2.1 General Terms Relating to Escalators and Moving Walks
2.1.1 Angle of Inclination — Maximum angle to the horizontal in which the steps, the pallets or the belt move.
2.1.2 Auxiliary Brake — Fail safe brake, which is used to stop an escalators/moving walk under all normal conditions or under certain fault conditions only, typically situated on one side of the main drive shaft.
2.1.3 Balustrade — Part of the escalator/moving walk which ensures the user's safety by providing stability, protecting from moving parts and supporting the handrail.
2.1.4 Balustrade Decking — Transverse member of the balustrade which meets the handrail guidance profile and which forms the top cover of the balustrade.
2.1.5 Brake Load — Load on the step/pallet/belt for which the brake system is designed to stop the escalator/moving walk.
2.1.6 Comb — Pronged section at each landing that meshes with the grooves of the steps
2.1.7 Comb Lighting — Small flush light panels located in the skirt panels on both sides of the escalators/moving walk unit at both upper and lower landing and immediately adjacent to the comb teeth to illuminate the comb and step tread and assist passengers boarding and alighting the escalators/moving walk.
2.1.8 Comb Plate — Platform at each landing to which the combs are attached.
2.1.9 Comb Plate Switch — Switch in safety circuit that opens when excessive force is detected in vertical and/or horizontal direction on the comb or comb plate of escalators/moving walk.
2.1.10 Comb Teeth — Series of teeth which ride the grooves of the escalators/moving walk step tread as the step passes underneath and are designed so as to allow them to break off, if a wedging action should occur at their point of contact with step tread.
2.1.11 Emergency Brake — Auxiliary mechanically automatically operated brake, which will stop a fully loaded escalator, if the drive chain breaks.
2.1.12 Emergency Stop Switch — Separate stop button usually located in adjacent walls, columns or within the balustrade providing the facility to stop the escalator/moving walk, in the event of emergency.
2.1.13 Inspection Door — Means of access to equipment areas and other spaces pertaining to an escalators/moving walk installation such as machinery spaces, etc, and with access usually restricted to authorized persons.
2.1.14 Safety Devices — Part of a safety circuit consisting of safety switches and/or fail safe circuits.
2.1.15 Escalator — Power-driven, inclined, continuous moving stairway used for raising or lowering persons in which the user carrying surface (for example, steps) remains horizontal.
NOTE — Escalators are machines, and even when out of operation, shall not be considered as fixed staircases as there could be a safety concern.
2.1.16 Exterior Panel — Part of the exterior side of the enclosure of an escalator or moving walk.
2.1.17 Handrail — Power-driven moving rail for persons to grip while using the escalator or moving walk.
2.1.18 Interior Panel — Panel located between the skirting or lower inner decking and the handrail guidance profile or balustrade decking.
2.1.19 Lower Inner Decking — Profile that connects
the skirting with the interior panel when they do not meet at a common point.
2.1.20 Lower Outer Decking — Profile that connects the exterior panels with the interior panel.
2.1.21 Machinery — Escalator or moving walk machine(s) mechanisms and associated equipment.
2.1.22 Machinery Spaces — Space(s) inside or outside of the truss where the machinery as a whole or in parts is placed.
2.1.23 Maximum Capacity — Maximum flow of persons that can be achieved under operational conditions.
2.1.24 Moving Walk — Power-driven installation for the conveyance of persons in which the surface carrying the users remains parallel to its direction of motion and is uninterrupted (for example, pallets, belt).
NOTE — Moving walks are machines, and even when out of operation, shall not be considered as fixed access as there could be a safety concern.
2.1.25 Newel — End of the balustrade.
2.1.26 Nominal/Rated Speed — Speed in the direction of the moving steps, pallets or the belt stated by the manufacturer for which the escalator or moving walk has been designed, without load on the steps/pallets/belt at nominal frequency and nominal voltage.
2.1.27 Pit — Recess in the floor to receive that portion of the lower landing and the lower end of the incline section which occurs below the floor line when there is no floor under the escalator such as in a basement.
2.1.28 Rated Load — Load which the equipment is designed to move.
2.1.29 Rise (Travel) — Vertical distance between the upper and lower finished floor levels.
2.1.30 Safety Circuit — Part of the electric safety system consisting of electrical safety devices.
2.1.31 Skirting — Vertical part of the balustrade interfacing with the steps, pallets or belt.
2.1.32 Skirt Deflector — Device to minimize the risk of trapping between the step and the skirting.
2.2 Terms Related to Performance Requirements of Escalators and Moving Walks
2.2.1 Acceleration — Rate of change of velocity. It is expressed in m/s² .
2.2.2 Background Noise Correction ( K1A ) — Correction term to account for the influence of background noise on the emission sound pressure level at the specified positions of the machine under test.
NOTE — The correction in the case of A-weighting is to be determined from A-weighted measured values.
2.2.3 Emission Sound Pressure Level ( LpA ) — A-weighted sound pressure level at the specified positions, excluding the effects of background noise and contribution due to the room characteristics (reverberation) of the in-situ environment. It is expressed in decibel.
2.2.4 Environmental Indicator ( K2A )—Correction term to account for the influence of reflected sound on the emission sound pressure level due the characteristic of the test room.
2.2.5 Equivalent Sound Pressure Level ( LpAeq ) — Average A-weighted sound pressure level.
2.2.6 Load Carrying Unit — Part of an escalator or moving walk designed to carry persons for the purpose of transportation. For example, step, pallet or belt.
2.2.7 Measured Speed — Speed of the escalator or moving walk with no load measured at the time of testing after the starting sequence has been completed.
2.2.8 Ride Quality — Sound levels and vibration of the steps/pallet, relevant to passenger perception, associated with escalator or moving walk operation.
2.2.9 Sound Pressure Level ( Lp ) — Ten times the logarithm to the base 10 of the ratio of the square of the sound pressure to the square of the reference sound pressure.
NOTE — The reference sound pressure level is 20 µ Pa (2 × 10-5 Pa) .
2.2.10 Velocity — Rate of change of displacement. Velocity is reported as speed and direction of travel. It is given in metre per second (m/s).