4.1 Escalators are desirable where the movement of people, in large numbers at a controlled rate in the minimum of space, is involved, for example, railway stations, shopping centres/malls, airports, etc. These encourage people to circulate freely and conveniently. Inclined moving walks are preferable where trolley movement is expected between levels, like department stores, airport, etc.
Typically, horizontal moving walks are used where medium to long distance travel is involved such as airports/metro stations/exhibition halls.
4.2 As the escalators and moving walks operate at a constant speed, serve only two levels and have a known maximum capacity, the traffic study is rather easy, provided the population to be handled in a given time is known. It is easy to predict the rate at which the population can be handled.
Figure 1 shows the brief idea about the steps to be followed for arriving at appropriate escalator and moving walk solution for particular application.
Based on Fig. 1, type and location of building, expected population, and the serving floor details are required to work on the preliminary traffic analysis for escalators and moving walks.
For normal peak periods, the recommended handling capacities for design purposes should be taken as indicated in Table 1. The handling capacity of escalator also depends on the angle of inclination, speed, step widths and the areas at the boarding and alighting levels.
| Sl No.(1) | Duty Category(2) | Typical Usage(Passengers/Day)(3) | Typical Locations(4) |
|---|---|---|---|
| i) | Light | Up to 4 000 | Shops, leisure facilities, multiplexes |
| ii) | Medium | Up to 10 000 | Department stores, shopping centres, domestic airports and railway stations |
| iii) | Heavy | Up to 20 000 | Railway (junctions), metro stations, airports |
| iv) | Intensive | Over 20 000 | Major railway (junctions), metro stations, international airports |
4.3 The number of persons that may be theoretically carried by the escalators and moving walks in 1h is given in Table 2 and Table 3, respectively.
| Sl No. | Step Width m | Theoretical Capacity, in Persons/h | ||
| For 0.5 m/s Speed (3) | For 0.65 m/s Speed (4) | For 0.75 m/s Speed (5) | ||
| (1) | (2) | |||
| i) | 0.6 | 4 500 | 5 850 | 6 750 |
| ii) | 0.8 | 6 750 | 8 775 | 10 125 |
| iii) | 1.0 | 9 000 | 11 700 | 13 500 |
4.4 Though 4.3 indicates the theoretical values for escalators (see Table 2) and moving walks (see Table 3), Tables 4 and 5 indicate the practical values to be considered while calculating the required number of escalators and moving walks (based on traffic flow pattern).