Using efficient lighting equipment and controls is the best way to ensure lighting energy efficiency while maintaining or even improving lighting conditions. For instance, modern fluorescent lighting, such as electronically ballasted T-8 systems, can provide the same quantity of light as older fluorescent lighting while consuming as little as two-thirds of the energy. Similarly, compact fluorescent sources are three to four times more efficient than the traditional incandescent lamps they are designed to replace.
For a lighting designer an energy-efficient lighting design involves sensitive integration of many requirements and considerations that include building orientation, interior building layout, task illumination, daylight strategies, glazing specification, choice of lighting system and controls etc. The designer is also responsible for making sure that lighting complies with the Code, meeting both mandatory and prescriptive requirements. As per the Code,
Lighting systems and equipment shall comply with the mandatory provisions of §6.2 and the prescriptive criteria of §6.3. The lighting requirements in this section shall apply to:
(a) Interior spaces of buildings,
(b) Exterior building features, including facades, illuminated roofs, architectural features, entrances, exits, loading docks, and illuminated canopies, and,
(c) Exterior building grounds lighting that is provided through the building's electrical service.
Exceptions to §6.1:
(a) Emergency lighting that is automatically off during normal building operations.
The mandatory requirements for lighting mostly relate to interior and exterior lighting controls.