For the purpose of this Section, the definitions given below shall apply.
2.1 Accidental Loads — Loads due to explosion, impact of vehicles, or other rare loads for which the structure is considered to be vulnerable as per the user.
2.2 Accompanying Load — Live (imposed) load acting along with leading imposed load but causing lower actions and/or deflections.
2.3 Action Effect or Load Effect — The internal force, axial, shear, bending or twisting moment, due to external actions and temperature loads.
2.4 Action — The primary cause for stress or deformations in a structure such as dead, live, wind, seismic or temperature loads.
2.5 Actual Length — The length between centre-to-centre of intersection points, with supporting members or the cantilever length in the case of a free standing member.
2.6 Beam — A member subjected predominantly to bending.
2.7 Bearing Type Connection — A connection made using bolts in ‘snug-tight’ condition, or rivets where the load is transferred by bearing of bolts or rivets against plate inside the bolt hole.
2.8 Braced Member — A member in which the relative transverse displacement is effectively prevented by bracing.
2.9 Brittle Cladding — Claddings, such as asbestos cement sheets which get damaged before undergoing considerable deformation.
2.10 Buckling Load — The load at which an element, a member or a structure as a whole, either collapses in service or buckles in a load test and develops excessive lateral (out of plane) deformation or instability.
2.11 Buckling Strength or Resistance — Force or moment, which a member can withstand without buckling.
2.12 Built-Up Section — A member fabricated by interconnecting more than one element to form a compound section acting as a single member.
2.13 Camber — Intentionally introduced pre-curving (usually upwards) in a system, member or any portion of a member with respect to its chord. Frequently, camber is introduced to compensate for deflections at a specific level of loads.
2.14 Characteristic Load (Action) — The value of specified load (action), above which not more than a specified percentage (usually 5 percent) of samples of corresponding load are expected to be encountered.
2.15 Characteristic Yield/Ultimate Stress — The minimum value of stress, below which not more than a specified percentage (usually 5 percent) of corresponding stresses of samples tested are expected to occur.
2.16 Column — A member in upright (vertical) position which supports a roof or floor system and predominantly subjected to compression.
2.17 Compact Section — A cross-section, which can develop plastic moment, but has inadequate plastic rotation capacity needed for formation of a plastic collapse mechanism of the member or structure.
2.18 Constant Stress Range — The amplitude between which the stress ranges under cyclic loading is constant during the life of the structure or a structural element.
2.19 Corrosion — An electrochemical process over the surface of steel, leading to oxidation of the metal.
2.20 Crane Load — Horizontal and vertical loads from cranes.
2.21 Cumulative Fatigue — Total damage due to fatigue loading of varying stress ranges.
2.22 Cut-Off Limit — The stress range, corresponding to the particular detail, below which cyclic loading need not be considered in cumulative fatigue damage evaluation (corresponds to 10⁸ number of cycles in most cases).
2.23 Dead Loads — The self-weights of all permanent constructions and installations including the self-weight of all walls, partitions, floors, roofs, and other permanent fixtures acting on a member.
2.24 Deflection — It is the deviation from the standard position of a member or structure.
2.25 Design Life — Time period for which a structure or a structural element is required to perform its function without damage.
2.26 Design Load/Factored Load — A load value obtained by multiplying the characteristic load with the partial safety factor for loads.
2.27 Design Spectrum — Frequency distribution of the stress ranges from all the nominal loading events during the design life (stress spectrum).
2.28 Detail Category — Designation given to a particular detail to indicate the S-N curve to be used in fatigue assessment.
2.29 Discontinuity — A sudden change in cross-section of a loaded member, causing a stress concentration at the location.
2.30 Ductility — It is the property of the material or a structure indicating the extent to which it can deform beyond the limit of yield deformation before failure or fracture. The ratio of ultimate to yield deformation is usually termed as ductility.
2.31 Durability — It is the ability of a material to resist deterioration over long periods of time.
2.32 Earthquake Loads — The inertia forces produced in a structure due to the ground movement during an earthquake.
2.33 Edge Distance — Distance from the centre of a fastener hole to the nearest edge of an element measured perpendicular to the direction of load transfer.
2.34 Effective Lateral Restraint — Restraint that produces sufficient resistance to prevent deformation in the lateral direction.
2.35 Effective Length — Actual length of a member between points of effective restraints or effective restraint and free end, multiplied by a factor to take account of the end conditions in buckling strength calculations.
2.36 Elastic Cladding — Claddings, such as metal sheets that can undergo considerable deformation without damage.
2.37 Elastic Critical Moment — The elastic moment, which initiates lateral-torsional buckling of a laterally unsupported beam.
2.38 Elastic Design — Design, which assumes elastic behaviour of materials throughout the service load range.
2.39 Elastic Limit — It is the stress below which the material regains its original size and shape when the load is removed. In steel design, it is taken as the yield stress.
2.40 End Distance — Distance from the centre of a fastener hole to the edge of an element measured parallel to the direction of load transfer.
2.41 Erection Loads — The actions (loads and deformations) experienced by the structure exclusively during erection.
2.42 Erection Tolerance — Amount of deviation related to the plumbness, alignment, and level of the element as a whole in the erected position. The deviations are determined by considering the locations of the ends of the element.
2.43 Exposed Surface Area to Mass Ratio — The ratio of the surface area exposed to the fire (in mm²) to the mass of steel (in kg).
NOTE — In the case of members with fire protection material applied, the exposed surface area is to be taken as the internal surface area of the fire protection material.
2.44 Fabrication Tolerance — Amount of deviation allowed in the nominal dimensions and geometry in fabrication activities, such as cutting to length, finishing of ends, cutting of bevel angles, etc.
2.45 Factor of Safety — The factor by which the yield stress of the material of a member is divided to arrive at the permissible stress in the material.
2.46 Fatigue — Damage caused by repeated fluctuations of stress, leading to progressive cracking of a structural element.
2.47 Fatigue Loading — Set of nominal loading events, cyclic in nature, described by the distribution of the loads, their magnitudes and the numbers of applications in each nominal loading event.
2.48 Fatigue Strength — The stress range for a category of detail, depending upon the number of cycles it is required to withstand during design life.