This Part deals with the development control rules and general building requirements to ensure health and safety of the public.
The land use classification may be as indicated below:
| Sl No. | Level 1 | Level 2 | ||||||
| N¹⁾ | A-N²⁾ | Use Category | Colour Code3),4) | Colour Code Description | N | A-N | Use Zone | |
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
| i) | 1 | R | Residential | Yellow | 11 | R-1 | Primary residential zone | |
| 12 | R-2 | Unplanned/Informal residential zone | ||||||
| ii) | 2 | C | Commercial | Red | 21 | C-1 | Retail shopping zone | |
| 22 | C-2 | General business and commercial district centres | ||||||
| 23 | C-3 | Wholesale, godowns, warehousing/regulated markets | ||||||
| 24 | C-4 | Service sector | ||||||
| 25 | C-5 | Regulated/Informal/Weekly markets | ||||||
| iii) | 3 | I | Industry | Purple | 31 | I-1 | Service and light industry | |
| 32 | I-2 | Extensive and heavy industry | ||||||
| 33 | I-3 | Special industrial zone - Hazardous, noxious and chemical | ||||||
| iv) | 4 | PS | Public and semi-public | Dark blue | 41 | PS-1 | Govt/Semi Govt/Public offices | |
| 42 | PS-2 | Govt land (use undetermined) | ||||||
| 43 | PS-3 | Police headquarter/Station, police line | ||||||
| 44 | PS-4 | Educational and research | ||||||
| 45 | PS-5 | Medical and health | ||||||
| 46 | PS-6 | Social, cultural and religious (including cremation and burial grounds) | ||||||
| 47 | PS-7 | Utilities and services | ||||||
| v) | 5 | M | Mixed use | Light yellow background with vertical hatching in black | 51 | M-1 | Mixed industrial use zone | |
| 52 | M-2 | Mixed residential zone | ||||||
| 53 | M-3 | Mixed commercial zone | ||||||
| vi) | 6 | P | Recreational | Light green | 61 | P-1 | Playgrounds/Stadium/Sports complex | |
| 62 | P-2 | Parks and gardens – Public open spaces | ||||||
| 63 | P-3 | Multi-open space (Maidan) | ||||||
²⁾ Alpha-numeric code.
¹⁾ Numeric code.
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
| vii) | 7 | T | Transportation and communication | Brown/Grey⁵⁾ | 71 | T-1 | Roads/Bus rapid transit system (BRTS) | |
| 72 | T-2 | Railways/Mass rapid transit system (MRTS) | ||||||
| 73 | T-3 | Airport | ||||||
| 74 | T-4 | Seaports and dockyards | ||||||
| 75 | T-5 | Bus depots/Truck terminals and freight complexes | ||||||
| 76 | T-6 | Transmission and communication | ||||||
| viii) | 8 | A | Primary activity | Dark green | 81 | PA-1 | Agriculture | |
| 82 | PA-2 | Forest and horticulture | ||||||
| 83 | PA-3 | Poultry and dairy farming | ||||||
| 84 | PA-4 | Rural settlements | ||||||
| 85 | PA-5 | Brick kiln and extractive areas | ||||||
| 86 | PA-6 | Others (Fishing, pottery, etc) | ||||||
| ix) | 9 | E | Protective and undevelopable use zone | Light blue | 91 | E-1 | Water bodies | |
| 92 | E-2 | Special recreation zone/Protective areas, such as sanctuaries/reserve forests and eco-sensitive zone | ||||||
| 93 | E-3 | Undevelopable use zone | ||||||
| x) | 10 | S | Special area | Pink | 101 | S-1 | Old built-up (Core) area | |
| 102 | S-2 | Heritage and conservation areas | ||||||
| 103 | S-3 | Scenic value areas | ||||||
| 104 | S-4 | Government restricted area (such as defence) | ||||||
| 105 | S-5 | Other uses/spot zone (see Note 5) |
NOTES
1 Overall, there could be 43 use zones at the development plan level within 10 land use categories at the perspective plan level as given in the above table.
2 Areas of informal activities may be identified in the above land use categories at level 2 for 1 to 7 level 1 use zones only.
3 Mixed use zone shall be identified at the development plan level, having dominant use and mixed use.
4 Use permissions for different activities, as specified in the next section on simplified use zone regulations may be provided at the project/action plan level or with the approval of the Statutory Authority as the case may be.
5 The process of changing/relaxing/modifying land use of part or ‘spot’ of a ‘zone’ in a particular land use is termed as ‘Spot Zoning’. Spot zoning may be done for comparatively smaller area in a particular land use zone in such a way that it does not affect the overall development plan.
6 Use zone regulations for the use permissibility (from the suggestive list) could be decided by the town planner depending upon the requirement/feasibility.
7 Appropriate code in terms of both numerical and alphabetic (letter) are provided to facilitate the reference and to have a simplified procedure to follow.
³⁾ This colour code is for Level 1 land uses.
⁴⁾ For subsequent levels of land uses different shades of Level 1 land use colour may be used along with relevant alpha-numeric code for clarity.
⁵⁾ For transportation and communication facilities, brown colour, and for roads, grey colour may be used. If so decided by the planning agency, different shades of grey may be used for both roads and facilities.
3.2 The various building uses and occupancies (see 7) permitted on the various zones shall be as given in the Master Plan of the town/city concerned.
Where the use of buildings or premises is not specifically designated on the Development/Master Plan or in the absence of Development Plan, shall be in conformity with the zone in which they fall.
Where the use of a site is specifically designated on the Development/Master Plan, it shall be used only for the purpose so designated.
No plot shall be put to any use, occupancy or premises other than the uses identified in 3.1, except with the prior approval of the Authority.
Buildings shall be so planned, designed and constructed as to ensure fire safety and this shall be done as per Part 4 ‘Fire and Life Safety’ of the Code.
3.7.1 Transferable development rights (TDR) is a compensation, in the form of floor area ratio (FAR) or development right, which shall entitle the owner for construction of built-up area, as per applicable regulations, on designated sites. The FAR credit shall be issued, in a certificate called as development right certificate (DRC). The DRC is transferrable in full or part thereof.
The development right certificate (DRC) shall be issued by the local body or the competent authority as per regulations and shall contain the following information:
a) Built-up area or FAR credit to which the owner is entitled;
b) Place and usage zone from which the DRC is generated (originating plot);
c) Place where the FAR credit shall be used (receiving plot); and
d) Details of development rights transferred and remaining.
TDR may be granted for,
a) Lands earmarked for various public purposes including road widening, which are subjected to acquisition, and are proposed in the plan or regulations prepared under the applicable town planning/municipal or any other legislation;
b) Development or construction of the amenity on the reserved land;
c) Heritage structure or precinct under the provision of development control regulations or any other applicable regulations;
d) In-lieu of constructing housing for slum dwellers, slum redevelopment, disused mill sites, etc; and
e) Purposes as may be notified by the Government as per notification.
Accommodation reservation (AR) is a planning tool for development of public amenities reserved in a redevelopment plan wherein local authority is not required to acquire the land by incurring expenditure on payment of compensation. In case of AR, the owner of land earmarked as public amenity, in the redevelopment plan, shall be permitted to develop his land, using full permissible FAR on the plot, subject to handing over the built-up area for the proposed use to the local body/Authority, free of all encumbrances, in lieu of full permissible FAR granted to him. The area utilized for the amenity shall not form part of FAR calculation.
Plots/dwelling units when located along a pedestrianized or vehicular ‘cul-de-sac’ road (see Fig. 4).

FIG. 4 CUL-DE-SAC CLUSTER
2.28 Density — The residential density expressed in terms of the number of dwelling units per hectare.
NOTE — Where such densities are expressed exclusive of community facilities and provision of open spaces and major roads (excluding incidental open spaces), these will be net residential densities. Where these densities are expressed taking into consideration the required open space provision and community facilities and major roads, these would be gross residential densities at neighbourhood level, sector level or town level, as the case may be. The provision of open spaces and community facilities will depend on the size of the residential community.
Incidental open spaces are mainly open spaces required to be left around and in between two buildings to provide lighting and ventilation.
2.29 Detached Building — A building detached on all sides.
2.30 Development — ‘Development’ with grammatical variations means the carrying out of building, engineering, mining or other operations, in, or over, or under land or water, on the making of any material change, in any building or land, or in the use of any building, land, and includes redevelopment and layout and subdivision of any land; and ‘to develop’ shall be construed accordingly.
2.31 Drain — A conduit, channel or pipe for the carriage of storm water, sewage, waste water or other water borne wastes in a building drainage system.
2.32 Drainage — The removal of any liquid by a system constructed for the purpose.
2.33 Dwelling Unit/Tenement — An independent housing unit with separate facilities for living, cooking and sanitary requirements.
2.34 Escalator — A power driven, inclined, continuous moving stairway used for raising or lowering passengers.
2.35 Exit — A passage, channel or means of egress from any building, storey or floor area to a street or other open space of safety.
2.36 External Faces of Cluster — Building edges facing the cluster open spaces.
2.37 Fire Separation — The distance in metres measured from the external wall of the building concerned to the external wall of any other building on the site, or from other site, or from the opposite side of a street or other public space for the purpose of preventing the spread of fire.
For the purpose of this Part, the following definitions shall apply.
2.1 Access — A clear approach to a plot or a building.
2.2 Accessory Use — Any use of the premises subordinate to the principal use and customarily incidental to the principal use.
2.3 Alteration — A change from one occupancy to another, or a structural change, such as an addition to the area or height, or the removal of part of a building, or any change to the structure, such as the construction of, cutting into or removal of any wall, partition, column, beam, joist, floor (including a mezzanine floor) or other support, or a change to or closing of any required means of ingress or egress or a change to the fixtures or equipment.
2.4 Approved — Approved by the Authority having jurisdiction.
2.5 Authority Having Jurisdiction — The Authority which has been created by a statute and which for the purpose of administering the Code/Part may authorize a committee or an official to act on its behalf; hereinafter called the ‘Authority’.
2.6 Back-to-Back Cluster — Clusters when joined back to back and/or on sides (see Fig. 1).

FIG. 1 BACK TO BACK CLUSTER
2.7 Balcony — A horizontal projection, with a handrail or balustrade or a parapet, to serve as passage or sitting out place.
2.8 Basement or Cellar — The lower storey of a building, below or partly below ground level.
2.9 Building — Any structure for whatsoever purpose and of whatsoever materials constructed and every part thereof, whether used as human habitation or not and includes foundation, plinth, walls, floors, roofs, chimneys, plumbing and building services, fixed platforms, Verandah, balcony, cornice or projection, part of a building or anything affixed thereto or any wall enclosing or intended to enclose any land or space and signs and outdoor display structures. Tents, Shamianahs, tarpaulin shelters, etc, erected for temporary and ceremonial occasions with the permission of the Authority shall not be considered as building.
2.10 Building, Height of — The vertical distance measured in the case of flat roofs, from the average level of the ground around and contiguous to the building or as decided by the Authority to the terrace of last livable floor of the building adjacent to the external walls; and in the case of pitched roofs, up to the point where the external surface of the outer wall intersects the finished surface of the sloping roof; and in the case of gables facing the road, the mid-point between the eaves level and the ridge. Architectural features serving no other function except that of decoration shall be excluded for the purpose of measuring heights. See 9.4.2.1.
BUREAU OF INDIAN STANDARDS
This Code (Part 3) covers development control rules, including such aspects as subdivision and layout rules, land use classifications, open spaces, area and height limitations, means of access, and parking spaces. This Part also covers the general building requirements, including those of various parts of buildings.
In addition to community open spaces, the layouts shall provide for the amenities as given in 5.5.1 to 5.5.13. These provisions may be modified based on specific requirements, as decided by the Authority.
| Land Area Required, Min | |
| a) Pre-Primary to secondary education | |
| 1) Pre-primary, nursery school — 1 for every 2 500 population | |
| i) Area per school | 0.08 ha |
| ii) Location of pre-primary/nursery school | to be located near a park |
| 2) Primary school (class 1 to 5) — 1 for every 5 000 population | |
| i) Strength of the school — 500 students | |
| ii) Area per school: | 0.40 ha |
| a) School building area | 0.20 ha |
| b) Play field area (with a minimum of 18 m × 36 m to be ensured for effective play) | 0.20 ha (which is inclusive of the limited parking requirement for functional uses) |
| 3) Senior secondary school (class 6 to 12) — 1 for every 7 500 population | |
| i) Strength of the school — 1 000 students | |
| ii) Area per school: | 1.80 ha |
| a) School building area | 0.60 ha |
| b) Play field area (with a minimum of 68 m × 126 m to be ensured for effective play) | 1.00 ha |
| c) Parking area | 0.20 ha |
| 4) Integrated school without hostel facility (class 1 to 12) — 1 for every 90 000 to 100 000 population | |
| i) Strength of the school — 1 500 students | |
| ii) Area per school: | 3.50 ha |
| a) School building area | 0.70 ha |
| b) Play field area | 2.50 ha |
| c) Parking | 0.30 ha |
| iii) Location | To be located near a sport facility |
| 5) Integrated school with hostel facilities (class 1 to 12) — 1 for every 90 000 to 100 000 population | |
4.1 Every building/plot shall abut on a public/private means of access like streets/roads duly formed.
4.2 Every person who erects a building shall not at any time erect or cause or permit to erect any building which in any way encroaches upon or diminishes the area set apart as means of access required in the Code. No buildings shall be erected so as to deprive any other building of the means of access.
The residential plots shall abut on a public means of access like street/road. Plots which do not abut on a street/road shall abut/front on a means of access, the width and other requirements of which shall be as given in Table 1.
| Sl No. | Width of Means of Access | Length of Means of AccessMax |
| m | m | |
| (1) | (2) | (3) |
| i) | 6.0 | 75 |
| ii) | 7.5 | 150 |
| iii) | 9.0 | 250 |
| iv) | 12.0 | 400 |
| v) | 18.0 | 1 000 |
| vi) | 24.0 | above 1 000 |
| NOTE — If the development is only on one side of the means of access, the prescribed widths may be reduced by 1m in each case. | ||
In no case, development on plots shall be permitted unless it is accessible by a public street of width not less than 6 m.
For all assembly buildings like, theatres, cinema houses, assembly halls, stadia; educational buildings; markets, hospitals; industrial buildings and other buildings which attract large crowd, the means of access shall not be less than the following:
| Sl No. | Width of Means of Access m | Length of Means of Access m |
|---|
In any layout or sub-division of land measuring 0.3 ha or more in residential and commercial zones, the community open spaces shall be reserved for recreational purposes which shall as far as possible


MINIMUM CLEAR RAMP WIDTH, m
| ONE WAY | TWO WAY | |
| LMV | 3.0 | 6.0 |
| LCV | 4.5 | 9.0 |
| HMV | 6.0 | 12.0 |
| FIRE TENDER | 7.5 | |
8B RAMPS FOR PODIUM
FIG. 8 BUILDINGS ON PODIUM AND THEIR RAMPS


FIRE TENDER ACCESS (FTA)
9A EMERGENCY VEHICLE ACCESS REQUIREMENT IN CASE PODIUM IS NOT ACCESSIBLE BY FIRE TENDER

9B EXTENT OF PODIUM PROJECTION ALLOWED BEYOND BUILDING ON SIDE HAVING FIRE TNEDER ACCESS (IF PODIUM IS NOT ACCESSIBLE BY FIRE TENDER)
In the case of sub-division of land in industrial zones of area 0.8 hectare or more, 5 percent of the total area shall be reserved as amenity open space which shall also serve as a general parking space; when such amenity open space exceeds 1 500 m² , the excess area could be utilized for the construction of buildings for banks, canteens, welfare centers and such other common purposes considered necessary for the industrial user, as approved by the Authority.
5.4.1 In all industrial plots measuring 1000m² or more in area, 10 percent of the total area shall be provided
as an amenity open space to a maximum of 2 500 m² . Such an amenity open space shall have a means of access and shall be so located that it could be conveniently utilized as such by the persons working in the industry.
2.38 Floor — The lower surface in a storey on which one normally walks in a building. The general term ‘floor’ unless specifically mentioned otherwise shall not refer to a ‘mezzanine floor’.
2.39 Floor Area Ratio (FAR) — The quotient obtained
by dividing the total covered area (plinth area) on all floors by the area of the plot:
2.40 Gallery — An intermediate floor or platform projecting from a wall of an auditorium or a hall providing extra floor area, additional seating accommodation, etc. It shall also include the structures provided for seating in stadia.
2.41 Garage, Private — A building or a portion thereof designed and used for parking of private owned motor driven or other vehicles.
2.42 Garage, Public — A building or portion thereof, other than a private garage, designed or used for repairing, servicing, hiring, selling or storing or parking motor driven or other vehicles.
2.43 Group Housing — Housing for more than one dwelling unit, where land is owned jointly (as in the case of cooperative societies or the public agencies, such as local authorities or housing boards, etc) and the construction is undertaken by one Agency.
2.44 Group Open Space — Open space within a cluster.
Group open space is neither public open space nor private open space. Each dwelling unit around the cluster open space have a share and right of use in it. The responsibility for maintenance of the same is to be collectively shared by all the dwelling units around.
2.45 Habitable Room — A room occupied or designed for occupancy by one or more persons for study, living, sleeping, eating, kitchen if it is used as a living room, but not including bathrooms, water-closet compartments, laundries, serving and store pantries, corridors, cellars, attics, and spaces that are not used frequently or during extended periods.
2.46 Independent Cluster — Clusters surrounded from all sides by vehicular access roads and/or pedestrian paths (see Fig. 5).

FIG. 5 INDEPENDENT CLUSTER
2.47 Interlocking Cluster — Clusters when joined at back and on sides with at least one side of a cluster common and having some dwelling units opening onto or having access from the adjacent clusters.
Dwelling units in such clusters should have at least two sides open to external open space. Houses in an interlocking cluster may have access, ventilation and light from the adjacent cluster and should also cater for future growth (see Fig. 6).

FIG. 6 INTERLOCKING CLUSTER
2.48 Internal Faces of Cluster — Building edges facing the adjacent cluster open space (as in case of interlocking cluster) of the surrounding pedestrian paths or vehicular access roads.
2.49 Ledge or Tand — A shelf-like projection, supported in any manner whatsoever, except by means of vertical supports within a room itself but not having projection wider than 1 m.
2.50 Lift — An appliance designed to transport persons or materials between two or more levels in a vertical or substantially vertical direction by means of a guided car or platform. The word ‘elevator’ is also synonymously used for ‘lift’.
2.51 Loft — A structure providing intermediate storage space in between two floors with a maximum height of 1.5 m, without having a permanent access.
2.52 Master Plan — A master plan formulated under any relevant act (Town and Country Planning or Development Act or Municipal Act) for any town, approved and notified by the State Government.
2.53 Mezzanine Floor — An intermediate floor between two floors of any storey forming an integral part of floor below.
2.54 Occupancy or Use Group — The principal occupancy for which a building or a part of a building is used or intended to be used; for the purposes of classification of a building according to occupancy; an occupancy shall be deemed to include subsidiary occupancies which are contingent upon it.
2.55 Occupancy, Mixed — A multiple occupancy where the occupancies are intermingled.
2.56 Open Clusters — Clusters where cluster open spaces are linked to form a continuous open space (see Fig. 7).

FIG. 7 OPEN CLUSTER
2.57 Open Space — An area, forming an integral part of the plot, left open to the sky.
NOTE — The open space shall be the minimum distance measured between the front, rear and side of the building and the respective plot boundaries.
2.58 Open Space, Front — An open space across the front of a plot between the building line and front boundary of the plot.
2.59 Open Space, Rear — An open space across the rear of a plot between the rear of the building and the rear boundary of the plot.
2.60 Open Space, Side — An open space across the side of the plot between the side of the building and the side boundary of the plot.
2.61 Owner — A person, a group of persons or a body having a legal interest in land and/or building thereon. This includes free holders, leaseholders or those holding a sublease, who will have a legal right to occupation and have liabilities in respect of safety or building condition.
In case of lease or sublease holders, as far as ownership with respect to the structure is concerned, the structure of a flat or structure on a plot belongs to the allottee/lessee till the allotment/lease subsists.
Note — For the purpose of the Code, the word ‘owner’ will also cover the generally understood terms like ‘client’, ‘user’, etc.
2.62 Parapet — A low wall or railing built along the edge of a roof or floor.
2.63 Parking Space — An area enclosed or unenclosed, covered or open, sufficient in size to park vehicles, together with a drive-way connecting the parking space with a street or alley and permitting ingress and egress of the vehicles.
2.64 Partition — An interior non-load bearing barrier, one storey or part-storey in height.
2.65 Plinth — The portion of a structure between the surface of the surrounding ground and surface of the floor, immediately above the ground.
2.66 Plinth Area — The built up covered area measured at the floor level of the basement or of any storey {see accepted standard [3(1)]}.
2.67 Porch — A covered structure supported on pillars or otherwise for the purpose of pedestrian or vehicular approach to a building.
2.68 Road — See ‘Street’.
2.69 Road Line — See ‘Street Line’.
2.70 Room Height — The vertical distance measured from the finished floor surface to the finished ceiling surface. Where a finished ceiling is not provided, the underside of the joists or beams or tie beams shall determine the upper point of measurement.
2.71 Row Housing/Row Type Building — A row of buildings, with only front, rear and interior open spaces, where applicable.
2.72 Semi-Detached Building — A building detached on three sides.
2.73 Service Road/Lane — A road/lane provided adjacent to a plot(s) for access or service purposes as the case may be.
2.74 Set-Back Line — A line usually parallel to the plot boundaries and laid down in each case by the Authority, beyond which nothing may be constructed towards the plot boundaries.
2.75 Site (Plot) — A parcel (piece) of land enclosed by definite boundaries.
2.76 Site, Corner — A site at the junctions of and fronting on two or more intersecting streets.
2.77 Site, Depth of — The mean horizontal distance between the front and rear site boundaries.
2.78 Site, Double Frontage — A site, having a frontage on two streets, other than a corner plot.
2.79 Site, Interior or Tandem — A site access to which is by a passage from a street whether such passage forms part of the site or not.
2.80 Staircover (or Mumty) — A structure with a roof over a staircase and its landing built to enclose only the stairs for the purpose of providing protection from weather and not used for human habitation.
2.81 Storey — The portion of a building included between the surface of any floor and the surface of the floor next above it, or if there be no floor above it, then the space between any floor and the ceiling next above it.
2.82 Storey, Topmost — The uppermost storey in a
building whether constructed wholly or partly on the roof.
2.83 Street — Any means of access, namely, highway, street, lane, pathway, alley, stairway, passageway, carriageway, footway, square, place or bridge, whether a thoroughfare or not, over which the public have a right of passage or access or have passed and had access uninterruptedly for a specified period, whether existing or proposed in any scheme, and includes all bunds, channels, ditches, storm-water drains, culverts, footpaths, sidewalks, traffic islands, roadside trees and hedges, retaining walls, fences, barriers and railings within the street lines.
2.84 Street Level or Grade — The officially established elevation or grade of the central line of the street upon which a plot fronts and if there is no officially established grade, the existing grade of the street at its mid-point.
2.85 Street Line — The line defining the side limits of a street.
2.86 To Erect — To erect a building means,
a) to erect a new building on any site whether previously built upon or not; and
b) to re-erect any building of which portions above the plinth level have been pull down, burnt or destroyed.
2.87 Tower-Like Structures — Structures shall be deemed to be tower-like structures when the height of the tower-like portion is at least twice the height of the broader base at ground level.
2.88 Verandah — A covered area with at least one side open to the outside with the exception of 1 m high parapet on the upper floors to be provided on the open side.
2.89 Volume to Plot Area Ratio (VPR) — The ratio of volume of building measured in cubic metre to the area of the plot measured in square metre, and expressed in metre.
2.90 Water Closet— A water flushed plumbing fixture designed to receive human excrement directly from the user of the fixture. The term is used sometimes to designate the room or compartment in which the fixture is placed.
2.91 Window — An opening to the outside other than a door, which provides all or part of the required natural light or ventilation or both to an interior space.
2.11 Building Envelope — The horizontal spatial limits up to which a building may be permitted to be constructed on a plot.
2.12 Building Line — The line up to which the plinth of a building adjoining a street or an extension of a street or on a future street may lawfully extend. It includes the lines prescribed, if any, in any scheme. The building line may change from time to time as decided by the Authority.
2.13 Cabin — A non-residential enclosure constructed of non-load bearing partition.
2.14 Canopy — A projection over any entrance.
2.15 Carpet Area — The covered area of the usable rooms at any floor level (excluding the area of the wall) {see accepted standard [3(1)]}.
2.16 Chhajja — A sloping or horizontal structural overhang usually provided over openings on external walls to provide protection from sun and rain.
2.17 Chimney — An upright shaft containing one or more flues provided for the conveyance to the outer air of any product of combustion resulting from the operation of heat producing appliance or equipment employing solid, liquid or gaseous fuel.
2.18 Chowk or Courtyard — A space permanently open to the sky, enclosed fully or partially by building and may be at ground level or any other level within or adjacent to a building.
2.19 Chowk, Inner — A chowk enclosed on all sides.
2.20 Chowk, Outer — A chowk one of whose sides is not enclosed.
2.21 Closed Clusters —Clusters with only one common entry into cluster open space (see Fig. 2).

FIG. 2 CLOSED CLUSTER
2.22 Cluster — Plots or dwelling units or housing grouped around an open space (see Fig. 3). Ideally housing cluster should not be very large. In ground and one storeyed structures not more than 20 houses should be grouped in a cluster. Clusters with more dwelling units will create problems in identity, encroachments and of maintenance.
2.23 Cluster Court Town House — A dwelling in a cluster plot having 100 percent or nearly 100 percent ground coverage with vertical expansion, generally limited to one floor only and meant for self use.
2.24 Cluster Plot — Plot in a cluster.
2.25 Cooking Alcove — A cooking space having direct access from the main room without any inter-communicating door.
2.26 Covered Area — Ground area covered by the building immediately above the plinth level. The area covered by the following in the open spaces is excluded

FIG. 3 CLUSTER
from covered area (see Table 5):
a) Garden, rockery, well and well structures, plant nursery, water pool, swimming pool (if uncovered), platform round a tree, tank, fountain, bench, Chabutra with open top and unenclosed on sides by walls and the like;
b) Drainage culvert, conduit, catch-pit, gully pit, chamber, gutter and the like;
c) Compound wall, gate, unstoreyed porch and portico, canopy, slide, swing, uncovered staircase, ramps areas covered by Chhajja and the like; and
d) Watchmen's booth, pump house, garbage shaft, electric cabin or sub-stations, and such other utility structures meant for the services of the building under consideration.
NOTE — For the purpose of this Part, covered area equals the plot area minus the area due for open spaces.
It is expected that for proper coordination and enforcement of the development control rules and general building requirements, the departments concerned, namely, the town and country planning department, urban development authority, urban local body and the building department, will coordinate the total development and building activity at both organizational and technical levels.
Particular attention is invited to Table 5 on floor area ratio (FAR) limitations. It is emphasized that the floor area of a single storey building is limited in absolute terms by the type of construction and occupancy class. Also, the absolute floor areas for different types of construction and different occupancies have a definite ratio among them. The ratios as recommended in the American Iron and Steel Institute Publication of 1961 ‘Fire protection through modern building codes’ have been generally adopted in this Part and Table 5 has been developed on this basis. This, Table 5 is repeated in Part 4 ‘Fire and Life Safety’ of the Code also, for convenience of reading.
Limitation of areas and heights of buildings are regulated by specifying floor area ratio (FAR) or floor space index (FSI) and ground coverage. The significance of the contribution of different types of construction giving different fire resistances has not been taken cognizance of in specifying FAR for different occupancies, in the present development control rules and municipal byelaws of the country. Table 5, therefore, gives the comparative ratios of FAR between types of buildings and occupancy classes and these have been specified mainly from the fire protection aspect of buildings. To arrive at the actual FAR for different buildings coming up in different areas, the Authority should further modify them, by taking into consideration other aspects like population density of any area, parking facilities required, the traffic load (road width) and the services available. The heights of buildings shall also be regulated, keeping in view the local fire fighting facilities.
In some state byelaws, the FAR (or FSI) has been expressed in the form of percentage. However, the Committee responsible for the preparation of this Code is of the opinion that, it being a ratio should be expressed only in the form of a ratio, as done in this Part.
It is particularly to be borne in mind by the Authority that the ratios are definitive and it may assess the particular FAR for a type of construction and for an occupancy and establish a new table, but retaining the comparative ratios as given in Table 5.
Keeping in view the enormous problems faced by the country with regard to the ever increasing squatter settlements/pavement dwellers in urban areas (cities of all sizes), it is imperative that all the urban local bodies and urban development authorities sooner or later evolve schemes for their rehabilitation. The resources are meagre and the problems are enormous. There has been a tendency on the part of a number of urban development authorities/urban local bodies to link space norms with affordability. Affordability is an important criterion but at the same time a public agency may not ignore the basic minimum needs of the family to be housed (including the mental, physical and social health of the marginalized groups, which is linked with shelter). The urban local bodies shall have to evolve appropriate policies for their integration with the overall development process and generate/allocate resources and more importantly adopt a planning process, which are people friendly and inclusive. Therefore, keeping in view the needs of low income housing, to cater to Economically Weaker Sections of Society (EWS) and Low Income Group (LIG), the requirements on planning, design of layout/shelter have been rationalized and the same are provided in this Part. This information is based on the provisions of IS 8888 (Part 1):1993 'Guide for requirements of low income housing: Part 1 Urban areas (first revision)'.
It is important that the fruits of development are equally shared by all cross-section of the society irrespective of their age and abilities. This Code therefore covered provisions for buildings and built environment to ensure a barrier-free
environment for elders and persons with disabilities. The goal of barrier free design is to provide an environment that supports the independent functioning of individuals so that they can participate without assistance, in everyday activities. It has been intended to progressively update these provisions and make the same more effective and elaborate based on experience gained with the implementation of the Code and feedback received from stakeholders. As a conscious decision, opportunity has been taken in this revision of the Code to further mainstream the issue of barrier free environment by covering the requirements at greater length. The concept of universal design has also been included herein that promotes the usability of built environment by all without discrimination. It is worthwhile to note that The Persons with Disabilities (Equal Opportunities, Protection of Rights and Full Participation) Act, 1995 in its Chapter VIII ‘Non-Discrimination’, Section 44 to 46 mandates accessibility in public buildings and transportation systems. National policy for persons with disabilities also emphasizes the role of barrier-free environment as one that enables people with disabilities to move about safely and freely, and use the facilities within the built environment. Therefore, to the maximum extent possible, buildings/places/transportation systems for public use should be made barrier free. India has also signed and ratified the UN Convention on Rights of Persons with Disabilities that casts an obligation on the member states in its Article 9‘Accessibility’, to enable persons with disabilities to live independently and participate fully in all aspects of life.
Further, city development process would need a dynamic approach to take care of urban renewal and also development needs in dense core areas of the cities. Innovative approaches in planning and design with participatory models of public private-people's partnership become necessary to solve the emerging development needs. With this in view, many city development authorities have evolved innovative planning and development tools like transferable development rights (TDR) where the developer would receive a portion of the development rights in a new location, keeping in view the constraints in the existing land area and the development potential. Such development rights may be transferred into outskirts or new developed areas where land availability is assured. This would encourage the professionals and developers to participate in urban renewal and at the same time ensure that the developments in both the inner core areas and new areas take place in a planned manner. The TDR concept should be increasingly encouraged by the authority dealing with urban renewal, redevelopment projects including housing and redevelopment projects for slum dwellers.
Transit oriented development (TOD), as a concept, integrates land uses and mass transportation such as bus rapid transit (BRT) and rail based transit like metro-rail, mono-rail, light-rail, ring-rail, etc. The basic objective is to plan cities in a manner where people conveniently walk and use public transport for most of their trips and, thus, reduce dependence on private mode and provide benefits to the city which include reduction in congestion, delays and accidents on roads; reduction of pollution caused by automobiles; and improvement in liveability, mobility and convenience of the citizens. TOD makes city compact and increases its efficiency and functioning. The TOD is desirable as it, (a) reduces/discourages private vehicle dependency and induces public transport use though planning, designing, policy measures and enforcement; and (b) provides easy access to public transport, within walking distance, to a majority of people, through densification and enhanced connectivity.
Some of the planning and design principles applied to create TOD include creation of,
a) pedestrian and non-motorized transport friendly environment;
b) efficient public and para-transport system supporting the transit system;
c) multi-modal interchange and street connectivity;
d) mixed land uses and appropriate intensity of development; and
e) well designed and integrated parking thus requiring reduced parking requirements in comparison to the norms given in this Part.
TOD concept may be suitable for all newly planned green field cities. However, it can also be applied to existing brown field cities where new expansion/development are taken up backed up with effective mass rapid transport system and new nodes. The Authorities may take up appropriate studies to evaluate suitability of TOD concept under relevant situations.
Urbanization in India is taking place at a rapid pace. As per the 2011 Census, 31.16 percent of the country's population resides in urban areas. This figure was 27.8 percent in 2001. The urban component is expected to rise to around 40 percent by 2020. As Indian cities continue to grow demographically and spatially, the challenge of improving urban infrastructure is enormous. While the number of urban centres has increased manifold between 1901 and 2011, the urban population increased six fold, resulting in a top-heavy urban settlement hierarchy with a large number of primate settlements. It is expected that the number of towns and cities which was 7 933 as per Census, 2011 is likely to cross the 10 000 mark in next two decades. As a result of liberalization, the demographic
trends of urbanization are accompanied by both challenges and opportunities in the management and financing of urban development.
Unprecedented urbanization has been fuelled by rapid economic growth and even more rapid industrialization especially in the past three decades or so. With globalization, this trend of rapid economic growth and urbanization is likely to accentuate further. In 1901, Kolkata was the only metropolitan city (million plus) in the country. The number of metropolitan cities increased to 5 in 1951, 12 in 1981, 23 in 1991, 35 in 2001 and 53 in 2011. The 53 metropolitan cities together account for a population of about 158 million in 2011, that is, 42 percent of urban population of the country. It is expected that this number would be about 85 by 2051.
Going by the present trends, by 2051, India would be the most populous country with 1.70 billion people and 0.19 ha per capita land availability. By 2051, 820 million people will live in urban settlements constituting about 50 percent of the total population. Cities in the country would emerge as centres of both hope and despair: while being engines of economic and social development they may also be congested centres of poverty and environmental degradation. The million plus cities constitute 42 percent of the total urban population, while the Class I (more than 1 lakh population) towns constituted 60.04 percent, followed by 11 percent in Class II (50 000-100 000 population) towns, 15.4 percent in Class III (20 000- 50 000 population) towns and the rest 13.56 percent constituted by Class IV, V and VI towns (less than 20 000 population).
Further, in the Indian practice, mega-cities (cities over 50 lakhs population) are 8 in number; metro-cities (cities having 10 to 50 lakhs population) are 45 in number. These 53 cities above 10 lakhs population is likely to be above 70 by 2021. The other cities are either small or medium towns or cities with different population limits. Urbanization in above cities and towns (mega-cities, metro-cities, small and medium towns and cities) will be different in nature and the development challenges are also different keeping in view the extent of urbanization, industrialization, commercialization and the nature of transportation needs. Therefore, the Code provisions should be appropriately utilized depending upon the need of hierarchy of cities for which the administrative and technical requirements have been covered in the Code for various facets of the activity.
The first version of this Part was formulated in 1970. As a result of incorporation of this Part in the revised development control rules and building byelaws of some municipal corporations and municipalities, some useful suggestions had emerged. The first revision of this Part was brought out in 1983, where these suggestions were incorporated to the extent possible. The major modifications incorporated in the first revision included:
a) Addition of development control rules giving guidance on means of access, community spaces and other aspects required for planning layouts.
b) Addition of provisions regarding plot sizes and frontage for different types of buildings, such as detached, semi-detached, row type and special housing schemes.
c) Requirements of open spaces for other occupancies, such as educational, institutional, assembly, industrial buildings, etc were included.
d) Provisions relating to interior open space were elaborated, including requirements for ventilation shaft.
e) Requirements of open spaces for group housing development were covered.
f) Requirements of off-street parking spaces were covered.
g) Requirements for greenbelts and landscaping including norms for plantations of shrubs and trees were covered.
h) Requirements of certain parts of buildings, such as loft, store room, garage, basement, chimney, parapet, cabin, boundary wall, wells, septic tanks, office-cum-letter box room, meter room were included.
j) Special requirements of low income housing were covered.
The term Development Control Rules used in this Part encompasses the related aspects comprehensively with a view to promoting orderly development of an area.
The major modifications incorporated in the second revision included:
a) Terminology given in this Part were made exhaustive by incorporating definitions of additional terms used, such as access, chimney, to erect, etc, and number of terms pertaining to cluster planning for housing.
b) Detailed planning norms/open spaces for various amenities such as educational facilities, health care facilities, socio-cultural facilities, distribution services, police, civil defence and home guards, and fire services were included.
c) Off-street parking requirements were also included for cities with population, (1) between 1 000 000 and 5 000 000, and (2) above 5 000 000 (see Annex A).
d) Special requirements for low income housing were modified and updated based on the revision of concerned Indian Standard namely IS 8888:1978 as IS 8888 (Part 1):1993 ‘Guide for requirements of low income housing : Part 1 Urban area (first revision)’. Single room dwelling was discouraged, guidelines for water seal latrine were incorporated, and cluster planning approach were recommended.
e) Requirements for cluster planning for housing were added based on the guidelines given in IS 13727:1993 'Guide for requirements of cluster planning for housing'.
f) Special requirements for low income housing for rural habitat planning were added.
g) Special requirements for development planning in hilly areas were added.
h) The requirements for buildings and facilities for the physically challenged were revised, with listing of additional categories of physically challenged; modifications in requirements of ramps, stairs, doors, handrails and controls; and incorporation of additional requirements regarding windows.
In this third revision, following major modifications have been incorporated:
a) Definitions of additional terms have been included and some of the existing definitions have been modified in the terminology clause.
b) Reference of IS 3861 : 2002 ‘Method of measurement of plinth, carpet and rentable areas of buildings (second revision)’ has been added for correct interpretation of plinth area and built-up area.
c) Land use classification has been modified.
d) A new clause on footpaths giving guidance on width of footpath to be adopted based on expected pedestrian traffic as also recommended width of footpath corresponding to adjacent land use, has been added.
e) Provisions on Transferable Development Rights (TDR) has been included.
f) Provisions on Accommodation Reservation (AR) have been included.
g) Provisions for buildings on podium including permitted uses in podium, general requirements for the same and requirements for fire tender movement have been incorporated under the clause on means of access.
h) Planning norms for amenities have been modified and new amenities have been covered.
j) Requirements for minimum clearances from an overhead electric supply line have been modified based on current Central Electricity Authority (Measures Relating to Safety and Electric Supply) Regulations, 2010 taking into account effect of sag and wind pressure.
k) Provisions for sunken courtyard have been added for meeting the light and ventilation requirements for basement area.
m) For height restrictions in the vicinity of aerodromes, reference to concerned notification of the Ministry of Civil Aviation, Govt of India has been made.
n) Considering that high density developments are being increasingly promoted in master plans and development policies, maximum coverage and floor area ratio for densities 200 to 400 dwelling units/hectare have been added.
p) Provisions for underground or multi-storeyed parking as also mechanized parking of vehicles has been included.
q) Provisions relating to basements have been reviewed and updated keeping in view the latest developments.
r) Requirements for accessibility in buildings and built environment for elders and persons with disabilities have been thoroughly revised and updated.
s) Provisions for solar energy utilization have been included.
t) Norms for off-street parking spaces have been revised.
u) Special requirements for low income housing have been updated.
w) Special requirements for development planning in hilly areas have been updated.
The information contained in this Part is also based on the following Indian Standards:
IS 4963 : 1987
Recommendations for buildings and facilities for physically handicapped (first revision)
IS 8888 (Part 1): 1993 Guide for requirements of low income housing : Part 1 Urban area (first revision)
IS 13727 : 1993 Guide for requirements of cluster planning for housing
IS 4963 : 1987 is under revision, the provisions of revised version of this standard shall be referred when available. In revising the provisions of this Part, assistance has also been derived from the following publications:
Urban and Regional Development Plans Formulation and Implementation Guidelines, 2014, Town and Country Planning Organization
IRC : 103-2012 Guidelines for Pedestrian Facilities (first revision)
ISO 21542 : 2011 Building construction — Accessibility and usability of the built environment
Planning a barrier free environment, 2011 prepared by Office of the Chief Commissioner for Persons with Disabilities, Ministry of Social Justice and Empowerment, Government of India
Harmonized guidelines and space standards for barrier free built environment for persons with disability and elderly persons, Ministry of Urban Development, 2016
All standards cross-referred here or in the main text of this Part, are subject to revision. The parties to agreement based on this Part are encouraged to investigate the possibility of applying the most recent editions of the standards.
For the purpose of deciding whether a particular requirement of this Part of the Code is complied with, the final value, observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance with IS 2 : 1960 ‘Rules for rounding off numerical values (revised)’. The number of significant places retained in the rounded off value should be the same as that of the specified value in this Part.
| i) Strength of school — 1 500 students |
| ii) Area per school: | 3.90 ha |
| a) School building area | 0.70 ha |
| b) Play field area | 2.50 ha |
| c) Residential (including hostel area) | 0.40 ha |
| d) Parking area | 0.30 ha |
| iii) Location | To be located near a sport facility |
| 6) School for children with disabilities (Class 1 to 12) — 1 for every 45 000 population |
| i) Strength of the school — 400 students |
| ii) Area per school: | 0.70 ha |
| a) School building area | 0.20 ha |
0.30 ha
0.20 ha
To be located near a park or sport facility
NOTE — The schools should be inclusive providing education to all children including those with disabilities. However it may be required to have exclusive schools in case of certain disabilities, such as, speech, hearing, sight and multiple disabilities.
0.20 ha
To be located near a park and
The schools should preferably face service roads and roads with less traffic intensity.
non-noise polluting zone
| 1) College — 1 for every 125 000 population | |
| i) Strength of the college — 1 000 to 1 500 students | |
| ii) Area per college: | 5.00 ha |
| a) College building area | 1.80 ha |
| b) Play field area | 2.50 ha |
| c) Residential (including hostel area) | 0.40 ha |
| d) Parking area | 0.30 ha |
| 2) University campus | |
| Area: | 10.00 ha to 60.00 ha |
| i) Residential (if included) area | 25 percent of total land area |
| ii) Sports and cultural activities | 15 percent of total land area |
| iii) Parks and landscape including green belt | 15 percent of total land area |
| 1) Technical education centre (A) — 1 for every 1 000 000 population to include 1 industrial training institute (ITI) and 1 polytechnic | |
| i) Strength of ITI — 400 students | |
| ii) Strength of polytechnic — 500 students | |
| iii) Area per technical education centre: | 4.00 ha |
| a) Area for ITI | 1.60 ha |
| b) Area for polytechnic | 2.40 ha |
Area per technical education centre: 4.00 ha i) Area for ITI 1.60 ha ii) Area for technical centre 2.10 ha iii) Area for coaching centre 0.30 ha
| 1) Engineering college — 1 for every 1 000 000 population | |
| i) Strength of the college — 1 500 students | |
| ii) Area per college | 6.00 ha |
Medical college — 1 for every 1 000 000 population Area of site including space for general hospital 15.00 ha
Nursing and paramedic institute — 1 for every 1 000 000 population Plot area per institute (subject to Nursing Council of India/Ministry of Health Norms) 0.20 ha
Veterinary institute Area As per Veterinary Council of India/Ministry of Agriculture norms (subject to availability of land)
| 5) Other professional colleges — 1 for every 1 000 000 population | |
| i) Strength of the college — 250 to 1 500 students | |
| ii) Area of site: | |
| a) for students strength up to 250 students | 2.00 ha |
| b) additional area of site for every additional 100 students or part thereof up to total strength of 1 000 students | 0.50 ha |
| c) for strength of college from 1 000 to 1 500 students | 6.00 ha |
| Land Area Required, Min | |
| a) Dispensary — 1 for every 15 000 populationArea | 0.08 ha to 0.12 ha |
| b) Nursing home, child welfare and maternity centre — 1 for every45 000 to 100 000 population1) Capacity — 25 to 30 beds2) Area 0.20 ha to 0.30 ha | |
| c) Poly-clinic with some observation beds — 1 for every 100 000 population)Area | 0.20 ha to 0.30 ha |
| d) Intermediate hospital (category B) — 1 for every 100 000 population | |
| 1) Capacity — 80 beds (initially the provision may be for 50 beds including20 maternity beds) | |
| 2) Total area:i) Area for hospitalii) Area for residential accommodation | 1.00 ha0.60 ha0.40 ha |
| e) Intermediate hospital (category A) — 1 for every 100 000 population | |
| 1) Capacity — 200 beds (initially the provision may be for 100 beds) | |
| 2) Total area:i) Area for hospitalii) Area for residential accommodation | 3.70 ha2.70 ha1.00 ha |
| f) General hospital — 1 for every 250 000 population | |
| 1) Capacity — 500 beds (initially the provision may be for 300 beds) | |
| 2) Total area:i) Area for hospitalii) Area for residential accommodation | 6.00 ha4.00 ha2.00 ha |
| g) Multi-speciality hospital — 1 for 100 000 population | |
| 1) Capacity — 200 beds (initially the provision may be for 100 beds) | |
| 2) Total area:i) Area for hospitalii) Area for residential accommodation | 9.00 ha6.00 ha3.00 ha |
| h) Speciality hospital — 1 for every 100 000 population | |
| 1) Capacity — 200 beds (initially the provision may be for 100 beds) | |
| 2) Total area:i) Area for hospitalii) Area for residential accommodation | 3.70 ha2.70 ha1.00 ha |
| j) Family welfare centre — 1 for every 50 000 populationArea | 500 m² to 800 m² |
| k) Diagnostic centre — 1 for every 50 000 populationArea | 500 m² to 800 m² |
| PART 3 DEVELOPMENT CONTROL RULES AND GENERAL BUILDING REQUIREMENTS | PART 3 DEVELOPMENT CONTROL RULES AND GENERAL BUILDING REQUIREMENTS |
| m) Veterinary hospital for pets and animals — 1 for every 500 000 population Area | 0.20 ha |
| n) Dispensary for pet animals and birds — 1 for every 100 000 population Area | 300 m² |
| p) Rehabilitation centres Area | As per requirement |
| Land Area Required, Min | |
|---|---|
| a) Community room — 1 for every 5 000 populationArea | 750 m² |
| b) Community hall, Mangal Karyalaya/Kalyana Mandapam/Barat Ghar/library — 1 for every 15 000 population)Area | 2 000 m² |
| c) Recreational club — 1 for every 100 000 populationArea | 10 000 m² |
| d) Music, dance and drama centre — 1 for every 100 000 populationArea | 1 000 m² |
| e) Meditation and spiritual centre — 1 for every 100 000 populationArea | 5 000 m² |
| f) Socio-cultural centre/Exhibition cum fair ground — 1 for every 1 000 000 populationArea | 15.00 ha |
| g) Anganwadi-housing area/cluster — 1 for every 5 000 populationArea | 200 to 300 m² |
| h) Old age home — 1 for every 500 000 populationArea | 1000 m² Max,subject to availability of land |
| j) Religious facilities1) At neighbourhood/housing cluster level — 1 for every 5 000 populationArea | 400 m² |
| 2) At sub-city level in urban extension — 1 for every 1 000 000 populationArea | 4.00 ha |
| k) Science centre — 1 for every 1 000 000 populationArea | As per requirement |
| m) International convention centre — 1 at city levelArea | As per requirement |
| n) Other facilities | |
| 1) Orphanage/Children’s centre (one each) — 1 for every 1 000 000 populationArea | 1 000 m² Max,subject to availability of land |
| 2) Centre for support services for persons with disabilities — 1 for every 1 000 000 populationArea | 1 000 m² Max,subject to availability of land |
| 3) Working women/men hostel — 1 for every 1 000 000 populationArea | 1 000 m² Max,subject to availability of land |
| 4) Adult education centre — 1 for every 1 000 000 populationArea | 1 000 m² Max,subject to availability of land |
| 5) Night shelter — 1 for every 1 000 000 populationArea | 1 000 m² Max,subject to availability of land |
| 5.5.4 Distribution Services | 5.5.4 Distribution Services |
| Land Area Required, Min | Land Area Required, Min |
| a) Petrol/diesel filling and servicing centre — May be permitted in central as well as sub-central business district, district centres, community centres (only filling station), residential and industrial use zones in urban areas, along the national highways, state highways, villages identified as growth centres, freight complex, proposed major roads and police/security force services (for captive use only). | a) Petrol/diesel filling and servicing centre — May be permitted in central as well as sub-central business district, district centres, community centres (only filling station), residential and industrial use zones in urban areas, along the national highways, state highways, villages identified as growth centres, freight complex, proposed major roads and police/security force services (for captive use only). |
| 1) Locationi) Shall not be located on the road having right of way less than 30 m.ii) Shall be approved by the explosive/fire department.iii) Special cases in old city areas may be considered based on the approval by statutory authorities. | 1) Locationi) Shall not be located on the road having right of way less than 30 m.ii) Shall be approved by the explosive/fire department.iii) Special cases in old city areas may be considered based on the approval by statutory authorities. |
| 2) Area/Sizei) Only filling station | 30 m × 17 m |
| ii) Filling cum service station | 36 m × 30 m |
| iii) Filing cum service station cum workshop | 45 m × 36 m |
| iv) Filling station only for two and three wheelers | 18 m × 15 m |
| b) Compressed natural gas (CNG) filling centre — Permitted in all use zones (except in regional parks and developed district parks) and along the national highways, state highways and villages identified as growth centres, freight complex and on proposed major roads. | b) Compressed natural gas (CNG) filling centre — Permitted in all use zones (except in regional parks and developed district parks) and along the national highways, state highways and villages identified as growth centres, freight complex and on proposed major roads. |
| 1) Locationi) Shall not be located on the road having right of way less than 30 m.ii) Shall be approved by the explosive/fire department. | 1) Locationi) Shall not be located on the road having right of way less than 30 m.ii) Shall be approved by the explosive/fire department. |
| 2) Area/Size for CNG mother station (including building component — control rooms/office/dispensing room/store, pantry and W.C.) | 1 080 m² (36 m × 30 m) |
| c) LPG godowns/Gas godown — 1 for every 40 000 to 50 000 populationThe major concern for its storage and distribution is the location which shall be away from the residential areas and shall have open spaces all around as per The Explosive Rules, 2008 | c) LPG godowns/Gas godown — 1 for every 40 000 to 50 000 populationThe major concern for its storage and distribution is the location which shall be away from the residential areas and shall have open spaces all around as per The Explosive Rules, 2008 |
| 1) Capacity – 500 cylinders or 8 000 kg of LPG | 1) Capacity – 500 cylinders or 8 000 kg of LPG |
| 2) Area (inclusive of guard room) | 520 m² (26 m × 20 m) |
| d) Milk distribution booth — 1 milk booth for every 5 000 populationArea inclusive of service area | 150 m² |
| e) Fruit and vegetable distribution booth — 1 booth for every 5 000 population Area | 250 m² |
| 5.5.5 Police, Civil Defence and Home Guards | 5.5.5 Police, Civil Defence and Home Guards |
| Land Area Required, Min | Land Area Required, Min |
| a) Police station — 1 for every 90 000 populationArea (inclusive of essential residential accommodation; 0.05 ha additional to be provided for civil defence and home guards) | 1.50 ha |
| b) Police post — 1 for every 40 000 to 50 000 population(not served by a police station)Area (inclusive of essential residential accommodation) | 0.16 ha |
| c) District office and battalion — 1 for every 1 000 000 population | |
| Total area: | 4.80 ha |
| 1) Area for district office | 0.80 ha |
| 2) Area for battalion | 4.00 ha |
| d) Police line — 1 for every 2 000 000 population | |
| Area | 4.00 to 6.00 ha |
| e) District jail — 1 for every 1 000 000 population | |
| Area | 10.00 ha |
| f) Civil defence and home guards — 1 for every 1 000 000 population | |
| Area | 2.00 ha |
| g) Traffic and police control room | |
| Area | As per requirement |
| h) Police training institute/college — 1 at city level | |
| 1) Location — To be located in fringe areas | |
| 2) Area | 5.00 ha |
| j) Police firing range — 1 at city level | |
| 1) Location — To be located in fringe areas | |
| 2) Area | Up to 10.00 ha |
| k) Police camp including Central Police Organization/security forces (including Central security forces) | |
| Area | Up to 10.00 ha |
| m) Police booth (to be provided by transport planners) | |
| 1) Location — at major road intersections | |
| 2) Area | 10 to 12 m² |
5.5.6 Safety Management
| Land Area Required, Min | |
| a) Fire station — 1 for every 200 000 population or 1 within 5 to 7 km radius | |
| Area inclusive of residential accommodation | 1.00 ha |
| b) Sub fire station/fire post — 1 within a radius of 3 to 4 km | |
| Area inclusive of essential residential accommodation | 0.6 ha |
| c) Disaster management centre — 1 in each administrative zone | |
| Area | 1) 1.00 ha along with suitable open area |
| 2) 2.00 ha if soft parking, temporary shelter, parade ground, etc, included | |
| d) Fire training institute/college | |
| Area | 3.0 ha |
5.5.7 Telephone, Postal and Banking Facilities
| Land Area Required, Min | |
| a) Telephone and Communications | a) Telephone and Communications |
| 1) Telephone exchange of 40 000 lines — 1 for every 400 000 population Area | 4.00 ha |
| 2) Radio/TV station — 1 for every 500 000 to 800 000 population Area | 1700 m² |
| 3) Remote subscriber unit (RSU) — 1 for 3 km radius Area | 300 m² |
| b) Postal | b) Postal |
| 1) Post office counter without delivery — 1 for every 15 000 population Floor area to be provided in local shopping centre | 85 m² |
| 2) Head post office with delivery office — 1 for 250 000 population Area | 750 m² |
| 3) Head post office and administrative office — 1 for 500 000 population Area | 2500 m² |
| c) Banking | c) Banking |
| 1) Bank with extension counters with ATM facility — 1 for every 15 000 population | |
| i) Floor area for counters | 75 m² |
| ii) Floor area for ATM | 6 m² |
| 2) Bank with locker, ATM and other banking facilities — 1 for 100 000 population | |
| Area | 2 500 m² |
5.5.8 Sports Facilities
| Land Area Required, Min | |
|---|---|
| a) Divisional sports centre — 1 for 1 000 000 population Area | 20.00 ha |
| b) District sports centre — 1 for 100 000 population Area | 8.00 ha |
| c) Neighbourhood play area — 1 for 15 000 population Area | 1.50 ha |
| d) Residential unit play area — 1 for 5 000 population Area | 5 000 m2 |
5.5.9 Commercial Centres
| Land Area Required, Min | |
|---|---|
| a) Convenience shopping — 1 for every 5 000 populationArea | 1 500 m² |
| b) Local shopping including service centre — 1 for every 15 000 populationArea | 4 600 m² |
| c) Community centre with service centre — 1 for every 100 000 populationArea | 5.00 ha |
| d) District centre — 1 at district level/1 for every 500000 populationArea | 40.00 ha |
| e) Sub-city centre — 1 for every 2 500 000 to 5 000 000 populationArea | As per requirement |
| f) City centre — 1 for every 5 000 000 plus populationArea | As per requirement |
| g) Local wholesale market/Mandi — 1 for 1 000 000 populationArea | 10.00 ha |
| h) Weekly markets — 1 to 2 locations for every 100 000 population with 300to 400 units per location | |
| Parking and other open spaces with in the commercial centres can be so designed that weekly markets may operate in these areas during non-working hours. | |
| The area of informal sector should have suitable public conveniences and solid waste disposal arrangements. | |
| Area per location | 0.40 ha |
| j) Organized informal eating spaces — 1 for every 100 000 populationArea | 2 000 m² |
5.5.10 Electrical Sub-Station
| Land Area Required, Min | |
| a) 11 kV sub-station — 1 for 15 000 populationArea | 500 m² |
| b) 66 kV sub-station — 2 for 100 000 populationArea for each sub-station | 6 000 m² (that is, 60 m × 100 m) |
| c) 220 kV sub-station — 1 for 500 000 populationArea | 4.00 ha |
| 5.5.11 Transport | |
| Land Area Required, Min | |
| a) Three wheeler and taxi stand — 1 for 15 000 populationArea | 500 m² |
| b) Bus terminal — 1 for 100 000 populationArea | 4 000 m² |
| c) Bus depot — 1 for 500 000 populationArea | 2.00 ha |
| 5.5.12 Cremation/Burial GroundThe site shall not be in proximity to residential areas and should preferably be in urban extension. | |
| Land Area Required, Min | |
| a) Electric crematorium — 1 for large size townsArea | 2.00 ha |
| b) Cremation ground — 1 for 500 000 populationArea | 2.50 ha |
| c) Burial ground — 1 for 500 000 populationArea | 4.00 ha |
| 5.5.13 Dhobi Ghat | |
| Land Area Required, Min | |
| Dhobi ghat with appropriate arrangements for water and drainage facilitiesand it shall be ensured that the water bodies are not polluted as a result of such activities 1 for 100 000 populationArea | 5 000 m² |
5.6 Every layout or subdivision shall take into account the provisions of development plan and if the land is affected by any reservation for public purposes, the Authority may agree to adjust the location of such reservations to suit the development.
| i) | 12.0 | 200 |
| ii) | 15.0 | 400 |
| iii) | 18.0 | 600 |
| iv) | 24.0 | above 600 |
Further, in no case shall the means of access be lesser in width than the internal accessways in layouts and subdivision.
4.3.2.1.1 Footpath should be normally designed for a pedestrian Level of Service (LOS) B, thereby providing wide pedestrian facilities for safe, pleasant and comfortable walking. Under resource constraint, LOS C may be adopted for deciding the width of footpath mentioned in Table 2. The width of footpaths depends upon the expected pedestrian traffic and may be fixed with the help of the following norms subject to not being less than 1.8 m.
| Sl No. | Width of Foothpath | Design Flow in Number of Persons Per Hour | |||
| In Both Directions | All in One Direction | ||||
| m | LOS B(3) | LOS C(4) | LOS B(5) | LOS C(6) | |
| (1) | (2) | ||||
| i) | 1.8 | 1 350 | 1 890 | 2 025 | 2 835 |
| ii) | 2.0 | 1 800 | 2 520 | 2 700 | 3 780 |
| iii) | 2.5 | 2 250 | 3 150 | 3 375 | 4 725 |
| iv) | 3.0 | 2 700 | 3 780 | 4 050 | 5 670 |
| v) | 3.5 | 3 150 | 4 410 | 4 725 | 6 615 |
| vi) | 4.0 | 3 600 | 5 040 | 5 400 | 7 560 |
The land use adjacent to roads significantly influences generation of pedestrian traffic. Recommended width of footpath along various land uses are given in Table 3.
| Sl No. | Description | Width |
| m | ||
| (1) | (2) | (3) |
| i) | Minimum free walkway width and residential/mixed use areas | 1.8 |
| ii) | Commercial/Mixed use areas | 2.5 |
| iii) | Shopping frontages | 3.5 to 4.5 |
| iv) | Bus stops | 3 |
| v) | High intensity commercial areas | 4 |
4.3.2.1.2 The footpath shall be level, non-slip and continuous, and shall be provided with tactile orientation, kerb and kerb ramp. The footpath shall comply with the requirements given in B-2 other than for width which shall be as per 4.3.2.1.1.
The approach to the buildings from road/street/internal means of access shall be through paved pathway complying with requirements in B-2. The length of the pathway shall not be more than 30 m. The safety concern of cyclists and pedestrians should be addressed by encouraging the construction of segregated rights of way for bicycles and pedestrians.
4.3.2.2.1 In the case of special housing schemes for low income group and economically weaker section of society developed up to two storeyed row/cluster housing scheme, the main means of access through pedestrian pathway width shall be 3 m subject to provisions of 9.4.1(a). The pedestrian pathway shall not serve more than 8 plots on each side of the pathway; the length of the pathway shall be not more than 60 m.
4.3.3 The length of the main means of access shall be determined by the distance from the farthest plot (building) to the public street. The length of the subsidiary accessway shall be measured from the point of its origin to the next wider road on which it meets.
4.3.4 In the interest of general development of an area, the Authority may require the means of access to be of larger width than that required under 4.3 and 4.3.1.
4.3.5 In existing built-up areas in the case of plots facing street/means of access less than 4.5 m in width, the plot boundary shall be shifted to be away by 2.25 m from the central line of the street/means of accessway to give rise to a new street/means of accessway of 4.5 m width.
4.4 The means of access shall be levelled, metalled, flagged, paved, sewered, drained, channelled, lighted,
laid with water supply line and provided with trees for shade to the satisfaction of the Authority free of encroachment by any structure or fixture so as not to reduce its width below the minimum required under 4.3 and shall be maintained in a condition to the satisfaction of the Authority.
4.4.1 If any private street or any other means of access to a building is not levelled, metalled, flagged or paved, sewered, drained, channelled, lighted or laid with water supply line or provided with trees for shade to the satisfaction of the Authority, who may, with the sanction of the Authority, by written notice require the owner or owners of the several premises fronting or adjoining the said street or other means of access or abutting thereon or to which access is obtained through such street or other means of access or which shall benefit by works executed, to carry out any or more of the aforesaid requirements in such manner as he shall direct.
4.4.2 If any structure or fixture is set upon a means of access so as to reduce its width below the minimum required, the Authority may remove the same further and recover the expenses so incurred from the owner.
No premises other than highway amenities like petrol pumps, motels, etc, shall have an access direct from highways and such other roads not less than 52 m in width, which the Authority with the approval of the highway authority shall specify from time to time. For all other buildings, the access to the plot from the highway shall be only through a service road/lane as per the stipulation of the highway authority. The Authority shall maintain a register of such roads which shall be open to public inspection at all times during office hours. The portion of such roads on which direct access may be permitted shall be as identified in the Development Plan. However, in the case of existing development on highways/other roads referred to above, the operation of this clause shall be exempted. These provisions shall, however, be subject to the provisions of the relevant State Highway Act, and The National Highway Act, 1956.
4.6 For high rise buildings and special buildings (see Part 4 ‘Fire and Life Safety’ of the Code), the following additional provisions of means of access shall be ensured:
a) The width of the main street on which the building abuts shall not be less than 12 m and one end of this street shall join another street not less than 12 m in width.
b) The road shall not terminate in a dead end; except in the case of residential building, up to a height of 30 m.
c) The approach to the building and open spaces on all its sides shall be not less than 6 m in width, and a turning radius of minimum 9 m shall be provided for fire tender movement of fire tenders weighing up to 45 t. The same shall be hard surface capable of taking the mass of fire tender, weighing up to 45 t minimum. For heavier fire tenders, the minimum width, turning radius and the hard surface capable of taking the fire tender loads shall be as per the requirement laid down by the Fire Department. The layout for the open space for fire tender movement shall be done in consultation with the Chief Fire Officer of the city, which shall be kept free of obstructions and shall be motorable. The compulsory open spaces around the building shall not be used for parking.
d) The main entrance to the plot shall be of adequate width to allow easy access to the fire engine and in no case shall it measure less than 6 m. The entrance gate shall fold back against the compound wall of the premises, thus leaving the exterior accessway within the plot free for movement of fire tender. If the main entrance at the boundary wall is built over, the minimum clearance shall be 4.5 m.
4.6.1.1 Podium is a horizontal projection (platform) extending beyond the building footprint on one or more sides, and may consist of one or more levels (see Fig. 8A).
Podium may be used for the following purposes:
a) Parking of vehicles — When used for parking, one WC, two urinals and two washbasins for every 500 cars or part thereof, shall be provided on each podium floor. At least one accessible toilet complying with the requirements given in B-9 shall be provided preferably near the accessible parking.
Provision for driver's rest room for non-residential building shall be made.
b) Fire and building services/utilities in accordance with the provisions of other Parts/Sections of the Code.
c) Topmost podium slab which is open to sky maybe landscaped and/or be used as recreational open space; subject to provision of 1.6 m high parapet wall.
d) Other habitable uses may be allowed by counting it in FAR subject to light, ventilation and fire safety requirements.
Uses proposed in (a) to (c), shall not be counted towards FAR.
Following requirements shall be satisfied for buildings constructed on podium:
a) A podium may be permitted in a plot of area 1 500 m² or more.
b) A podium, if provided with ramp, may be permitted in one or more levels, however the total height shall not exceed 30.0m above ground level.
c) In case a podium is not provided with ramp, but provided with car lift only, the same may also be permitted in one or more levels, however, the total height shall not exceed 9.0 m above ground level.
d) Requirements for ramp for vehicles (see Fig. 8B):
One way ramp of clear width of minimum 3.0 m and two way ramp with clear width of minimum 6.0 m shall be provided for LMV.
One way ramp of clear width of minimum 4.5 m and two way ramp with clear width of minimum 9.0 m shall be provided for LCV.
One way ramp of clear width of minimum 6.0 m and two way ramp with clear width of minimum 12.0 m shall be provided for HMV.
Ramp slope shall be maximum 1 in 8.
After a 40 m length of continuous ramp, a flat surface of minimum 6.0 m length shall preferably be provided (see Fig. 8B).
If podium is accessible to fire tender, minimum 7.5 m wide ramp shall be required for fire engine access with maximum slope of 1 in 10.
e) Podium shall not be permitted in required minimum front open space.
f) Podium, if accessible to fire tender, shall be so designed so as to take the load of fire tender weighing up to 45 t minimum or as per the requirement laid down by the Fire Department.
g) Requirement of accessibility for elders and persons with disabilities shall be ensured in compliance with the provisions of Annex B which may require providing ramps with specified gradient or accessible lifts for access to different levels.
a) Buildings having height more than 15 m above ground level shall necessarily be accessible by fire tender, as follows (see Fig. 9A):
For buildings having floor area less than 10 000 m² , fire tenders shall have access to at least one-third of the perimeter of building which shall be minimum 6.0 m wide and having 9.0 m turning radius.
For buildings having floor area more than 10 000 m², fire engine shall have an access to at least to half of the perimeter of building which shall be minimum 6.0 m wide and having 9.0 m turning radius.
b) If podium is not accessible by fire tender, the podium may be such that it is not extended beyond the building footprint to an extent more than 11.0 m on the side where fire tender access is provided (see Fig. 9B and Fig. 9C). Such restriction shall not apply in case podium is accessible by fire engine (see Fig. 9D).
c) Minimum 6.0 m driveway width and 9.0 m width at turning shall be available for fire tender movement all around the podium.
NOTE — The width and turning radius of ramp for fire tender access, and requirements of motorable open space for fire tender movement given above pertain to fire tender weighing up to 45 t and its operability. For heavier fire tenders, these shall be as per the requirement laid down by the Fire Department [see also 4.6 (c)].
4.7 Cul-de-sacs giving access to plots and extending from 150 m to 275 m in length with an additional turning space at 150 m will be allowed only in residential areas, provided cul-de-sacs would be permissible only on straight roads and further provided the end of cul-de-sacs shall be higher in level than the level of the starting point of such dead end road. The turning space, in this case shall be not less than 81 m² in area, with no dimension less than 9 m.
For intersection junctions of roads meeting at right angles as well as other than right angles, the rounding off or cut off or splay or similar treatment shall be done, to the approval of the Authority, depending upon the width of roads, the traffic generated, the sighting angle, etc, to provide clear sight distance.
4.9 The building line shall be set back at least 3m from internal means of access in a layout of buildings in a plot subject to provisions of 8.2.1.
FIG. 9 — (Continued)


be provided in one place or planned out for the use of the community in clusters or pockets.
5.1.1 The community open spaces shall be provided catering to the needs of area of layout, population for which the layout is planned and the category of dwelling units. The following minimum provision shall be made:
a) 15 percent of the area of the layout, or
b) 0.3 to 0.4 ha/1 000 persons; for low income housing, the open spaces shall be 0.3 ha/1 000 persons.
5.2 No recreational space shall generally be less than 450m².
5.2.1 The minimum average dimension of such recreational space shall be not less than 7.5m; if the average width of such recreational space is less
than 24 m, the length thereof shall not exceed 2.5 times the average width. However, depending on the configuration of the site, commonly open spaces of different shapes may be permitted by the Authority, as long as the open spaces provided serve the needs of the immediate community contiguous to the open spaces.
5.2.2 In such recreational spaces, a single storeyed structure as pavilion or gymnasia up to 25m² in area may be permitted; such area may be excluded from FAR calculations.
5.3 Each recreational area and the structure on it shall have an independent means of access. Independent means of access may not be insisted upon if recreational space is approachable directly from every building in the layout. Further, the building line shall be at least 3 m away from the boundary of recreational open space.
6.1 No building shall be constructed on any site, on any part of which there is deposited refuse, excreta or other offensive matter objectionable to the Authority, until such refuse has been removed therefrom and the site has been prepared or left in a manner suitable for building purposes to the satisfaction to the Authority.
Wherever the dampness of a site or the nature of the soil renders such precautions necessary, the ground surface of the site between the walls of any building erected thereon shall be rendered damp-proof to the satisfaction of the Authority.
Any land passage or other area within the curtilage of a building shall be effectively drained by surface water drains or other means.
6.3.1 The written approval of the Authority shall be obtained for connecting any subsoil or surface water drain to a sewer.
An overhead line shall not cross an existing building as far as possible and no building shall be constructed under an existing overhead line. No accessible point from any Verandah, balcony, or the like shall be allowed to be erected or re-erected or any additions or alterations made to a building not having the following minimum clearances from an overhead electric supply line, in accordance with the current Central Electricity Authority (Measures Relating to Safety and Electric Supply) Regulations, 2010 as amended from time to time:
a) Clearance of buildings from lines of voltages and service lines not exceeding 650V
An overhead line shall not cross over an existing building as far as possible and no building shall be constructed under an existing overhead line.
Where an overhead line of voltage not exceeding 650 V passes above or adjacent to or terminates on any building, the following minimum clearances from any accessible point, on the basis of maximum sag, shall be observed:
i) For any flat roof, open balcony, Verandah roof and lean-to-roof:
a) where the line passes above the building, a vertical clearance of 2.5 m from the highest point, and
b) when the line passes adjacent to the building, a horizontal clearance of 1.2 m from the nearest point, and
ii) For pitched roof:
a) where the line passes above the building, a vertical clearance of 2.5m immediately under the line, and
b) when the line passes adjacent to the building, a horizontal clearance of 1.2m.
The horizontal clearance shall be measured when the line is at a maximum deflection from the vertical due to wind pressure.
Any conductor so situated as to have a clearance less than that specified above shall be adequately insulated and shall be attached at suitable intervals to a bare earthed bearer wire having a breaking strength of not less than 350 kg.
b) Clearances from buildings of lines of voltages exceeding 650 V
no building shall be constructed under an existing overhead line.
i) For lines of : 3.7 m upto and voltages including 33 kV; exceeding and 650 V
ii) For lines of : 3.7 m plus 0.30 m voltages for every additional 33 kV or part thereof. exceeding 33 kV
The horizontal clearance between the nearest conductor and any part of such building shall, on the basis of maximum deflection due to wind pressure, be not less than:
i) For lines of : 1.2 m voltages exceeding 650 V and up to and including 11 kV
ii) For lines of : 2.0 m voltages exceeding 11 kV and up to and including 33 kV
iii) For lines of : 2.0 m plus voltages exceeding 0.3 m for every additional 33 kV or part thereof
| Sl No. | d.c.Voltage | Vertical Clearance | Horizontal Clearance |
|---|---|---|---|
| kV | m | m | |
| (1) | (2) | (3) | (4) |
| i) | 100 | 4.6 | 2.9 |
| ii) | 200 | 5.8 | 4.1 |
| iii) | 300 | 7.0 | 5.3 |
| iv) | 400 | 7.0 | 6.2 |
| v) | 500 | 9.1 | 7.4 |
| vi) | 600 | 10.3 | 8.6 |
| vii) | 800 | 12.4 | 10.7 |
Distance of site from the normal edge of water course/area may be specified by the Authority, keeping in view the normal maximum flood/tide level.
Each plot shall have a minimum size/frontage corresponding to the type of development as given below:
| SlNo.(1) | Type of Development(2) | Plot Size m² (3) | Frontagem(4) |
| i) | Detached building | Above 250 | above 12 |
| ii) | Semi-detachedbuilding | 125-250 | 8 to 12 |
| iii) | Row type building | 50-125 | 4.5 to 8 |
| NOTE — For low income housing,see 14. | |||
6.6.1.1 The minimum size of the site for group housing development shall be as given in the Master Plan and local development control rules.
The size of the plot shall not be less than 300m² and its width shall not be less than 15m.
The minimum size of plots for buildings for other uses not covered under 5.5 shall be as decided by the Authority. Various requirements with respect to cinema buildings shall be in accordance with the good practice [3(2)].
Every room intended for human habitation shall abut on an interior or exterior open space or an open Verandah open to such interior or exterior open space.
8.1.1 The open spaces inside and around a building have essentially to cater for the lighting and ventilation requirements of the rooms abutting such open spaces, and in the case of buildings abutting on streets in the front, rear or sides, the open spaces provided shall be sufficient for the future widening of such streets.
The open spaces shall be separate or distinct for each building and where a building has two or more wings, each wing shall have separate or distinct open spaces for the purposes of lighting and ventilation of the wings.
34
However, separation between accessory and main buildings more than 7 m in height shall not be less than 1.5 m; for buildings up to 7 m in height no such separation shall be required.
8.1.3 The open space shall be the minimum distance measured between the front, rear and side of the building and the respective plot boundaries. The front, rear and side of the building shall be the point of the building nearest to the boundary.
Buildings are classified based on occupancy and types of construction.
7.1 For the purpose of the Code, the following shall be the occupancy classification and types of construction; for more detailed information, reference may be made to Part 4'Fire and Life Safety' of the Code.
a) Residential;
b) Educational;
c) Institutional;
d) Assembly;
e) Business;
f) Mercantile (will include both retail and wholesale stores);
g) Industrial (will include low, moderate and high fire hazards);
h) Storage; and
j) Hazardous.
a) Type 1,
b) Type 2,
c) Type 3, and
d) Type 4.