Heat transmittance through a surface by conduction, convection, and radiation is expressed by its U-value. U-value is the amount of heat transferred that is lost or gained due to a temperature differential of 1 K through 1 m². The rate of heat transfer (U-value) is minimised by the use of double glazing, using gas inside cavity or by using low-E glass for inside pane of double glazed unit.
The U-value requirement for the glazing system should be selected in accordance with the Table 13 and Annex A.
| Sl No. | λnm(2) | S<sub>λ </sub>Δ λ(3) |
|---|---|---|
| i) | 300 | 0 |
| ii) | 305 | 0.001 859 |
| iii) | 310 | 0.007 665 |
| iv) | 315 | 0.017 961 |
| v) | 320 | 0.029 732 |
| vi) | 325 | 0.042 466 |
| vii) | 330 | 0.062 108 |
| viii) | 335 | 0.065 462 |
| ix) | 340 | 0.071 020 |
| x) | 345 | 0.073 326 |
| xi) | 350 | 0.079 330 |
| xii) | 355 | 0.082 894 |
| xiii) | 360 | 0.087 039 |
| xiv) | 365 | 0.097 963 |
| xv) | 370 | 0.108 987 |
| xvi) | 375 | 0.113 837 |
| xvii) | 380 | 0.058 351 |
NOTE — The values in this table are calculated according to the trapezoidal rule.
| Sl No.(1) | Name of the Shading Device(2) | Transmittance,U-Value(3) | Shade Factor(4) |
| i) | Plain glass sheet (3.0 mm thick) | 5.23 | 1.00 |
| ii) | Plain glass + Wire mesh outside | 5.00 | 0.65 |
| iii) | Painted glass:a) White paintb) Yellow paintc) Green paint | 5.225.225.22 | 0.350.370.40 |
| iv) | Heat absorbing glass | 4.65 | 0.45 |
| v) | Plain glass sheet + Venetian blind inside:a) Light colourb) Dark colour | 3.14 | 0.350.40 |
| vi) | Plain glass sheet which is,a) 100 percent shadedb) 75 percent shadedc) 60 percent shaded | 5.23 | 0.140.340.56 |
| NOTE — Indicative values, actual value of the system to be measured using either approved simulation software or testing laboratory | |||