BUREAU OF INDIAN STANDARDS
- FOREWORD
- ... 3
- 1 SCOPE
- ... 7
- 2 DEAD LOAD
- ... 7
- 3 IMPOSED LOAD
- ... 7
- 4 WIND LOAD
- ... 18
- 5 SEISMIC FORCE
- ... 64
- 6 SNOW LOAD
- ... 92
- 7 SPECIAL LOADS
- ... 95
- 8 LOAD COMBINATIONS
- ...101
- 9 MULTI-HAZARD RISK IN VARIOUS DISTRICTS OF INDIA
- ...101
- ANNEX A ILLUSTRATIVE EXAMPLE SHOWING REDUCTION OF UNIFORMLY DISTRIBUTED IMPOSED FLOOR LOADS IN MULTI-STOREYED BUILDINGS FOR DESIGN OF COLUMNS
- ...103
- ANNEX B NOTATIONS
- ...104
- ANNEX C BASIC WIND SPEED AT 10 m HEIGHT FOR SOME IMPORTANT CITIES/TOWNS
- ...105
- ANNEX D CHANGES IN TERRAIN CATEGORIES
- ...106
- ANNEX E EFFECT OF A CLIFF OR ESCARPMENT ON EQUIVALENT HEIGHT ABOVE GROUND (K₃ FACTOR)
- ...108
- ANNEX F WIND FORCE ON CIRCULAR SECTIONS
- ...111
- ANNEX G SYMBOLS
- ...112
- ANNEX H MSK 1964 INTENSITY SCALE
- ...113
- ANNEX J SIMPLIFIED PROCEDURE FOR EVALUATION OF LIQUEFACTION POTENTIAL
- ...115
- ANNEX K LIST OF SOME IMPORTANT TOWNS AND THEIR SEISMIC ZONE FACTOR (Z)
- ...120
- ANNEX L SHAPE COEFFICIENTS FOR MULTILEVEL ROOFS
- ...121
- ANNEX M VIBRATIONS IN BUILDINGS
- ...122
- ANNEX N BLAST LOAD
- ...123
- ANNEX P SUMMARY OF DISTRICTS HAVING SUBSTANTIAL MULTI-HAZARD RISK AREAS
- ...130
- LIST OF STANDARDS
- ...131
This Code (Part 6/Section 1) covers the various loads, forces and effects which are to be taken into account for structural design of buildings. The various loads that are covered under this Section are dead load, imposed load, wind load, seismic force, snow load, special loads and load combinations.
This Code was first published in 1970 and subsequently revised in 1983 and 2005. The first revision of this Section was modified in 1987 through Amendment No. 2 to the 1983 version of the Code to bring this Section in line with the latest revised loading code. Thereafter, in view of the revision of the important Indian Standard on earthquake resistant design of structure, that is, IS 1893 a need to revise this part was felt again. The second revision of 2005 was therefore formulated to take into account the revised standard, IS 1893 (Part 1): 2002 'Criteria for earthquake resistant design of structures: Part 1 General provision and buildings (fifth revision)' and to also incorporate latest information on additional loads, forces and effects as also the details regarding multi-hazard risk in various districts of India.
The significant changes incorporated in the second revision of 2005 included: the revision of the seismic zone map providing only four zones, instead of five, with erstwhile Zone I being merged into Zone II; changing of the values of seismic zone factors to reflect more realistic values of effective peak ground acceleration considering Maximum Considered Earthquake (MCE) and service life of structure in each seismic zone; specifying of response spectra for three types of founding strata, namely rock and hard soil, medium soil and soft soil; the revision of empirical expression for estimating the fundamental natural period Ta of multistoreyed buildings with regular moment resisting frames; adoption of the procedure of first calculating the actual force that may be experienced by the structure during the probable maximum earthquake, if it were to remain elastic, also bringing in the concept of response reduction due to ductile deformation or frictional energy dissipation in the cracks by introducing the 'response reduction factor' in place of the earlier performance factor; specifying a lower bound for the design base shear of buildings, based on empirical estimate of the fundamental natural period Ta; deletion of the soil-foundation system factor and instead, introduction of a clause to restrict the use of foundations vulnerable to differential settlements in severe seismic zones; revision of torsional eccentricity values upwards in view of serious damages observed in buildings with irregular plans; revision of modal combination rule in dynamic analysis of buildings; inclusion of a new clause on multi-hazard risk in various districts of India and a list of districts identified as multi-hazard prone districts; incorporation of latest amendments issued to IS 875; introduction of a clause on vibration in buildings for general guidance; and inclusion of reference to the Indian Standards on landslide control and design of retaining walls which were formulated after the first revision of the Section.
In this revision, following significant modifications/inclusions taking into account the recent developments, R & D efforts nationally and internationally, have been made:
-
Provisions on parapets and balustrades have been updated by including concentrated horizontal loads, wherever applicable, and modification in horizontal load per unit length. Also, new use areas covering appurtenances fixed to the structure have been included.
-
Aerodynamic roughness heights for individual terrain categories have been explicitly included, and are used to derive turbulence intensity and mean hourly wind speed profiles.
-
The previous classification of structures into B and C Classes has been deleted and accordingly the modification factor, k₂ is renamed as terrain roughness and height factor.
-
The values of k₂ factor corresponding to previous Class A type structure only, are retained in this Section.
-
An additional modification factor, k₄, termed as importance factor has been included for cyclonic regions.
-
Simple empirical expressions have been suggested for height variations of hourly mean wind speed and also turbulence intensity in different terrains.
-
Provisions to account for effects of directionality, area averaging and correlation of pressures on the design wind pressure have been included.
-
Guidelines to account for the wind induced interference for tall buildings and buildings less than 20m
have been included for use in preliminary design. It is however recommended to carry out detailed boundary layer wind tunnel tests/computational fluid dynamics (CFD) studies for final design of important structures.
-
In the gust factor method for evaluating along wind response, equations have been suggested for background factor, size reduction factor, energy ratio and length scale of turbulence.
-
A method for computing across wind response of tall buildings and lattice towers has been included.
-
The basic wind speed map of India has been updated based on the R&D studies in the country.
-
Provisions relating to design imposed load due to helipad have been included.
-
Provisions related to design imposed load due to fire tenders and emergency vehicle have been included.
-
Provisions relating to loads due to collision between vehicle and structural and non-structural elements in car parking and stilts.
-
Design spectra are defined for natural period up to 6 s.
-
Same design response spectra are specified for all buildings, irrespective of the material of construction.
-
Bases of various load combinations to be considered have been made consistent for earthquake effects, with those specified in the other codes.
-
Temporary structures are brought under the purview of this Section.
-
Importance factor provisions have been modified to introduce intermediate importance category of buildings, to acknowledge the density of occupancy of buildings.
-
A provision is introduced to ensure that all buildings are designed for at least a minimum lateral force.
-
Buildings with flat slabs are brought under the purview of this Section.
-
Additional clarity is brought in on how to handle different types of irregularity of structural system.
-
Effect of masonry infill walls has been included in analysis and design of frame buildings.
-
Method is introduced for arriving at the approximate natural period of buildings with basements, step back buildings and buildings on hill slopes.
-
Torsional provisions are simplified.
-
Provisions relating to simplified method of evaluation of liquefaction potential have been included in Annex J.
-
Provisions relating to design for blast loads have been included in Annex N.
There has been a growing awareness among the consultants, academicians, researchers and practice engineers for design and construction of wind sensitive structures. In order to augment the available limited good quality meteorological wind data and structural response data, it is necessary to conduct full scale measurements in the field. Thus as emphasized in the previous revision, all individuals and organizations responsible for putting up of tall structures are encouraged to provide instrumentation in their existing and new structures (transmission towers, chimneys, cooling towers, buildings, etc) at different elevations (at least at two levels) to continuously measure and monitor wind data. The instruments are required to collect data on wind direction, wind speed and structural response of the structure due to wind (with the help of accelerometer, strain gauges, etc). Such instrumentation in tall structures shall not in any way affect or alter the functional behaviour of such structures. The data so collected shall be very valuable in evolving more accurate wind loading of structures.
The information contained in this Section is largely based on the following Indian Standards:
IS 875 Code of practice for design loads (other than earthquake) for building and structure:
(Part 2): 1987 Imposed loads (second revision)
(Part 3): 2015 Wind loads (third revision)
(Part 4): 1987 Snow loads (second revision)
(Part 5): 1987 Special loads and load combinations (second revision)
IS 1893 (Part 1): 2016 Criteria for earthquake resistant design of structures: Part 1 General provisions and buildings (sixth revision)
This Section has to be read together with Sections 2 to 8 of Part 6 ‘Structural Design’ of this Code.
A special publication, SP 64 (S&T): 2001 ‘Explanatory Handbook on Indian Standard Code of Practice for Design Loads (Other than Earthquake) for Buildings and Structures IS 875 (Part 3): 1987’ is also available. This publication gives detailed background information on the provisions for wind loads and also the use of these provisions for arriving at the wind loads on buildings and structures while evaluating their structural safety.
However, in view of revision of IS 875 (Part 3) in 2015, applicability of this revised standard and this Section of the Code shall be taken as final in case of conflict of provisions with SP 64.
Reference may also be made to the Vulnerability Atlas of India, 2011 and Landslide Hazard Zonation Map of India, 2003 by Building Materials and Technology Promotion Council, Ministry of Urban Development and Poverty Alleviation, Government of India. The Vulnerability Atlas contains information pertaining to each State and Union Territory of India, on (a) seismic hazard map, (b) cyclone, and wind map, (c) flood prone area map, and (d) housing stock vulnerability table for each district indicating for each house type the level of risk to which it could be subjected. The Atlas can be used to identify areas in each district of the country which are prone to high risk from more than one hazard. The information will be useful in establishing the need of developing housing designs to resist the combination of such hazards.
In the formulation of this Section, inputs were also derived from the Heliport Manual, 1995 of the International Civil Aviation Organization.
For guidelines on risk reduction against tsunami for buildings and structures which are near-shore and on-shore within the expected run-up zone of the tsunami, reference may be made to the Indian Standard ‘Guidelines for Risk Reduction of Structures against Tsunami’ (under preparation). The standard deals also with the strategies for protection against tsunami and the design of structures located on coastal sites and in addition, includes special criteria for design of buildings that are to be used for vertical evacuation during a tsunami.
For criteria on structural safety of tall reinforced concrete (RC) buildings of heights greater than 45 m and less than 250 m, normally intended for use as residential, office and other commercial buildings, reference may be made to the Indian Standard ‘Criteria for Structural Safety of Tall Buildings’ (under preparation).
All standards, whether given herein above or cross-referred to in the main text of this Section, are subject to revision. The parties to agreement based on this Section are encouraged to investigate the possibility of applying the most recent editions of the standards.
For the purpose of deciding whether a particular requirement of this Section is complied with, the final value observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance with IS 2 : 1960 ‘Rules for rounding of numerical values (revised)’. The number of significant places retained in the rounded off value should be the same as that of the specified value in this Section.
Section 1 Loads, Forces and Effects