This Part deals with the development control rules and general building requirements to ensure health and safety of the public.
BUREAU OF INDIAN STANDARDS
This Code (Part 3) covers development control rules, including such aspects as subdivision and layout rules, land use classifications, open spaces, area and height limitations, means of access, and parking spaces. This Part also covers the general building requirements, including those of various parts of buildings.
It is expected that for proper coordination and enforcement of the development control rules and general building requirements, the departments concerned, namely, the town and country planning department, urban development authority, urban local body and the building department, will coordinate the total development and building activity at both organizational and technical levels.
Particular attention is invited to Table 5 on floor area ratio (FAR) limitations. It is emphasized that the floor area of a single storey building is limited in absolute terms by the type of construction and occupancy class. Also, the absolute floor areas for different types of construction and different occupancies have a definite ratio among them. The ratios as recommended in the American Iron and Steel Institute Publication of 1961 ‘Fire protection through modern building codes’ have been generally adopted in this Part and Table 5 has been developed on this basis. This, Table 5 is repeated in Part 4 ‘Fire and Life Safety’ of the Code also, for convenience of reading.
Limitation of areas and heights of buildings are regulated by specifying floor area ratio (FAR) or floor space index (FSI) and ground coverage. The significance of the contribution of different types of construction giving different fire resistances has not been taken cognizance of in specifying FAR for different occupancies, in the present development control rules and municipal byelaws of the country. Table 5, therefore, gives the comparative ratios of FAR between types of buildings and occupancy classes and these have been specified mainly from the fire protection aspect of buildings. To arrive at the actual FAR for different buildings coming up in different areas, the Authority should further modify them, by taking into consideration other aspects like population density of any area, parking facilities required, the traffic load (road width) and the services available. The heights of buildings shall also be regulated, keeping in view the local fire fighting facilities.
In some state byelaws, the FAR (or FSI) has been expressed in the form of percentage. However, the Committee responsible for the preparation of this Code is of the opinion that, it being a ratio should be expressed only in the form of a ratio, as done in this Part.
It is particularly to be borne in mind by the Authority that the ratios are definitive and it may assess the particular FAR for a type of construction and for an occupancy and establish a new table, but retaining the comparative ratios as given in Table 5.
Keeping in view the enormous problems faced by the country with regard to the ever increasing squatter settlements/pavement dwellers in urban areas (cities of all sizes), it is imperative that all the urban local bodies and urban development authorities sooner or later evolve schemes for their rehabilitation. The resources are meagre and the problems are enormous. There has been a tendency on the part of a number of urban development authorities/urban local bodies to link space norms with affordability. Affordability is an important criterion but at the same time a public agency may not ignore the basic minimum needs of the family to be housed (including the mental, physical and social health of the marginalized groups, which is linked with shelter). The urban local bodies shall have to evolve appropriate policies for their integration with the overall development process and generate/allocate resources and more importantly adopt a planning process, which are people friendly and inclusive. Therefore, keeping in view the needs of low income housing, to cater to Economically Weaker Sections of Society (EWS) and Low Income Group (LIG), the requirements on planning, design of layout/shelter have been rationalized and the same are provided in this Part. This information is based on the provisions of IS 8888 (Part 1):1993 'Guide for requirements of low income housing: Part 1 Urban areas (first revision)'.
It is important that the fruits of development are equally shared by all cross-section of the society irrespective of their age and abilities. This Code therefore covered provisions for buildings and built environment to ensure a barrier-free
environment for elders and persons with disabilities. The goal of barrier free design is to provide an environment that supports the independent functioning of individuals so that they can participate without assistance, in everyday activities. It has been intended to progressively update these provisions and make the same more effective and elaborate based on experience gained with the implementation of the Code and feedback received from stakeholders. As a conscious decision, opportunity has been taken in this revision of the Code to further mainstream the issue of barrier free environment by covering the requirements at greater length. The concept of universal design has also been included herein that promotes the usability of built environment by all without discrimination. It is worthwhile to note that The Persons with Disabilities (Equal Opportunities, Protection of Rights and Full Participation) Act, 1995 in its Chapter VIII ‘Non-Discrimination’, Section 44 to 46 mandates accessibility in public buildings and transportation systems. National policy for persons with disabilities also emphasizes the role of barrier-free environment as one that enables people with disabilities to move about safely and freely, and use the facilities within the built environment. Therefore, to the maximum extent possible, buildings/places/transportation systems for public use should be made barrier free. India has also signed and ratified the UN Convention on Rights of Persons with Disabilities that casts an obligation on the member states in its Article 9‘Accessibility’, to enable persons with disabilities to live independently and participate fully in all aspects of life.
Further, city development process would need a dynamic approach to take care of urban renewal and also development needs in dense core areas of the cities. Innovative approaches in planning and design with participatory models of public private-people's partnership become necessary to solve the emerging development needs. With this in view, many city development authorities have evolved innovative planning and development tools like transferable development rights (TDR) where the developer would receive a portion of the development rights in a new location, keeping in view the constraints in the existing land area and the development potential. Such development rights may be transferred into outskirts or new developed areas where land availability is assured. This would encourage the professionals and developers to participate in urban renewal and at the same time ensure that the developments in both the inner core areas and new areas take place in a planned manner. The TDR concept should be increasingly encouraged by the authority dealing with urban renewal, redevelopment projects including housing and redevelopment projects for slum dwellers.
Transit oriented development (TOD), as a concept, integrates land uses and mass transportation such as bus rapid transit (BRT) and rail based transit like metro-rail, mono-rail, light-rail, ring-rail, etc. The basic objective is to plan cities in a manner where people conveniently walk and use public transport for most of their trips and, thus, reduce dependence on private mode and provide benefits to the city which include reduction in congestion, delays and accidents on roads; reduction of pollution caused by automobiles; and improvement in liveability, mobility and convenience of the citizens. TOD makes city compact and increases its efficiency and functioning. The TOD is desirable as it, (a) reduces/discourages private vehicle dependency and induces public transport use though planning, designing, policy measures and enforcement; and (b) provides easy access to public transport, within walking distance, to a majority of people, through densification and enhanced connectivity.
Some of the planning and design principles applied to create TOD include creation of,
a) pedestrian and non-motorized transport friendly environment;
b) efficient public and para-transport system supporting the transit system;
c) multi-modal interchange and street connectivity;
d) mixed land uses and appropriate intensity of development; and
e) well designed and integrated parking thus requiring reduced parking requirements in comparison to the norms given in this Part.
TOD concept may be suitable for all newly planned green field cities. However, it can also be applied to existing brown field cities where new expansion/development are taken up backed up with effective mass rapid transport system and new nodes. The Authorities may take up appropriate studies to evaluate suitability of TOD concept under relevant situations.
Urbanization in India is taking place at a rapid pace. As per the 2011 Census, 31.16 percent of the country's population resides in urban areas. This figure was 27.8 percent in 2001. The urban component is expected to rise to around 40 percent by 2020. As Indian cities continue to grow demographically and spatially, the challenge of improving urban infrastructure is enormous. While the number of urban centres has increased manifold between 1901 and 2011, the urban population increased six fold, resulting in a top-heavy urban settlement hierarchy with a large number of primate settlements. It is expected that the number of towns and cities which was 7 933 as per Census, 2011 is likely to cross the 10 000 mark in next two decades. As a result of liberalization, the demographic
trends of urbanization are accompanied by both challenges and opportunities in the management and financing of urban development.
Unprecedented urbanization has been fuelled by rapid economic growth and even more rapid industrialization especially in the past three decades or so. With globalization, this trend of rapid economic growth and urbanization is likely to accentuate further. In 1901, Kolkata was the only metropolitan city (million plus) in the country. The number of metropolitan cities increased to 5 in 1951, 12 in 1981, 23 in 1991, 35 in 2001 and 53 in 2011. The 53 metropolitan cities together account for a population of about 158 million in 2011, that is, 42 percent of urban population of the country. It is expected that this number would be about 85 by 2051.
Going by the present trends, by 2051, India would be the most populous country with 1.70 billion people and 0.19 ha per capita land availability. By 2051, 820 million people will live in urban settlements constituting about 50 percent of the total population. Cities in the country would emerge as centres of both hope and despair: while being engines of economic and social development they may also be congested centres of poverty and environmental degradation. The million plus cities constitute 42 percent of the total urban population, while the Class I (more than 1 lakh population) towns constituted 60.04 percent, followed by 11 percent in Class II (50 000-100 000 population) towns, 15.4 percent in Class III (20 000- 50 000 population) towns and the rest 13.56 percent constituted by Class IV, V and VI towns (less than 20 000 population).
Further, in the Indian practice, mega-cities (cities over 50 lakhs population) are 8 in number; metro-cities (cities having 10 to 50 lakhs population) are 45 in number. These 53 cities above 10 lakhs population is likely to be above 70 by 2021. The other cities are either small or medium towns or cities with different population limits. Urbanization in above cities and towns (mega-cities, metro-cities, small and medium towns and cities) will be different in nature and the development challenges are also different keeping in view the extent of urbanization, industrialization, commercialization and the nature of transportation needs. Therefore, the Code provisions should be appropriately utilized depending upon the need of hierarchy of cities for which the administrative and technical requirements have been covered in the Code for various facets of the activity.
The first version of this Part was formulated in 1970. As a result of incorporation of this Part in the revised development control rules and building byelaws of some municipal corporations and municipalities, some useful suggestions had emerged. The first revision of this Part was brought out in 1983, where these suggestions were incorporated to the extent possible. The major modifications incorporated in the first revision included:
a) Addition of development control rules giving guidance on means of access, community spaces and other aspects required for planning layouts.
b) Addition of provisions regarding plot sizes and frontage for different types of buildings, such as detached, semi-detached, row type and special housing schemes.
c) Requirements of open spaces for other occupancies, such as educational, institutional, assembly, industrial buildings, etc were included.
d) Provisions relating to interior open space were elaborated, including requirements for ventilation shaft.
e) Requirements of open spaces for group housing development were covered.
f) Requirements of off-street parking spaces were covered.
g) Requirements for greenbelts and landscaping including norms for plantations of shrubs and trees were covered.
h) Requirements of certain parts of buildings, such as loft, store room, garage, basement, chimney, parapet, cabin, boundary wall, wells, septic tanks, office-cum-letter box room, meter room were included.
j) Special requirements of low income housing were covered.
The term Development Control Rules used in this Part encompasses the related aspects comprehensively with a view to promoting orderly development of an area.
The major modifications incorporated in the second revision included:
a) Terminology given in this Part were made exhaustive by incorporating definitions of additional terms used, such as access, chimney, to erect, etc, and number of terms pertaining to cluster planning for housing.
b) Detailed planning norms/open spaces for various amenities such as educational facilities, health care facilities, socio-cultural facilities, distribution services, police, civil defence and home guards, and fire services were included.
c) Off-street parking requirements were also included for cities with population, (1) between 1 000 000 and 5 000 000, and (2) above 5 000 000 (see Annex A).
d) Special requirements for low income housing were modified and updated based on the revision of concerned Indian Standard namely IS 8888:1978 as IS 8888 (Part 1):1993 ‘Guide for requirements of low income housing : Part 1 Urban area (first revision)’. Single room dwelling was discouraged, guidelines for water seal latrine were incorporated, and cluster planning approach were recommended.
e) Requirements for cluster planning for housing were added based on the guidelines given in IS 13727:1993 'Guide for requirements of cluster planning for housing'.
f) Special requirements for low income housing for rural habitat planning were added.
g) Special requirements for development planning in hilly areas were added.
h) The requirements for buildings and facilities for the physically challenged were revised, with listing of additional categories of physically challenged; modifications in requirements of ramps, stairs, doors, handrails and controls; and incorporation of additional requirements regarding windows.
In this third revision, following major modifications have been incorporated:
a) Definitions of additional terms have been included and some of the existing definitions have been modified in the terminology clause.
b) Reference of IS 3861 : 2002 ‘Method of measurement of plinth, carpet and rentable areas of buildings (second revision)’ has been added for correct interpretation of plinth area and built-up area.
c) Land use classification has been modified.
d) A new clause on footpaths giving guidance on width of footpath to be adopted based on expected pedestrian traffic as also recommended width of footpath corresponding to adjacent land use, has been added.
e) Provisions on Transferable Development Rights (TDR) has been included.
f) Provisions on Accommodation Reservation (AR) have been included.
g) Provisions for buildings on podium including permitted uses in podium, general requirements for the same and requirements for fire tender movement have been incorporated under the clause on means of access.
h) Planning norms for amenities have been modified and new amenities have been covered.
j) Requirements for minimum clearances from an overhead electric supply line have been modified based on current Central Electricity Authority (Measures Relating to Safety and Electric Supply) Regulations, 2010 taking into account effect of sag and wind pressure.
k) Provisions for sunken courtyard have been added for meeting the light and ventilation requirements for basement area.
m) For height restrictions in the vicinity of aerodromes, reference to concerned notification of the Ministry of Civil Aviation, Govt of India has been made.
n) Considering that high density developments are being increasingly promoted in master plans and development policies, maximum coverage and floor area ratio for densities 200 to 400 dwelling units/hectare have been added.
p) Provisions for underground or multi-storeyed parking as also mechanized parking of vehicles has been included.
q) Provisions relating to basements have been reviewed and updated keeping in view the latest developments.
r) Requirements for accessibility in buildings and built environment for elders and persons with disabilities have been thoroughly revised and updated.
s) Provisions for solar energy utilization have been included.
t) Norms for off-street parking spaces have been revised.
u) Special requirements for low income housing have been updated.
w) Special requirements for development planning in hilly areas have been updated.
The information contained in this Part is also based on the following Indian Standards:
IS 4963 : 1987
Recommendations for buildings and facilities for physically handicapped (first revision)
IS 8888 (Part 1): 1993 Guide for requirements of low income housing : Part 1 Urban area (first revision)
IS 13727 : 1993 Guide for requirements of cluster planning for housing
IS 4963 : 1987 is under revision, the provisions of revised version of this standard shall be referred when available. In revising the provisions of this Part, assistance has also been derived from the following publications:
Urban and Regional Development Plans Formulation and Implementation Guidelines, 2014, Town and Country Planning Organization
IRC : 103-2012 Guidelines for Pedestrian Facilities (first revision)
ISO 21542 : 2011 Building construction — Accessibility and usability of the built environment
Planning a barrier free environment, 2011 prepared by Office of the Chief Commissioner for Persons with Disabilities, Ministry of Social Justice and Empowerment, Government of India
Harmonized guidelines and space standards for barrier free built environment for persons with disability and elderly persons, Ministry of Urban Development, 2016
All standards cross-referred here or in the main text of this Part, are subject to revision. The parties to agreement based on this Part are encouraged to investigate the possibility of applying the most recent editions of the standards.
For the purpose of deciding whether a particular requirement of this Part of the Code is complied with, the final value, observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance with IS 2 : 1960 ‘Rules for rounding off numerical values (revised)’. The number of significant places retained in the rounded off value should be the same as that of the specified value in this Part.
For the purpose of this Part, the following definitions shall apply.
2.1 Access — A clear approach to a plot or a building.
2.2 Accessory Use — Any use of the premises subordinate to the principal use and customarily incidental to the principal use.
2.3 Alteration — A change from one occupancy to another, or a structural change, such as an addition to the area or height, or the removal of part of a building, or any change to the structure, such as the construction of, cutting into or removal of any wall, partition, column, beam, joist, floor (including a mezzanine floor) or other support, or a change to or closing of any required means of ingress or egress or a change to the fixtures or equipment.
2.4 Approved — Approved by the Authority having jurisdiction.
2.5 Authority Having Jurisdiction — The Authority which has been created by a statute and which for the purpose of administering the Code/Part may authorize a committee or an official to act on its behalf; hereinafter called the ‘Authority’.
2.6 Back-to-Back Cluster — Clusters when joined back to back and/or on sides (see Fig. 1).

FIG. 1 BACK TO BACK CLUSTER
2.7 Balcony — A horizontal projection, with a handrail or balustrade or a parapet, to serve as passage or sitting out place.
2.8 Basement or Cellar — The lower storey of a building, below or partly below ground level.
2.9 Building — Any structure for whatsoever purpose and of whatsoever materials constructed and every part thereof, whether used as human habitation or not and includes foundation, plinth, walls, floors, roofs, chimneys, plumbing and building services, fixed platforms, Verandah, balcony, cornice or projection, part of a building or anything affixed thereto or any wall enclosing or intended to enclose any land or space and signs and outdoor display structures. Tents, Shamianahs, tarpaulin shelters, etc, erected for temporary and ceremonial occasions with the permission of the Authority shall not be considered as building.
2.10 Building, Height of — The vertical distance measured in the case of flat roofs, from the average level of the ground around and contiguous to the building or as decided by the Authority to the terrace of last livable floor of the building adjacent to the external walls; and in the case of pitched roofs, up to the point where the external surface of the outer wall intersects the finished surface of the sloping roof; and in the case of gables facing the road, the mid-point between the eaves level and the ridge. Architectural features serving no other function except that of decoration shall be excluded for the purpose of measuring heights. See 9.4.2.1.
2.11 Building Envelope — The horizontal spatial limits up to which a building may be permitted to be constructed on a plot.
2.12 Building Line — The line up to which the plinth of a building adjoining a street or an extension of a street or on a future street may lawfully extend. It includes the lines prescribed, if any, in any scheme. The building line may change from time to time as decided by the Authority.
2.13 Cabin — A non-residential enclosure constructed of non-load bearing partition.
2.14 Canopy — A projection over any entrance.
2.15 Carpet Area — The covered area of the usable rooms at any floor level (excluding the area of the wall) {see accepted standard [3(1)]}.
2.16 Chhajja — A sloping or horizontal structural overhang usually provided over openings on external walls to provide protection from sun and rain.
2.17 Chimney — An upright shaft containing one or more flues provided for the conveyance to the outer air of any product of combustion resulting from the operation of heat producing appliance or equipment employing solid, liquid or gaseous fuel.
2.18 Chowk or Courtyard — A space permanently open to the sky, enclosed fully or partially by building and may be at ground level or any other level within or adjacent to a building.
2.19 Chowk, Inner — A chowk enclosed on all sides.
2.20 Chowk, Outer — A chowk one of whose sides is not enclosed.
2.21 Closed Clusters —Clusters with only one common entry into cluster open space (see Fig. 2).

FIG. 2 CLOSED CLUSTER
2.22 Cluster — Plots or dwelling units or housing grouped around an open space (see Fig. 3). Ideally housing cluster should not be very large. In ground and one storeyed structures not more than 20 houses should be grouped in a cluster. Clusters with more dwelling units will create problems in identity, encroachments and of maintenance.
2.23 Cluster Court Town House — A dwelling in a cluster plot having 100 percent or nearly 100 percent ground coverage with vertical expansion, generally limited to one floor only and meant for self use.
2.24 Cluster Plot — Plot in a cluster.
2.25 Cooking Alcove — A cooking space having direct access from the main room without any inter-communicating door.
2.26 Covered Area — Ground area covered by the building immediately above the plinth level. The area covered by the following in the open spaces is excluded

FIG. 3 CLUSTER
from covered area (see Table 5):
a) Garden, rockery, well and well structures, plant nursery, water pool, swimming pool (if uncovered), platform round a tree, tank, fountain, bench, Chabutra with open top and unenclosed on sides by walls and the like;
b) Drainage culvert, conduit, catch-pit, gully pit, chamber, gutter and the like;
c) Compound wall, gate, unstoreyed porch and portico, canopy, slide, swing, uncovered staircase, ramps areas covered by Chhajja and the like; and
d) Watchmen's booth, pump house, garbage shaft, electric cabin or sub-stations, and such other utility structures meant for the services of the building under consideration.
NOTE — For the purpose of this Part, covered area equals the plot area minus the area due for open spaces.
Plots/dwelling units when located along a pedestrianized or vehicular ‘cul-de-sac’ road (see Fig. 4).

FIG. 4 CUL-DE-SAC CLUSTER
2.28 Density — The residential density expressed in terms of the number of dwelling units per hectare.
NOTE — Where such densities are expressed exclusive of community facilities and provision of open spaces and major roads (excluding incidental open spaces), these will be net residential densities. Where these densities are expressed taking into consideration the required open space provision and community facilities and major roads, these would be gross residential densities at neighbourhood level, sector level or town level, as the case may be. The provision of open spaces and community facilities will depend on the size of the residential community.
Incidental open spaces are mainly open spaces required to be left around and in between two buildings to provide lighting and ventilation.
2.29 Detached Building — A building detached on all sides.
2.30 Development — ‘Development’ with grammatical variations means the carrying out of building, engineering, mining or other operations, in, or over, or under land or water, on the making of any material change, in any building or land, or in the use of any building, land, and includes redevelopment and layout and subdivision of any land; and ‘to develop’ shall be construed accordingly.
2.31 Drain — A conduit, channel or pipe for the carriage of storm water, sewage, waste water or other water borne wastes in a building drainage system.
2.32 Drainage — The removal of any liquid by a system constructed for the purpose.
2.33 Dwelling Unit/Tenement — An independent housing unit with separate facilities for living, cooking and sanitary requirements.
2.34 Escalator — A power driven, inclined, continuous moving stairway used for raising or lowering passengers.
2.35 Exit — A passage, channel or means of egress from any building, storey or floor area to a street or other open space of safety.
2.36 External Faces of Cluster — Building edges facing the cluster open spaces.
2.37 Fire Separation — The distance in metres measured from the external wall of the building concerned to the external wall of any other building on the site, or from other site, or from the opposite side of a street or other public space for the purpose of preventing the spread of fire.
2.38 Floor — The lower surface in a storey on which one normally walks in a building. The general term ‘floor’ unless specifically mentioned otherwise shall not refer to a ‘mezzanine floor’.
2.39 Floor Area Ratio (FAR) — The quotient obtained
by dividing the total covered area (plinth area) on all floors by the area of the plot:
2.40 Gallery — An intermediate floor or platform projecting from a wall of an auditorium or a hall providing extra floor area, additional seating accommodation, etc. It shall also include the structures provided for seating in stadia.
2.41 Garage, Private — A building or a portion thereof designed and used for parking of private owned motor driven or other vehicles.
2.42 Garage, Public — A building or portion thereof, other than a private garage, designed or used for repairing, servicing, hiring, selling or storing or parking motor driven or other vehicles.
2.43 Group Housing — Housing for more than one dwelling unit, where land is owned jointly (as in the case of cooperative societies or the public agencies, such as local authorities or housing boards, etc) and the construction is undertaken by one Agency.
2.44 Group Open Space — Open space within a cluster.
Group open space is neither public open space nor private open space. Each dwelling unit around the cluster open space have a share and right of use in it. The responsibility for maintenance of the same is to be collectively shared by all the dwelling units around.
2.45 Habitable Room — A room occupied or designed for occupancy by one or more persons for study, living, sleeping, eating, kitchen if it is used as a living room, but not including bathrooms, water-closet compartments, laundries, serving and store pantries, corridors, cellars, attics, and spaces that are not used frequently or during extended periods.
2.46 Independent Cluster — Clusters surrounded from all sides by vehicular access roads and/or pedestrian paths (see Fig. 5).

FIG. 5 INDEPENDENT CLUSTER
2.47 Interlocking Cluster — Clusters when joined at back and on sides with at least one side of a cluster common and having some dwelling units opening onto or having access from the adjacent clusters.
Dwelling units in such clusters should have at least two sides open to external open space. Houses in an interlocking cluster may have access, ventilation and light from the adjacent cluster and should also cater for future growth (see Fig. 6).

FIG. 6 INTERLOCKING CLUSTER
2.48 Internal Faces of Cluster — Building edges facing the adjacent cluster open space (as in case of interlocking cluster) of the surrounding pedestrian paths or vehicular access roads.
2.49 Ledge or Tand — A shelf-like projection, supported in any manner whatsoever, except by means of vertical supports within a room itself but not having projection wider than 1 m.
2.50 Lift — An appliance designed to transport persons or materials between two or more levels in a vertical or substantially vertical direction by means of a guided car or platform. The word ‘elevator’ is also synonymously used for ‘lift’.
2.51 Loft — A structure providing intermediate storage space in between two floors with a maximum height of 1.5 m, without having a permanent access.
2.52 Master Plan — A master plan formulated under any relevant act (Town and Country Planning or Development Act or Municipal Act) for any town, approved and notified by the State Government.
2.53 Mezzanine Floor — An intermediate floor between two floors of any storey forming an integral part of floor below.
2.54 Occupancy or Use Group — The principal occupancy for which a building or a part of a building is used or intended to be used; for the purposes of classification of a building according to occupancy; an occupancy shall be deemed to include subsidiary occupancies which are contingent upon it.
2.55 Occupancy, Mixed — A multiple occupancy where the occupancies are intermingled.
2.56 Open Clusters — Clusters where cluster open spaces are linked to form a continuous open space (see Fig. 7).

FIG. 7 OPEN CLUSTER
2.57 Open Space — An area, forming an integral part of the plot, left open to the sky.
NOTE — The open space shall be the minimum distance measured between the front, rear and side of the building and the respective plot boundaries.
2.58 Open Space, Front — An open space across the front of a plot between the building line and front boundary of the plot.
2.59 Open Space, Rear — An open space across the rear of a plot between the rear of the building and the rear boundary of the plot.
2.60 Open Space, Side — An open space across the side of the plot between the side of the building and the side boundary of the plot.
2.61 Owner — A person, a group of persons or a body having a legal interest in land and/or building thereon. This includes free holders, leaseholders or those holding a sublease, who will have a legal right to occupation and have liabilities in respect of safety or building condition.
In case of lease or sublease holders, as far as ownership with respect to the structure is concerned, the structure of a flat or structure on a plot belongs to the allottee/lessee till the allotment/lease subsists.
Note — For the purpose of the Code, the word ‘owner’ will also cover the generally understood terms like ‘client’, ‘user’, etc.
2.62 Parapet — A low wall or railing built along the edge of a roof or floor.
2.63 Parking Space — An area enclosed or unenclosed, covered or open, sufficient in size to park vehicles, together with a drive-way connecting the parking space with a street or alley and permitting ingress and egress of the vehicles.
2.64 Partition — An interior non-load bearing barrier, one storey or part-storey in height.
2.65 Plinth — The portion of a structure between the surface of the surrounding ground and surface of the floor, immediately above the ground.
2.66 Plinth Area — The built up covered area measured at the floor level of the basement or of any storey {see accepted standard [3(1)]}.
2.67 Porch — A covered structure supported on pillars or otherwise for the purpose of pedestrian or vehicular approach to a building.
2.68 Road — See ‘Street’.
2.69 Road Line — See ‘Street Line’.
2.70 Room Height — The vertical distance measured from the finished floor surface to the finished ceiling surface. Where a finished ceiling is not provided, the underside of the joists or beams or tie beams shall determine the upper point of measurement.
2.71 Row Housing/Row Type Building — A row of buildings, with only front, rear and interior open spaces, where applicable.
2.72 Semi-Detached Building — A building detached on three sides.
2.73 Service Road/Lane — A road/lane provided adjacent to a plot(s) for access or service purposes as the case may be.
2.74 Set-Back Line — A line usually parallel to the plot boundaries and laid down in each case by the Authority, beyond which nothing may be constructed towards the plot boundaries.
2.75 Site (Plot) — A parcel (piece) of land enclosed by definite boundaries.
2.76 Site, Corner — A site at the junctions of and fronting on two or more intersecting streets.
2.77 Site, Depth of — The mean horizontal distance between the front and rear site boundaries.
2.78 Site, Double Frontage — A site, having a frontage on two streets, other than a corner plot.
2.79 Site, Interior or Tandem — A site access to which is by a passage from a street whether such passage forms part of the site or not.
2.80 Staircover (or Mumty) — A structure with a roof over a staircase and its landing built to enclose only the stairs for the purpose of providing protection from weather and not used for human habitation.
2.81 Storey — The portion of a building included between the surface of any floor and the surface of the floor next above it, or if there be no floor above it, then the space between any floor and the ceiling next above it.
2.82 Storey, Topmost — The uppermost storey in a
building whether constructed wholly or partly on the roof.
2.83 Street — Any means of access, namely, highway, street, lane, pathway, alley, stairway, passageway, carriageway, footway, square, place or bridge, whether a thoroughfare or not, over which the public have a right of passage or access or have passed and had access uninterruptedly for a specified period, whether existing or proposed in any scheme, and includes all bunds, channels, ditches, storm-water drains, culverts, footpaths, sidewalks, traffic islands, roadside trees and hedges, retaining walls, fences, barriers and railings within the street lines.
2.84 Street Level or Grade — The officially established elevation or grade of the central line of the street upon which a plot fronts and if there is no officially established grade, the existing grade of the street at its mid-point.
2.85 Street Line — The line defining the side limits of a street.
2.86 To Erect — To erect a building means,
a) to erect a new building on any site whether previously built upon or not; and
b) to re-erect any building of which portions above the plinth level have been pull down, burnt or destroyed.
2.87 Tower-Like Structures — Structures shall be deemed to be tower-like structures when the height of the tower-like portion is at least twice the height of the broader base at ground level.
2.88 Verandah — A covered area with at least one side open to the outside with the exception of 1 m high parapet on the upper floors to be provided on the open side.
2.89 Volume to Plot Area Ratio (VPR) — The ratio of volume of building measured in cubic metre to the area of the plot measured in square metre, and expressed in metre.
2.90 Water Closet— A water flushed plumbing fixture designed to receive human excrement directly from the user of the fixture. The term is used sometimes to designate the room or compartment in which the fixture is placed.
2.91 Window — An opening to the outside other than a door, which provides all or part of the required natural light or ventilation or both to an interior space.
4.1 Every building/plot shall abut on a public/private means of access like streets/roads duly formed.
4.2 Every person who erects a building shall not at any time erect or cause or permit to erect any building which in any way encroaches upon or diminishes the area set apart as means of access required in the Code. No buildings shall be erected so as to deprive any other building of the means of access.
The residential plots shall abut on a public means of access like street/road. Plots which do not abut on a street/road shall abut/front on a means of access, the width and other requirements of which shall be as given in Table 1.
| Sl No. | Width of Means of Access | Length of Means of AccessMax |
| m | m | |
| (1) | (2) | (3) |
| i) | 6.0 | 75 |
| ii) | 7.5 | 150 |
| iii) | 9.0 | 250 |
| iv) | 12.0 | 400 |
| v) | 18.0 | 1 000 |
| vi) | 24.0 | above 1 000 |
| NOTE — If the development is only on one side of the means of access, the prescribed widths may be reduced by 1m in each case. | ||
In no case, development on plots shall be permitted unless it is accessible by a public street of width not less than 6 m.
For all assembly buildings like, theatres, cinema houses, assembly halls, stadia; educational buildings; markets, hospitals; industrial buildings and other buildings which attract large crowd, the means of access shall not be less than the following:
| Sl No. | Width of Means of Access m | Length of Means of Access m |
|---|---|---|
| i) | 12.0 | 200 |
| ii) | 15.0 | 400 |
| iii) | 18.0 | 600 |
| iv) | 24.0 | above 600 |
Further, in no case shall the means of access be lesser in width than the internal accessways in layouts and subdivision.
4.3.2.1.1 Footpath should be normally designed for a pedestrian Level of Service (LOS) B, thereby providing wide pedestrian facilities for safe, pleasant and comfortable walking. Under resource constraint, LOS C may be adopted for deciding the width of footpath mentioned in Table 2. The width of footpaths depends upon the expected pedestrian traffic and may be fixed with the help of the following norms subject to not being less than 1.8 m.
| Sl No. | Width of Foothpath | Design Flow in Number of Persons Per Hour | |||
| In Both Directions | All in One Direction | ||||
| m | LOS B(3) | LOS C(4) | LOS B(5) | LOS C(6) | |
| (1) | (2) | ||||
| i) | 1.8 | 1 350 | 1 890 | 2 025 | 2 835 |
| ii) | 2.0 | 1 800 | 2 520 | 2 700 | 3 780 |
| iii) | 2.5 | 2 250 | 3 150 | 3 375 | 4 725 |
| iv) | 3.0 | 2 700 | 3 780 | 4 050 | 5 670 |
| v) | 3.5 | 3 150 | 4 410 | 4 725 | 6 615 |
| vi) | 4.0 | 3 600 | 5 040 | 5 400 | 7 560 |
The land use adjacent to roads significantly influences generation of pedestrian traffic. Recommended width of footpath along various land uses are given in Table 3.
| Sl No. | Description | Width |
| m | ||
| (1) | (2) | (3) |
| i) | Minimum free walkway width and residential/mixed use areas | 1.8 |
| ii) | Commercial/Mixed use areas | 2.5 |
| iii) | Shopping frontages | 3.5 to 4.5 |
| iv) | Bus stops | 3 |
No premises other than highway amenities like petrol pumps, motels, etc, shall have an access direct from highways and such other roads not less than 52 m in width, which the Authority with the approval of the highway authority shall specify from time to time. For all other buildings, the access to the plot from the highway shall be only through a service road/lane as per the stipulation of the highway authority. The Authority shall maintain a register of such roads which shall be open to public inspection at all times during office hours. The portion of such roads on which direct access may be permitted shall be as identified in the Development Plan. However, in the case of existing development on highways/other roads referred to above, the operation of this clause shall be exempted. These provisions shall, however, be subject to the provisions of the relevant State Highway Act, and The National Highway Act, 1956.
4.6 For high rise buildings and special buildings (see Part 4 ‘Fire and Life Safety’ of the Code), the following additional provisions of means of access shall be ensured:
a) The width of the main street on which the building abuts shall not be less than 12 m and one end of this street shall join another street not less than 12 m in width.
b) The road shall not terminate in a dead end; except in the case of residential building, up to a height of 30 m.
c) The approach to the building and open spaces on all its sides shall be not less than 6 m in width, and a turning radius of minimum 9 m shall be provided for fire tender movement of fire tenders weighing up to 45 t. The same shall be hard surface capable of taking the mass of fire tender, weighing up to 45 t minimum. For heavier fire tenders, the minimum width, turning radius and the hard surface capable of taking the fire tender loads shall be as per the requirement laid down by the Fire Department. The layout for the open space for fire tender movement shall be done in consultation with the Chief Fire Officer of the city, which shall be kept free of obstructions and shall be motorable. The compulsory open spaces around the building shall not be used for parking.
d) The main entrance to the plot shall be of adequate width to allow easy access to the fire engine and in no case shall it measure less than 6 m. The entrance gate shall fold back against the compound wall of the premises, thus leaving the exterior accessway within the plot free for movement of fire tender. If the main entrance at the boundary wall is built over, the minimum clearance shall be 4.5 m.
4.6.1.1 Podium is a horizontal projection (platform) extending beyond the building footprint on one or more sides, and may consist of one or more levels (see Fig. 8A).
Podium may be used for the following purposes:
a) Parking of vehicles — When used for parking, one WC, two urinals and two washbasins for every 500 cars or part thereof, shall be provided on each podium floor. At least one accessible toilet complying with the requirements given in B-9 shall be provided preferably near the accessible parking.
For intersection junctions of roads meeting at right angles as well as other than right angles, the rounding off or cut off or splay or similar treatment shall be done, to the approval of the Authority, depending upon the width of roads, the traffic generated, the sighting angle, etc, to provide clear sight distance.
4.9 The building line shall be set back at least 3m from internal means of access in a layout of buildings in a plot subject to provisions of 8.2.1.
The land use classification may be as indicated below:
| Sl No. | Level 1 | Level 2 | ||||||
| N¹⁾ | A-N²⁾ | Use Category | Colour Code3),4) | Colour Code Description | N | A-N | Use Zone | |
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
| i) | 1 | R | Residential | Yellow | 11 | R-1 | Primary residential zone | |
| 12 | R-2 | Unplanned/Informal residential zone | ||||||
| ii) | 2 | C | Commercial | Red | 21 | C-1 | Retail shopping zone | |
| 22 | C-2 | General business and commercial district centres | ||||||
| 23 | C-3 | Wholesale, godowns, warehousing/regulated markets | ||||||
| 24 | C-4 | Service sector | ||||||
| 25 | C-5 | Regulated/Informal/Weekly markets | ||||||
| iii) | 3 | I | Industry | Purple | 31 | I-1 | Service and light industry | |
| 32 | I-2 | Extensive and heavy industry | ||||||
| 33 | I-3 | Special industrial zone - Hazardous, noxious and chemical | ||||||
| iv) | 4 | PS | Public and semi-public | Dark blue | 41 | PS-1 | Govt/Semi Govt/Public offices | |
| 42 | PS-2 | Govt land (use undetermined) | ||||||
| 43 | PS-3 | Police headquarter/Station, police line | ||||||
| 44 | PS-4 | Educational and research | ||||||
| 45 | PS-5 | Medical and health | ||||||
| 46 | PS-6 | Social, cultural and religious (including cremation and burial grounds) | ||||||
| 47 | PS-7 | Utilities and services | ||||||
| v) | 5 | M | Mixed use | Light yellow background with vertical hatching in black | 51 | M-1 | Mixed industrial use zone | |
| 52 | M-2 | Mixed residential zone | ||||||
| 53 | M-3 | Mixed commercial zone | ||||||
| vi) | 6 | P | Recreational | Light green | 61 | P-1 | Playgrounds/Stadium/Sports complex | |
| 62 | P-2 | Parks and gardens – Public open spaces | ||||||
| 63 | P-3 | Multi-open space (Maidan) | ||||||
²⁾ Alpha-numeric code.
¹⁾ Numeric code.
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) |
| vii) | 7 | T | Transportation and communication | Brown/Grey⁵⁾ | 71 | T-1 | Roads/Bus rapid transit system (BRTS) | |
| 72 | T-2 | Railways/Mass rapid transit system (MRTS) | ||||||
| 73 | T-3 | Airport | ||||||
| 74 | T-4 | Seaports and dockyards | ||||||
| 75 | T-5 | Bus depots/Truck terminals and freight complexes | ||||||
| 76 | T-6 | Transmission and communication | ||||||
| viii) | 8 | A | Primary activity | Dark green | 81 | PA-1 | Agriculture | |
| 82 | PA-2 | Forest and horticulture | ||||||
| 83 | PA-3 | Poultry and dairy farming | ||||||
| 84 | PA-4 | Rural settlements | ||||||
| 85 | PA-5 | Brick kiln and extractive areas | ||||||
| 86 | PA-6 | Others (Fishing, pottery, etc) | ||||||
| ix) | 9 | E | Protective and undevelopable use zone | Light blue | 91 | E-1 | Water bodies | |
| 92 | E-2 | Special recreation zone/Protective areas, such as sanctuaries/reserve forests and eco-sensitive zone | ||||||
| 93 | E-3 | Undevelopable use zone | ||||||
| x) | 10 | S | Special area | Pink | 101 | S-1 | Old built-up (Core) area | |
| 102 | S-2 | Heritage and conservation areas | ||||||
| 103 | S-3 | Scenic value areas | ||||||
| 104 | S-4 | Government restricted area (such as defence) | ||||||
| 105 | S-5 | Other uses/spot zone (see Note 5) |
NOTES
1 Overall, there could be 43 use zones at the development plan level within 10 land use categories at the perspective plan level as given in the above table.
2 Areas of informal activities may be identified in the above land use categories at level 2 for 1 to 7 level 1 use zones only.
3 Mixed use zone shall be identified at the development plan level, having dominant use and mixed use.
4 Use permissions for different activities, as specified in the next section on simplified use zone regulations may be provided at the project/action plan level or with the approval of the Statutory Authority as the case may be.
5 The process of changing/relaxing/modifying land use of part or ‘spot’ of a ‘zone’ in a particular land use is termed as ‘Spot Zoning’. Spot zoning may be done for comparatively smaller area in a particular land use zone in such a way that it does not affect the overall development plan.
6 Use zone regulations for the use permissibility (from the suggestive list) could be decided by the town planner depending upon the requirement/feasibility.
7 Appropriate code in terms of both numerical and alphabetic (letter) are provided to facilitate the reference and to have a simplified procedure to follow.
³⁾ This colour code is for Level 1 land uses.
⁴⁾ For subsequent levels of land uses different shades of Level 1 land use colour may be used along with relevant alpha-numeric code for clarity.
⁵⁾ For transportation and communication facilities, brown colour, and for roads, grey colour may be used. If so decided by the planning agency, different shades of grey may be used for both roads and facilities.
3.2 The various building uses and occupancies (see 7) permitted on the various zones shall be as given in the Master Plan of the town/city concerned.
Where the use of buildings or premises is not specifically designated on the Development/Master Plan or in the absence of Development Plan, shall be in conformity with the zone in which they fall.
Where the use of a site is specifically designated on the Development/Master Plan, it shall be used only for the purpose so designated.
No plot shall be put to any use, occupancy or premises other than the uses identified in 3.1, except with the prior approval of the Authority.
Buildings shall be so planned, designed and constructed as to ensure fire safety and this shall be done as per Part 4 ‘Fire and Life Safety’ of the Code.
3.7.1 Transferable development rights (TDR) is a compensation, in the form of floor area ratio (FAR) or development right, which shall entitle the owner for construction of built-up area, as per applicable regulations, on designated sites. The FAR credit shall be issued, in a certificate called as development right certificate (DRC). The DRC is transferrable in full or part thereof.
The development right certificate (DRC) shall be issued by the local body or the competent authority as per regulations and shall contain the following information:
a) Built-up area or FAR credit to which the owner is entitled;
b) Place and usage zone from which the DRC is generated (originating plot);
c) Place where the FAR credit shall be used (receiving plot); and
d) Details of development rights transferred and remaining.
TDR may be granted for,
a) Lands earmarked for various public purposes including road widening, which are subjected to acquisition, and are proposed in the plan or regulations prepared under the applicable town planning/municipal or any other legislation;
b) Development or construction of the amenity on the reserved land;
c) Heritage structure or precinct under the provision of development control regulations or any other applicable regulations;
d) In-lieu of constructing housing for slum dwellers, slum redevelopment, disused mill sites, etc; and
e) Purposes as may be notified by the Government as per notification.
Accommodation reservation (AR) is a planning tool for development of public amenities reserved in a redevelopment plan wherein local authority is not required to acquire the land by incurring expenditure on payment of compensation. In case of AR, the owner of land earmarked as public amenity, in the redevelopment plan, shall be permitted to develop his land, using full permissible FAR on the plot, subject to handing over the built-up area for the proposed use to the local body/Authority, free of all encumbrances, in lieu of full permissible FAR granted to him. The area utilized for the amenity shall not form part of FAR calculation.
In the case of sub-division of land in industrial zones of area 0.8 hectare or more, 5 percent of the total area shall be reserved as amenity open space which shall also serve as a general parking space; when such amenity open space exceeds 1 500 m² , the excess area could be utilized for the construction of buildings for banks, canteens, welfare centers and such other common purposes considered necessary for the industrial user, as approved by the Authority.
5.4.1 In all industrial plots measuring 1000m² or more in area, 10 percent of the total area shall be provided
as an amenity open space to a maximum of 2 500 m² . Such an amenity open space shall have a means of access and shall be so located that it could be conveniently utilized as such by the persons working in the industry.
In any layout or sub-division of land measuring 0.3 ha or more in residential and commercial zones, the community open spaces shall be reserved for recreational purposes which shall as far as possible


MINIMUM CLEAR RAMP WIDTH, m
| ONE WAY | TWO WAY | |
| LMV | 3.0 | 6.0 |
| LCV | 4.5 | 9.0 |
| HMV | 6.0 | 12.0 |
| FIRE TENDER | 7.5 | |
8B RAMPS FOR PODIUM
FIG. 8 BUILDINGS ON PODIUM AND THEIR RAMPS


FIRE TENDER ACCESS (FTA)
9A EMERGENCY VEHICLE ACCESS REQUIREMENT IN CASE PODIUM IS NOT ACCESSIBLE BY FIRE TENDER

9B EXTENT OF PODIUM PROJECTION ALLOWED BEYOND BUILDING ON SIDE HAVING FIRE TNEDER ACCESS (IF PODIUM IS NOT ACCESSIBLE BY FIRE TENDER)
FIG. 9 — (Continued)


be provided in one place or planned out for the use of the community in clusters or pockets.
5.1.1 The community open spaces shall be provided catering to the needs of area of layout, population for which the layout is planned and the category of dwelling units. The following minimum provision shall be made:
a) 15 percent of the area of the layout, or
b) 0.3 to 0.4 ha/1 000 persons; for low income housing, the open spaces shall be 0.3 ha/1 000 persons.
5.2 No recreational space shall generally be less than 450m².
5.2.1 The minimum average dimension of such recreational space shall be not less than 7.5m; if the average width of such recreational space is less
than 24 m, the length thereof shall not exceed 2.5 times the average width. However, depending on the configuration of the site, commonly open spaces of different shapes may be permitted by the Authority, as long as the open spaces provided serve the needs of the immediate community contiguous to the open spaces.
5.2.2 In such recreational spaces, a single storeyed structure as pavilion or gymnasia up to 25m² in area may be permitted; such area may be excluded from FAR calculations.
5.3 Each recreational area and the structure on it shall have an independent means of access. Independent means of access may not be insisted upon if recreational space is approachable directly from every building in the layout. Further, the building line shall be at least 3 m away from the boundary of recreational open space.
Buildings are classified based on occupancy and types of construction.
7.1 For the purpose of the Code, the following shall be the occupancy classification and types of construction; for more detailed information, reference may be made to Part 4'Fire and Life Safety' of the Code.
a) Residential;
b) Educational;
c) Institutional;
d) Assembly;
e) Business;
f) Mercantile (will include both retail and wholesale stores);
g) Industrial (will include low, moderate and high fire hazards);
h) Storage; and
j) Hazardous.
a) Type 1,
b) Type 2,
c) Type 3, and
d) Type 4.
6.1 No building shall be constructed on any site, on any part of which there is deposited refuse, excreta or other offensive matter objectionable to the Authority, until such refuse has been removed therefrom and the site has been prepared or left in a manner suitable for building purposes to the satisfaction to the Authority.
Wherever the dampness of a site or the nature of the soil renders such precautions necessary, the ground surface of the site between the walls of any building erected thereon shall be rendered damp-proof to the satisfaction of the Authority.
Any land passage or other area within the curtilage of a building shall be effectively drained by surface water drains or other means.
6.3.1 The written approval of the Authority shall be obtained for connecting any subsoil or surface water drain to a sewer.
An overhead line shall not cross an existing building as far as possible and no building shall be constructed under an existing overhead line. No accessible point from any Verandah, balcony, or the like shall be allowed to be erected or re-erected or any additions or alterations made to a building not having the following minimum clearances from an overhead electric supply line, in accordance with the current Central Electricity Authority (Measures Relating to Safety and Electric Supply) Regulations, 2010 as amended from time to time:
a) Clearance of buildings from lines of voltages and service lines not exceeding 650V
An overhead line shall not cross over an existing building as far as possible and no building shall be constructed under an existing overhead line.
Where an overhead line of voltage not exceeding 650 V passes above or adjacent to or terminates on any building, the following minimum clearances from any accessible point, on the basis of maximum sag, shall be observed:
i) For any flat roof, open balcony, Verandah roof and lean-to-roof:
a) where the line passes above the building, a vertical clearance of 2.5 m from the highest point, and
b) when the line passes adjacent to the building, a horizontal clearance of 1.2 m from the nearest point, and
ii) For pitched roof:
a) where the line passes above the building, a vertical clearance of 2.5m immediately under the line, and
b) when the line passes adjacent to the building, a horizontal clearance of 1.2m.
The horizontal clearance shall be measured when the line is at a maximum deflection from the vertical due to wind pressure.
Any conductor so situated as to have a clearance less than that specified above shall be adequately insulated and shall be attached at suitable intervals to a bare earthed bearer wire having a breaking strength of not less than 350 kg.
b) Clearances from buildings of lines of voltages exceeding 650 V
no building shall be constructed under an existing overhead line.
i) For lines of : 3.7 m upto and voltages including 33 kV; exceeding and 650 V
ii) For lines of : 3.7 m plus 0.30 m voltages for every additional 33 kV or part thereof. exceeding 33 kV
The horizontal clearance between the nearest conductor and any part of such building shall, on the basis of maximum deflection due to wind pressure, be not less than:
i) For lines of : 1.2 m voltages exceeding 650 V and up to and including 11 kV
ii) For lines of : 2.0 m voltages exceeding 11 kV and up to and including 33 kV
iii) For lines of : 2.0 m plus voltages exceeding 0.3 m for every additional 33 kV or part thereof
| Sl No. | d.c.Voltage | Vertical Clearance | Horizontal Clearance |
|---|---|---|---|
| kV | m | m | |
| (1) | (2) | (3) | (4) |
| i) | 100 | 4.6 | 2.9 |
| ii) | 200 | 5.8 | 4.1 |
| iii) | 300 | 7.0 | 5.3 |
| iv) | 400 | 7.0 | 6.2 |
| v) | 500 | 9.1 | 7.4 |
| vi) | 600 | 10.3 | 8.6 |
| vii) | 800 | 12.4 | 10.7 |
Distance of site from the normal edge of water course/area may be specified by the Authority, keeping in view the normal maximum flood/tide level.
Each plot shall have a minimum size/frontage corresponding to the type of development as given below:
| SlNo.(1) | Type of Development(2) | Plot Size m² (3) | Frontagem(4) |
| i) | Detached building | Above 250 | above 12 |
| ii) | Semi-detachedbuilding | 125-250 | 8 to 12 |
| iii) | Row type building | 50-125 | 4.5 to 8 |
| NOTE — For low income housing,see 14. | |||
6.6.1.1 The minimum size of the site for group housing development shall be as given in the Master Plan and local development control rules.
The size of the plot shall not be less than 300m² and its width shall not be less than 15m.
The minimum size of plots for buildings for other uses not covered under 5.5 shall be as decided by the Authority. Various requirements with respect to cinema buildings shall be in accordance with the good practice [3(2)].
In addition to community open spaces, the layouts shall provide for the amenities as given in 5.5.1 to 5.5.13. These provisions may be modified based on specific requirements, as decided by the Authority.
| Land Area Required, Min | |
| a) Pre-Primary to secondary education | |
| 1) Pre-primary, nursery school — 1 for every 2 500 population | |
| i) Area per school | 0.08 ha |
| ii) Location of pre-primary/nursery school | to be located near a park |
| 2) Primary school (class 1 to 5) — 1 for every 5 000 population | |
| i) Strength of the school — 500 students | |
| ii) Area per school: | 0.40 ha |
| a) School building area | 0.20 ha |
| b) Play field area (with a minimum of 18 m × 36 m to be ensured for effective play) | 0.20 ha (which is inclusive of the limited parking requirement for functional uses) |
| 3) Senior secondary school (class 6 to 12) — 1 for every 7 500 population | |
| i) Strength of the school — 1 000 students | |
| ii) Area per school: | 1.80 ha |
| a) School building area | 0.60 ha |
| b) Play field area (with a minimum of 68 m × 126 m to be ensured for effective play) | 1.00 ha |
| c) Parking area | 0.20 ha |
| 4) Integrated school without hostel facility (class 1 to 12) — 1 for every 90 000 to 100 000 population | |
| i) Strength of the school — 1 500 students | |
| ii) Area per school: | 3.50 ha |
| a) School building area | 0.70 ha |
| b) Play field area | 2.50 ha |
| c) Parking | 0.30 ha |
| iii) Location | To be located near a sport facility |
| 5) Integrated school with hostel facilities (class 1 to 12) — 1 for every 90 000 to 100 000 population | |
| i) Strength of school — 1 500 students | |
| ii) Area per school: | 3.90 ha |
| a) School building area | 0.70 ha |
| b) Play field area | 2.50 ha |
| c) Residential (including hostel area) | 0.40 ha |
| d) Parking area | 0.30 ha |
| iii) Location | To be located near a sport facility |
| 6) School for children with disabilities (Class 1 to 12) — 1 for every 45 000 population | |
| i) Strength of the school — 400 students | |
| ii) Area per school: | 0.70 ha |
| a) School building area | 0.20 ha |
0.30 ha
0.20 ha
To be located near a park or sport facility
NOTE — The schools should be inclusive providing education to all children including those with disabilities. However it may be required to have exclusive schools in case of certain disabilities, such as, speech, hearing, sight and multiple disabilities.
0.20 ha
To be located near a park and
The schools should preferably face service roads and roads with less traffic intensity.
non-noise polluting zone
| 1) College — 1 for every 125 000 population | |
| i) Strength of the college — 1 000 to 1 500 students | |
| ii) Area per college: | 5.00 ha |
| a) College building area | 1.80 ha |
| b) Play field area | 2.50 ha |
| c) Residential (including hostel area) | 0.40 ha |
| d) Parking area | 0.30 ha |
| 2) University campus | |
| Area: | 10.00 ha to 60.00 ha |
| i) Residential (if included) area | 25 percent of total land area |
| ii) Sports and cultural activities | 15 percent of total land area |
| iii) Parks and landscape including green belt | 15 percent of total land area |
| 1) Technical education centre (A) — 1 for every 1 000 000 population to include 1 industrial training institute (ITI) and 1 polytechnic | |
| i) Strength of ITI — 400 students | |
| ii) Strength of polytechnic — 500 students | |
| iii) Area per technical education centre: | 4.00 ha |
| a) Area for ITI | 1.60 ha |
| b) Area for polytechnic | 2.40 ha |
Area per technical education centre: 4.00 ha i) Area for ITI 1.60 ha ii) Area for technical centre 2.10 ha iii) Area for coaching centre 0.30 ha
| 1) Engineering college — 1 for every 1 000 000 population | |
| i) Strength of the college — 1 500 students | |
| ii) Area per college | 6.00 ha |
Medical college — 1 for every 1 000 000 population Area of site including space for general hospital 15.00 ha
Nursing and paramedic institute — 1 for every 1 000 000 population Plot area per institute (subject to Nursing Council of India/Ministry of Health Norms) 0.20 ha
Veterinary institute Area As per Veterinary Council of India/Ministry of Agriculture norms (subject to availability of land)
| 5) Other professional colleges — 1 for every 1 000 000 population | |
| i) Strength of the college — 250 to 1 500 students | |
| ii) Area of site: | |
| a) for students strength up to 250 students | 2.00 ha |
| b) additional area of site for every additional 100 students or part thereof up to total strength of 1 000 students | 0.50 ha |
| c) for strength of college from 1 000 to 1 500 students | 6.00 ha |
| Land Area Required, Min | |
| a) Dispensary — 1 for every 15 000 populationArea | 0.08 ha to 0.12 ha |
| b) Nursing home, child welfare and maternity centre — 1 for every45 000 to 100 000 population1) Capacity — 25 to 30 beds2) Area 0.20 ha to 0.30 ha | |
| c) Poly-clinic with some observation beds — 1 for every 100 000 population)Area | 0.20 ha to 0.30 ha |
| d) Intermediate hospital (category B) — 1 for every 100 000 population | |
| 1) Capacity — 80 beds (initially the provision may be for 50 beds including20 maternity beds) | |
| 2) Total area:i) Area for hospitalii) Area for residential accommodation | 1.00 ha0.60 ha0.40 ha |
| e) Intermediate hospital (category A) — 1 for every 100 000 population | |
| 1) Capacity — 200 beds (initially the provision may be for 100 beds) | |
| 2) Total area:i) Area for hospitalii) Area for residential accommodation | 3.70 ha2.70 ha1.00 ha |
| f) General hospital — 1 for every 250 000 population | |
| 1) Capacity — 500 beds (initially the provision may be for 300 beds) | |
| 2) Total area:i) Area for hospitalii) Area for residential accommodation | 6.00 ha4.00 ha2.00 ha |
| g) Multi-speciality hospital — 1 for 100 000 population | |
| 1) Capacity — 200 beds (initially the provision may be for 100 beds) | |
| 2) Total area:i) Area for hospitalii) Area for residential accommodation | 9.00 ha6.00 ha3.00 ha |
| h) Speciality hospital — 1 for every 100 000 population | |
| 1) Capacity — 200 beds (initially the provision may be for 100 beds) | |
| 2) Total area:i) Area for hospitalii) Area for residential accommodation | 3.70 ha2.70 ha1.00 ha |
| j) Family welfare centre — 1 for every 50 000 populationArea | 500 m² to 800 m² |
| k) Diagnostic centre — 1 for every 50 000 populationArea | 500 m² to 800 m² |
| PART 3 DEVELOPMENT CONTROL RULES AND GENERAL BUILDING REQUIREMENTS | PART 3 DEVELOPMENT CONTROL RULES AND GENERAL BUILDING REQUIREMENTS |
| m) Veterinary hospital for pets and animals — 1 for every 500 000 population Area | 0.20 ha |
| n) Dispensary for pet animals and birds — 1 for every 100 000 population Area | 300 m² |
| p) Rehabilitation centres Area |
| Land Area Required, Min | |
|---|---|
| a) Community room — 1 for every 5 000 populationArea | 750 m² |
| b) Community hall, Mangal Karyalaya/Kalyana Mandapam/Barat Ghar/library — 1 for every 15 000 population)Area | 2 000 m² |
| c) Recreational club — 1 for every 100 000 populationArea | 10 000 m² |
| d) Music, dance and drama centre — 1 for every 100 000 populationArea | 1 000 m² |
| e) Meditation and spiritual centre — 1 for every 100 000 populationArea | 5 000 m² |
| f) Socio-cultural centre/Exhibition cum fair ground — 1 for every 1 000 000 populationArea | 15.00 ha |
| g) Anganwadi-housing area/cluster — 1 for every 5 000 populationArea | 200 to 300 m² |
| h) Old age home — 1 for every 500 000 populationArea | 1000 m² Max,subject to availability of land |
| j) Religious facilities1) At neighbourhood/housing cluster level — 1 for every 5 000 populationArea | 400 m² |
| 2) At sub-city level in urban extension — 1 for every 1 000 000 populationArea | 4.00 ha |
| k) Science centre — 1 for every 1 000 000 populationArea | As per requirement |
| m) International convention centre — 1 at city levelArea | As per requirement |
| n) Other facilities | |
| 1) Orphanage/Children’s centre (one each) — 1 for every 1 000 000 populationArea | 1 000 m² Max,subject to availability of land |
| 2) Centre for support services for persons with disabilities — 1 for every 1 000 000 populationArea | 1 000 m² Max,subject to availability of land |
| 3) Working women/men hostel — 1 for every 1 000 000 populationArea | 1 000 m² Max,subject to availability of land |
| 4) Adult education centre — 1 for every 1 000 000 populationArea | 1 000 m² Max,subject to availability of land |
| 5) Night shelter — 1 for every 1 000 000 populationArea | 1 000 m² Max,subject to availability of land |
| 5.5.4 Distribution Services | 5.5.4 Distribution Services |
| Land Area Required, Min | Land Area Required, Min |
| a) Petrol/diesel filling and servicing centre — May be permitted in central as well as sub-central business district, district centres, community centres (only filling station), residential and industrial use zones in urban areas, along the national highways, state highways, villages identified as growth centres, freight complex, proposed major roads and police/security force services (for captive use only). |
Every room intended for human habitation shall abut on an interior or exterior open space or an open Verandah open to such interior or exterior open space.
8.1.1 The open spaces inside and around a building have essentially to cater for the lighting and ventilation requirements of the rooms abutting such open spaces, and in the case of buildings abutting on streets in the front, rear or sides, the open spaces provided shall be sufficient for the future widening of such streets.
The open spaces shall be separate or distinct for each building and where a building has two or more wings, each wing shall have separate or distinct open spaces for the purposes of lighting and ventilation of the wings.
34
However, separation between accessory and main buildings more than 7 m in height shall not be less than 1.5 m; for buildings up to 7 m in height no such separation shall be required.
8.1.3 The open space shall be the minimum distance measured between the front, rear and side of the building and the respective plot boundaries. The front, rear and side of the building shall be the point of the building nearest to the boundary.
8.3.1 Open spaces for other occupancies shall be as
given below:
a) Educational buildings — Except for nursery schools, the open spaces around the building shall be not less than 6 m.
b) Institutional buildings — The open spaces around the building shall be not less than 6 m.
c) Assembly buildings — The open space at front shall be not less than 12 m and the other open spaces around the building shall be not less than 6 m.
NOTE — However, if assembly buildings are permitted in purely residential zones, the open spaces around the building shall be not less than 12 m.
d) Business, mercantile and storage buildings — The open spaces around the building shall be not less than 4.5 m for heights up to 16 m, with an increase of the open spaces of 0.25 m for every increase of 1 m or fraction thereof in height above 16 m. Where these occur in a purely residential zone or in a residential with incidental shops line zone the open spaces may be relaxed.
e) Industrial buildings — The open spaces around the building shall be not less than 4.5 m for heights up to 16 m, with an increase of the open spaces of 0.25 m for every increase of 1 m or fraction thereof in height above 16 m.
NOTE — Special rules for narrow industrial plots in the city, namely plots less than 15 m in width, and with appropriate set-backs from certain streets and highways, shall be applicable.
f) Hazardous occupancies — The open spaces around the building shall be as specified for industrial buildings [see 8.3.1(e)].
Every open space provided either interior or exterior shall be kept free from any erection thereon and shall be open to the sky, except as given below:
a) Cornice, roof or weather shade not more than 0.75 m wide;
b) Sunshades over windows/ventilators or other openings not more than 0.75 m wide;
c) Canopy not to be used as a sit out with clearance of 1.5 m between the plot boundary and the canopy;
d) Projected balcony at higher floors of width not more than 1.2 m; and
e) Projecting rooms/balconies [see 8.4.1(d)] at alternate floors such that rooms of the lower two floors get light and air and the projection being not more than the height of the storey immediately below.
However, these projections into open spaces shall not reduce the minimum required open spaces.
The following accessory buildings may be permitted in the open spaces:
a) In an existing building, sanitary block of 2.4m in height subject to a maximum of 4m² in the rear open space at a distance of 1.5m from the rear boundary may be permitted, where facilities are not adequate.
b) Parking lock up garages not exceeding 2.4 m
in height shall be permitted in the side or rear open spaces at a distance of 7.5 m from any road line or the front boundary of the plot; and
c) Suction tank and pump room each up to 2.5 m² in area.
8.4.2.1 In existing built-up or congested areas, no projection of any sort whatsoever, except sunshades (see 8.4.2.3) extending more than 230 mm below a height of 4.3 m, shall project over the road or over any drain or over any portion outside the boundaries of the site, provided the projection arising out of the vertical part of the rain-water spouts projecting at the road level or the water pipe may be permitted in accordance with the drainage plan.
Porticos in bazaar areas of existing developed areas may be permitted to project on road land subject to the following limitations:
a) Porticos may be allowed on such roads leaving a minimum clear space of 18m between kerbs;
b) The porticos shall not be less than 3 m wide;
c) Nothing shall be allowed to be constructed on the portico which shall be used as an open terrace;
d) Nothing shall be allowed to project beyond the line of arcades; and
e) The space under the portico shall be paved and channeled according to the directions of the Authority.
Projections of sunshades over windows or ventilators in existing built-up or congested areas when permitted by the Authority shall fulfill the following conditions:
a) No sunshade shall be permitted over the road or over any drain or over any portion outside the boundaries of the site below a height of 2.8 m from the road level;
b) Sunshades provided above a height of 2.8 m from the ground level shall be permitted to project up to a maximum width of 60 cm, if the road over which they project exceeds 9 m in width; and
c) No sunshade shall be permitted on roads less than 9 m in width or on roads having no footpaths.
No construction work on a building shall be allowed if
such work operates to reduce an open air space of any other adjoining building, belonging to the same owner to an extent less than what is prescribed at the time of the proposed work or to reduce further such open space if it is already less than that prescribed.
Additions or extensions to a building shall be allowed, provided the open spaces for the additions/extensions satisfy 8.2 after such additions/extensions are made.
8.6 In case of buildings on podium, the requirements for spaces shall also comply with 4.6.1.3 [see also Fig. 8(a)].
The limitation of area and height of buildings of different occupancy classes and types of construction shall be achieved by specifying it in terms of FAR, which shall take into account the various aspects that govern in specifying FAR as given below:
a) Occupancy class;
b) Types of construction;
c) Width of street fronting the building and the traffic load;
d) Locality where the building is proposed and the density;
e) Parking facilities;
f) Local fire fighting facilities; and
g) Water supply, drainage and sanitation facilities.
9.2 The comparative FARs for different occupancies and types of construction are as given in Table 5 and the Authority shall select a basic FAR for one occupancy and a type of construction and arrive at the FAR values for other combinations taking into account the other local factors (see 9.1).
The minimum fire separation on all sides of buildings of unlimited areas (see Table 5) and of Type 1 construction shall be 9m.
The area limits shall apply to all buildings fronting on a street or public space not less than 9 m in width accessible to a public street.
The height and number of storeys shall be related to FAR and the provisions of 8.
9.4.1 Where a building height is not covered by Table 5,
the maximum height shall be limited according to the width of the street as follows:
a) The maximum height of building shall not exceed 1.5 times the width of road abutting plus the front open space, subject to the requirement of front open space of a maximum of 16 m;
b) If a building abuts on two or more streets of different widths, the building shall be deemed to face upon the street that has the greater width and the height of the building shall be regulated by the width of that street and may be continued to this height to a depth of 24 m along the narrower street subject to conformity of 8; and
c) For buildings in vicinity of aerodromes, provisions of 9.5 shall apply.
The following appurtenant structures shall not be included in the height of the building unless the aggregate area of such structures, including pent-houses, exceeds one-third of the area of the roof of building upon which they are erected:
a) Roof tanks and their supports (with support height not exceeding 1 m);
b) Ventilating, air conditioning, lift rooms and similar service equipment;
c) Stair cover (Mumty) not exceeding 3 m in height; and
d) Chimneys, parapet walls and architectural features not exceeding 1.2m in height.
9.4.2.2 The building height for different occupancy types shall not exceed the maximum height prescribed in Part 4 ‘Fire and Life Safety’ of the Code.
9.5.1 For buildings in the vicinity of aerodromes, the maximum height of such buildings shall be decided in consultation with the Airports Authority of India who shall be responsible for issuing the no objection certificate. This shall be in accordance with the concerned notification of the Ministry of Civil Aviation, Govt of India.
9.5.1.1 For the purpose of 9.5.1, new buildings and structures coming up in the vicinity of an aerodrome shall be subjected to height restrictions in accordance with the subject notification.
No building or structure higher than the height specified in the subject notification shall be constructed or erected and no tree which is likely to grow or ordinarily grows
| Sl No. | Occupancy Classification | Type of Construction | |||
| Type 1(3) | Type 2(4) | Type 3(5) | Type 4(6) | ||
| i) | Residential | UL | 2.0 | 1.4 | 1.0 |
| ii) | Educational | UL | 2.0 | 1.4 | 1.0 |
| iii) | Institutional | UL | 1.5 | 1.0 | 0.8 |
| iv) | Assembly | UL | 1.0 | 0.7 | 0.5 |
| v) | Business | UL | 2.9 | 2.3 | 1.6 |
| vi) | Mercantile | 8.0 | 1.8 | 1.4 | 1.0 |
| vii) | Industrial | 7.5 | 1.9 | 1.6 | 1.3 |
| viii) | Storage (see Note 4) | 6.0 | 1.5 | 1.3 | 1.0 |
| ix) | Hazardous (see Note 4) | 2.8 | 1.1 | 0.9 | NP |
| UL – Unlimited.NP – Not Permitted NOTES1 This table has been prepared, taking into account the combustible content in the different occupancies as well as the fire resistance offered by the type of construction (see Part 4 ‘Fire and Life Safety’ of the Code).2 This table shall be modified by the Authority, taking into account the other aspects as given below (see 9.1):a) Density in terms of dwelling units/hectare;b) Traffic considerations;c) Parking spaces;d) Local fire fighting facilities; ande) Water supply, drainage and sanitation requirements.3 The FAR specified may be increased by 20 percent for the following:a) A basement or cellar and space under a building constructed on stilts and used as a parking space, and air conditioning plant room used as accessory to the principal use;b) Electric cabin or substation watchman's booth of maximum size of 1.6 m² with minimum width or diameter of 1.2 m, pump house, garbage shaft, space required for location of fire hydrants, electric fittings and water tank;c) Projections and accessory buildings as specifically exempted (see 8.4.1); andd) Staircase room and lift rooms above the topmost storey, architectural features; and chimneys and elevated tanks of dimensions as permissible under the Code; the area of the lift shaft shall be taken only on one floor.4 In so far as single storey storage and hazardous occupancies are concerned, they would be further governed by volume to plot area ratio (VPR), to be decided by the Authority. | |||||
9.6.1 Group housing development may be in low rise house clusters or high rise multi-storeyed apartments for high density development.
9.6.2 No limit to floors and height shall be applicable, but the coverage and floor area ratio for various
densities may be as given in Table 6 unless provided otherwise in the Master Plan and local development control rules.
9.6.3 The minimum size of the site for group housing multi-storeyed apartment shall be 3 000 m² .
9.6.3.1 The number of dwelling units are calculated on the basis of the density pattern given in the Development Plan taking into consideration a population of 4.5 persons per dwelling unit.
9.6.3.2 The basement may vary between 33.33 and 50 percent of the plot area and is to be used for parking, servicing and for essential household storage without counting in FAR.
9.6.3.3 Parking space shall be provided in accordance with 10. Designated accessible parking spaces shall be provided in accordance with B-3.
9.6.4 With a view to providing adequate parking for occupancies and the vehicular load, appropriate off-street parking provisions have to be made in the
| Sl No. | Net Residential Density Dwelling Units/Hectare | Maximum Coverage Percent | Floor Area Ratio |
|---|---|---|---|
| (1) | (2) | (3) | (4) |
| i) | 25 | 25 | 0.50 |
| ii) | 50 | 30 | 0.75 |
| iii) | 75 | 33 | 0.90 |
| iv) | 100 | 35 | 1.00 |
| v) | 125 | 35 | 1.25 |
| vi) | 150 | 35 | 1.50 |
| vii) | 175 | 35 | 1.75 |
| viii) | 200 | 35 | 2.00 |
| ix) | 225 | 35 | 2.25 |
| x) | 250 | 35 | 2.50 |
| xi) | 275 | 35 | 2.75 |
| xii) | 300 | 35 | 3.00 |
| xiii) | 325 | 35 | 3.25 |
| xiv) | 350 | 35 | 3.50 |
| xv) | 375 | 35 | 3.75 |
10.1 The off-street parking (on-site parking) spaces in a plot to be provided shall be in accordance with Annex A. The spaces given in Annex A shall be considered by the Authority in conjunction with the Development Rules, in force, if any.
10.2 The spaces to be left out for off-street parking as given in 10.3 to 10.6 shall be in addition to the open spaces left out for lighting and ventilation purposes as given in 20.
10.2.1 Further 50 percent of the open spaces required around buildings under 8 may be allowed to be utilized for parking or loading or unloading spaces, provided a minimum distance of 3.6 m around the building is kept free from any parking, loading or unloading spaces subject to the provisions of Part 4 ‘Fire and Life Safety’ of the Code.
10.3 Each off-street parking space provided for vehicles shall be as follows:
a) For car, the minimum parking space to be 3m× 6m when individual parking space
is required and 2.75m× 5m when common parking space is required.
b) Space for scooter/two wheeler and bicycle to be not less than 1.25 m² and 1.00 m² , respectively.
c) Area for each equivalent car space inclusive of circulation area is 23 m² for open parking, 28 m² for ground floor covered parking and 32 m² for basement.
10.4 For buildings of different occupancies, off-street parking space for vehicles shall be provided as stipulated below:
a) Motor vehicles — Space shall be provided as specified in Annex A for parking motor vehicles (cars).
b) Other types of vehicles — For non-residential building, in addition to the parking areas provided in (a) above, 25 to 50 percent additional parking space shall be provided for parking other types of vehicles and the additional spaces required for other vehicles shall be as decided by the Authority, keeping in view the nature of traffic generated in the city.
For residential occupancy, space for motorcycle/scooter/cycle/two-wheeler shall be provided at the rate of one for each tenement.
10.5 Off-street parking space shall be provided with adequate vehicular access to a street; and the area of drives, aisles and such other provisions required for adequate manoeuvring of vehicle shall be exclusive of the parking space stipulated in these provisions.
10.6 If the total parking space required by these provisions is provided by a group of property owners for their mutual benefits, such use of this space may be construed as meeting the off-street parking requirements under these provisions, subject to the approval of the Authority.
10.7 In buildings of mercantile (commercial), industrial and storage type, in addition to the parking spaces provided, a space at the rate of 3.5 m × 7.5 m , shall be provided for loading and unloading activities, for each 1 000 m² of floor area or fraction thereof.
10.8 Parking spaces shall be paved and clearly marked for different types of vehicles.
10.9 Apart from parking at ground level, provision of underground or multi-storeyed parking or podium parking may be permitted. The parking of vehicles at different level may also be mechanized. In the case of parking spaces provided in basement(s), at least two ramps of width and slope as per 4.6.1.3 shall be
provided, located preferably at opposite ends. In case of underground/multi-storeyed parking, special measures with regard to fire safety shall be taken (see Part 4 ‘Fire and Life Safety’ of the Code).
10.10 Designated accessible parking spaces shall be provided in accordance with B-3 for the occupancies specified in 13.
Greenbelts and landscaping including plantation of shrubs and trees help to certain extent in enhancing the environmental quality.
11.1.1 Planting of trees in streets and in open spaces should be done carefully to take advantage of both shades and sunshine without obstructing the flow of wind circulation and sight. Their advantage for abating glare and for providing cool and/or warm pockets in developed areas should also be taken.
11.2.1 Suitable provisions may be made for greeneries including plantation of shrubs and trees as a part of environmental protection in general. This aspect shall be taken care of from the initial stage of town and country planning, zoning and planning of development of particular area and group housing. Finally, this aspect shall also be taken into account in planning individual building of different occupancies.
11.2.2 The types of plants, the distance between trees/plants from the building and the distance between plants shall be carefully worked out keeping in view the structural safety and aesthetic requirements of buildings.
11.3 Trees shall be numbered area-wise, plot-wise and road-wise by the concerned authority and they shall be checked periodically.
11.4 Cutting and pruning of trees in public as well as private areas shall be suitably regulated. Trees shall be cut only after obtaining the permission of the Authority designated for this purpose.
11.5 The landscape planning and design shall be done in accordance with Part 10 ‘Landscape Development, Signs and Outdoor Display Structures, Section 1 Landscape Planning, Design and Development’ of the Code.
In view of critical shortage of water, conservation of water by rain water harvesting and by use of recycled water to the maximum extent possible is required. In this regard the provisions given in 11.6.1 to 11.6.5 may be adopted.
11.6.1 The local authority preparing a town-planning scheme or a development plan should see that the local water bodies are preserved, and if dry, are activated by directing water-courses appropriately. If required, the same should be enlarged, deepened, etc.
The requirements for various parts of buildings shall be in accordance with 12.1 to 12.9. The requirements as given in 13, for public buildings and sites as accessible and barrier free for elders and persons with disabilities, shall also be complied with.
The plinth or any part of a building or outhouse shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth shall be not less than 450 mm from the surrounding ground level.
Every interior courtyard shall be raised at least 150 mm above the determining ground level and shall be satisfactorily drained.
The height of a kitchen measured from the surface of the floor to the lowest point in the ceiling (bottom slab) shall not be less than 2.75 m, except for the portion to accommodate floor trap of the upper floor.
The area of a kitchen where separate dining area is provided, shall be not less than 5.0 m² with a minimum width of 1.8 m. Where there is a separate store, the area of the kitchen may be reduced to 4.5 m² . A kitchen, which is intended for use as a dining area also, shall have a floor area of not less than 7.5 m² with a minimum width of 2.1 m.
Every room to be used as kitchen shall have,
a) unless separately provided in a pantry, means for the washing of kitchen utensils which shall lead directly or through a sink to a grated and trapped connection to the waste pipe;
b) an impermeable floor;
c) a flue, if found necessary; and
d) a window or ventilator or opening of size not less than as specified in 20.1.1 subject to increase in area of opening in accordance with 20.1.2 (Note 3).
It shall have a minimum height of 2.2m.
The minimum size of the mezzanine floor, if it is to be used as a living room, shall not be less than 9.5 m² . The aggregate area of such mezzanine floor in a building shall in no case exceed one-third the plinth area of the building.
A mezzanine floor may be permitted over a room or a compartment, provided,
a) it conform to the standard of living rooms as regards lighting and ventilation in case the size of mezzanine floor is 9.5 m² or more (see 20.1.2);
b) it is so constructed as not to interfere under any circumstances with the ventilation of the space over and under it;
c) such mezzanine floor is not subdivided into smaller compartments;
d) such mezzanine floor or any part of it shall not be used as a kitchen; and
e) in no case shall a mezzanine floor be closed so as to make it liable to be converted into unventilated compartments.
The height of a store room shall be not less than 2.2 m.
The size of a store room, where provided in a residential building, shall be not less than 3m².
The height of a garage shall be not less than 2.4m.
The size of garages shall be as below:
a) Private garage — 3.0 m × 6.0 m, minimum; and
b) Public garage — Based on the number of vehicles parked, etc (see 10).
12.9.1 The basement shall not be used for residential purposes.
12.9.2 The construction of the basement shall be allowed by the Authority in accordance with the land use and other provisions specified under the Development Control Rules.
12.9.2.1 The following uses shall be permitted in the basements:
a) Storage of household or other goods of ordinarily non-combustible material;
b) Strong rooms, bank cellars, etc;
c) Air conditioning equipment and other machines used for services and utilities of the building; and
d) Parking spaces.
The Authority may also consider permitting mercantile occupancy as well as institutional occupancy for medical, health care services involving radiation facilities in the first basement subject to compliance of all requirements for fire safety in accordance with Part 4 'Fire and Life Safety' of the Code and necessary measures for required lighting, ventilation and water supply, drainage and sanitation.
12.9.2.2 The basements can be permitted below the ground and beyond the building lines at ground level subject to a clear minimum front margin of 4.5 m and side and rear margins of 3 m, and further subject to non-habitable uses and provision for mechanical ventilation and all safety provisions and drainage (see Fig. 11). However, it is essential that the basement top slab below the external circulation at ground level should be designed for fire fighting vehicular loads as given in 4.6.
12.9.3 The basement shall have the following requirements:
a) Every basement shall be in every part at least 2.4 m in height from the floor to the underside of the roof slab or ceiling;
b) Adequate ventilation shall be provided for the basement. The ventilation requirements shall be the same as required by the particular occupancy according to byelaws. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers, exhaust fans, air conditioning systems, etc;
c) The height of the ceiling of any basement shall be minimum 0.9 m and the maximum, 1.2 m above the average surrounding ground level. However, in case of parking, mercantile or business occupancy at ground floor, minimum height of the ceiling of the basement may
be 0.3m above the average surrounding ground level subject to mechanical ventilation being provided (see Fig. 11);
d) Adequate arrangements shall be made such that surface drainage does not enter the basement;
e) The walls and floors of the basement shall be watertight and be so designed that the effects of the surrounding soil and moisture, if any, are taken into account in design and adequate damp proofing treatment is given;
| v) | High intensity commercial areas | 4 |
4.3.2.1.2 The footpath shall be level, non-slip and continuous, and shall be provided with tactile orientation, kerb and kerb ramp. The footpath shall comply with the requirements given in B-2 other than for width which shall be as per 4.3.2.1.1.
The approach to the buildings from road/street/internal means of access shall be through paved pathway complying with requirements in B-2. The length of the pathway shall not be more than 30 m. The safety concern of cyclists and pedestrians should be addressed by encouraging the construction of segregated rights of way for bicycles and pedestrians.
4.3.2.2.1 In the case of special housing schemes for low income group and economically weaker section of society developed up to two storeyed row/cluster housing scheme, the main means of access through pedestrian pathway width shall be 3 m subject to provisions of 9.4.1(a). The pedestrian pathway shall not serve more than 8 plots on each side of the pathway; the length of the pathway shall be not more than 60 m.
4.3.3 The length of the main means of access shall be determined by the distance from the farthest plot (building) to the public street. The length of the subsidiary accessway shall be measured from the point of its origin to the next wider road on which it meets.
4.3.4 In the interest of general development of an area, the Authority may require the means of access to be of larger width than that required under 4.3 and 4.3.1.
4.3.5 In existing built-up areas in the case of plots facing street/means of access less than 4.5 m in width, the plot boundary shall be shifted to be away by 2.25 m from the central line of the street/means of accessway to give rise to a new street/means of accessway of 4.5 m width.
4.4 The means of access shall be levelled, metalled, flagged, paved, sewered, drained, channelled, lighted,
laid with water supply line and provided with trees for shade to the satisfaction of the Authority free of encroachment by any structure or fixture so as not to reduce its width below the minimum required under 4.3 and shall be maintained in a condition to the satisfaction of the Authority.
4.4.1 If any private street or any other means of access to a building is not levelled, metalled, flagged or paved, sewered, drained, channelled, lighted or laid with water supply line or provided with trees for shade to the satisfaction of the Authority, who may, with the sanction of the Authority, by written notice require the owner or owners of the several premises fronting or adjoining the said street or other means of access or abutting thereon or to which access is obtained through such street or other means of access or which shall benefit by works executed, to carry out any or more of the aforesaid requirements in such manner as he shall direct.
4.4.2 If any structure or fixture is set upon a means of access so as to reduce its width below the minimum required, the Authority may remove the same further and recover the expenses so incurred from the owner.
Provision for driver's rest room for non-residential building shall be made.
b) Fire and building services/utilities in accordance with the provisions of other Parts/Sections of the Code.
c) Topmost podium slab which is open to sky maybe landscaped and/or be used as recreational open space; subject to provision of 1.6 m high parapet wall.
d) Other habitable uses may be allowed by counting it in FAR subject to light, ventilation and fire safety requirements.
Uses proposed in (a) to (c), shall not be counted towards FAR.
Following requirements shall be satisfied for buildings constructed on podium:
a) A podium may be permitted in a plot of area 1 500 m² or more.
b) A podium, if provided with ramp, may be permitted in one or more levels, however the total height shall not exceed 30.0m above ground level.
c) In case a podium is not provided with ramp, but provided with car lift only, the same may also be permitted in one or more levels, however, the total height shall not exceed 9.0 m above ground level.
d) Requirements for ramp for vehicles (see Fig. 8B):
One way ramp of clear width of minimum 3.0 m and two way ramp with clear width of minimum 6.0 m shall be provided for LMV.
One way ramp of clear width of minimum 4.5 m and two way ramp with clear width of minimum 9.0 m shall be provided for LCV.
One way ramp of clear width of minimum 6.0 m and two way ramp with clear width of minimum 12.0 m shall be provided for HMV.
Ramp slope shall be maximum 1 in 8.
After a 40 m length of continuous ramp, a flat surface of minimum 6.0 m length shall preferably be provided (see Fig. 8B).
If podium is accessible to fire tender, minimum 7.5 m wide ramp shall be required for fire engine access with maximum slope of 1 in 10.
e) Podium shall not be permitted in required minimum front open space.
f) Podium, if accessible to fire tender, shall be so designed so as to take the load of fire tender weighing up to 45 t minimum or as per the requirement laid down by the Fire Department.
g) Requirement of accessibility for elders and persons with disabilities shall be ensured in compliance with the provisions of Annex B which may require providing ramps with specified gradient or accessible lifts for access to different levels.
a) Buildings having height more than 15 m above ground level shall necessarily be accessible by fire tender, as follows (see Fig. 9A):
For buildings having floor area less than 10 000 m² , fire tenders shall have access to at least one-third of the perimeter of building which shall be minimum 6.0 m wide and having 9.0 m turning radius.
For buildings having floor area more than 10 000 m², fire engine shall have an access to at least to half of the perimeter of building which shall be minimum 6.0 m wide and having 9.0 m turning radius.
b) If podium is not accessible by fire tender, the podium may be such that it is not extended beyond the building footprint to an extent more than 11.0 m on the side where fire tender access is provided (see Fig. 9B and Fig. 9C). Such restriction shall not apply in case podium is accessible by fire engine (see Fig. 9D).
c) Minimum 6.0 m driveway width and 9.0 m width at turning shall be available for fire tender movement all around the podium.
NOTE — The width and turning radius of ramp for fire tender access, and requirements of motorable open space for fire tender movement given above pertain to fire tender weighing up to 45 t and its operability. For heavier fire tenders, these shall be as per the requirement laid down by the Fire Department [see also 4.6 (c)].
4.7 Cul-de-sacs giving access to plots and extending from 150 m to 275 m in length with an additional turning space at 150 m will be allowed only in residential areas, provided cul-de-sacs would be permissible only on straight roads and further provided the end of cul-de-sacs shall be higher in level than the level of the starting point of such dead end road. The turning space, in this case shall be not less than 81 m² in area, with no dimension less than 9 m.
| As per requirement |
| a) Petrol/diesel filling and servicing centre — May be permitted in central as well as sub-central business district, district centres, community centres (only filling station), residential and industrial use zones in urban areas, along the national highways, state highways, villages identified as growth centres, freight complex, proposed major roads and police/security force services (for captive use only). |
| 1) Locationi) Shall not be located on the road having right of way less than 30 m.ii) Shall be approved by the explosive/fire department.iii) Special cases in old city areas may be considered based on the approval by statutory authorities. | 1) Locationi) Shall not be located on the road having right of way less than 30 m.ii) Shall be approved by the explosive/fire department.iii) Special cases in old city areas may be considered based on the approval by statutory authorities. |
| 2) Area/Sizei) Only filling station | 30 m × 17 m |
| ii) Filling cum service station | 36 m × 30 m |
| iii) Filing cum service station cum workshop | 45 m × 36 m |
| iv) Filling station only for two and three wheelers | 18 m × 15 m |
| b) Compressed natural gas (CNG) filling centre — Permitted in all use zones (except in regional parks and developed district parks) and along the national highways, state highways and villages identified as growth centres, freight complex and on proposed major roads. | b) Compressed natural gas (CNG) filling centre — Permitted in all use zones (except in regional parks and developed district parks) and along the national highways, state highways and villages identified as growth centres, freight complex and on proposed major roads. |
| 1) Locationi) Shall not be located on the road having right of way less than 30 m.ii) Shall be approved by the explosive/fire department. | 1) Locationi) Shall not be located on the road having right of way less than 30 m.ii) Shall be approved by the explosive/fire department. |
| 2) Area/Size for CNG mother station (including building component — control rooms/office/dispensing room/store, pantry and W.C.) | 1 080 m² (36 m × 30 m) |
| c) LPG godowns/Gas godown — 1 for every 40 000 to 50 000 populationThe major concern for its storage and distribution is the location which shall be away from the residential areas and shall have open spaces all around as per The Explosive Rules, 2008 | c) LPG godowns/Gas godown — 1 for every 40 000 to 50 000 populationThe major concern for its storage and distribution is the location which shall be away from the residential areas and shall have open spaces all around as per The Explosive Rules, 2008 |
| 1) Capacity – 500 cylinders or 8 000 kg of LPG | 1) Capacity – 500 cylinders or 8 000 kg of LPG |
| 2) Area (inclusive of guard room) | 520 m² (26 m × 20 m) |
| d) Milk distribution booth — 1 milk booth for every 5 000 populationArea inclusive of service area | 150 m² |
| e) Fruit and vegetable distribution booth — 1 booth for every 5 000 population Area | 250 m² |
| 5.5.5 Police, Civil Defence and Home Guards | 5.5.5 Police, Civil Defence and Home Guards |
| Land Area Required, Min | Land Area Required, Min |
| a) Police station — 1 for every 90 000 populationArea (inclusive of essential residential accommodation; 0.05 ha additional to be provided for civil defence and home guards) | 1.50 ha |
| b) Police post — 1 for every 40 000 to 50 000 population(not served by a police station)Area (inclusive of essential residential accommodation) | 0.16 ha |
| c) District office and battalion — 1 for every 1 000 000 population | |
| Total area: | 4.80 ha |
| 1) Area for district office | 0.80 ha |
| 2) Area for battalion | 4.00 ha |
| d) Police line — 1 for every 2 000 000 population | |
| Area | 4.00 to 6.00 ha |
| e) District jail — 1 for every 1 000 000 population | |
| Area | 10.00 ha |
| f) Civil defence and home guards — 1 for every 1 000 000 population | |
| Area | 2.00 ha |
| g) Traffic and police control room | |
| Area | As per requirement |
| h) Police training institute/college — 1 at city level | |
| 1) Location — To be located in fringe areas | |
| 2) Area | 5.00 ha |
| j) Police firing range — 1 at city level | |
| 1) Location — To be located in fringe areas | |
| 2) Area | Up to 10.00 ha |
| k) Police camp including Central Police Organization/security forces (including Central security forces) | |
| Area | Up to 10.00 ha |
| m) Police booth (to be provided by transport planners) | |
| 1) Location — at major road intersections | |
| 2) Area | 10 to 12 m² |
5.5.6 Safety Management
| Land Area Required, Min | |
| a) Fire station — 1 for every 200 000 population or 1 within 5 to 7 km radius | |
| Area inclusive of residential accommodation | 1.00 ha |
| b) Sub fire station/fire post — 1 within a radius of 3 to 4 km | |
| Area inclusive of essential residential accommodation | 0.6 ha |
| c) Disaster management centre — 1 in each administrative zone | |
| Area | 1) 1.00 ha along with suitable open area |
| 2) 2.00 ha if soft parking, temporary shelter, parade ground, etc, included | |
| d) Fire training institute/college | |
| Area | 3.0 ha |
5.5.7 Telephone, Postal and Banking Facilities
| Land Area Required, Min | |
| a) Telephone and Communications | a) Telephone and Communications |
| 1) Telephone exchange of 40 000 lines — 1 for every 400 000 population Area | 4.00 ha |
| 2) Radio/TV station — 1 for every 500 000 to 800 000 population Area | 1700 m² |
| 3) Remote subscriber unit (RSU) — 1 for 3 km radius Area | 300 m² |
| b) Postal | b) Postal |
| 1) Post office counter without delivery — 1 for every 15 000 population Floor area to be provided in local shopping centre | 85 m² |
| 2) Head post office with delivery office — 1 for 250 000 population Area | 750 m² |
| 3) Head post office and administrative office — 1 for 500 000 population Area | 2500 m² |
| c) Banking | c) Banking |
| 1) Bank with extension counters with ATM facility — 1 for every 15 000 population | |
| i) Floor area for counters | 75 m² |
| ii) Floor area for ATM | 6 m² |
| 2) Bank with locker, ATM and other banking facilities — 1 for 100 000 population | |
| Area | 2 500 m² |
5.5.8 Sports Facilities
| Land Area Required, Min | |
|---|---|
| a) Divisional sports centre — 1 for 1 000 000 population Area | 20.00 ha |
| b) District sports centre — 1 for 100 000 population Area | 8.00 ha |
| c) Neighbourhood play area — 1 for 15 000 population Area | 1.50 ha |
| d) Residential unit play area — 1 for 5 000 population Area | 5 000 m2 |
5.5.9 Commercial Centres
| Land Area Required, Min | |
|---|---|
| a) Convenience shopping — 1 for every 5 000 populationArea | 1 500 m² |
| b) Local shopping including service centre — 1 for every 15 000 populationArea | 4 600 m² |
| c) Community centre with service centre — 1 for every 100 000 populationArea | 5.00 ha |
| d) District centre — 1 at district level/1 for every 500000 populationArea | 40.00 ha |
| e) Sub-city centre — 1 for every 2 500 000 to 5 000 000 populationArea | As per requirement |
| f) City centre — 1 for every 5 000 000 plus populationArea | As per requirement |
| g) Local wholesale market/Mandi — 1 for 1 000 000 populationArea | 10.00 ha |
| h) Weekly markets — 1 to 2 locations for every 100 000 population with 300to 400 units per location | |
| Parking and other open spaces with in the commercial centres can be so designed that weekly markets may operate in these areas during non-working hours. | |
| The area of informal sector should have suitable public conveniences and solid waste disposal arrangements. | |
| Area per location | 0.40 ha |
| j) Organized informal eating spaces — 1 for every 100 000 populationArea | 2 000 m² |
5.5.10 Electrical Sub-Station
| Land Area Required, Min | |
| a) 11 kV sub-station — 1 for 15 000 populationArea | 500 m² |
| b) 66 kV sub-station — 2 for 100 000 populationArea for each sub-station | 6 000 m² (that is, 60 m × 100 m) |
| c) 220 kV sub-station — 1 for 500 000 populationArea | 4.00 ha |
| 5.5.11 Transport | |
| Land Area Required, Min | |
| a) Three wheeler and taxi stand — 1 for 15 000 populationArea | 500 m² |
| b) Bus terminal — 1 for 100 000 populationArea | 4 000 m² |
| c) Bus depot — 1 for 500 000 populationArea | 2.00 ha |
| 5.5.12 Cremation/Burial GroundThe site shall not be in proximity to residential areas and should preferably be in urban extension. | |
| Land Area Required, Min | |
| a) Electric crematorium — 1 for large size townsArea | 2.00 ha |
| b) Cremation ground — 1 for 500 000 populationArea | 2.50 ha |
| c) Burial ground — 1 for 500 000 populationArea | 4.00 ha |
| 5.5.13 Dhobi Ghat | |
| Land Area Required, Min | |
| Dhobi ghat with appropriate arrangements for water and drainage facilitiesand it shall be ensured that the water bodies are not polluted as a result of such activities 1 for 100 000 populationArea | 5 000 m² |
5.6 Every layout or subdivision shall take into account the provisions of development plan and if the land is affected by any reservation for public purposes, the Authority may agree to adjust the location of such reservations to suit the development.
higher than the height specified in the subject notification shall be planted on any land within the specified radius from the aerodrome reference point, as given in the notification.
9.5.1.2 In the case of buildings or structures to be erected in the vicinity of defence aerodromes, the maximum height of such buildings shall be decided by the Defence Authority.
9.5.2 The location of slaughter house/butcher house and other areas for activities like depositing of garbage dumps which would attract high flying birds like eagles/hawks, etc, shall not be permitted within a radius of 10 km from aerodrome reference point.
| xvi) | 400 | 35 | 4.00 |
building/on-site. This can also be permitted in basement areas (see 12.9) and in podium (see 4.6.1) and the footprint for the basement parking may exceed the ground coverage of the building subject to no basement building construction to cross the building line and all other safety features for structural, fire, health and public safety being ensured (see also 12.9.2.2 and Fig. 11).
11.6.2 The water body should be protected by ensuring that no permanent/temporary construction/development takes place around it up to a distance of 50m from the edge of the water body and the same shall be suitably landscaped. Further, the public shall have easy access to the water body.
11.6.3 The rain water run off shall be suitably directed to recharging wells in plots belonging to the local authority and of appropriate design. The local authority should encourage for collection of rain-water from roofs and terraces and direct the same either to a storage tank or to a recharging well. These shall be done in accordance with Part 9 ‘Plumbing Services (including Solid Waste Management), Section 2 Drainage and Sanitation’ of the Code.
11.6.4 Buildings having central air conditioning plants requiring water for cooling purposes may not be allowed to use fresh water for the purpose.
11.6.5 Commercial or residential multi-storeyed complexes may use recycled water for flushing of toilets, horticulture and fire fighting purposes. Separate storage tanks and separate distribution pipes shall be provided for the purpose.
f) The access to the basement shall be separate from the main and alternative staircase providing access and exit from higher floors. Where the staircase is continuous in the case of buildings served by more than one staircase, the same shall be of enclosed type serving as a fire separation from the basement floor and higher floors. Open ramps shall be permitted if they are constructed within the building line subject to the provision of (d);
g) Access to basements through ramps shall be permitted subject to provision of (d). The requirements for the ramps shall be in accordance with 4.6.1.3 [see also Fig. 8 (b)];
h) For all public buildings and uses including group housing, having basement going up to more than one level, access to all levels shall also be provided through lift.
The exit requirements in basements shall comply with the provisions of Part 4 ‘Fire and Life Safety’ of the Code.
The chimneys shall be built at least 0.9 m above flat roofs, provided the top of the chimneys is not below the top of the adjacent parapet wall. In the case of sloping roofs, the chimney top shall not be less than 0.6 m above the ridge of the roof in which the chimney penetrates.
Parapet walls and handrails provided on the edges of roof terraces, balcony, Verandah, etc, shall not be less than 1.0m and not more than 1.2m in height from the finished floor level.
The size of cabins shall not be less than 3.0 m² with a minimum width of 1.0 m. The clear passages within the divided space of any floor shall not be less than 0.75 m and the distance from the farthest space in a cabin to any exit shall not be more than 18.5 m. In case the subdivided cabin does not derive direct
lighting and ventilation from any open spaces/ mechanical means, the maximum height of the cabin shall be 2.2 m.
The height of a bathroom or water-closet measured from the surface of the floor to the lowest point in the ceiling (bottom of slab) shall not be less than 2.1 m.
The area of a bathroom shall not be less than 1.8 m² with a minimum width of 1.2 m . The floor area of water-closet shall be 1.1 m² with a minimum width of 0.9 m . If bath and water-closet are combined, its floor area shall not be less than 2.8 m² with a minimum width of 1.2 m .
Every bathroom or water-closet shall,
a) be so situated that at least one of its walls shall open to external air;
b) not be directly over or under any room other than another water-closet, washing place, bath or terrace, unless it has a water-tight floor;
c) have the platform or seat made of water-tight non-absorbent material;
d) be enclosed by walls or partitions and the surface of every such wall or partition shall be finished with a smooth impervious material to a height of not less than 1 m above the floor of such a room;
e) be provided with an impervious floor covering, sloping towards the drain with a suitable grade and not towards Verandah or any other room; and
f) have a window or ventilator, opening to a shaft or open space, of area not less than 0.3 m² with side not less than 0.3 m .
12.4.4 No room containing water-closets shall be used for any purpose except as a lavatory and no such room shall open directly into any kitchen or cooking space by a door, window or other opening. Every room containing water-closet shall have a door completely closing the entrance to it.
The minimum head-room of ledge or Tand/loft shall be 2.2m. The maximum height of loft shall be 1.5m.
A ledge or TAND/loft in a habitable room shall not cover more than 25 percent of the area of the floor on which it is constructed and shall not interfere with the ventilation of the room under any circumstances.
Wells, intended to supply water for human consumption or domestic purposes, where provided, shall comply with the requirements of 12.14.1 and 12.14.2.
The well shall be located,
a) not less than 15 m from any ash pit, refuse pit, earth closet or privy and shall be located on a site upwards from the earth closet or privy;
b) not less than 18 m from any cess pit soakway or borehole latrine and shall be located on a site upwards from the earth closet or privy;
c) such that contamination by the movement of sub-soil or other water is unlikely; and
d) not under a tree or otherwise it should have a canopy over it, so that leaves and twigs may not fall into the well and rot.
The well shall,
a) have a minimum internal diameter of not less than 1 m;

b) be constructed to a height not less than 1 m above the surrounding ground level, to form a parapet or kerb and to prevent surface water from flowing into a well, and shall be surrounded with a paving constructed of impervious material which shall extend for a distance of not less than 1.8 m in every direction from the parapet from the kerb forming the well head and the upper surface of such a paving shall be sloped away from the well;
c) be of sound and permanent construction (Pucca) throughout. Temporary or exposed (Kutcha) wells shall be permitted only in fields or gardens for purposes of irrigation; and
d) have the interior surface of the lining or walls of the well be rendered impervious for a depth of not less than 1.8 m measured from the level of the ground immediately adjoining the well-head.
The requirements of the boundary wall are given below:
a) Except with the special permission of the Authority, the maximum height of the compound wall shall be 1.5 m above the centre line of the front street. Compound wall up to 2.4 m height may be permitted if the top 0.9 m is of open type construction of a design to be approved by the Authority.
b) In the case of a corner plot, the height of the boundary wall shall be restricted to 0.75 m for a length of 10 m on the front and side of the intersections and the balance height of 0.75 m, if required in accordance with (a) may be made up of open type construction (through railings) and of design to be approved by the Authority.
c) However, the provisions of (a) and (b) are not applicable to boundary walls of jails. In industrial buildings, electric substations, transformer stations, institutional buildings like sanitoria, hospitals, industrial buildings like workshops, factories and educational buildings like schools, colleges, including hostels, and other uses of public utility undertakings and strategically sensitive buildings, a height up to 2.4 m may be permitted by the Authority.
Where a septic tank is used for sewage disposal, the location, design and construction of the septic tank shall conform to requirements of 12.15.1 and 12.15.2 [see also Part 9 ‘Plumbing Services (including Solid Waste Management), Section 2 Drainage and Sanitation’ of the Code].
A subsoil dispersion system shall not be closer than 18 m from any source of drinking water, such as well, to mitigate the possibility of bacterial pollution of water supply. It shall also be as far removed from the nearest habitable building as economically feasible but not closer than 6 m, to avoid damage to the structures.
a) Dimensions of septic tanks — Septic tanks shall have a minimum width of 750 mm, a minimum depth of 1 m below the water level and a minimum liquid capacity of 1 m³. The length of tanks shall be 2 to 4 times the width;
b) Septic tanks may be constructed of brickwork, stone masonry, concrete or other suitable materials as approved by the Authority;
c) Under no circumstances shall effluent from a septic tank be allowed into an open channel drain or body of water without adequate treatment;
d) The minimum nominal diameter of the pipe shall be 100 mm. Further, at junctions of pipes in manholes, direction of flow from a branch connection shall not make an angle exceeding 45° with the direction of flow in the main pipe;
e) The gradients of land drains, under-drainage as well as the bottom of dispersion trenches and soakways shall be between 1:300 and 1:400;
f) Every septic tank shall be provided with ventilating pipe of at least 50 mm diameter. The top of the pipe shall be provided with a suitable cage of mosquito-proof wire mesh.
The ventilating pipe shall extend to a height which would cause no smell nuisance to any building in the area. Generally, the ventilating pipe may extend to a height of about 2 m, when the septic tank is at least 15 m away from the nearest building and to a height of 2 m above the top of the building when it is located closer than 15 m;
g) When the disposal of septic tank effluent is to a seepage pit, the seepage pit may be of any suitable shape with the least cross-sectional dimension of 0.90 m and not less than 1.00 m in depth below the invert level of the inlet pipe. The pit may be lined with stone, brick or concrete blocks with dry open joints which should be backed with at least 75 mm of clean coarse aggregate. The lining above the inlet level should be finished with mortar. In the case of pits of large dimensions, the top portion may be narrowed to reduce the size of the RCC cover slabs. Where no lining is used, specially near trees, the entire pit should be filled with loose stones. A masonry ring may be constructed at the top of the pit to prevent damage by flooding of the pit by surface runoff. The inlet pipe may be taken
down a depth of 0.90 m from the top as an anti-mosquito measure; and
h) When the disposal of the septic tank effluent is to a dispersion trench, the dispersion trench shall be 0.50 m to 1.00 m deep and 0.30 m to 1.00 m wide excavated to a slight gradient and shall be provided with 150 mm to 250 mm of washed gravel or crushed stones. Open jointed pipes placed inside the trench shall be made of unglazed earthenware clay or concrete and shall have a minimum internal diameter of 75 mm to 100 mm. Each dispersion trench shall not be longer than 30 m and trenches shall not be placed closer than 1.8 m.
In the case of multi-storeyed multifamily dwelling apartments constructed by existing and proposed Cooperative Housing Societies or Apartment Owners Associations, limited companies and proposed societies, an office-cum-letter box room of dimension 3.6 m × 3 m shall be provided on the ground floor. In case the number of flats is more than 20, the maximum size of the office-cum-letter box room shall be 20 m² .
Provision shall be made for letter boxes on the entrance floor as per the requirements of the postal department.
For all buildings above 15 m in height and in special occupancies, like educational, assembly, institutional, industrial, storage, hazardous and mixed occupancies with any of the aforesaid occupancies having area more than 500 m² on each floor, provision shall be made for an independent and ventilated meter (service) room, as per requirements of electric (service) supply undertakings on the ground floor with direct access from outside for the purpose of termination of electric supply from the licensee's service and alternative supply cables. The door/doors provided for the service room shall have fire resistance of not less than two hours.
12.18.1 The minimum width, minimum tread width and maximum riser of staircases for buildings shall be as given in 12.18.1.1 to 12.18.1.3 (see also Part 4 'Fire and Life Safety' of the Code).
The following minimum width shall be provided for staircases for respective occupancies (see 7.1 and Part 4 ‘Fire and Life Safety’ of the Code for classification of buildings based on occupancy):
a) Residential (A-2) : 1.00 m NOTE — For row housing with 2 storeys, the minimum width shall be 0.75 m.
b) Residential (A-1, A-3 and A-4) : 1.25 m
c) Residential hotel (A-5 and A-6) : 1.50 m
d) Assembly : 2.00 m NOTE — The width of stairs may be accepted to be 1.50 m in case of assembly occupancy having less than 150 persons
e) Educational : 1.50 m
f) Institutional : 2.00 m
g) All other occupancies : 1.50 m
The minimum width of tread without nosing shall be 300 mm. However, for one or two family dwelling, it may be reduced to not less than 250 mm.
The maximum height of riser shall be 150 mm. However, for one or two family dwelling, it may be increased to not more than 190 mm. The number of risers shall be limited to 12 per flight.
12.18.2 The minimum head-room in a passage under the landing of a staircase shall be 2.2m. The minimum clear head-room in any staircase shall be 2.2m.
All aspects of exit requirements for corridors, doors, staircases, ramps, etc, in respect of widths, travel distance shall be as per Part 4 ‘Fire and Life Safety’ of the Code.
12.19.1 The roof of a building shall be so designed and constructed as to effectively drain water by means of sufficient rain water pipes of adequate size, wherever required, so arranged, jointed and fixed as to ensure that the rain water is carried away from the building without causing dampness in any part of the walls, roof or foundations of the building or an adjacent building.
12.19.2 The Authority may require rain water pipes to be connected to a drain or sewer to a covered channel formed beneath the public footpath to connect the rain-water pipe to the road gutter or in any other approved manner.
12.19.3 Rain-water pipes shall be affixed to the outside of the external walls of the building or in recesses or chases cut or formed in such external walls or in such other manner as may be approved by the Authority.
12.19.4 It is desirable to conserve rain water using suitable rain water harvesting techniques including by
roof water collection. In this context, reference shall be made to Part 9 ‘Plumbing Services (including Solid Waste Management), Section 2 Drainage and Sanitation’ of the Code.
13.1.1 These requirements deal with barrier free access to, movement within and around buildings, by the elderly persons and persons with disabilities who may have non-ambulatory disabilities, ambulatory disabilities, sight disabilities, hearing disabilities, disabilities of inco-ordination, ageing, allergies, heart and lung diseases, epilepsy, haemophilia, incontinence, enterostomy, etc.
It is intended to make all buildings and facilities used by the public accessible to, and usable by all people including those living with disabilities and may include those with inability to walk or difficulty in walking, reliance on walking/mobility aids, blindness and visual impairments, speech and hearing impairments, in-coordination of motor movements, reaching and manipulation, lack of stamina, difficulty in interpretation and reacting to sensory information and extremes in physical sizes. It supplements the general requirements of this Part of the Code, and reflects greater concern for safety of life and limb of every resident irrespective of age, gender or abilities.
13.1.2 These requirements apply to all buildings and facilities open to and used by the public. These shall also apply to all forms of public housing by the government/civic bodies or private developers. It does not apply to private residences. For extent of application of requirements covered under 13 to different building occupancy types, reference shall be made to 13.5.
13.1.3 The reference to the accessibility needs of persons with disabilities, made in this Part shall also mean a reference to such needs of the elderly persons, children and persons of too short stature in so far as the concerned provision is applicable to the type of disabilities that may be associated therewith.
13.2 For the purpose of this clause, the following definitions shall apply.
13.2.1 Ability — identifiable human attribute, including but not exclusively, to walk, to speak, to hear, to see, to feel by touch, to taste, to understand, and to recognize.
13.2.2 Access Aisle — An accessible pedestrian space between elements, such as parking spaces, seating and desks, that provides clearances appropriate for use of the elements
13.2.3 Accessible Site, Building, Facility or Portions — A site, building, facility, or portions thereof that complies with the requirements given in this clause to
which people, regardless of their disability, age or gender are able to gain access to, in to them, to use them and exit from them with dignity.
NOTE — Accessibility includes ease of independent approach, entry, evacuation and/or use of a building and its services and facilities, by all of the building's potential users with an assurance of individual health, safety and welfare during the course of those activities.
13.2.4 Accessible Route — A continuous unobstructed path connecting all accessible elements and spaces in a building or facility that may be negotiated by a person with disability using a wheelchair and that is also safe for and usable by persons with other disabilities. Interior accessible routes may include corridors, ramps, elevators, lifts, and clear floor space at fixtures. Exterior accessible routes may include parking, access aisles, kerb ramps, walkways, pathways, footpaths/sidewalks, and ramps.
13.2.5 Accessible Toilet — A compartment having the basic requirements of minimum clear spaces, water-closet, washbasin and other essential washroom accessories as required by people with non-ambulatory disabilities. There are also toilets for ambulant disabled which provide accessibility for convenient use by persons with ambulatory disabilities.
13.2.6 Ageing — Those manifestations of the ageing processes that significantly reduce mobility, flexibility, coordination, and perceptiveness but are not accounted for in disability categories mentioned elsewhere in this Part.
13.2.7 Area of Rescue Assistance — Building space directly adjoining, and visible from, a main vertical evacuation route, robustly and reliably protected from heat, smoke and flame during and after a fire, where people can temporarily wait with confidence for further information, instructions, and/or rescue assistance, without obstructing or interfering with the evacuation travel of other building users
NOTE — ‘Robust’ means structurally hardened and resistant to mechanical damage during the fire and for a period of time afterwards, that is, the cooling phase.
13.2.8 Assistive Product/Device — Product/device especially produced or generally available, for preventing, compensating for, monitoring, relieving or neutralizing impairments, activity limitations and participation restrictions.
13.2.9 Assisted Evacuation — Strategy that exists during which a designated person or persons provide assistance, during an emergency, to another person to leave a building or a specific part of the built environment and to reach a final place of safety.
13.2.10 Automatic Door — A door equipped with a power operated mechanism and controls that open and close the door automatically upon receipt of a
momentary signal. The switch that begins the automatic cycle may be photoelectrical device, floor mat, sensing device, or manual switch mounted on or near the door itself.
13.2.11 Circulation Path — An exterior or interior way of passage from one place to another for pedestrians, including walkways, pathways, hallways, courtyards, stairways and stair landings.
13.2.12 Circulation Space — Unobstructed space necessary for access to, into and within and egress from any part of the built environment.
13.2.13 Clear — Unobstructed.
13.2.14 Colour Contrast — The difference in colour that makes an object (or its representation in an image or display) distinguishable. It is determined by the difference in the colour of the object and other objects within the same field of view. Distinguishing one form/object from another by hue is the most basic and easily understood contrast.
NOTE — The basic guidelines for making effective colour choices are based on the hue value of the colours. The most commonly used methods of achieving colour contrast incorporate either harmonizing or contrasting colour combinations. Contrast of hue is what relates most directly to the colour wheel combinations. The further away from each other two colours are, the higher the contrast. This means that the complementary colour combination has the highest contrast, while the analogous combination has the lowest.
13.2.15 Disability — An umbrella term for impairments, activity limitations, and participation restrictions, denoting the negative aspects of the interaction between an individual (with a health condition) and that individual's contextual factors(environmental and personal factors). Disability is neither simply a biological nor a social phenomenon but arises from the relationship between health condition and context.
13.2.16 Grab Bars — A bar used to give a steadying or stabilizing assistance to a person engaged in a particular function.
13.2.17 Handrails — A rail used in circulation areas such as corridors, passageways, ramps and stairways to assist in continuous movement.
13.2.18 Hue — Attribute of visual sensation which has given rise to colour names, such as, blue, green, yellow, red and purple.
NOTE — People with normal colour vision report that hues follow a natural sequence based on their similarity to one another. With most colour deficits, the ability to discriminate between colours on the basis of hue is diminished.
13.2.19 Impairment — Limitation in body function or structure such as a significant deviation or loss which can be temporary due, for example to injury, or permanent, slight or severe and can fluctuate over time, in particular, deterioration due to ageing.
NOTE — Body function can be a physiological or psychological function of a body system; body structure refers to an anatomic part of the body such as organs, limbs and their components.
13.2.20 International Symbol of Accessibility — The symbol consisting of a square overlaid with a stylized image of a person using a wheelchair (see B-24.2.16 and Fig. 105).
NOTE — The symbol is often provided where access has been improved, particularly for wheelchair users and other mobility impaired persons. The symbol denotes a barrier free environment, to help older people, parents with prams and travellers with luggage besides persons with disabilities. The wheelchair symbol is always facing to the right.
13.2.21 Kerb — A side barrier to a trafficable surface or the edge where a raised sidewalk/footpath, road median, or road shoulder meets an unraised street or other roadway.
13.2.22 Kerb Ramp — A short ramp cutting through a kerb or built up to it.
13.2.23 Knurled Surface — Roughened area, often in a crisscross pattern; used on grab bars to improve grasp and to prevent slipping.
13.2.24 Landing — A platform or part of a floor structure at the end of a flight of stairs or a ramp or at the entrance to a lift car.
13.2.25 Light Reflectance Value (LRV) — The total quantity of visible light reflected by a surface at all wavelengths and directions when illuminated by a light source.
13.2.26 Manoeuvring Zone — The minimum three dimensional space within which it is feasible to complete a manoeuvre needed to gain access to a specific facility, component or fitting, in particular while using a wheelchair or a walking aid.
13.2.27 Ramp — The construction, in the form of an inclined plane that is steeper than or equal to 1:20 (5 percent) from the horizontal, together with any intermediate landing, that makes it possible to pass from one level to another (see B-6.2).
13.2.28 Operable Parts — A part of a piece of equipment or appliance used to insert or withdraw objects, or to activate, deactivate, or adjust the equipment or appliance (for example coin slot, push button, handle, etc).
13.2.29 Persons with Disabilities — A person with any physical, mental, intellectual or sensory impairment which in interaction with various barriers may hinder full and effective participation in society on an equal basis with others.
13.2.30 Space — A definable area (for example toilet room, hall, assembly area, entrance, storage, room alcove, courtyard, or lobby).
13.2.31 Tactile — That relating to perception using the sense of touch.
NOTE — It relates to information and interpretations derived from the sense of touch. This involves sensory transfer through physical contact of the hands or feet with other surfaces, as well as sensory transfers received by contact with non-physical elements such as pressure, wind and temperature.
13.2.32 Tactile Ground Surface Indicators — Indicators profiled paving surface with visual contrast criteria to enable a person with impaired sight using a long cane, underfoot or visual identification to detect a specific route (guiding pattern) or the presence of a hazard (attention pattern). These are also called tactile tiles or tactile walking surface indicators.
NOTE — These indicators which provide a distinctive surface pattern of strips and truncated domes or cones (small domes or cones that have had their tops cut off, or truncated) are used to guide/alert persons with vision impairments of their approach to facilities, streets and hazardous drop-offs. People who are blind or visually impaired are alerted of impending danger from vehicle impact or a grade change.
13.2.33 Tactile Guiding Blocks — Tiles of size 300 mm × 300 mm that incorporate flat topped bars 5 mm ( ± 0.5 mm ) high, 20 mm wide and spaced 50 mm from the centre of one bar to the centre of the next, and are easily detectable underfoot by persons with visual impairments. They are used externally to guide people with visual impairments along the circulation path. They may also be used internally in large busy areas such as railway stations and airports.
13.2.34 Tactile Warning Blocks — Tiles of size 300 mm × 300 mm that incorporate rows of 5 mm ( ± 0.5 mm ) high flat topped blister like domes that are easily detectable underfoot by persons with visual impairments, recognized as a sign of approaching hazards. These are placed along the approach path to unavoidable obstacles and hazards to warn persons with visual impairments of the approaching danger or level change.
13.2.35 Tactile Signs — Tactile signage incorporates raised text or symbols to enable touch reading by people who are blind, and touch enhancement of visual perception for people who are vision impaired.
13.2.36 Unobstructed Width — Free unobstructed space necessary for passage through a doorway, along a passageway, or other route element (for example stairway).
13.2.37 Unobstructed Width, Door — Available width for passage through a door opening, clear of all obstructions, measured when the door is opened 90° , or when a sliding or folding door is opened to its fullest extent
13.2.38 Unisex Accessible Toilet — Accessible toilets that can be used by both sexes.
NOTE — Unisex accessible toilets allow the greatest flexibility for people who require assistance.
13.2.39 Universal Design — The design of products and environments to be usable by all people, to the greatest extent possible, without the need for adaptation or specialized design.
13.2.40 Visual Contrast — Visual perception between one element of a building and another. This can be produced by a difference in light reflectance value (LRV) or luminance, also called luminance contrast.
NOTE — Light reflectance value is measured on a scale of 0 to 100 where 0 equals black meaning total light absorption and 100 equals white meaning total light reflection.
A simple formula for visual contrast is given below for guidance:
Visual contrast = [ (B 1 - B 2) / B 1 ] × 1 0 0, in percent
where
B 1 = LRV of the lighter area; and
B2 = LRV of the darker area.
In most circumstances, a difference in these values of 30 percent is considered adequate. However, research suggests that signs are more legible for the visually impaired when characters contrast with their background by at least 70 percent.
13.2.41 Walks (Walkways) — A predetermined prepared surface, exterior pathway leading to or from a building or facility, or from one exterior area to another, placed on the existing ground level and not deviating from the level of the existing ground immediately adjacent.
13.2.42 Way Finding — Descriptive of a system whereby appropriate information is provided to assist a person to pass through the built environment towards a specific destination.
NOTE — Way finding includes orienting oneself, knowing one's destination, following the best route, recognizing one's destination and finding one's way back out. People who are blind or who have a vision impairment benefit from tactile information to facilitate way finding.
13.2.44 Water-Closet Compartment/Toilet Cubicle — A compartment having a water-closet with grab bars installed to assist persons with physical disabilities/mobility impairments.
13.2.45 White Cane — A long rod-like device used by blind or visually impaired travellers to give them information about the environment they are travelling through.
Special requirements of low income housing shall be as given in Annex C. For detailed information in this regard, reference may be made to the accepted standard [3(3)].
With the exception of requirements given in Annex C, requirements of building shall be governed by the provision of this Code.
13.3.1 These requirements relate to the principal human
abilities that should be considered when designing, constructing and managing the built environment. Some of these abilities are described in B-1 which gives an overview of concerned design considerations that should be taken into account.
Understanding of the human abilities or limitation thereof as described below, and design aspects according to the same, when fully implemented, are expected to benefit all people:
a) Non-ambulatory disabilities — Impairments that, regardless of cause or manifestation, for all practical purposes, make an individual a wheelchair user for his mobility. The requirement of non-ambulatory disabilities relates primarily to the design of buildings, so as to meet their independent mobility needs while sitting in the wheelchair with or without assistance, minimum widths and heights, level changes and signage, etc.
b) Ambulatory disabilities — Impairments that cause individuals to walk with difficulty or insecurity of balance. Such persons are able to walk on level, either with or without personal assistance, and may depend on prostheses (artificial limbs), orthoses (calipers), sticks, crutches or walking aids or may negotiate suitably graded steps provided that convenient handrails are available. For example elders using walking sticks, ladies in advance stage of pregnancy, temporary disabilities, such as, fracture, individuals using braces or crutches, amputees, persons having arthritis, those with spasticity and those with pulmonary and cardiac ills, etc, may be ambulatory disabled.
c) Sight disabilities — Total blindness or impairments affecting sight to the extent that the individual may have to use his other sensory organs such as sense of touch and hearing, use assistive devices for orientation in the environment, such as white cane. Accordingly, building design needs to take in to account means, such as, tactile, Braille and audio-visual, and colour contrasting signage.
d) Hearing disabilities — Deafness or hearing impairment may affect an individual's verbal communication or ability to hear warning signals in the environment. The buildings needs to be designed to provide more visual signage, induction loops for hearing enhancement, emergency audio-visual sirens, etc.
e) Disabilities of incoordination — Incoordination of motor movements due to cerebral palsy, spinal injury or peripheral nerve injury.
f) People with allergies — People with allergies may be sensitive to dust, mildew, pollen, animal hair, formalin, turpentine, etc. Some are sensitive to contact with substances and materials such as nickel, chromium and rubber.
g) People with heart and lung diseases — People with heart and lung diseases may only be able to walk short distances and may be unable to climb stairs. The requirements of these people are similar to those with impaired mobility.
h) People with epilepsy, haemophilia, etc — The requirements of those with epilepsy, heamophilia, etc, are related primarily to the design of buildings and the need to minimize the risk of injury caused by falling or encountering obstacles.
j) People with incontinence, enterostomy operations, etc — The requirements of people with incontinence, enterostomy operations, etc, (colostomies, ileostomies and urostomies) are mainly related to bathroom provision. In certain circumstances, for example in public water-closet compartments, it may be desirable to provide a special sink for emptying urine bags.
k) People with hidden (such as strength, stamina, dexterity and allergy) impairments, and
m) People with diversities in age and stature (including frail persons).
Entering, using and evacuating buildings should be safe and easy for individuals, families and groups which include persons with disabilities. The main considerations are as follows:
Pedestrian access into site;
Designated vehicular parking near the main entrance;
Accessible path to the entrance;
Appropriate external lighting;
Accessible external furniture (seats, bins, etc);
Accessible information at the entrance to the site;
Suitable drop-off point near main entrance;
Reduced travelling distances;
Level entrances and exits;
Simple and logical layouts;
Unobstructed level circulation;
Easy access to information desks, lifts and toilet compartments for disabled persons;
Intuitive, obvious and accessible means of egress;
Spacious lifts;
Safe stairs that are easy to use, and facilitate safe assisted evacuation/rescue in emergencies;
Slip-resistant walking surfaces;
Wide door openings and easy door operation, sufficient space around doors that makes it possible to open and close them when seated in a wheelchair;
Adequate manoeuvring space;
Adequate height, location and easy operation of controls and switches;
Good lighting;
Good visual contrast of walls, floors, doors and signage;
Good signage;
Important information communicated via two senses or more (tactile, audible and visual);
Good acoustics;
Hearing enhancement systems; and
Management and maintenance of the built environment.
The key accessibility issues are highlighted in Table 7.
13.4 Various key accessibility issues shall be taken into account for ensuring accessibility in built environment in accordance with the provisions given in Annex B in regard to anthropometrics and specific requirements on site planning and development, designated accessible parking space, approach to the buildings, access at entrance and within the buildings, controls and operating mechanisms, seating spaces, other facilities, level changes, toilet and sanitary facilities, emergency evacuation in buildings, signages, etc. Requirements for accessibility in buildings and built environment as given in other Parts/Sections of the Code shall also be complied with.
For requirements regarding structural design, reference shall be made to Part 6 ‘Structural Design’ of the Code. For requirements regarding construction (including management and safety), reference shall be made to Part 7 ‘Construction Management, Practices and Safety’ of the Code.
20.1 For requirements regarding lighting and ventilation for different uses and occupancies, reference shall be made to Part 8 ‘Building Services’, Section 1 ‘Lighting and Natural Ventilation’ of the Code.
Rooms shall have, for the admission of light and air, one or more openings, such as windows and ventilators, opening directly to the external air or into an open Verandah.
20.1.2 Notwithstanding the area of openings obtained through 20.1, the minimum aggregate area (see Notes 1 to 3) of such openings, excluding doors inclusive of frames, shall be not less than,
a) one-tenth of the floor area for hot-dry climate;
b) one-sixth of the floor area for warm-humid climate;
c) one-eighth of the floor area for temperate and composite climate; and
d) one-twelfth of the floor area for cold climate.
1 If a window is partly fixed, the openable area shall be counted. 2 No portion of a room shall be assumed to be lighted, if it is more than 7.5 m away from the opening assumed for lighting that portion.
3 The area of openings as given in (a) to (d) above shall be increased by 25 percent in the case of a kitchen [see 12.3.3(d)].
21.1 For requirements regarding electrical installations in buildings including lightning protection of buildings, reference shall be made to Part 8 'Building Services
Section 2 Electrical and Allied Installations' of the Code.
The solar panels can be provided on roof tops and integrated photovoltaic panels on walls/windows as well as solar photovoltaic (PV) banks on open areas.
All plots having size 500 m² and above shall install solar photovoltaic power generation system. This should also be encouraged for plots smaller than 500 m² . The power generated may be used for in-house utilization or for transfer to the grid. The Authority shall have required provisions in the building bye-laws and mechanism for required clearances and approvals. The Authority shall also specify minimum generation requirement. The following may be used as a guide:
| Sl No.(1) | Building Type(2) | Plot Size(3) | Generation Requirement(4) |
|---|---|---|---|
| i) | Residential (Plotted houses) | 100 m² and above | 1 kWp or 5 percent of connected load, whichever is higher |
| ii) | Residential (Group housing) | All sizes | Minimum 5 percent of connected load |
| iii) | Business, educational buildings having connected load of 30 kW and above | 500 m² and above | 5 kWp or 5 percent of connected load, whichever is higher |
| iv) | Mercantile, hotels, motels, assembly, industrial and institutional buildings | 500 m² and above | for buildings having connected load of:a) 50-1 000 kW — 10 kWp or 5 percent of connected load whichever is higherb) Above 1 000 kW — 50 kWp or 5 percent of connected load whichever is higher |
The following building occupancy types shall install solar assisted water heating system for supplying hot water:
a) Residential buildings (except hostels of educational buildings and plotted houses) having plot area 4 000 m² and above;
b) Plotted houses having plot area of 250m² and above;
c) Hostels for schools, colleges and training centres for more than 100 students;
d) Institutional buildings; and
e) Assembly buildings
The Authority shall have required provisions in the building bye-laws and mechanism for required
clearances and approvals. The Authority, considering the availability of solar energy for harnessing, shall decide the minimum capacity be installed subject to a minimum of 25 litre per day hot water yield for each bathroom and kitchen.
For solar water heating system and their installation reference shall be made to accepted standards and good practice [3(4)].
For requirements regarding design, construction and installation of air conditioning, heating and mechanical ventilation systems, reference shall be made to Part 8 ‘Building Services, Section 3 Air Conditioning, Heating and Mechanical Ventilation’ of the Code.
Provision for lifts shall be made for buildings 15 m or more in height. For requirements regarding planning, designing and installation, etc, of lifts and escalators, reference shall be made to Part 8 ‘Building Services, Section 5 Installation of Lifts, Escalators and Moving Walks’ of the Code.
13.5 Various accessibility requirements for persons with disabilities and the elderly shall be applied to different building occupancies in accordance with Table 8, unless mentioned otherwise specifically in Annex B. In addition, all building occupancy types shall comply with the following:
a) At least one entrance preferably the main entrance per building shall be accessible. All efforts should be made to make as many/all entrances accessible.
b) All common areas open to public and staff and all facilities provided in a building for
| SI No.(1) | Key Accessibility Issues(2) | Example(3) |
|---|---|---|
| i) | Equitable approach to a building, for example designated parking, clear pedestrian routes separate from vehicles and cyclists, no steps or obstacles, short distances from parking and public transport, good signage, good lighting and good contrast | |
| ii) | Equitable entry via the same entrances, for example easy to locate main entrances, no steps or obstacles, wide openings, adequate manoeuvring space in front of the door, low operating forces, good signage, good lighting and good visual contrast | |
| iii) | Equitable use of the same paths in horizontal circulation, for example no steps or obstacles, adequate manoeuvring space, wide door openings, easy to operate doors, resting places, clear layout, good signage, good lighting and good visual contrast | |
| iv) | Equitable access to the same paths in vertical circulation, for example safe stairs, spacious lifts with easy operation, good signage, good lighting and good visual contrast | |
| v) | Equitable use of the same rooms, for example ample circulation space and different seating possibilities, good acoustics and hearing enhancement systems, good lighting and good visual contrast | |
| Table 7 — (Concluded) | Table 7 — (Concluded) | Table 7 — (Concluded) |
| (1) | (2) | (3) |
| vi) Equitable use of the same equipment and facilities, for example easy to understand and operate, adequate manoeuvring space and operating height, information via two senses | vi) Equitable use of the same equipment and facilities, for example easy to understand and operate, adequate manoeuvring space and operating height, information via two senses | |
| vii) Equitable use of toilet and sanitary facilities, for example good signage, adequate manoeuvring space, good transfer options, well-placed equipment, easy operation | vii) Equitable use of toilet and sanitary facilities, for example good signage, adequate manoeuvring space, good transfer options, well-placed equipment, easy operation | |
| viii) Equitable means of egress, concepts for emergency planning, for example no steps or obstacles, fire protected lifts, good signage, good lighting, good visual contrast, good fire safety, protection and evacuation, accessible means of egress | viii) Equitable means of egress, concepts for emergency planning, for example no steps or obstacles, fire protected lifts, good signage, good lighting, good visual contrast, good fire safety, protection and evacuation, accessible means of egress | |
| ix) Important information via two senses or more, for example visual, audible and tactile | ix) Important information via two senses or more, for example visual, audible and tactile |
| SI No.(1) | Category(2) | Type of Built Environment Within the Category(3) | Applicability(4) |
|---|---|---|---|
| i) | Residential | Public housing including low income housing and housing developed by private developers | a) All common and communal areas, such as, approach, entrances/exits, lifts, stairs, lobbies, clubs, religious facilities, parking, sports facilities/parks and recreation areas, etc, and associated sanitary and other facilities therein.b) 5 percent houses to be accessible meeting accessibility requirements, preferably on ground floor.c) In all other 95 percent houses, minimum universal design features, such as, minimum clear door widths of: main entrance, rooms, kitchen and that of at least one toilet and sanitary room in each house. Such toilet and sanitary room in the house shall be the one having access from the living/drawing room and their size shall comply with those given in B-9 to allow the occupants to adapt to their needs to facilitate ageing-in-place and disabled friendly environment.NOTE □ The provisions given in (c) are minimum prescriptions with the objective to progressively move towards universal design of the buildings and the built environment, to be usable by all people, to the greatest extent possible irrespective of their age, situation, abilities, gender or any other diversity. |
| ii) | Hotels/hospitality centres | Hotels, dormitories, lodging and rooming houses, such as inns, clubs, motels and guest houses | Minimum five percent of the total rooms including their toilet room, shower room, balcony, etc, shall be accessible and preferably be provided on the ground floor for ease of evacuation in case of an emergency.All other rooms shall have universal design features (without specific adaptations like handrails/grab bars, etc). This would include minimum clear door widths of 900 mm of all entrances including those of sanitary rooms and balcony areas; and minimum passage width of 1200 mm in the rooms and required turning radius.In accommodations having more than one toilet/sanitary room, one such facility shall be accessible.In case of accessible accommodations, a choice of right or left hand transfer to the toilet and shower shall be provided. |
| iii) | Educational buildings | Schools, colleges, classrooms, libraries, assembly points, halls, staff rooms, laboratories, play grounds | a) All teaching/administrative and common areas frequented by staff/students.b) In libraries all open book stacks. Few enclosed rooms in library for those with hearing and vision impairments who may need assistance while reading.c) In laboratories, equipment and facilities. |
| iv) | Hospitals/health facilities | Hospitals/clinics/diagnostic centres/pharmacy, etc | All public areas to be accessible, including OPDs, IPDs, wards, toilets, changing rooms, sample collection rooms, x-ray rooms, patient examination rooms, medical distribution rooms/centres. |
| v) | Assembly buildings | Stadia, theatres, lecture halls, spectator seating in sports centres and all other type of assembly halls with fix seatings, by whatever name called | To all common areas/facilities open to public and staff. Number of designated seating areas to be as per B-12.3. |
| vi) | Public transit buildings | Bus terminus, airports, railway/metro stations, organized inter-change points/transit junctions, taxi stands | All public areas used by passengers and staff including but not limited to drop off areas, parking, boarding/transfer areas, waiting areas/lounges, custom areas, baggage halls, booking halls, inquiry offices, ticket counters, shops, banks, etc. |
| vii) | Heritage buildings/sites | All heritage sites/buildings protected by concerned authorities and open to public, interpretation centres, ancillary services/ facilities | a) Reasonable access to all public areas without affecting the historical character of the building.b) Alternative solutions and innovative methods that do not conflict with conservation/preservation requirements should be explored. |
| Table 8 — (Concluded) | Table 8 — (Concluded) | Table 8 — (Concluded) | Table 8 — (Concluded) |
| (1) | (2) | (3) | (4) |
| viii) | Public toilets | To be provided in accordance with B-9.15. | |
| ix) | Cafeterias and restaurants | To be provided in accordance with B-15. | |
| x) | Sports buildings | a) Sports halls, administration and common areas.b) At least one changing room and shower room to be provided at every place where such facility is provided.c) Spectators seating areas for wheelchair users as per assembly buildings above. | |
| xi) | Mercantile buildings | Shops, malls, large multi-storey department stores and super markets, etc | At least one trial room for each group of such facility. Where only one is provided, it shall be accessible. |
public use, such as, waiting areas, seating spaces, coffee shops, display areas, merchandising departments, service areas, ticket counters and refreshment stands shall be accessible to all persons with disabilities. These shall also include facilities like, lobby toilets, lifts, saloons, bars, restaurants, eateries, clubs, swimming pool, parking, fitness centres/gymnasiums, religious facilities, sports facilities/parks and recreation areas, etc, within an occupancy.
c) In all buildings, accessible toilet and sanitary room(s) shall be provided in accordance with B-9. Such facility shall be provided in each toilet group in a building.