6.1 General
6.1.1 The design in steel may be done using the limit state method, which is generally based on the following basic aspects/principles:
a) It makes use of the plastic range of material for the design of structural members and incorporates load factors to take into account the variability of loading configurations.
b) It considers the good performance of steel in tension compared to compression and specifies variable factors. It takes into account this variance by defining limit states which address strength and serviceability.
c) According to this method, a structure or part of it, is considered unfit for use when it exceeds the limit state beyond which it infringes any one of the criteria governing its performance or use.
d) The two limit states are classified as the Ultimate Limit State and Serviceability Limit State. The limit states take care of the safe operation and adequacy of the structure from strength point of view. The criteria which are used to define the ultimate limit state are yielding, plastic strength, fatigue, buckling, etc. Serviceability limit state takes care of the performance and behaviour of the structure during its service period. Deflection, vibration, drift, etc are considered as serviceability criteria.
e) Limit state method considers the critical local buckling stress of the constituent plate element of a member. This method has provisions to enhance resistance of plate elements against local buckling by suitably reducing the slenderness ratio. Hence, it is possible to develop the full flexural moment capacity of a member subjected to flexure or the Limit State in flexure for a beam. In Limit State Method, based on slenderness ratio of the constituent plate elements, a member can be classified as Slender, Semi-compact, Compact and Plastic. This section classification becomes essential as the moment or load capacities of each of these sections take different values depending upon these classifications.
6.1.2 In this method, the factored loads, in different combinations, are applied to the structure to determine the load effects. The latter are then compared with the design strength of the elements.
This is expressed mathematically as:
The effects of
[Function of G y and other geometric variables]
where
γ L = Partial factor for loads.
γ f Factor that takes into account the inaccuracies in assessment of loads, stress distribution and construction tolerances.
γ m 1 , γ m 2 = Factors that take into account, uncertainties in material strength and quality, and manufacturing tolerances respectively.
Q k = Specified nominal load induced based on design stipulations.
σ y = Yield strength of the material.
6.2 The detailed design procedure shall be as agreed between the parties concerned.
NOTE — At the time of publication of this Section IS 800 was under revision and once the revised IS 800 is published, the same shall replace the provisions given in this section.