Compliance shall be documented, and compliance forms shall be submitted to the authority having jurisdiction. The information submitted shall include, at a minimum, the following:
a) Summary describing the results of the analysis, including the annual energy use for the Proposed Design and the Standard Design, and software used.
b) Brief description of the project with location, number of stories, space types, conditioned and unconditioned areas, hours of operation.
c) List of the energy-related building features of the Proposed Design. This list shall also
document features different from the Standard Design.
d) List showing compliance with the mandatory requirements of this code.
e) The input and output report(s) from the simulation program including a breakdown of energy usage by at least the following components: lights, internal equipment loads, service water heating equipment, space heating equipment, space cooling and heat rejection equipment, fans, and other HVAC equipment (such as pumps). The output reports shall also show the number of hours any loads are not met by the HVAC system for both the Proposed Design and Standard Design.
f) Explanation of any significant modelling assumptions made.
g) Explanation of any error messages noted in the simulation program output.
h) Building floor plans, building elevations, and site plan.
All requirements of §Error! Reference source not found., §Error! Reference source not found., §Error! Reference source not found., and §Error! Reference source not found. shall be met. These sections contain the mandatory provisions of the Code and are prerequisites for demonstrating compliance using the WBP Method.
Simulation Requirements