A key task in modeling the Proposed Design is assigning space use classifications to different areas of the building. These classifications are used to assign lighting power density assumptions and to differentiate areas within the building that may have different operating schedules and characteristics (thermostat settings, ventilation rates, etc.). The choice of space use classifications is taken from one of the two lighting tables in the ECBC: either Table 6-1 Interior Lighting Power for ECBC Buildings – Building Area Method or Table 6-4 Interior Lighting Power for ECBC Buildings – Space Function Method. The designer may choose
either classification scheme but may not mix the schemes by using one for part of the building and the other for the rest of the building. “Building,” in this context, refers to the space encompassed by a single building permit application, which may be less than the complete building.
The secondary support areas associated with each of the major building types would be included in each building type. For example, if a building included both office and retail areas, the corridors and restrooms associated with the office occupancy would be included in the office area and the storage or/and dressing room areas associated with the sales floor would be included in the retail area.