For the purpose of this Section, the definitions given below shall apply.
2.1 Ambient Noise — The sound pressure levels associated with a given environment. Ambient noise is usually a composite of sounds from near and far sources, none of which are particularly dominant.
2.2 Audible Frequency Range — The range of sound frequencies normally heard by the human ear. The audible range spans from 20 Hz to 20 000 Hz.
2.3 A-Weighted Sound Pressure, pA — Value of overall sound pressure, measured in pascal (Pa), after the electrical signal derived from a microphone has been passed through an A-weighting network.
NOTE — The A-weighting network modifies the electrical response of a sound level meter with frequency in approximately the same way as the sensitivity of the human hearing system.
2.4 A-Weighted Sound Pressure Level, LpA — The quantity of A-weighted sound pressure, in decibel (dB), as given by the following formula:
where
pA = A-weighted sound pressure, in pascals (Pa); and
p₀ = reference sound pressure (20µ Pa)
NOTE — Measurements of A-weighted sound pressure level can be made with a meter and correlate roughly with subjective assessments of loudness, and are usually made to assist in judging the effects of noise on people. The size of A-weighting in 1/3 octave bands, is shown in Annex A (see A-5). An increase or decrease in level of 10 dBA corresponds roughly to a doubling or halving of loudness.
2.5 Background Noise — The sound pressure levels in a given environment from all sources excluding a specific sound source being investigated or measured.
2.6 Break-In — Unwanted sound transmission into a duct or a quiet environment, from outside.
2.7 Break-Out — Unwanted sound transmission from the inside of a duct or a noisy enclosure, to the outside.
2.8 Broad Band Noise — Spectrum consisting of a large number of frequency components, none of which is individually dominant.
2.9 Cross-Talk — Unwanted sound transmission between one room and another room or space, via a duct.
2.10 Ctr — Correction term applied against the sound insulation single-number values ( Rw , Dw , and DnT,w ) to provide A-weighting against low frequency performance.
NOTE — The reference values used within the Ctr calculation are based on urban traffic noise.
2.11 Decibel — Ten times the logarithm (to the base 10) of the ratio of two mean square values of sound pressure, sound power or sound intensity. The abbreviation for decibel is dB.
2.12 Effective Perceived Noise Level, in Decibel (EPN dB) — The number for rating the noise of an individual aircraft flying overhead is the effective perceived noise level in decibel (EPN dB). The effective perceived noise decibel value takes into account the subjectively annoying effects of the noise including pure tones and duration. In principle, it is a kind of time-integrated loudness level.
2.13 Equivalent Continuous A-Weighted Sound Pressure Level, LAeq.T — Value of the A-weighted sound pressure level in decibel (dB) of a continuous, steady sound, that within a specified time interval, T, has the same mean squared sound pressure as the sound under consideration that varies with time, and is given by the formula:
where
pA(t) = instantaneous A-weighted sound pressure, in pascal (Pa); and
p₀ = reference sound pressure (20 μPa).
NOTE — Equivalent continuous A-weighted sound pressure level is mainly used for the assessment of environmental noise and occupational noise exposure.
2.14 Equivalent Sound Absorption Area of a Room, A — Hypothetical area of a totally absorbing surface without diffraction effects, expressed in square metre (m²) which, if it were the only absorbing element
in the room, would give the same reverberation time as the room under consideration.
2.15 Façade Level — Sound pressure level measured 1 m to 2 m in front of the façade.
NOTE — Façade level measurements of LpA are usually 2 dB to 3 dB higher than corresponding free-field measurements.
2.16 Free-Field Level — Sound pressure level measured outside, far away from reflecting surfaces.
NOTE — Measurements made 1.2 m to 1.5 m above the ground and at least 3.5 m away from other reflecting surfaces are usually regarded as being free-field measurements. To minimise the effect of reflections the measuring position should be at least 3.5 m to the side of the reflecting surface (that is, not 3.5 m from the reflecting surface in the direction of the source). Estimates of noise from aircraft overhead usually include a correction of 2 dB to allow for reflections from the ground.
2.17 Frequency — The number of cyclical variations per unit time. Frequency is generally expressed in cycles per second (cps) and is also denoted as Hertz (Hz).
2.18 Impact Sound Pressure Level, Li — Average sound pressure level in a specific frequency band in a room below a floor, when it is excited by a standard tapping machine.
2.19 Indoor Ambient Noise — Pervasive noise in a given situation at a given time, usually composed of noise from many sources, inside and outside the building, but excluding noise from activities of the occupants.
2.20 Insertion Loss ( LIL ) — Insertion loss is generally defined as the difference, in decibels, between two sound pressure levels (or power levels or intensity levels) which are measured at the same point in space before and after a muffler or any other noise control device is inserted between the measurement point and the noise source.
2.21 Noise — Unwanted sound which may be hazardous to health, interferes with communications or is disturbing.
2.22 Noise Exposure Forecast (NEF) — The noise exposure forecast at any location is the summation of the noise levels in EPN dB from all aircraft types, on all runways, suitably weighted for the number of operations during day time and night time.
2.23 Noise Criteria — Numerical indices used to define design goals for the maximum allowable noise in a given space.
2.24 Noise Rating (NR) — Graphical method for rating a noise by comparing the noise spectrum with a family of noise rating curves.
NOTE — Noise rating is described in Annex C.
2.25 Noise Reduction Coefficient (NRC) — A single figure descriptor of the sound absorption property of a material. It is the arithmetic mean of the sound absorption coefficients at 250, 500, 1 000 and 2 000 Hz rounded off to the nearest multiple of 0.05.
2.26 Normalized Impact Sound Pressure Level, Ln — Impact sound pressure level normalized for a standard absorption area in the receiving room.
NOTE — Normalized impact sound pressure level is usually used to characterize the insulation of a floor in a laboratory against impact sound in a stated frequency band (see Annex B).
2.27 Octave Band — Band of frequencies in which the upper limit of the band is twice the frequency of the lower limit.
2.28 Percentile Level, LAN,T — A-weighted sound pressure level obtained using time-weighting 'F', which is exceeded for N percent of a specified time interval.
Example:
LA90,1h is the A-weighted level exceeded for 90 percent of 1h.
NOTE — Percentile levels, determined over a certain time interval cannot accurately be extrapolated to other time intervals. Time-weighting ‘F’ or ‘S’ can be selected on most modern measuring instruments and used to determine the speed at which the instrument responds to changes in the amplitude of the signal. Time-weighting ‘F’ is faster than ‘S’ and so its use can lead to higher values when rapidly changing signals are measured.
2.29 Pink Noise — Sound with an uninterrupted frequency spectrum and a power which is steady within frequency band and proportional to centre frequency. An example is constant power level per octave band.
2.30 Pure Tone — A sound emitted at a single frequency.
2.31 Rating Level, LAr, Tr — Equivalent continuous A-weighted sound pressure level of the noise, plus any adjustment for the characteristic features of the noise.
NOTE — This definition is used for rating industrial noise, where the noise is the specific noise from the source under investigation.
2.32 Reverberation Time, T — Time that would be required for the sound pressure level to decrease by 60 dB after the sound source has stopped.
NOTE — Reverberation time is usually measured in octave or third octave bands. It is not necessary to measure the decay over the full 60 dB range. The decay measured over the range 5 dB to 35 dB below the initial level is denoted by T₃₀ , and over the range 5 dB to 25 dB below the initial level by T₂₀ .
2.33 Sound — A vibrational disturbance, exciting hearing mechanisms, transmitted in a predictable manner determined by the medium through which it propagates. To be audible the disturbance shall have to
fall within the frequency range of 20 Hz to 20 000 Hz.
2.34 Sound Exposure Level, LAE — Level of a sound, of 1 s duration, that has the same sound energy as the actual noise event considered.
NOTES
1 The LAE of a discrete noise event is given by the formula:
where
pA(t) = instantaneous A-weighted sound pressure, in pascal (Pa);
t₂-t₁= stated time interval in seconds (s) long enough to encompass all significant sound energy of the event;
p₀ = reference sound pressure level (20µ Pa) ; and
t₀ = reference time interval (1 s).
2 LAE is also known as LAX (single-event noise exposure level).
2.35 Sound Level Difference, D — Difference between the sound pressure level in the source room and the sound pressure level in the receiving room.
NOTE — D is given by the following formula:
D = L ₁ - L ₂
where
L₁ = average sound pressure level in the source room; and
L₂ = average sound pressure level in the receiving room.
2.36 Sound Power — The acoustic power of a sound source, expressed in Watt.
2.37 Sound Power Level ( Lw ) — The acoustic power radiated from a given sound source as related to a reference power level (typically 10-12 watt) and expressed in decibel as :
where
W = acoustic power, in watt.
By definition, 1W therefore corresponds to 120 dB for Lw.
2.38 Sound Pressure, p — Root-mean-square value of the variation in air pressure measured in pascal (Pa), above and below atmospheric pressure, caused by the sound.
2.39 Sound Pressure Level, Lp — Quantity of sound pressure, in decibel (dB), given by the formula:
where
p = root mean square sound pressure in pascals (Pa); and
p₀ = reference sound pressure (20µ Pa)
NOTE — The range of sound pressures for ordinary sounds is very wide. The use of decibels gives a smaller, more convenient range of numbers. For example, sound pressure levels ranging from 40 dB to 94 dB correspond to sound pressures ranging from 0.002 Pa to 1 Pa. A doubling of sound energy corresponds to an increase in level of 3 dB.
2.40 Sound Receiver — One or more observation points at which sound is evaluated or measured. The effect of sound on an individual receiver is usually evaluated by measurements near the ear or close to the body.
2.41 Sound Reduction Index, R — Laboratory measure of the sound insulating properties of a material or building element in a stated frequency band.
NOTE — For further information see Annex B.
2.42 Sound Source — Equipment or phenomena which generate sound. Source room is the room containing sound source.
2.43 Spectrum — A quantity expressed as a function of frequency, such as sound pressure versus frequency curve.
2.44 Standardized Impact Sound Pressure Level, LnT' — Impact sound pressure level normalized to that in a receiving room having a reverberation time of 0.5 s.
NOTE — Standardized impact sound pressure level is used to characterize the insulation of floors in buildings against impact sound in a stated frequency band (see Annex B).
2.45 Speech Interference Level (SIL) — A descriptor for rating steady noise according to its ability to interfere with conversation between two people. SIL is the arithmetic average of the sound pressure levels in the three octave bands with centre frequencies at 500, 1 000 and 2 000 Hz.
2.46 Standardized Level Difference, DnT — Difference in sound level between a pair of rooms, in a stated frequency band, normalized to a reverberation time of 0.5 s.
NOTE — Standardized level difference takes account of all sound transmission paths between the rooms (see Annex B).