This Part 3 of the code covers the requirements for electrical installations for special purposes and at special locations. It can also be classified as electrical installations in non-industrial buildings. The requirements for electrical installations in industrial buildings has been detailed in Part 4 of the code. While a majority of installations could be categorically classified as non- industrial, an industrial complex would necessarily incorporate sub-units such as offices, residential quarters and support services which are either housed or fall in the category of non-industrial buildings. The requirement stipulated in Part 3 and Part 4 of this Code would therefore require judicious application.
With the current trend in power utilization, it would also be extremely difficult to classify electrical installations based on power requirement or the voltage of supply, as large buildings for non-industrial purposes consume sufficient power to consider them at par with the consumption of light industrial establishments. It is therefore necessary to consider for initial assessment of the installation the guidelines given in Part 1/Sec 8 this Code, which are better defined than the earlier terminology used for classifying installations. Also, this part specifies the requirements for installations in certain special purposes like supplies for electrical vehicles and furniture that require special attention for safety and ease of usability.
Part 3 of this Code, therefore covers requirements for several types of special applications and non-industrial occupations. In case of typical occupancies that strictly fall into any of these, recourse shall be made to the general guidelines stipulated in Part 1.
This Part consists of the following Sections:
Section 1 Domestic dwellings
Section 2 Locations containing a bath or shower
Section 3 Swimming pools and fountains
Section 4 Rooms and cabins containing sauna heaters
Section 5 Construction and demolition site installations
Section 6 Conducting locations with restricted movement
Section 7 Caravan parks, camping parks and similar locations
Section 8 Marinas and similar locations
Section 9 Medical locations
Section 10 Exhibitions, shows and stands
Section 11 Furniture
Section 12 Extra-low-voltage lighting installations
Section 13 Community facilities and workplaces
Section 14 Electrical installations in caravans and motor caravans
Section 15 Supplies for electric vehicles
Section 16 Operating or maintenance gangways
Section 17 Temporary electrical installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses
Section 18 Heating cables and embedded heating systems
Section 19 Office building, shopping and commercial centres and institutions
Section 20 Hotels
Section 21 Sports buildings
Section 22 Specific requirements for electrical installations in multistoried buildings
Domestic Dwellings
This section will give guidelines particularly in respect of Electrical Installations in Domestic Dwellings. The portion in this section shall be read with Part 1 Section 9 Wiring Installations. The recommendations given here under are to call for specific attention primarily to provide safe electrical environment from the point of view of users having no age band, who are uninstructed, with whom one cannot expect to have any technical knowledge and capability to identify possible electrical threats/hazards. Another point to consider is designing layouts, selecting fittings in respect of lighting, ventilation, power outlets to suite needs of such users at home; not for any particular period of day like office hours but for round the clock, which will provide comfort, ease of operation and convenience.