Development controls have been defined as the mechanism through which entire process of urban development is regulated to achieve the objective of promoting overall benefit of the society and creating a distinct image of the city. It includes guiding the development and use of land, curbing misuse of land and promoting rational and orderly development of built environment. Development controls are required to meet situations and contexts which are generally static. In this context they tend to become to rigid and complex. Looking at the far reaching impact and implications of the development controls on the growth and development, character, fabric and personality of a city, they need to be framed with great care and abundant caution. Considering the larger public interest and general welfare of the community, formulation of the development control should satisfy the basic requirements of the health, safety convenience, economy and amenity.
16.1Need and Purpose of Development Controls and Regulations:
Chandigarh has been widely acclaimed as a Mecca of planning and architecture in view of various innovations incorporated in the planning, designing, development and management of this capital city of the state of Punjab. The city today is valued universally for being the first realization of Le Corbusier’s urban percepts and the site of his most elaborate architectural creation.
Chandigarh has been credited with extensively using mechanism of development controls for promoting state of art development and quality built environment.
In the absence of any statutory master plan, growth and development of Chandigarh has been exclusively regulated through various development controls, which have been put into operation as integral part of city planning and development process.
(ii) The Punjab Capital (Development and Regulation) Building Rules 1952
Under the provisions of above mentioned Act, The Punjab Capital (Development and Regulation) Building Rules 1952 have been formulated. These Building Rules, various administrative procedures were formulated such as procedure of submission of building
application, planning and architectural controls, materials and structural controls, drainage control etc. Building plans of all private buildings in the city are sanctioned in accordance to these Building rules. Occupancy certificates are issued only to buildings which are built as per sanctioned plans and various types of penalties are also imposed in accordance to these building Rules. These rules have been amended from time to time keeping pace with the advancements in building technology, genuine needs of the masses and various provisions in the referral publication such as NBC.
(iii) The Chandigarh (Sale of sites) Rules 1952
These rules govern the sale of various types of sites in Chandigarh either through auction or allotment.
(iv) Chandigarh Tree Preservation Order 1952
These rules were framed to preserve the protected trees, group of trees or woodland areas which form the green cover of the City. The rules prohibit cutting of trees in any part of the woodland area shown in the zoning plan.
(v) The Punjab New Capital (Periphery) Control Act 1952
Haphazard, unplanned substandard and ramshackle development around the city is regulated and controlled by ‘The Punjab New Capital (periphery) Control Act, 1952, Act, which controls and regulates the area contained in 16 kms. belt, around the new capital of Chandigarh, declared as Periphery, under the provisions of the said law. This act was formulated to ensure regulated development of the Capital City and to eliminate emergence of slums and haphazard development around the new City.
The main aim of this Act is :
To freeze the landuse in the peripheral area (primarily agricultural) and to retain its basic character. This act extended up to 16 km. built around the city.
To prevent change in landuse except as permitted.
To provide ample area for future growth
To identify areas, which will provide agricultural, diary, poultry products for day to day needs of the city.
To clearly demarcate the functions of the capital city and its periphery for evolving harmonious relationship between the two.
To provide a legal framework for achieving above objectives.
To channelize growth and development in identified areas only.
Regulations and controls
All the buildings are subjected to different development controls for regulating their design and construction. The application of the development controls have been largely dictated by the category of buildings, location of the site, size of the site and need to regulate the building design/architecture etc. Therefore, Chandigarh has put in operation following two distinct sets of development controls to regulate its growth and development both within and outside the city:
a. Zoning Regulations
b. Architectural Controls
a. Zoning Regulations
To control and regulate the development of the city in accordance with founding concept and ideas as envisaged by the Architect Planner, the Punjab Government formulated Punjab Act XXVII of 1952 under which the Capital of Punjab (Development and Regulation) Act 1952. This Act lays various mandatory rules and regulations in respect of erection of buildings in the Chandigarh Capitol Project and confers upon the Chief Administrator, Capital Project the power to frame and amend rules.
16.2Types of Development Controls and Regulations in Chandigarh:
To control and regulate the development of the city in accordance with founding concept and ideas as envisaged by the Architect Planner, various Acts/Rules and Architectural and Urban Legislations were put in place, which are as follows:-
(i) The Punjab Capital (Development and Regulation) Act 1952
Development within the city is being managed through various kinds of development controls. Development controls within the city have its genesis in ‘The Capital of Punjab (Development and Regulations) Act, 1952. Sections 4 of the said Act, empowers Chief Administrator to issue such directions, as may be considered appropriate in respect of any site or building for the proposes of proper planning or development of Chandigarh. Various rules enacted under said Act are as under:-
b. Architectural Control
The Edict of Chandigarh states that certain areas of Chandigarh are of special architectural interest where harmonized and unified composition of buildings is aimed at. In these areas, absolute architectural and zoning controls should remain operative. The planners of the city employed large scale aesthetic controls ranging from urban design measures to extensive architectural controls that prescribe volumes, outlines and skyline, forms, spatial setting, facades, materials, textures, colours, fenestrations and even boundary wall and gates. These architectural controls depict the architect’s interpretation of available technology, climate, social order of the democratic nature placed in the context of modernism. These controls were framed to provide an egalitarian out look to the urban character of the city where the facades and profiles of the built environment do not depict the socio – economic conditions of the citizens.
Types of Architectural Controls
The relaxations have been provided in the controls based on case to case basis and the representations received from time to time from the plot owners. However, most of the relaxations are provided in such a manner that the basic architectural parameters of the related buildings are not altered. Following types of Architectural Controls were made applicable in various parts of Chandigarh:
a) Full Architectural controls
b) Controls along major arterial roads
c) Frame controls
d) Architectural controls houses.
e) Controls in Sector 17 and Sub City Centre Sector 34
f) Gate and boundary walls
g) Full Architectural Controls – Phase I of Chandigarh
a) Full Architectural Controls:- Full architectural controls were created primarily for the commercial and residential buildings abutting the shopping streets (V4 roads) wherein the entire external facades and internal planning was to compulsorily comply with the standard design provided by the Government.
Houses up to 1 kanal plot area were brought under architectural controls for which design was supplied by the Government. These architectural controlled houses were in phase I sectors such as 10, 11,18,19,27 etc. However, these architectural controls have been relaxed vide notification of Chandigarh Administration dated 16.10.2008 and presently in residential houses of all categories, zoning parameters have also been made applicable simultaneously.
The Shop-cum-Flats (SCFs) abutting the V4 streets in Phase I sectors are also covered under architectural controls from the very beginning and the controls provided for mixed land use pattern i.e. shops on ground floor and living units on first floor and barsati. However, the conversion of SCF to SCO has been permitted by the Chandigarh Administration. In Phase II sectors, the full architectural controls were restricted only to commercial buildings (shop-cumoffices and booths) on V4 streets and the plotted attached houses across the street were replaced by multi storied housing.
b) Controls along major arterial roads
The architectural controls for commercial and institutional buildings were evolved for all the major arterial roads of the city - Madhya Marg (V2), Jan Marg (V2) Dakshin Marg (V2)Himalaya Marg (V2b) Shopping streets (V4) and varied from street to street in detailing but retained similar character and concept. The controls whether commercial or institutional can be classified either as brick structures or R.C.C structures or composite built forms. The commercial buildings built initially were mostly linear blocks abutting on parking spaces placed along major avenues, however subsequently the linear layout was changed to an M-shaped layout, creating parking enclosures on front and rear sides of these showrooms.
The service lane and rear courtyards were omitted. The institutional buildings of plotted development which are composed of multiple blocks of varying heights placed at angle to the avenues in order to facilitate north lights. While the tower blocks along Madhya Marg are four storied, those along Jan Marg are higher having six storeys. Incremental development of the complexes and subdivision of these plots was permitted within the architectural control. The architectural controls evolved on the basis of an economical structural grid, of 1 7 ′ - 3 ′ ′ c/c in most of the cases, the same was repeated to carve 2 bays or 3 bays site as per the requirements and optimum use of the space. In the case of SCFs in Phase-I sectors, the grids were of a smaller size, keeping in view the economic limitations and requirement for smaller size of neighbourhood shops.
City Centre: Sector-17
Sector 17 designed as City-Centre of the city has cross-axial layout and rigid architectural controls. Various restrictions have been imposed on design elements like size and grid of columns, height of buildings, width and height of passages, size of show-windows and glazing, placement of core, ducts and staircases etc. Use of materials and system of construction to the extent of shuttering pattern has also been specified in Architectural Control Sheets of the City Centre. The material used for buildings is mainly concrete; brick having been used at some places. The urban form of the City Centre is an extended view of RCC structures which creates a sense of order. Depending on the façade controls, the buildings in the City-Centre can be divided into following three types:
Exposed brick faced SCFs placed along V4 of the sector. A four storeyed structures planned on a grid of 11’-3”, with 3-bays constituting a single plot having a courtyard at the back and a service core for each plot. The ground floor generally consists of shops; first and second floor has either shop or offices. Third floor was designed as the accommodation for the essential staff of the commercial establishment. There is no basement in these blocks, but there is a provision for mezzanine floor. The façade of the building is straight and uniform with exposed brick work; and rectangular concrete columns in the public corridor. The upper floors have recessed balconies on both the facades.
Exposed concrete SCOs and other public buildings. Four storied structures planned on a RCC framed structural grid of 17’-3”x17’-3” to accommodate large showrooms and departmental stores. The controls permit a combination of two or more floors and also an additional floor provided that the external façade is not altered . On the first, second and third floors 6’-9” wide balcony has been made compulsory to provide shade from the summer sun, monsoon rains and inclement
weather. Repetitive use of concrete parapets on these balconies gives a specific architectural character to the City-Centre. A few public buildings like State Library, Gallery of Portraits, Estate Office, State Bank of India Building and Post & Telegraph Building are also built with slight variations within the framed façade. Undulatory modular glazing has been provided on upper floors.
* Schematic Design Controlled: Special type of buildings such as cinema halls and petrol stations etc. located in architecturally controlled area of the City Centre, Sub City Centre and along important avenues – Madhya Marg, Jan Marg etc. were subject to Schematic Design Control. The controls evolved out of the functional requirements that dictate the architectural character of the building and defines the outer form, skyline, volume whereas the internal planning is left to the discretion of the owner.
c) Frame controls
Frame controls were essentially evolved for row type attached houses on plots varying from 5 marla to 14 marla category. Prior to the evolution of frame controls, the houses were designed keeping in view general building byelaws and zoning restrictions. Since the experiment of developing small plots attached to each other and sharing common walls on both sides according to zoning guidelines resulted in a haphazard street picture, the need for frame controls was felt. Frame control design comprises of fixing the extent and heights of the party walls and a top course and connecting them with a frame. The building portion which can be of any design stays behind this frame. Initially, the frame controls provide standard sizes of doors and windows which could be chosen and used in any manner. Further, the size and percentage of fenestrations on facades were also fixed. However, these stringent controls were relaxed subsequently allowing flexibility in the size and shape of the doors and windows.
There are separate frame controls for marla houses in both the phases of Chandigarh. The frame controls in phase I sectors provide for incremental construction in 3 phases up to a maximum height of 32’-3”, wherein the final built form is cuboid in volume with equal areas on all floors. The frame controls in phase II sectors mandated compulsory stepped rear terraces, each provided with brick screen walls for outdoor sleeping. The maximum height of these houses is 3 2 ′ - 3 ′ ′
However, later, the above mentioned maximum height relaxation upto 3 3 ′ - 0 ′ ′ and coverage of compulsory rear open terraces was also made allowed. But, presently, the above mentioned category of houses is being governed by the Zoning Parameters vide notifications dated 16.10.2008. The description of the same is mentioned in annexure..
d) Architectural Control Houses/Building Height Restrictions:- Architectural Control Houses are located in Ph-I Sectors along Uttar Marg, Leisure Valley and certain V3 roads. These controls restricted only the footprint, volume and the height of the house. The height of these houses was restricted to double storey in most of the cases to provide unhindered view of the distant Shivalik hills from the northern sectors, where most of the architectural controls houses are located. However, the said height restriction has also been relaxed vide notification dated 16.10.2008. In some of the phase-1 sectors i.e. 4, 5, 11, 19, 20, 27, 28 of Chandigarh, the building height controls were applicable with the maximum height of 2 4 ′ - 0 ′ ′ and 2 5 ′ - 6 ′ ′ respectively with the maximum number of storeyes two. The said controls were later replaced by the provisions of Zoning Plans, which are applicable presently also. The description of the same is mentioned in annexure.
e) Controls in City Centre & Sub City Centre
Sub City Centre Sector 34
Although the architectural control of Sector 34 differs in detailing from that of Sec-17, but there is similarity of expression due to use of RCC and the modular structural grid adopted.
f) Gates and boundary wall: All gates and boundary walls are also to conform to standard designs in order to ensure a uniform street picture. Initially the front boundary wall of attached as well as detached / semi detached houses was 2’-5½” high but subsequently however the same was increased to 3’-8 ½” height. Further, the provisions regarding locations and number of gates have also been relaxed by Chandigarh Administration. The description of the same is mentioned in annexure.
New Additional Norms / Regulations for Areas
The norms, which are not covered in the existing norms already notified by the Chandigarh Administration and norms for the activities which have been freshly proposed in this Master Plan have also been finalized on the basis of the proposals given in the Master Plan as well as the recommendations of Master Plan Committee, which are as follows:-
a) Residential
i) Permissibility of landuses in proposed residential pockets:-
The social, educational and cultural facilities like school, community centre, religious buildings, parks, open spaces and other public facilities as provided in various sectors in Chandigarh shall compulsorily be provided in the proposed residential areas/pockets in Chandigarh.
Servant Quarters in Residences
The servant quarters in the houses having area of 1 Kanal and above has been made mandatory.
Development Controls/norms for buildings in Manimajra
The norms as prescribed by the Municipal Corporation, Chandigarh shall be applicable to the area falling within the limits of planning area of the Chandigarh Master Plan 2031, Manimajra, except the following areas, where the norms mentioned in their Zoning Plans/approved drawings shall be applicable:
Pocket 1 (commercial),
Pocket 6 (Motor Market and Commercial Complex),
61.21 acre residential-cum-commercial scheme on the east of Chandigarh – Kalka Road,
Group Housing in Pocket 2 & 3,
Modern Housing Complex in Pocket 4 & 5 and
Rehabilitation colonies developed by Chandigarh Administration.
On other Group Housing, Commercial, Government and semi government norms as approved by the Chandigarh Administration shall be applicable.
Development controls for abadi deh of Village falling in the limits of U.T., Chandigarh
The notified Rural Bye-laws of Chandigarh Administration shall be applicable on areas falling in abadi-deh/phirnis of the villages and areas proposed for expansion of various villages.
i)The draft of said notification has been submitted for approval before finalization of the same, the detail of the same is as given below:
Initially, the Chandigarh Administration(Erection & Re-erection of building) Rules, 2006 for the villages in the Municipal area of Municipal Corporation of Chandigarh were notified under Sub-Section 2 of the Section 5 (2) read with Section 22 of the Capital of Punjab (Development & Regulation) Act, 1952 vide Notification No.26/6/39/UTFI(3)-2006/7869 dated 27.12.2006.
The provisions of above mentioned notifications were found to have many limitations like limited definitions, not defining elaborated procedure for sanctioning of building plans, not having provisions for the private developers, energy conservation etc. and with limited volumetric controls having only details of site coverage only some categories of plots.
These rules were also deliberated under the Chairmanship of AA, UT on 21.12.2010 and accordingly the same were drafted by the Department Of Urban Planning, UT, Chandigarh. The feedback has been received from EO, UT, Additional Commissioner, MC and Director Rural Development and Panchayat and the same has been incorporated in the draft Rural Building Byelaws. The provisions of draft rules have been made with the following considerations:
Exhaustive definitions given.
Detailed provision given w.r.t. contents of the submission drawings - the site plan, floor plans, sections and elevations.
Plan Approval Committee is defined.
Provision of 60 days to approve the plans.
Provision made for revalidation of building plans with prescribed fee as applicable.
Provision made to give at least one week notice before erection or re-erection. Provision also made for DPC.
Provision made for partial occupation.
In addition to width minimum riser/tread for residential as well as commercial buildings defined.
Provision made for Rain Water Harvesting & Solar Water Heating System.
No provision for private developers.
Maximum permissible height.
Site coverage of commercial and institutional buildings has been defined.
Siting norms for commercial, social facilities like school, community hall, dispensaries have also been defined.
The guidelines for earthquake safe construction have been defined on the basis of the Model Rules forwarded by Government of India.
The parameters of volumetric controls of the residential building have been elaborately defined as below:
Plot size (in Sq.Yrds)
Ground Coverage
FAR
Set back
Upto 100
70%
2
5'
101-250
70%
2
10'
251-500
70%
2
10'
501-1000
50%
1.5
15'
Above 1001
separate zoning
b) Institutional
IT Park, Phase-III**:- For the site for IT Park, Phase-III as earmarked in the Master Plan, if decided to be developed for the said purpose by the Hon’ble Court as the matter is sub judicious, the norms shall be as follows:-
Volumetric Controls:- The following norms shall be applicable on the IT Park, Phase-III, Chandigarh:-
Sr.No.
Parameters
Norms
1
MaximumPlotDensity
25unitsperacre
2
FSI
1.00
3
Groundcoverage
40%
4
Height
36'-0"
5
Othernorm
Low density with lush green
(*As decided in the 51st Master Plan Committee meeting held on 17.8.2011) (**As decided in the 53rd Master Plan Committee meeting held on 6.9.2011)
Institutional Area: Sarangpur
In the institutional pockets in Sarangpur (except Educity), in village Dhanas and near Manimajra shall be developed with low density and low rise buildings with the following parameters:-
Sr.No.
Parameters
Norms
1.
Maximum Groundcoverage
20%
2.
MaximumFAR
0.5
3.
MaximumHeight
36'-0"
4.
Maximum No. of storey
3
5.
Parkingnorms
4 ECS for 100 sq. mt. of covered area.Surfaceparking-Minimum20%ofthesitearea.
c) Environment
The norms related to various environmental factors related to Chandigarh have been finalized by the Master Plan Committee and in the proposal part of Master Plan, which are given as below:-
i) Green buffer/ strips
The specified width of plantation as green buffer/strip shall be developed along various features/ landuse as described below:
Sr. no
Feature/area
Width of green buffer/ strip in meters
Condition
1.
Patiala-ki-Rao,Sukhna Choe and Natural choe
100
Shall be declared as Eco sensitivezone.
2.
Interstate border of Chandigarh with PunjabandHaryana
100
Wherever non compatible landuse exist on other side of interstateborder.
3.
Along roads (on eitherside)
30
To give the feel of gardencityChandigarh.
4.
Railway Line (on eitherside)
30
Note:- The owner of sites, wherein the above areas are falling shall be liable to maintain the specified width of buffer strip.
ii) Open Spaces:
No further construction of community facilities in the planned open spaces is permitted which interfere with pedestrian movement, availability of green spaces and natural drainage.
Large campuses like PGI, Panjab University, CSIO, IMTECH and housing societies shall be encouraged to improve their water, energy and resources use efficiencies and introduce waste water recycling.
iii) Securing the Lake’s Catchment and Wildlife Sanctuary:-
The entire catchment of Sukhna Lake must be protected from any activities that may threaten the lake’s lifespan.
No development in the immediate vicinity of the Wildlife Sanctuary should contravene the objectives of the Wildlife conservation.
iv) Eco sensitive Zone:
Chandigarh Administration has constituted a Committee to determine the extent of Eco-Sensitive Zone to be declared around the Sukhna Wildlife Sanctuary and the recommendations of the Committee shall be applicable accordingly. The norms shall be made applicable after approval of the competent authority.
d) Traffic transportation
Metro Act:- Provision of Metro Act to be adopted by the Chandigarh Administration shall be followed.
e) Telecommunication
Provision of Mobile Tower Policy:-
Installation of Mobile Towers shall only be allowed as per the provisions of notified Mobile Tower Policy by the Chandigarh Administration.
Earlier, Chandigarh Administration issued two policies/guidelines regarding installations of Mobile Towers in Chandigarh, one in 2004 and another in 2008. The features of these policies have been mainly procedural and similar to the Building Byelaws. Mainly the security and structural safety aspect of the buildings has been handled in the policy.
As per 2008 Policy, these towers are allowed only on non-residential buildings in UT, Chandigarh. The mobile tower operators are required to seek prior permission from Chandigarh Administration before installing the tower. Since, in several parts of UT, Chandigarh adequate number of non-residential buildings are not available, large number of towers have come up on residential buildings in village area is supervised by the Municipal Corporation and some of them have come up in the developed sectoral grid area of Chandigarh. Hon’ble Punjab & Haryana High Court and even in the Hon’ble Supreme Court of India.
While formulating the new Mobile Tower Policy, the polices/guidelines of the year 2004 and year 2008 and representation of the mobile operators, in addition to the related norms of all the concerned departments/organizations have been taken into account. In the new policy, for the interest of providing seamless uninterrupted mobile services which has become an essential service for any citizen, the area where adequate number of non-residential buildings are not available, it has been proposed that a small Micro Cell based pole be allowed on residential buildings also to provide continuous network availability.
All the telecom operators are directed to get the EMF level checked from some third party at regular intervals for compliance of these guidelines. The applications for the same shall be submitted to the Estate Office of UT, Chandigarh and Commissioner, Municipal Corporation for their respective areas, which they are mandated to implement the building byelaws. If any applicant is not satisfied with the orders of the Estate officer/Commissioner, MC, then the concerned applicant can file an appeal before the Finance Secretary-cum-Chief Administrator, UT, Chandigarh in this regard. Further, the action regarding unauthorized Mobile towers shall be taken by the above mentioned organizations in their jurisdiction area.
The draft Mobile Tower Policy has already been notified by the Chandigarh Administration on 16/10/2012 for public objections/suggestions and the same is under consideration for publication of final policy.
f) Agriculture Zone:- For the activities, which have been made permissible in the agriculture pockets of the Chandigarh Master Plan proposal, the norms have been descriptively evaluated to control and regulate the unauthorized and haphazard development within these pockets.
h) Powers for Development of Areas in Chandigarh:- The proposed Residential, Commercial, Industrial, Transportation or public facility areas in Chandigarh Master Plan 2031 are reserved for development by the Chandigarh Administration or its undertakings/public authority, as per detailed Scheme Plan and Zoning Regulations as approved by the Chandigarh Administration.
i) Already approved projects
For the projects which have already been approved by Chandigarh Administration, the norms already approved for the same shall be applicable there upon.
Violations of Rule 5/Compoundable Items:-
i) As per the Punjab Capital (Development and Regulation) Building Rules, 1952 if any change/alteration made by the owner at site during the course of construction these changes are permitted by paying the requisite fee under the provision of Rule 5 of above said Rule.
ii) The essential services required for the buildings such as over head water tanks, brick jalli, headway under staircase etc. made compoundable by the Chandigarh Administration at the time of granting the occupation certificate/sewer connection.
iii) The penalties for not obtaining the DPC certificate and illegal sewer connection has also been imposed by the Chandigarh Administration.
The description of the same is mentioned in annexure.
Need based changes in architectural controls
In Residential Buildings:
The unprecedented and unforeseen growth of population of the city, their growing affluence and changing lifestyles. The emergence of the town as a major trading and service provider city in the present liberalized socio economic scenario have exerted , tremendous pressure on the city’s vital infrastructure and the order of the built environment. Illegal construction through additional floors, coverage of balconies and courtyards which are essential for light and ventilation, construction beyond zoned areas, violation of frame controls are some of the major violations being witnessed. Taking cognizance of the situation, Chandigarh Administration has been undertaking periodic review to provide need based relief and address the genuine problems of the citizens.
In Commercial Buildings:
Chandigarh Administration has undertaken gradual and periodical review of various architectural controls to provide for more space. At the same time, an endeavour has been made to retain the architectural facades or make minimal external changes so that the street picture is preserved.
H Permissibility for various activities in Residential premises:
The following activates/services shall be allowed in the residential premises, subject to the fulfilment of certain conditions as described below:-
Sr.No.
Usespermissible
Permissibleareaforactivities
Other conditions
1.
Professional services (Doctors, Advocates, Architectsetc.)
25% of the covered area to the maximum extent of 50 sq. m, whicheverisless.
AfterpriorapprovalofChandigarhAdministration Provision of the Chandigarh Advertisement Control order, 1954 as amended fromtimetotime,shallbestrictlyobserved.Payments/chargesasprescribedbytheChandigarhAdministration.
2.
NursingHomes
i) Theminimumsizeofresidentialpremisesshallbeequalto500sq.yds. ii) Permission shall be granted only to those Nursing Homes functioning in the Residential Premises on the date of issue ofthe orders No. 31/1/294-UTFI(4)- 2002/4522Dated14.7.2003 iii) Suchbuildingshouldhaveaparkingspaceforvehiclesequaltothenumberof indoorbedsplustwo. iv) If there are indoor beds there must be a parking space for atleast five cars/jeeps. v) Thesaidparkingspace,maybeinsideandoutsideofthebuildingorboth. vi) The parkingspaceoutsidethe buildingwill be publicparking space, which will be maintained by the Municipal Corporation will be at liberty to charge fees fromthosewhoparktheirvehiclesthereupon. vii) The fulfilment of other provisions of orders No. 31/1/294-UTFI(4)-2002/4522 Dated 14.7.2003 of Finance Department, Chandigarh Administration shall be mandatory.
Sr.No.
Usespermissible
Permissible area for activities
Other conditions
3.
Crèche
A portion of a residential building upto the maximum of50 sq.mtrs. or 25%ofthe covered area, whichever is less.
ShallbepermissiblewiththepriorapprovaloftheChandigarhAdministration. Shall also be subject to the fulfilment of conditions of notification dated 21.2.2003, subject to the approval by Department of Urban Planning, Chandigarh Administration.
4.
PayingGuest
The minimum usable area foronePayingGuest
i) Shall be 50 sq. m. shall be with adequate provisions of toilet as per norms of Public HealthDepartmenti.e.oneWCforfivepersons. ii) The area of the house for Paying Guest Accommodation shall not be less than (7½) marlaandpartofitshallbeusedbytheownerhimself/herself. iii) The Paying Guest Accommodation shall be permitted only in those residential properties, which are sanctioned as per building byelaws, and no unauthorized constructionhastakenplaceafterthegrantofcompletioncertificate. iv) Noextras/newkitchenshallbeerectedbeyondtheapprovedbuildingplans. v) Vehicleshouldbeparkedwithinthehousepremisesasfaraspossible. vi) Fulfilmentoftheconditionsofnotificationdated16-11-2006.
5.
STD/PCO (Installation of a STD, PCO, Fax or Photostat machine).
Maximum of 15 sq. m or 20% of the residential area of the building, whichever is less.
i) Onlyapartofthesanctionedbuildingcanbeusedforsuchapurposeandnoexternal structuresshallbeinstalled. ii) Only the sign boards approved by the Chief Architect, U.T. Chandigarh as per standarddesignshallbepermittedtobeinstalled. iii) Noexternalchangesinthebuildingshallbeallowed. iv) Fulfilmentofconditionsofnotificationdated 19.6.1998.
Servant quarters: The servant quarters in the residential premises shall be provided, subject to the following conditions:-
Sr. No.
Parameter
Norms
1.
Condition of minimum sizeofplot
Owners of plots above 420 sqm. and above shall make provision of servant quarters for domesticservants.
2.
Permissible areas
Shall be permissible within the zoned area of the house as specified in the respective zoning plan.
3.
Proportion with dwelling units
Minimum one servant room for one dwelling unit.
4.
Constructio narea
If a servant room is built on ground floor, it shall have separate courtyard of not less than 10 sq. m. but shall be within the maximum permissiblecoveredarea.
5.
Provision of kitchen with servant quarter
Kitchenette shall be allowed alongwith servant quarters.
6.
Provision of water closet and bathroom
Separate servant room not built as part of the main house shall have a water closetandbathroomattachedthereto.
J General norms of Residential
Minimum size of habitable rooms:- The parameters regarding size of habitable rooms shall be as follows:
Sr. No.
Parameters
Norms
1.
Minimumsizeofahabitableroom excludingakitchen
9.3 m floor space
2.
Minimum width of a habitable room
2.2 m.
Note: Subject to the fulfilment of norms of Chandigarh Administration related to light and ventilation
Provision of Kitchen: The provision of kitchen in the residential premises shall be made as mentioned below:-
Sr.No.
Typeoffloor/unit
Maximum no. of kitchensperfloor
1.
On the residential plots of less than250sq.yds.
1
2.
On the residential plots of 250 sq.yds.ormoreinarea.
1
3.
Intheduplexdesignhouses
1
4.
Minimumsizeofthekitchen
4.5 sq. m.
5.
Minimumwidthofkitchen
1.5 m.
6.
Minimumheight
2.7 m.
Lobby, Corridor, Passage or Balcony:- The minimum width of any lobby, corridor, passage or a balcony in a residential building shall be as given below:-
Sr.No.
No.ofusers
Minimum width in m.
1.
Upto 10
0.9
2.
11 to 20
1.1
3.
21-100
1.25
4.
For every additional 15persons
Increase 25 cms. with a maximum of 2.5m.
Existing Development Norms
1 . Residential: Development Controls applicable on various types of residential houses as per notification dated 16/10/2008 are as given below:
(A) Plotted Housing in Sectoral Grid in Chandigarh: Volumetric controls for plotted houses in sectoral grid are as below:-
Sr.No.
Type of houses
Maximum Ground coverage w.r.t. total plot area
Maximum * FAR
Height
1.
Marla houses of less than one Kanal governed by frame control / architecturalcontrol.
65% (in main building zone) + 5% (rear court yard)=(70%)
2.0
i) Phase-I: 31'-6" (without additional coverage) and 33'-0" (with additional) coverage. Heightequivalenttoground floorheight. ii) Phase-II:32'-3" iii) The design of boundary walls of various sites shall be applicable as per the standard design available in the DepartmentofUrbanPlanning.,UT. In marla type houses a railing of 2'-3" high shall be allowed on the front boundarywall.
2.
One Kanal and above but lessthantwoKanals
50%
1.5
i) Phase-I:35'-0",ancillaryzone:24'-9" ii) Phase-II-33'-0"ancillaryzone:24'-9" iii) Further height uptu 3.0 mt. ( except marla houses) shall be allowed for services for services like water tank, solar system, air cooling tower. Gen set & screen wall to enclose services etc.
3.
TwoKanals
45%
1.25
4.
AbovetwoKanals
35%
1.0
Note*: The parameters prescribed in the above table shall be applicable on those sites for which additional coverage is being sought. However, for sites without additional coverage, the norms of Chandigarh Administration prevailing before 16.10.2008 shall be applicable and Architectural Control/Frame Controls and Zoning Plans shall be continued to be applicable on the sites being governed by the same.
B .Group Housing Scheme in Sectoral Grid:- Volumetric Controls applicable on Group Housing Schemes in the sectoral grid of Chandigarh.
Sr. no.
Parameter
Norms
1.
Minimumareaofsite
1 acre
2
MaximumGroundcoverage
40% of plot area.
3
MaximumFAR*
1.2
4
MaximumHeight
46'-9"inclusiveofparapetof3'-9"
5
MaximumNo.ofStoreys
4 Nos.
6
Boundarywalls
Specification and design as shown in Drawing Number 1 & 2, Job No. 2507, preparedbyDepartmentofUrbanPlanning,U.T.Chandigarh.
7
Parking
Total parking space equivalent to atleast 30% accumulated floor area of dwelling units.
8
Densityofdwellingunits
Category A B C
Density(unitsperacre)253545
9
Category wise area of dwellingunits
Category A B C
Areainsq.ft.1400-15001000-1075800-835
10
Communityfacilities
Floorareaupto2.5%oftheareaofthesite.
11
OrganizedgreenParks
a) 15%oftotalsitearea. b) Minimumsize600sq.yds. c) Widthnotlessthan45'-0".
12
Services
i) Height uptu 3.0 mt. shall be allowed for services for services like water tank, solar system, air cooling tower. Gen set 7 & screen wall to enclose
Note*: In the case of Group Co-operative House Building Societies Schemes, area under stilts with height of 7’-6” from floor to the soffit of the beam shall be permitted for parking which shall not be counted towards FAR, subject to the condition that this additional area shall not be sub divided/enclosed and utilized for increasing the number/area of the dwelling units.
C. Integrated Residential Housing Scheme outside the sectoral grid:- The following volumetric controls shall be applicable for all integrated residential houses schemes outside Sectoral Grid of Chandigarh:
Sr. no.
Parameter
Norms
1.
DefinitionofIntegratedHousing
Campus having population of 6250 persons approximately (4.5 persons per dwellingunit)shallbetermedasIntegratedHousing.
2.
Minimumarearequirement
25 acre
3.
MaximumGroundcoverage
40% of plot area.
4.
MaximumFAR
2.0
5.
MaximumHeight
62'-3" upto top of the parapetexcept any exemption granted by Chandigarh Administration specifically.
6.
MaximumlimitsofCommercialarea
For commercial area, permissible ground coverage shall be 30% of the total plot area, FAR 2 and height upto 62'-3" upto parapet level. Upto 2.5% of the entire area of the site can be allowed for commercial use to meet day to day requirementsoftheresidentslivingintheintegratedscheme.
D. Cheap Houses:- The norms applicable on the Cheap Houses, wherever proposed in the sectoral grid of Chandigarh, shall be as described below:
Sr.No.
Parameter
Norm/permissible
1.
MaximumGroundCoverage
75%ofplotarea
2.
MaximumCoverageon1<sup>st</sup>floor
Equivalenttothecoveredareaongroundfloor.
3.
Coverageof2<sup>nd</sup>floor
Notpermitted.
Note: The above permission shall be subject to the following conditions:-
I. That existing sewer lines are not coming below the building portion.
II. Payment of composition fee as fixed by the Chandigarh Administration.
III. Structural stability of the existing structure to be certified by a qualified structural engineer
IV. The construction of such houses shall be governed by the Architectural Control Sheets available in the Department of Urban Planning, U.T. Chandigarh
E. Rehabilitation Colonies:- In addition to the norms approved in the plans prepared /got approved by Chandigarh Housing Board or Chandigarh Administration, the following norms shall be applicable to all rehabilitation colonies under the control/supervision of Chandigarh Administration, Municipal Corporation, Chandigarh and Chandigarh Housing Board:-
Sr. No.
Parameters
Norms
Conditions
1.
Maximumnumberofstoreys
G+3 or as approved by Chandigarh Administrationfromcasetocasebasis.
i) Subjecttotheconditionthatthebuildingplans shall be got approved from PAC (Upper) on casetocasebasisandcanbeconstructedwith the prior approval after assessing the structuralsafetyoftheexistingstructure. ii) If the existing structure does not permit additional floor capacity, then the revised building plans have to be got sanctioned from competent authority and the structure with sufficient load bearing capacity for the structural safety and accordingly construction canbecarriedout.
In the houses constructed/ developed by Chandigarh Housing Board, Chandigarh as flats independent houses, duplex flats and other schemes, the relaxation/ amendments shall be allowed as per the provisionsoftheordersdated23.3.2010.
F. Development Controls/norms for buildings in Manimajra:- The norms as prescribed by the Municipal Corporation, Chandigarh shall be applicable on the area falling within the limits of planning area of Master Plan, Manimajra, except the following areas, where the norms mentioned in their Zoning Plans/approved drawings shall be applicable:
i) Pocket No. 1 (commercial),
ii) Pocket No. 6 (Motor Market and Commercial Complex),
iii) 61.21 acre residential-cum-commercial scheme on the east of Chandigarh – Kalka road,
iv) Group Housing in Pocket No. 2 & 3,
v) Modern Housing Complex in Pocket No. 4 & 5 and
vi) Rehabilitation colonies developed by Chandigarh Administration.
vii) On other Group Housing, Commercial, Government and semi government norms as approved by the Chandigarh Administration shall be applicable.
G. Development controls of Villages: The notified Rural Bye-laws of Chandigarh Administration shall be applicable on area falling in Abadi-deh/phirnis of the villages and areas proposed for expansion of various villages falling in the limits of U.T., Chandigarh.
i) The draft of said notification has been submitted for approval before finalization of the same, the detail of the same is as given below:
Initially, the Chandigarh Administration(Erection & Reerection of building) Rules, 2006 for the villages in the Municipal area of Municipal Corporation of Chandigarh were notified under Sub-Section 2 of the Section 5 (2) read with Section 22 of the Capital of Punjab (Development & Regulation) Act, 1952 vide Notification No.26/6/39/UTFI(3)- 2006/7869 dated 27.12.2006.
The provisions of above mentioned notifications were found to have many limitations like limited definitions, not defining elaborated procedure for sanctioning of building plans, not having provisions for the private developers, energy conservation etc. and with limited volumetric controls having only details of site coverage only some categories of plots.
These rules were also deliberated under the Chairmanship of AA, UT on 21.12.2010 and accordingly the same were drafted by the Department Of Urban Planning
The feedback has been received from EO, UT, Additional Commissioner, MC and Director Rural Development and Panchayat and the same has been incorporated in the draft Rural Building Byelaws.
The provisions of draft rules are have been made with the following considerations:
a. Exhaustive definitions given.
b. Detailed provision given w.r.t. contents of the submission drawings - the site plan, floor plans, sections and elevations.
c. Plan Approval Committee is defined.
d. Provision of 60 days to approve the plans.
e. Provision made for revalidation of building plans with prescribed fee as applicable.
f. Provision made to give at least one week notice before erection or re-erection. Provision also made for DPC.
g. Provision made for partial occupation.
h. In addition to width minimum riser/tread for residential as well as commercial buildings defined.
i. Provision made for Rain Water Harvesting & Solar Water Heating System.
j. No provision for private developers.
k. The parameters of volumetric controls of the residential building have been elaborately defined as below:
Plot size (in Sq.Yrds)
Ground Coverage
FAR
Set-back
Upto 100
70%
2
5'
101-250
70%
2
10'
251-500
70%
2
10'
501-1000Above 1001
50%separate zoning
1.5
15'
l. Site coverage of commercial and institutional buildings has been defined.
m. Citing norms for social facilities like school, community hall, dispensaries have also been defined.
n. The guidelines for earthquake safe construction have been defined on the basis of the Model Rules forwarded by Government of India.
Doors and Window:
There shall be no restriction on having only square and rectangular shaped doors and windows in residential buildings.
Staircase:-
In Residential building, single family or two families residential buildings:- The norms for residential building, single family or two families as below:-
Sr.No.
Parameters
Norms
1.
Requirement of staircases
Every residential building more than one storey high shall be provided with atleast onestaircase
2.
Minimum width of staircase
85 cms.
3.
Maximum number of risers in one flight
15
4.
Minimum heightofrisers
19 cms.
5.
Minimum widthoftread
25 cms.
In Residential buildings for more than two families:- Every residential building for more than two families shall be provided with atleast one staircase extending from ground floor level to be highest floor having minimum clear width.
The following width in accordance with the following table:-
Sr. No.
No. of users
Minimum clear width
1.
Numberofusersupto10
0.85cm.
2.
Numberofusersupto11to20
1.10 m.
3.
Numberofusersfrom21to100
1.25 m.
4.
Increase 1" (2.5 cms) for every additional 15 persons until a maximumof2.75mtrs.isreached.
Note:-The staircases shall be constructed of fire resisting materials.
Winders and treads in staircases in residential buildings:- In residential building, winders in staircases shall be allowed as follows:-
Sr.No.
Parameters
Norms
1.
Maximum number of risers in winder
2
2.
Maximum number of treads in winder
3
3.
Maximum reduction in width of staircase
3"
Note: Subject to the following conditions:-
Fire safety norms
Payment of composition fees
Boundary Wall:-
Front Boundary wall:- The maximum height of the boundary wall shall be allowed as mentioned in the respective zoning plan, subject to the maximum of 3’-8 ½” (type-B).
Rear boundary wall:- The height of the boundary wall along rear boundary and along the portion of boundary which divides it from other sites in the rear and long side boundary wall form the front building line upto the rear boundary shall be allowed upto 5’-11½” in the side of all category of residential plots.
In case of marla/kanal type plot which are covered under frame controls, rear courtyards are already surrounded by 5’-11 ½” high boundary wall.
Glazing:-
Provision of openable glazing in a sanctioned verandah in residential buildings shall be compoundable on the prescribed payment.
The glazing or sliding grills in verandahs of a standard door opening and a window, which is not smaller than 1.2 m x 1.2 m (4’x4’) for proper light and ventilation shall be allowed in marla houses.
• Brick Jali:-
The brick jali of any design shall be permitted to the residential houses governed by the frame controls, subject to the condition that no solid wall shall be constructed in any part of the jali as prescribed in the frame control.
The jali shall not violate the building lines prescribed in the frame controls.
Brick jali at terrace of the houses in the second phase sectors, constructed upto the height of the frame line shall be allowed.
Railing:
Railing of any type and design shall be allowed in houses governed by frame control upto 2’-3” high on front boundary wall.
Nitches:
Nitches is the common wall shall be allowed with the consent of the owners.
In case where one owner has already constructed nitches and the occupation certificate has been obtained, the owner of the adjoining house shall be allowed to have the nitches in the common wall even without the consent of that house owner.
Garage:-
Where a garage adjoins a habitable room there shall be no opening in the common wall. However, a door connecting the garage with the main house shall be permitted.
Gates and Gate Pillars:-
In the residential houses the gate of the standard design and any of the standard width as shown on standard Drg. No. S-1/S-5, shall be permitted along the side boundary wall abutting on the accessible street/road. No gate shall be allowed on V-3 roads, public open space, reserved space etc.
The height of gates and gate pillars in residential buildings shall be allowed upto a maximum height of 5’-11 ½” .
There shall be no change in the width of gate pillars from that shown in the standard design.
To facilitate parking and movement of vehicles, two gates shall be permitted along the accessible road in the front boundary wall of the residential buildings in Chandigarh.
Parking:-
As regards to residential buildings, all buildings located on site of one kanal or above shall have parking facilities equivalent to 1 ECS per floor of the building and further subject to the condition that adequate parking is planned to ensure that no vehicle of the owner/occupier of any such building is parked outside the premises.
Building Material:-
Different types of building materials shall be permitted in the houses governed by the frame controls.
Car parking/porch covered with A.C. sheets or fiber glass roof shall be permitted in the front courtyard of the residential houses.
Walls and roofs of all the buildings shall be of fire resisting materials.
Underground water tank:-
Underground water tank shall be permitted in the rear courtyard of the residential buildings.
It shall be 4’-0” away from the common walls of the site.
It shall be constructed as per the satisfaction of public health U.T./ MC.
Minimum height of room, verandah etc.:-
Sr.No.
Type of room/verandah
Norms
1.
Minimum height of habitable room from the surface of the floor to the lowest point of thefinishedceiling.
2.75 m (9'-0").
2.
Minimum height of habitable room from the surface of the floor to the underside of the joists, beams or rafters , if joists, beams or rafters are provided.
2.29 mtrs. (7'-6")
3.
Airconditionedrooms
2.42 m (8') measured from the surface of the floor to the lowest point of the air conditioningductorthefalse ceiling.
4.
Minimum height of a water closet, bath room, a store, a gallery, a verandah and mezzaninefloor.
2.29 mtrs. (7'-6").
Minimum area of the courtyard:- (a) Interior open space for light and ventilation, the whole or part of one side or one more room intended for human habitation and not abutting on either the front, rear or side open space shall abut on an interior open space whose minimum width in all directions shall be as per table below:
Sr. No.
Height of the building upto inMeters.
Interior open space to be left out on all site (front rear and sides in eachplotinMeters.)
1.
10
3
2.
15
5
3.
18
6
4.
21
7
5.
24
8
6.
27
9
7.
30
10
Note:
No projection shall be allowed within the maximum width of the courtyard in any direction as mentioned in the table above.
The Chief Administrator may permit ‘Pergola’ in the buildings if light and ventilation of the building is not affected due to pergola.
The table shall also be applicable in case of exterior open spaces permitted within the zoning regulations.
Coffers/Pergola:- Coffers/Pergola upto 9” below RCC slab of the projection at first and second floor level shall be allowed in Frame Control Marla houses provided it is sanctioned in the building plans.
Projection/Cantilever:- the provisions of projection/cantilever in residential building shall be made as follows:-
Sr. No.
Area of construction/cantilever
Norms
1.
First and second floor of all marla houses and one kanal houses governed by Frame Control/Architecturalcontrol
Maximum upto 0.91 m. (3'-0") from the building line in the front and rear courtyard and at least 3' away from either side of the building line from the center line of the common wall, subject to structural stability, shall also be allowed.
2.
In kanal type buildings governed by zoning plans in all sectors.
Maximum upto 6'-0" depth from the faceofthewall.
3.
On terrace level of all marla type houses
Notallowed.
Solar Water Heating System:-
As regards to residential buildings, all houses including the existing houses on a site of one kanal will make provisions for solar water heating system having capacity of atleast 100 ltrs. and on a site of two kanals and above that of atleast 200 ltrs.
COMMERCIAL:-
土
The norms applicable on various commercial sites/area in Chandigarh are given below:-
(A)General: The following norms shall be applicable on all the commercial plots/sites:-
(a)Volumetric Control:- Following volumetric controls/other norms are applicable on the commercial plots/sites in Chandigarh:-
Sr. No.
Parameters
Norms
Condition
1
Permissible uses
Equivalent or lower intensity of use within the same trade categorywithoutpaymentoffees.
-
2.
Subdivision
i.An additional entry with door shutter opening inside the shopshallbeprovided. ii.An additional door in the rear side ofthe buildingof same width height and design as that ofthe existing door will be allowed. iii.The party wall between the two sub divided shops can be constructeduptoceilingheight.
Ventilation for the basement floor inthe remaining partoftheglazingisnotdisturbed. Thesizeoftheadditionalentryshallbeofthesame sizeasthatofexistingentry. Asshowninarchitecturalcontrolsheets. The party wall shall be of any fire retardant material. Onthepaymentofprescribedfees.
3.
Depression in groundfloor
1.21 m.
Structuralstabilityatsite
4.
Provision of Mezzanine floor
Allowed
Provision of minimum permissible height in conformitywithbuildingrules
5.
Provision of basement storey
Permitted
It shall not exceed the coverage as indicated in the ArchitecturalControlSheets.
6.
PrintingPress
Printing press business with modern computerized machinery and equipment shall be allowed in the commercialbuildings.
Onlyonthegroundfloor Provided that there is no structure borne and air bornenoiseandvibration The operation does not affect the structural safety ofthebuildings
Change of trade of Ground Floors of Commercial Buildings:-
The allottees/lessee of commercial sites/premises in Chandigarh can pursue any trade mentioned in the schedule II i.e. (A) New General Trade and (B) New Special Trade without applying for conversion of trade and without paying conversion fee subject to the following conditions:-
I. Migration to 7 trades as mentioned in (B) i.e. New Special Trade from other trade of Category (A) i.e. New General Trade shall be allowed without prior permission of the Chief Administrator and subject to the examination and clearance from the environmental, health and traffic considerations and further subject to the condition that hygiene and sanitation laws are not violated.
II. The conversion of trade will be applicable to the ground floor of all commercial sites/premises only.
III. The allottee/transferee/occupier will, however, give an intimation to the Estate Office, U.T. Chandigarh in writing about the trade being pursued by him.
Parking Requirements:- Parking requirements for the commercial sites shall be as below:-
Sr.No
Plotarea
Norms (ECS per 100 sq. mtrs.ofbuiltuparea.)
1.
2 kanals and upto one acre
2ECS
2.
1acreandaboveplots
4 ECS
* Urinals/Water Closet/Toilets:- Every commercial, warehousing and industrial buildings shall be provided with water closet in accordance with the requirements of the table given below:-
No. of persons working
Minimum number of waterclosets
Minimumnumberof urinalsorsinks
1 to 9
1
1
10 to 24
2
2
25 to 49
3
3
50 to 100
5
5
Over 100
One water closet for each additional 30 persons
Note:- Provision of toilets for specially challenged persons is mandatory as per the provisions of Chandigarh Administration.
Air Conditioners:- All the shop owners desirous of installing air conditioners in the verandah for their shops shall fix the same above the false ceiling in the verandah as follows:-
I. The false ceiling shall be of any material/specification of their choice subject to minimum clear height to be fixed by the Department of Urban Planning, UT, Chandigarh.
II. Every shop owner who is having shop without air conditioner on one or both sides shall have to close the suspended ceiling from the sides, as the case may be.
III. As approved by the Department of Urban Planning, UT, shall vary in each case depending upon the height of public corridor.
IV. The design of the false ceiling in public verandah shall be based on the guidelines issued by the Department of Urban Planning, UT, Chandigarh.
Lodging-cum-Restaurant sites:-
The norms applicable on Lodging-cum-Restaurant sites are as follows:-
Sr. No.
Parameters
Norms
Condition
1.
CoverageofCourtyard on 2<sup>nd</sup> floor in LCR sites
Allowed
Thecourtyardshallbecoveredwithtransparentpolycarbonateorfibresheetsinsuchamannerthatallowsinfreshair/ventilationfromthreesides.ThedesignofthesameshallbegotsanctionedthroughPlanApprovalCommittee (PAC)priortoconstructionatsite. The area covered with fibre sheets shall be used purely for the purpose ofcirculation at siteonlyandshallnotbeputtocommercialuseinanymanner.
2.
Conversion of basementstorey
compounded
PrescribedbytheChandigarhAdministration. TheareaofthebasementshallbecountedtowardsFAR. Thecompositionshallbefortheentireareaofbasement. Minimum of two staircases shall be constructed in the basement storey. Out of which one stair case shall be designed and constructed as a fire escape stair case and it must directly open to public corridor or in the public street in relaxation of the provisions of theArchitecturalControls. No kitchen tandoor or any other fire catching appliances shall be allowed in the basementfloor. ProperfiresafetyarrangementaspertheNationalBuildingCodeandasper Delhi FirePrevention andFire Safety Act, 1986, as extendedtoU.T. Chandigarhshall be made. The building material used in the construction of basement storey shall be strictly fire proof. Properarrangementshallbemadeforthedrainageofthesprinklerwaterforfirefighting purpose. No public health facilities such as toilets, water connection etc. shall be allowed in the basementstorey. The ventilation of the basement storey shall not exceed the area as shown on the ArchitecturalControls/zoningcontrolsandsanctionedbuildingplans.TheconstructionoftheHotelbuildingshallconformtothesanctionedbuildingplans.
Stand alone Marriage Palaces/Banquet halls specially earmarked:
Volumetric Controls:- The following shall be the volumetric control for construction of standalone Banquet Halls specifically earmarked in Chandigarh:-
Sr.no.
Parameters
Norms
1.
Minimum plot area
1 acre
2.
Maximum Ground coverage
40%
3.
Maximum FAR
. 80
4.
Maximum Height
36'-0"
5.
No. of storey
3
6.
Parking Requirement
For every acre of plot, a minimum of parking equivalent to 130 ECS.
Hotel sites:
Volumetric Controls:- The following shall be the volumetric control for construction of Hotel sites specifically earmarked in Chandigarh:-
Sr. No.
Parameters
Norms
1.
Max. Ground Coverage
35%
2.
Max.FAR
1.5
3.
Max.Height
60'-9" (18.52 mtrs.)
4.
Parking requirements
1 ECS for every 3 bed rooms in Hotel. For entire commercial area including restaurant, banquet, conference hall, commercial sites etc., 4 ECS per 100 sq. mtrs. of built up area under commercial use. For rest of the area, 2 ECS per 100 sq.mtrs.ofbuiltuparea
Approach road in newly proposed commercial area:
No commercial activities on roads entering in the city shall be allowed with direct approach. These roads shall have slip roads, commercial area is to be proposed here.
SCOs/SCFs: (i) The norms applicable specifically on SCOs/SCFs in Chandigarh shall be as follows:-
Theminimumsizeofroom,passageetc.shallnotbeviolated. Providedthegroundfloorofthebuildingisnotdepressed. However, if the ground floor is depressed after paying the prescribed charges,theheightofanyofthefloorsshallnotexceed13'-0".
Shall not be allowed to alter and the total covered area and the total numbers of floors shallremainsame
ProvidedthebasementheightanduseisasperArchitecturalControls. Payment of composition fee as prescribed by the Chandigarh Administration. Where the external façade of an entire row of SCO/SCFs is sought to bechangedbyamajorityoftransfereesinthatrow.
5.
Height of basement storey to be constructed in the city centrei.e.Sector17.
Maximum 3.66 mtrs.
6.
Structuralstability
Where adjoining SCO/SCF has already been constructed, independent structural arrangements shall have to be made by the owner so that the structure ofthe adjoining building isnotaffected
However,whereadjoiningSCO/SCFhasnotbeenconstructed,theownershallhaveto make a provision for supporting columns/beams/slabs for the adjoining structure at thelevelasindicatedintheArchitecturalControl.
7.
Courtyard
Shall be allowed on 1<sup>st</sup> and 2<sup>nd</sup> floor of the shop-cum-offices all over the city except the SCOs/SCF fallingin Manimajra,wherethere iscommonwallinrearside.
Furthersubjecttotheprescribedpayment. Payment of charges as fixed by the Chandigarh Administration from time to time. Conditionsanddirectionsregardinglightandventilation,minimumhabitable height, maintaining the external façade and overall heights and other mandatory conditions as per provisions of the Punjab Capital (Development andRegulation)BuildingRules,1952.
8.
Coverage of courtyard ofSCFsofSector35-C&D.
Coverageofcourtyardofsize 12'-0" x 20'-1½" on second floor of Shop-cum-Flats of Sector 35-C&D (internal V4 Market)shallbeallowed
PaymentofchargestobedecidedbytheChandigarhAdministration, Theownerhasconvertedhisshop-cum-officeaftercompletingdueformalities. Light and ventilation being provided as per the provisions of the Punjab Capital (DevelopmentAndRegulation)BuildingRules,1952.
Thisshallnotconstituteacourtyard,sinceitfallsoutsidethebuildingline. No coverage on first and subsequent floors shall be allowed on top of any terrace/roof,outsidethebuildingline.
10.
Staircase:
No bar henceforth on providing additional staircases in commercial buildings (including SCOs/SCFs)
To be used for habitable purpose in Showrooms, SCOs. SCFs, Bay Shops and similar buildings However, for fullheight partitions, priorapprovaloftheChiefAdministrator shallbe necessary.
14.
WideGlazing
Allowed only on 70% of surface area of brick jali/brickwall.
Any change in architectural control/frame control except the buildings identified as heritage buildings identified by the Heritage Committee formulated by Chandigarh Administration. All the owners/allottees/lessees/ occupiers in a row of a given block shall make a jointrequestforthispurposetomaintainthehomogenouscharacter.
Conversion of SCF to SCO:- Norms applicable on the SCF’s converted to SCO in Chandigarh are as given below:-
i. The upper floors of SCOs (including SCF's converted to SCOs under the rule) meant for office use shall be allowed. ii. Restaurant/ Dhabas is allowed in SCO
On payment of charges to be used for the more intensive purpose of shopping (display and sale of goods) and restaurants (sale and serving of prepared foods and beverages including banquet facilities) provided that suchuseisallowedunderthebuildingrules,byelawsandzoningplan. TotheconditionthatownerhasobtainedpermissionforconvertingtheSCF toSCO. Fulfilmentofconditions imposedbyChandigarhAdministration. On upper floors of commercial buildings (SCOs) which are designated as officespaceinarchitecturalcontrolsatpresent. Other conditions as stipulated in building rules and fire safety norms shall beprovidedwithintheexistingbuildinglines.
3.
Staircases
Allowed
In accordance with the prescribed architectural controls for shop-cum-Offices. Otherwise, the lessee may submit revised plans indicating the proposed position of the staircase and other internal changes. In such cases, the conversionshallcomeintoaffectonlyonsanctionoftherevisedplans.FloorareaofSCF/SCOisnotincreased. Where adjoining SCO/SCF has already been constructed, independent structural arrangements shall have to be made by the owner, so that the structureoftheadjoiningbuildingisnotaffected. The adjoining SCO/SCF has not been constructed, the owner shall have to made a provision for supporting columns/beams/slabs for the adjoin structureatthelevelasindicatedintheArchitecturalControl.
4.
Change of trade of Ground Floors of Commercial Buildings
i.Allowed in Industrial Area, Ph-I & II, Chandigarh. ii.ChangeoftradeofupperfloorsofSCOs andSCFs(convertedintoSCOs).
The conversion of trade will be applicable to the ground floor of all commercial sites/premisesonly.
Change of trade of upper floors of SCOs and SCFs (converted into SCOs):
a) InSector17,Sector34 V2andV3roads
I. For1<sup>st</sup>floor II. For2<sup>nd</sup>floor III. (For 3<sup>rd</sup>andhighfloors)
b) OtherlocationsinChandigarh
I. For1<sup>st</sup>floor II. For2<sup>nd</sup>floor III. (For3<sup>rd</sup>andhighfloors)
* Bay Shops:
Note:- Provided that such use is allowed under the Building Rules and Zoning Plans. However, permission for conversion of trade will have to be obtained, where necessary.
Sr. No.
Type of shops
Maximum number of Sub division
Size of sub shops
Condition
1.
Two bay shops in Sector 17 34'-6" x103'-0"
4
Any size (17'-3"x17'-3)
-
2.
Three bay shops
6
Any size (17'-3"x17'-3)
-
3.
MultiBay
-
Any size (17'-3"x17'-3)
In accordance with the Building Bye-laws. On payment of prescribed charges.
Urban Street Vendors:-
The provision of National Policy on Urban Street 2009 by Government of India, Ministry of Housing and Urban Poverty Alleviation shall be applicable on the various zones/street/roads identified/earmarked by the Department of Urban Planning, UT, Chandigarh and subject to approval of Chandigarh Heritage Conservation committee.
Other Norms :
Sr. No.
Parameters
Norms
Condition
1.
Cutout
Maximum size of 1 sqm. with a flap door on top of it alongwith the provision of cat-ladder
The approval of the Chief Administrator. The opening so created shall remain within the parapet height.
b) Integrated Implementation Of Sustainable Urban Drainage Systems (SUDS):
Techniques of Sustainable Drainage System (SUDS) like Pervious Paving, Green Roofs, Filter Drains, Filter Strips, Swales, Detention Basins & Retention Ponds, Infiltration Devices, Pipes and Accessories, Constructed Wetlands shall be compulsorily adopted for the following.
Sites with area lesser than 10,000 sqm. shall implement Rain Water Harvesting and SUDS Source control and Infiltration instruments such as green roofs, permeable paving, infiltration trenches, infiltration basins, etc.
Larger sites (area greater than 10000 sqm.) shall implement integrated SUDS techniques as feasible that would effectively reduce runoff.
Still larger sites (with area greater than 20 acres) should go for Soil Infiltration rate testing before implementing SUDS Infiltration devices & passive treatment techniques to enable successful implementation of “zero” storm water drainage from the site.
(C) Sewerage System
There shall be zero sewerage discharge into the nallah/choe/river.
FAB Technology should be used.
Large campus should have decentralized sewerage treatment plants.
Tertiary treated water should be used intensively.
(D) Solid waste management
All residences other than the apartments and small neighbourhood shops are required to store segregated waste (biodegradable and non-biodegradable) for collection by the Municipal Corporation
Group Housing Societies with more than 20 households and apartments with similar strength in each sub -sector shall provide segregated Solid Waste Management facilities within the site.
All commercial buildings shall have arrangement for storage of segregated waste
Medical organizations shall be bound to segregate and dispose off the biomedical waste as per the municipal guidelines.
The concerned organization shall follow the guidelines of the concerned department for the safe disposal of E-waste
(E) Air Pollution:
‘Air Pollution Control Area’ under Air (Prevention & Control of Pollution) Act, 1981 on 1st Feb. 1988 and the Act was implemented by the Central Pollution Control Board (CPCB)
Disposal of fallen trees leaves:- Field workers not to burn any type of garbage or dry leaves.
Noise Pollution:- The provision of Noise Pollution Act 1986 shall be applicable.
(F) Water Pollution:
Water (Prevention and Control of Pollution) Act, 1974.
(6) Agricultural and forest areas:-
Size of Nurseries:- The building size for the proposed nurseries in the agricultural area shall be from 1 kanal to 1 acre.
(7) General:-
Volumetric Controls: The volumetric controls on all the building/ sites except residential shall be as follows:
Sr. no.
Area
Parameters
1.
Sector 1 to30
Governedbyarchitecturalcontrol
2.
Sector 31 and beyond in sectoral grid
Governed by such volumetric controls dulyapprovedandprescribed.
3.
All other sites/Plots
Shall be governed by a zoning plan duly approvedbytheChiefAdministrator.
Exemption from FAR:
土
Following areas in various buildings in Chandigarh shall not be counted towards FAR:-
Mumty or stair covers leading to terrace where no habitable use is proposed.
A watchman shelter at every entry/exit point each not exceeding upto 14 sqm. in area.
Mezzanine floor which shall be only 25% of the total area in the hall where such facility is being proposed.
Machine room for lift on top floor as required for lift installation.
Open to sky ramp/staircase for emergency exit.
Service chutes, service ducts for essential services.
Service floor.
Non habitable stilt floor for parking.
Basement for parking and service/storage (minimum of 80% area for parking and maximum of 20% area of services storage in non residential buildings).
Height restrictions:- To comply with the height restrictions in Air funnel zone imposed by Civil Aviation Authorities and Air port Authorities, NOC from these shall be mandatory.
Plinth height:- The plinth height of all the buildings in Chandigarh shall be a minimum of 0.3 m. above the centre of finish level for the street abutting the boundary.
Number of storeys:- There shall be no restriction in the number of storeys in all buildings having volumetric controls in Chandigarh, where height, FAR and ground coverage are already restricted, subject to the condition that clear height shall be maintained as per rules.
Gallery floor and mezzanine floors: Where gallery floors and mezzanine floor are built, they shall comply with the following:-
Multiplex/Malls:
Volumetric Controls:- The following shall be the volumetric control for construction of multiplex/malls specifically earmarked in Chandigarh:-
Sr. No.
Parameters
Norms
1.
PermissibleFAR
1.25
2.
Max.GroundCoverage
40%
3.
Max.Height
22.63 m. (76'-3")
4.
Parking requirements for Newmultiplexes/malls.
4 ECS for per 100 sq mt. of built up area one acre and above 2ECSfor 100 sq.mt. of buit up area below one acre
Conversion of existing Cinema/Theatres into Multiplex Theatres:- The norms applicable on the sites converted from cinema/theatre into Multiplexes in Chandigarh:-
Sr.no.
Parameters
Norms
Condition
1.
Optionforconversion
Allowed
Subject to fulfilment of conditions of notification dated 17.11.2000, 5.4.2004,10.12.2006and8.10.2008.
2.
Total seating capacity of the MultiplexTheatres
Not be more than that of existing Cinemas Theatres and itshall not belessthan 75%of the sanctioned seating capacity
3.
AdditionalFAR
50%oftheexistingFAR
subjecttopaymentofconversioncharges.
4.
Additionandalternation
Allowed
ShallconformtotheBuildingRules. Shall conform to Fire Safety Rules, the Punjab Cinemas Regulation ActandotherrelevantActs/Rules.
5.
useofbasement
Notallowedtobechange
Forparkingandservices
6.
Changeinexterior
Allowed
With the prior approval of the Department of Urban Planning ChandigarhAdministration.
7.
Adequacyofservices
conforming of Town Planning Norms
8.
Commercialarea
Allowed
Allowed up to the area under the cinema halls and projection rooms. If any existing cinema site has some commercial area as a part of the original plan, the same shall be allowed over and above the commercialareaallowedunderthisrule.
Other Educational/Academic sites:
(a) Volumetric Controls:- The following volumetric controls shall be applicable on all the educational/ academic sites in the Sectoral Grid of Chandigarh:-
Sr.No.
Parameters
Norms
Condition
1.
Maximum Ground coverage
15%to25%
2.
MaximumFSI
0.25to0.5(subjecttotheprescribedpayment)
3.
Maximum Height
48'-9"
4.
Maximum No. of floors
4
5.
Height of boundarywall
Upto5'-11½"(solid)+3'-0"(railing)
6.
Parking Requirement
20%ofthetotalplotarea.
7.
Gates and wicket gates
Two main gates andtwo wicket gatesinschool buildingshallbeallowed.
Their location will be determined by the DepartmentofUrbanPlanning,Chandigarh AdministrationonZoningconsideration.
8.
Multipurpose sports hall in schoolsites
Multipurpose sports hall of International Standard (minimum size of 44 m x 22 m) shall be allowed over and above the permissible groundcoverageandFAR.
which have out-door facilities to cater to the size of the football ground, area as per norms, for parking and fire tender movement and still have sufficient open space
9.
Security Cabin/checkpost
Maximum size of security cabin/check post shallbe14sqm.Oneveryentryandexit Area of the security cabin/check post shall be freeofFAR.
(b)
Basement:-
土
Sr.No.
Norms
Condition
1.
i)Optional and it shall not be included in F.S.I. ii)Allowed only below the zoned area of the plot.
It flushes with the ground and is properly landscaped
2.
Uses
Storage, parking, air conditioning plant, lift well etc. in addition, limited use of basement for office space with proper arrangement of light and ventilation, firesafetynorms,circulationetc. Fulfilment of other terms and conditions, whichmay be required for a basement to be used to habitable purpose. Ifsufficientparkingspace,aspernorms, isavailablewithinthesite.
i. They shall be built in any room the height of which is not less than 4.9 m.
ii. Gallery floor shall not cover more than one third, and mezzanine floor shall not cover more than one fourth of the floor area of the rooms in which they occur and
iii. They shall not be lower than 2.28 m. when measured from the surface of the floor to the under surface of the gallery or mezzanine floor.
Any building in Chandigarh shall be used only for the purposes mentioned in the allotment letter and the zoning plan of that particular site.
Annexe:- The height of annexe of 1 kanal houses and above in Phase-I sectors shall be increased upto the maximum height of 24’-9” in the single storey zone for construction for double storey buildings.
Party Walls: Party walls above roof at height of parapet: The party walls of all roof having access by means of staircase shall have party wall of minimum height of 1.8 m, throughout its length between the internal faces of outer parapet walls. Notwithstanding the above, terminal ends of these walls may be shaped for architectural considerations. In the case of multistoreyed flats this provision shall be optional. All parapet walls, balustrade or railings affording protection to roof terrace balconies or verandahs at or above first storey level and having access thereto by staircase door or other opening shall have a height of not less than 0.75 m.
Basement:
土
The major norms applicable to basements shall be as given in the table below:-
Sr.no
Parameters
Norms
Condition
1.
Permissibility of BasementStorey
(i) One basement shall be mandatory in the following categoriesofthebuildingsinthecity:- CinemasconvertedintoMultiplexes. Industrial sites in Industrial area, Phase I & II converted into commercial usage after payment of conversioncharges. ShoppingMalls. Hotelsitesonindependentplots. SitesIntheChandigarhTechnologyPark.Specialsitessuchastheproposed11storeyedtowerinCityCentre,Sector17. Commercial sites, offices and Industrial sites (except educational & residential) comprising independent plotsofoneacreandaboveplotarea. iiThetwinlevelbasementshallbeoptional.
Provisions given under rule 28-C (Use of Basement Storey) of the Punjab Capital (Development and Regulation) Building Rules,1952).
2.
Use of Basement Storey
The one floor of the basement (entrance floor) maybeputtothefollowinguses: (a)Storage of household or other goods of ordinarilyincombustiblematerial. (b)Storagerooms,bank-cellersetc. (c)Air conditioning equipment and other machines usedforservicesandutilitiesofthebuilding;and (d)Parkingspaces. (e)Installation of printing press in respect of press sites. (f)Modernautomaticlaundryshallbeallowedonlyinthebasementofhospitals/nursinghomesites,
Subject to the condition that the effluent of the laundry shall be properly pumped upto the ground floor inspection chambers and discharged to the main sewer.
3.
Habitable use ofbasements
Non-residential habitable use of basements shall be allowed
Allowed in conformity with the Building Byelaws (Rule 28D (iii))/ National Building Code, in this case the ground floor shall have to be higher than the average ground level as prescribed in thecode. HabitablebasementistobecountedintheFAR. Excess FAR composition fee shall be payable as fixedbytheAdministrationfromtimetotime.
4.
Partitions in a basement storey
Allowed
Provided it is used as a single premise or as a serviceareaforupperfloors, In accordance with the Building Byelaws, National building Code and Fire Safety Regulations.
5.
Area for construction for basement
To be constructed within the prescribed set-back and prescribed building lines. In the case of basement meant for parking only, the basement shall be permitted to be extended by additional 10% of the plot area beyond the permissiblebuiltupzoneinplotsmeasuring2kanalsuptooneacreincaseof commercial and institutional buildings, subject to the condition that the basementsoextendedshallbeflushedwiththegroundandroofslabshallbe designed to take the load of fire tender to be ensured by the registered structural engineer and other public safety/other emergency equipments as pertheprovisionsoftheNationalBuildingCode. Twinlevelbasementinthebuiltupareaispermissibleincommercialplotsof more than one acre. If the applicant wants to extend this basement beyond the building plan, the same can be considered for approval subject to the condition that the total car parking generated by commercial site is more than which could be accommodated in the twin level basement and the parking allowed at the surface further subject to the norms determined by the Town Planning and Architecture Department which are based on NBC, buildingbyelawsandtheFireAct.
Provided that the services shall be so arranged that these do not affect the free flow of vehicles/fire tender andshallbeproperlyencasedwithinthebasement.
6.
Height of Basementstorey
The minimum clear height of a basement storey shall be 2.29 mts. ( 7'-6") and maximumheightof basement storey shallbe upto 3.66mts.( 12'-0")from floor to ceiling,subjecttostructurestabilitytobecertifiedby registeredstructureengineer. However , in case of the services such as printing press , Lift , Ac Plant , Electrical panels, Filtration Plants, Laundry Plants or machines related with the services relating to the use of the site, the clear height upto 16'-6" shall be allowed by the competent authority subject tot the condition that no mezzanine floor shall be permittedafterensuringthestructurestabilityandprovisionsoffiresafetyrules.
However, the height for mechanical parking in basement shall be as approved by Chandigarh Administrationoncasetocasebasis.
7.
Access to Basement
The access to the basement shall be separate from the main and alternative staircase providing access and exit from height floors. Where the staircase is continuousinthecaseofbuildingservedbymorethanonestaircase,thesameshall beofenclosedtypeservingasafireseparationfromthebasement,floorandhigher floors. Open ramps shall be permitted if they are constructed within the building linesubjecttotheprovisionofadequatesurfacedrainageprovisions.
8.
Lighting and ventilation of basementstorey
An open area of a minimum width of 1.8 mtrs. shall be provided across the full length and/or width of a basement storey. This area shall be within the limits of the site and shall be paved with impervious material above a concrete bed. It shall be completely unobstructed except that in this area stepsmaybeallowedforaccesstoit,ifconsiderednecessary. Basementstoreyshallbeandventilatedbymeansofwindowsoraminimumareaor1/10<sup>th</sup>ofthetotalfloorareaatleasthalfofwhichmustopen. The basement storey for any other purpose conforming to the land use of thesitecanbeallowed.
Providedthatthisprovisionshallnotapplytothebasementstoreyincitycentrei.e.Sector17orin such other area as may be specified by the Chief Administrator. Where it may not be possible to provide open areas, the access to the basement storey in such case be provided through the groundofthebuilding In case of buildings governed by architectural control, the provision of light and ventilation shallbeasshowninthecontrolsheets.
Adequate ventilation shall be provided for the basement. The ventilation requirements shall be the same as required by the particular occupancy according to byelaws. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers,exhaustfans,airconditioningsystemsetc.
Proper light and ventilation as required under the rule is provided or proper air conditioningismade. Thebasementareaofsuchusesshallbe counted as part of the permissible covered area/floor space index of the site.
9.
Dampproofing of basement storey
The walls of the basement storey shall be properly damp proofed and if in contact with the soil, they must be effectually secured against dampness from the soil with vertical and horizontal damp proofcourse.
10.
Structural requirements of Basement Storey
The wall of a basement storey shall have a thickness at the base or at any section and not less than 1/3<sup>rd</sup> the height of the base or the section below the ground level, unless the thickness has been determinedbycalculationsofthewallactingasaretainingwall.
11.
Drainage of Basement
a) Open area adjoining a basement storey, if any, shall be effectually drained to the satisfaction of the Chief Administrator. b) The responsibility for draining a basement storey and for protecting it from rain and surface water shall be that of the owner.
Timber sites:- The norms applicable on Timber sites in Chandigarh are as given below:-
Sr.no.
Parameters
Norms
Condition
1.
Use of building
Not be used for fabrication of any items other than those notified.
2.
Additional constructio n
Allowed
But within the existing 12'-9" height of the boundarywall.
3.
Permission of basement
Notallowed
4.
Deviation in the outer façade
Notallowed
5.
Maximum ground coverage
Increased from 50% to 60% of the site/plot area.
On Payment Of CompositionFee
Ware housing:-
a. Basement
Sr.No.
Parameters
Norms
1.
Provision of basementstorey
Allowed
2.
FAR of basement storey
Shall not exceed 100% of the area of the site coverage of the building of whichitformsapart.
b. Lobby, Corridor, Passage or balcony:-
Sr.No.
Typeoffloor/unit
Maximum number of lobby, corridor, passage or balcony per floor
1.
Upto20
1.4 m.
2.
20to100
1.8 M.
3.
101onwards
2.3 M.
Bulk Material Shops:- The following norms shall be applicable on Bulk Material shops in Chandigarh:-
Sr.no.
Parameters
Norms
1.
GroundCoverage
60%
2.
FAR
.6
3.
Max. Number of storeys
2
4.
BuildingHeight
Singlestoreyzone12'-9"Doublestoreyzone24'-9"
Motor Market: The construction of Motor Markets proposed in Chandigarh shall be governed by Architectural Controls prepared by the O/o Chief Architect, Department of Urban Planning, Chandigarh Administration.
Conversion of Coal Depot: The conversion of coal depot site shall be permissible for the uses as follows:-
Godown & LPG godowns.
Storage and hiring of shuttering materials.
Storage and sale of bamboos, cane projects, ropes, ban, tokries, wooden ladders etc.
Painting and sign board, banners, printing glow signs etc.
Storage of tent, utensils, crockery, furniture etc.
Cement godowns/stores/
Offices of general nature
Printing press
Computer training and applications; type and shorthand training, or job work.
Laundry and dry cleaning.
Manufacturing and sale of furniture.
Book binding and embossing
Coal depot sites having an additions access from the V-4 roads can also be used for service stations, restaurant or banks.
Permissibility of commercial activity on Railway land:- It is proposed to develop the Chandigarh railway station as a Transport hub as envisaged by Ministry of Railways, GOI. However, the commercial activities in the railway land shall be done in accordance with prevailing norms/regulations/policies of the Chandigarh Administration and as per other provisions contained in this Master Plan, subject to the fulfilment of conditions including any fee and development charges as stipulated by the Administration.
Solar Water Heating System: All commercial as well as Hotels, Lodges and Guest Houses, which have use of hot water shall have solar water heating system of adequate capacity installed. The existing buildings which do not have those facilities shall provide this facility within one year from the date these orders are notified in the official gazette.
Industrial:
土
Various norms applicable to Industrial Areas/sites in Chandigarh are as given
Table 1
Sr.No.
Parameter
Norms
Condition
1.
Amalgamation
Allowed
Subject to the condition that the revised plans are approved by the competentauthority,priorthereto.
2.
Fragmentation
Not Allowed
3.
Increase in covered area/FSI of industrial buildings in Phase-I&II,industrialarea
Groundcoverage i.Fortheplotshavinganareaupto1acre. ii.Plots having an area above 1acres. iii.Being governed by the Arch.Controls
60%60% for 1 acre and area above1<sup>st</sup>one acre40%. Asprovidedintherespective architectural controls applicable.
5.
AdditionalCoverage Ifitisnotpossibletoprovide the said additional coverage in the form of single storied shedwithinzonedarea
10% of the permissible groundcoverage.
Withinthezonedarea. For the purpose of single storeyed shed with unapproachable terrace. For storage of material, generator set, parking and pollution control devices. Lightandventilationofthebuildingisnotaffected. ApprovaloftheChiefAdministratorisobtainedinadvance. Subject to the condition that it is atleast 6'-0" away from the boundarywall. TheDepartment ofUrbanPlanning,ChandigarhAdministrationshall suitablyamendalltherelevantarchitecturalcontrols/zoningplansas applicable to various categories of industrial plots in Industrial Area, Phase-I&II,Chandigarh.
6.
Gate keeper/watchman office in Industrial Area, Phase-II
Lobby, Corridor, Passage or balcony:- The parameters of Lobby, Corridor, Passage or Balcony shall be applicable on all industrial plots as given below:-
Sr. No.
Type of floor/unit
Minimum width
1.
Upto 20
1.4 M.
2.
20 to 100
8.M.
3.
101wards
23M.
Basement:- The provision of basement in all industrial plots shall be made as below:-
Sr. No.
Parameters
Norms
1.
Provision of basement storey
Allowed
2.
FAR of basement storey
Shall not exceed 100% of the area of the site coverage of the building of which it forms a part
Conversion of industrial plots into commercial activities:-
However, height upto 7.0 mts required for services like water chillar plant, lift machine room, mumty, overhead water tanks, solar tanks & DG set shall be allowed subject to the NOCs from Civil Aviation and Air port authority shall be required.
4.
Parking
Minimum15%oftotalplotareaatsurfacelevel.
2kanal upto oneacre 2 ECS per 100 sq.mt. builtuparea One acre and above 4 ECS per 100 sq.mt. builtuparea.
5
Basement
Twin level basement in the built up area is permissible in commercial plotsofmorethan oneacre.Iftheapplicantwants to extend this basement beyond the building plan, the same can be considered for approval subject to the condition that thetotalcarparkinggeneratedbycommercialsiteismorethan whichcouldbeaccommodated inthetwinlevelbasement and theparkingallowedatthesurfacefurthersubjecttothenorms determined by the Town Planning and Architecture DepartmentwhicharebasedonNBC,buildingbyelawsandthe FireAct.
6
Access
The access to the parking in the basement is as per the norms of the National Building Code in plot size of one acre and above.Inthecaseofplotsbelowoneacresize,onerampanda staircasepreferablyinoppositedirectionshallbescrutinizedby the committee, in case the owner wants to avail the relaxation in clause10.9ofpart 3ofNBCand makesan application under 7.6ofpart2ofthesaidCodeforthepurpose.
b) Other Controls:
土
Sr.No.
Parameters
Norms
Condition
1.
Permissibility ofconversion
Allowed either by converting the land use or by fresh construction in accordance with the guidelines of the architecturalcontrols
After payment of conversion fee in the manner prescribed in thescheme.
2.
Lower Ground Floor
Allowed which is more than half of its height above the mean ground level andrestoftheheight below the mean ground level.
Subject to the mandatory setbacks as per provisions of Fire Safety Act and National BuildingCodeguidelines.
3.
Basement
Twinlevelbasement inthe built up area is permissible in commercial plots of more than one acre. If the applicant wants to extend this basement beyond the buildingplan,thesamecan be considered for approval subject to the condition that the total car parking generated by commercial site is more than which couldbeaccommodated in the twin level basement and the parking allowed at the surface further subject to the norms determined by the Town Planning and Architecture Department which are based on NBC, building bye laws and the FireAct.
Subject to the mandatory setbacks as per provisions of Fire Safety Act and National Building Code guidelines.
4. INSTITUTIONAL:
The development controls/norms on various types of Institutional Buildings shall be applicable as given below:-
A. General
Public buildings:-
i) Lobby, Corridor, Passage or balcony:-
Sr.No.
Typeoffloor/unit
Minimum width in M.
1.
Upto 20
1.4
2.
20 to 100
1.8
3.
101 onwards
2.3
ii) Basement
Sr. No.
Parameters
Norms
1.
Provision of basement storey
Allowed
2.
FAR
Shall not counted towards FAR
• Staircase:-
Sr. No.
No. of users
Minimum clear width
1.
Numberofusersupto200
1.4ms.
2.
Numberofusersupto200to300
1.8 m.
3.
Increase (2.5 cms) for every additional 15 persons until a maximum of9'isreached.
IT Park, Phase-I & II:
土
i. Following volumetric controls shall be allowed in Rajiv Gandhi Chandigarh Technology Park for Built to Suite site, Main, Campus site and Small Campus sites:-
Sr.no
Site
Site coverage
FSI
Height
1.
BTS
40%
1.50
74'-3"
2.
MainCampus
40%
1.50
74'-3"
3.
Smallcampus
40%
1.50
74'-3"
ii. Other parameters applicable on sites for IT Park, Phase-I & II are as follows:-
6Acres2-6Acres Sites of any size may be earmarked as Built tosuitsites
2
PermissibleUses
Information services such as software development and IT enabled services, other relatednon-pollutingactivities.
Provisions of support facilities such as canteen, catering,sports,entertainment,etc.Upto20%ofthetotalbuiltuparea.
C) Educational Institutes:
•Educity:- There shall be following volumetric controls for the construction of educational buildings in Education city in Chandigarh:-
Sr. No
Parameters
Norms
1.
Maximum Ground coverage
40%
2.
Maximum FAR
1.5
3.
Maximum Height
57'-6" upto top of parapet.
3.
Toilets, pantry,labs etc. which require water, are notallowed in basement
The areaofbasementwithhabitable useshall be counted towards maximum permissible FARof0.5.
(C) Cultural and other non-academic institutional sites:- The following volumetric controls shall be applicable on all the cultural and other non academic institutional sites in Sectoral Grid of Chandigarh:-
Sr. No.
Parameters
Norms
1.
Maximum Ground coverage
40%
2.
MaximumFSI
1.25
3.
Maximum Height
48'-9"
4.
MaximumNo.offloors
4
(D) Religious sites:- The following volumetric controls shall be applicable on all the religious sites in sectoral grid of Chandigarh:-
Sr.No.
Parameters
Norms
1.
MaximumGroundcoverage
40%
2.
MaximumFSI
1.00
3.
MaximumHeight
36'-0"
4.
MaximumNumberoffloors
3
(E) Integrated Hostel sites:- The following volumetric controls shall be applicable on all the Integrated Hostels sites in sectoral grid of Chandigarh:-
Sr.No.
Parameters
Norms
1.
Maximum Ground coverage
40%
2.
MaximumFSI
1.25
3.
MaximumHeight
48'-9"
4.
MaximumNo.offloors
4
(E) Nursing Homes:- The following relaxation for the use of basement by Nursing in public interest is as under:-
• Administrative office and accounts.
Ultrasound machine with allied services.
Lithotripsy machine.
Physiotherapy Department.
Radiology department.
Any plant, machinery related to diagnostics and Nursing Home, which does not require consumption and disposal of water or use of chemicals or any such item which can generate fire or can cause fire or which can generate foul smell or gas injurious to human health. The area under such habitable use of basement would be counted towards permissible FAR and subject to provision of adequate parking, circulation, light and ventilation, fire protection as per norms.
(F) Parking on Integrated /dedicated projects:-
Sr. No.
Parameters
Norms
1.
On Educational/ InstitutionalPart
Norms of educational/institutional sitesshallbeapplicable
2.
On the hospital part
3 ECS per 100 sq. mtrs. of built up hospitalarea
3.
On residential part
1.8 ECS per 100 sq. mtrs. of built up area
4.
On commercial part
4 ECS per 100 sq. mtrs. of built up commercialarea
(G) Solar Water Heating System:
(i) All institutional buildings which have use of hot water shall have solar water heating system of adequate capacity installed. The existing buildings which do not have those facilities shall provide this facility within one year from the date these orders are notified in the official gazette.
(ii) Provision of Solar Water Heating System shall be compulsory in the following categories of buildings:-
a) Hospitals and Nursing Homes
b) Hostels of schools, colleges, Training Centres.
5. Environment
(a) Water Conservation
Use of recycled water shall be compulsory for the following:-
All buildings with an area of more than 2000 sq. m. in all new developments. If such water is not supplied by the MC, then the building should set up water treatment plant within its premises for reuse of waste water.
All apartments or group housing complexes with more than 20 tenements and commercial, institutional and industrial complexes with an area of more than 2000 sq.m.
Watering parks, gardens landscapes, golf courses, use for construction, laundry, industrial process, flushing, washing roads etc.
(B) Storm Water Management
a. Zero Drainage of Storm water for the following shall be compulsory:
All the housing and institutional campuses etc. with a total site area more than 30 acres.
The Integrated campuses/sites like P.G.I, C.S.I.O., IMTECH, P.U., PEC, GMCH, Sector 17, Sector 34.
Ramp:-
The clear width of the ramp leading to the basement shall be 4.00 m with an adequate slope not less than 1:10.
Separate entry/exit of ramps in the basement should be provided and the ramp for basement parking shall be allowed out side the zoned area subject to fire tender movement.
The ramp shall be on non slippery surface.
Barrier free approach:- Barrier free approach shall be compulsory in all non-residential sites in Chandigarh to facilitate differently abled persons.
Toilets for especially abled person:- Toilets for especially abled person shall be compulsory in all non-residential sites in Chandigarh to facilitate differently abled persons.
Courtyard: Where the minimum size of courtyard for providing light and ventilation to the basement is provided i.e. Minimum width in all directions is 3 meters as specified in rule 20 of the Punjab Capital (Development and Regulation) Building Rules, 1952.
“Lighting and Ventilation of Basement Storey: An open area of a minimum width of 1.8 m. shall be provided across the full length and/or width of a basement storey. This area shall be within the limits of the site and shall be completely unobstructed except that in this area steps may be allowed for access to it, if considered necessary.
Provided that this provision shall not apply to the basement storey in city centre i.e. Sector 17 or in such other area as may be specified by the Chief Administrator . Where it may not be possible to provide open areas, the access to the basement storey in such cases be provided through the ground floor of the building.”
Lift: Lift shall be allowed to open in basement of buildings in Chandigarh.
Site coverage of Basement Storey:
土
Sr.No.
Extent/ area of construction
Norms
Other conditions
1.
Extentofconstructionof basementarea
i) 100%ofthetotalpermissiblegroundcoverage, subject to the provisions of the Punjab Capital (Development & Regulation) Building Rules, 1952andtechnicalfeasibilityatsite. ii) In the case of basement meant for parking only, the basement shall be permitted to be extended by additional 10% of the plot area beyond the permissible built up zone in plots measuring 2 kanals upto one acre in case of commercialandinstitutionalbuildings.
1) Subject to the condition that the basement so extended shall be flushed with the ground and roof slab shall be designed to take the load offire tender to be ensure by theregisteredstructuralengineerandother public safety/ other emergency equipments as per the provisions of the National BuildingCode. 2) Provided that the services shall be so arranged that these do not affect the free flow of vehicles/fire tender and shall be properlyencasedwithinthebasement.
2.
Minimum 'no basement zone'
8' wide on the side of the plot where the adjoining building/house is already constructed without basement.
Tomaintainthestructuralstability.
3.
Maximum height of a basementstorey
3.66 mtrs.
2.29mts.underthesoffitofbeam.
b) Other Requirements:-
The requirements of basement shall be as following s:-
Every basement shall be in every part at least 2.28 m. in height from the floor to the underside of the roof slab or ceiling.
Adequate ventilation shall be provided for the basement. The ventilation requirements shall be the same as required by the particular occupancy according to byelaws. Any deficiency may be met by providing adequate mechanical ventilation in the form of blowers, exhaust fans, air conditioning systems etc.
Adequate arrangements shall be made such that surface drainage does not enter the basement.