WBP method requires knowledge of the proposed HVAC system in order to create the Standard Design. Buildings with no HVAC system cannot use the WBP Method. In the case of a shell building, which might become conditioned in the future, trade-offs may still be made within the envelope system.
Alterations to Existing Buildings
When the WBP method is used for an alteration of an existing building, some special rules apply. The WBP method is optional for this purpose;
designers may use the calculation acceptable to the Authority Having Jurisdiction. Unless a building component is being altered, the Proposed Design and the Standard Design are identical for that component. Portions of the building that are being replaced shall be treated as new systems and these systems in the Standard Design shall be representative of the requirements in the ECBC.