2.4.1 Design Acceleration ( ad ) — The horizontal acceleration to be used for calculation of forces (moments acting on lift systems and arising from seismic events).
NOTE — The value of (ad) shall be obtained by the lift manufacturer from the building engineer/structural engineer.
2.4.2 Normal Operation — Operation mode in which the lift performs when not in seismic mode or in seismic stand-by mode.
2.4.3 Retaining Device — Mechanical device securely fixed to a structural member of the lift car, counterweight frame designed to retain the lift car and counterweight within its guide rails during seismic activity.
2.4.4 Seismic Mode — Special mode in which the lift operates after detection of seismic trigger level.
2.4.5 Seismic Stand-By Mode — Special mode in which the lift operates after detection of primary earthquake wave without the activation of the seismic detection system.
2.4.6 Seismic Trigger Level — Seismic acceleration which is used to activate a seismic detection system.
2.4.7 Snag Point — The point of interference between flexible elements (for example, ropes, chains, travelling cable, etc) and fixed elements (for example, by guide rail brackets, guide rail clip bolts, fishplates, vanes, and similar devices).