There is a large stock of non engineered buildings within Chandigarh which have been constructed without following the codal provisions. The city falls within the high risk prone Seismic Zone IV wherein special measures need to be taken to equip the buildings to be able to withstand earthquakes. Due to the high density development, the unsafe buildings which share common walls, can endanger the life and property of the neighbouring buildings. Some of the major observations are that
(i) The brick work is not of good quality, mortar between brick work is not adequate
(ii) Majority of walls are without plaster which make them more vulnerable to salt attack and less durable
(iii) There are no RCC lintels over wide windows and door openings
(iv) RCC bands required for structural safety during quakes are not provided
(v) Vertical reinforcement at corner of masonry walls are not provided.
(vi) Four storeyed non engineered buildings are very unsafe during quakes. Due to height of four storeyed structures, large bending moments and sheer forces are developed at the base which a non engineered building is unable to bear.
(vii) Vertical alignment of walls is not proper which can cause additional tensile stresses which may cause failure.
(viii) Clear space between buildings on either side of lane is not adequate due to cantilever projections on both sides.
(ix) Masonry columns taking load of upper floors on the floor itself without foundation. Due to lateral movement of the ground during seismic activity, the column can become a critical component.
(x) Masonry columns originating from walls without adequate bond with the wall. During earth quakes, the columns can become critical.
(xi) Staircases in many buildings are resting on cantilever slab which is not desirable.
(xii) Load bearing masonry wall of upper storey is not placed above the masonry wall of the storey below. The walls are displaced by about a feet which is not a proper structural arrangement.
There are a large number of buildings which were designed /allotted as single storeyed initially but have been constructed with additional floors without following the structural safety norms /provisions. Such housing stock also needs to be structurally audited.
On the basis of visual surveys, the following areas are recommended for structural auditing:
Cheap houses in various sectors – Sector 15, 19, 20, 24, 32 etc.
Rehabilitation colonies - Bapu Dham Colony etc
Site and Services schemes of Sector 25.
EWS houses of Sector 29B, & TBRL, OFC houses in Sector 29.
Housing stock within the old abadi deh of Manimajra as well as in the organic developments around it including, Gobindpura, Mori Gate, Bhara Mal Nagar, Dehra Sahib, Mata Raj Kaur, Darshini Dagh, Thakur Dwara, Shanti Nagar Pipliwala Town, Mariwala Town, Subhash Nagar and Bank Colony.
Housing stock within and outside the abadi deh of villages
A systematic examination of the structural safety of the housing units shall be undertaken which will guide follow up action – redevelopment /retrofitting /urban renewal to be undertaken.