In another iteration (called the Standard Design), parameters of the Proposed Design are modified according to the rules specified in Table 9-1. Unless specified in this table, all building systems and equipment are modeled identically in the Standard Design and Proposed Design. The Proposed Design and Standard are simulated for all 8,760 hours of a year using the hourly values of climatic data, such as temperature and humidity, from representative climatic data for the city in which the Proposed Design is to be located. For cities or urban regions with several climate data entries, and for locations where weather data are not available, weather data that best represents the climate at the construction site may be selected. EPIs for the Standard Design and Proposed Design are
obtained from the output file of the models (the equations are included below).