The WBP Method provides a detailed and robust analysis of the thermal performance of building. Whole building energy simulation is currently the most sophisticated way of analyzing the impact of energy efficiency measures in an integrated manner. It is an alternative to the prescriptive requirements contained in §4 to §8 of ECBC. The impact of changing any one of the myriad parameters affecting energy performance of the building design being modeled can be predicted using this method. This is particularly useful for studying the impact of combinations of energy efficiency measures that may lead to non-linear building energy outcomes.
For example, electric lights produce light and heat inside a space. Calculating the electrical consumption for the electric lights is not very difficult, as long as one knows how many lights there are, what their heat output is, and how many hours they run. One does not need a simulation model to predict this outcome. However, the heat generated by electric lighting has to be removed by the HVAC systems in a warm or hot climate. Calculating the reduction in energy used by the HVAC systems due to the use of a more efficient electric lighting system is not recommended through manual calculations.
This computation becomes significantly more complex if the design team decides to employ a daylight linked electric lighting system. Such a system is designed to reduce light (and heat output) in a space when enough daylight is available. This non-linear relationship impacts the electric energy input to the lighting system, and the heat removed by the HVAC system.
(see 3.1.1 Energy Performance Index)
(see 3.1.2 Determining EPI Ratio)
At this time, predicting the integrated energy performance resulting from complex energy efficiency strategies cannot be studied reliably by any other means except the use of a whole building energy simulation analysis.
Once the model is completed and a base run is established, carrying out multiple runs to test alternate design options involves less effort on the part of the analyst, although there could still be substantial computer run time involved. Whole building energy simulation is increasingly being used for testing compliance with various building energy codes and sustainability rating tools such as LEED and GRIHA. Technically reliable and verifiable energy simulation programs satisfying the minimum modeling capabilities (specified in §9.3 below) should be used for compliance using this verification method.