2.62 Leading Imposed Load — Imposed load causing higher action and/or deflection.
2.63 Limit State — Any limiting condition beyond which the structure ceases to fulfill its intended function (see also 2.86).
2.64 Live Load — See 2.59.
2.65 Load — An externally applied force or action (see also 2.4).
2.66 Main Member — A structural member, which is primarily responsible for carrying and distributing the applied load or action.
2.67 Mill Tolerance — Amount of variation allowed from the nominal dimensions and geometry, with respect to cross-sectional area, non-parallelism of flanges, and out of straightness such as sweep or camber, in a product, as manufactured in a steel mill.
2.68 Normal Stress — Stress component acting normal to the face, plane or section.
2.69 Partial Safety Factor — The factor normally greater than unity by which either the loads (actions) are multiplied or the resistances are divided to obtain the design values.
2.70 Period of Structural Adequacy under Fire — The time (t), in minutes, for the member to reach the limit state of structural inadequacy in a standard fire test.
2.71 Permissible Stress — When a structure is being designed by the working stress method, the maximum stress that is permitted to be experienced in elements, members or structures under the nominal/service load (action).
2.72 Pitch — The centre-to-centre distance between individual fasteners in a line, in the direction of load/stress.
2.73 Plastic Collapse — The failure stage at which sufficient number of plastic hinges have formed due to the loads (actions) in a structure leading to a failure mechanism.
2.74 Plastic Design — Design against the limit state of plastic collapse.
2.75 Plastic Hinge — A yielding zone with significant inelastic rotation, which forms in a member, when the plastic moment is reached at a section.
2.76 Plastic Moment — Moment capacity of a cross-section when the entire cross-section has yielded due to bending moment.
2.77 Plastic Section — Cross-section, which can develop a plastic hinge and sustain plastic moment over sufficient plastic rotation required for formation of plastic failure mechanism of the member or structure.
2.78 Poisson's Ratio — It is the absolute value of the ratio of lateral strain to longitudinal strain under uniaxial loading.
2.79 Proof Stress — The stress to which high strength friction grip (HSFG) bolts are pre-tensioned.
2.80 Proof Testing — The application of test loads to a structure, sub-structure, member or connection to ascertain the structural characteristics of only that specific unit.
2.81 Prototype Testing — Testing of structure, substructure, members or connections to ascertain the structural characteristics of that class of structures, substructures, members or connections that are nominally identical (full scale) to the units tested.
2.82 Prying Force — Additional tensile force developed in a bolt as a result of the flexing of a connection component such as a beam end plate or leg of an angle.
2.83 Rotation — The change in angle at a joint between the original orientation of two linear member and their final position under loading.
2.84 Secondary Member — Member which is provided for overall stability and or for restraining the main members from buckling or similar modes of failure.
2.85 Semi-Compact Section — Cross-section, which can attain the yield moment, but not the plastic moment before failure by plate buckling.
2.86 Serviceability Limit State — A limit state of acceptable service condition exceedance of which causes serviceability failure.
2.87 Shear Force — The in-plane force at any transverse cross-section of a straight member of a column or beam.
2.88 Shear Lag — The in plane shear deformation effect by which concentrated forces tangential to the surface of a plate gets distributed over the entire section perpendicular to the load over a finite length of the plate along the direction of the load.
2.89 Shear Stress — The stress component acting parallel to a face, plane or cross-section.
2.90 Slender Section — Cross-section in which the elements buckle locally before reaching yield moment.
2.91 Slenderness Ratio — The ratio of the effective length of a member to the radius of gyration of the Cross-section about the axis under consideration.
2.92 Slip Resistance — Limit shear that can be applied in a friction grip connection before slip occurs.
2.93 S-N Curve — The curve defining the relationship between the number of stress cycles to failure ( Nsc ) at a constant stress range ( Sc ), during fatigue loading of a structure.
2.94 Snow Load — Load on a structure due to the accumulation of snow and ice on surfaces such as roof.
2.95 Snug Tight — The tightness of a bolt achieved by a few impacts of an impact wrench or by the full effort of a person using a standard spanner.
2.96 Stability Limit State — A limit state corresponding to the loss of static equilibrium of a structure by excessive deflection transverse to the direction of predominant loads.
2.97 Stickability — The ability of the fire protection system to remain in place as the member deflects under load during a fire test.
2.98 Stiffener — An element used to retain or prevent the out-of-plane deformations of plates.
2.99 Strain — Deformation per unit length or unit angle.
2.100 Strain Hardening — The phenomenon of increase in stress with increase in strain beyond yielding.
2.101 Strength — Resistance to failure by yielding or buckling.
2.102 Strength Limit State — A limit state of collapse or loss of structural integrity.
2.103 Stress — The internal force per unit area of the original cross-section.
2.104 Stress Analysis — The analysis of the internal force and stress condition in an element, member or structure.
2.105 Stress Cycle Counting — Sum of individual stress cycles from stress history arrived at using any rational method.
2.106 Stress Range — Algebraic difference between two extremes of stresses in a cycle of loading.
2.107 Stress Spectrum — Histogram of stress cycles produced by a nominal loading event design spectrum, during design life.
2.108 Structural Adequacy for Fire — The ability of the member to carry the test load exposed to the standard fire test.
2.109 Structural Analysis — The analysis of stress, strain, and deflection characteristics of a structure.
2.110 Strut — A compression member, which may be oriented in any direction.
2.111 Sway — The lateral deflection of a frame.
2.112 Sway Member — A member in which the transverse displacement of one end, relative to the other is not effectively prevented.
2.113 Tensile Stress — The characteristic stress corresponding to rupture in tension, specified for the grade of steel in the appropriate Indian Standard, as listed in Table 1.
2.114 Test Load — The factored load, equivalent to a specified load combination appropriate for the type of test being performed.
2.115 Transverse — Direction along the stronger axes of the cross-section of the member.
2.116 Ultimate Limit State — The state which, if exceeded can cause collapse of a part or the whole of the structure.
2.117 Ultimate Stress — See 2.113.
2.118 Wind Loads — Load experienced by member or structure due to wind pressure acting on the surfaces.
2.119 Yield Stress — The characteristic stress of the material in tension before the elastic limit of the material is exceeded, as specified in the appropriate Indian Standard, as listed in Table 1.