5.2.1 For the purpose of earthquake resistant design
of buildings in this standard, the following definitions shall apply:
5.2.2 Base
It is the level at which inertia forces generated in the structure are transferred to the foundation, which then transfers these forces to the ground.
5.2.3 Base Dimensions (d)
Base dimension of the building along a direction is the dimension at its base, in metres, along that direction.
5.2.4 Centre of Mass
The point through which the resultant of the masses of a system acts. This point corresponds to the centre of gravity of masses of system.
5.2.5 Centre of Stiffness
The point through which the resultant of the restoring forces of a system acts.
5.2.6 Design Eccentricity (edi)
It is the value of eccentricity to be used at floor i in torsion calculations for design.
5.2.7 Design Seismic Base Shear (VB)
It is the total design lateral force at the base of a structure.
5.2.8 Diaphragm
It is a horizontal, or nearly horizontal system, which transmits lateral forces to the vertical resisting elements, for example, reinforced concrete floors and horizontal bracing systems.
5.2.9 Dual System
Buildings with dual system consist of shear walls (or braced frames) and moment resisting frames such that:
a) the two systems are designed to resist the total design lateral force in proportion to their lateral stiffness considering the interaction of the dual system at all floor levels; and
b) the moment resisting frames are designed to independently resist at least 25 percent of the design base shear.
5.2.10 Height of Floor (hi)
It is the difference in levels between the base of the building and that of floor i.
5.2.11 Height of Structure (h)
It is the difference in levels, in metres, between its base and its highest level.
5.2.12 Horizontal Bracing System
It is a horizontal truss system that serves the same function as a diaphragm.
5.2.13 Joint
It is the portion of the column that is common to other members, for example, beams, framing into it.
5.2.14 Lateral Force Resisting Element
It is part of the structural system assigned to resist lateral forces.
5.2.15 Moment-Resisting Frame
It is a frame in which members and joints are capable of resisting forces primarily by flexure.
5.2.15.1 Ordinary moment-resisting frame
It is a moment-resisting frame not meeting special detailing requirements for ductile behaviour.
5.2.15.2 Special moment-resisting frame
It is a moment-resisting frame specially detailed to provide ductile behaviour and comply with the requirements given in IS 4326 or IS 13920 or SP 6(6).
5.2.16 Number of Storeys (n)
Number of storeys of a building is the number of levels above the base. This excludes the basement storeys, where basement walls are connected with the ground floor deck or fitted between the building columns. But, it includes the basement storeys, when they are not so connected.
5.2.17 Principal Axes
Principal axes of a building are generally two mutually perpendicular horizontal directions in plan of a building along which the geometry of the building is oriented.
5.2.18 P − Δ Effect
It is the secondary effect on shears and moments of frame members due to action of the vertical loads, interacting with the lateral displacement of building resulting from seismic forces.
5.2.19 Shear Wall
It is a wall designed to resist lateral forces acting in its own plane.
5.2.20 Soft Storey
It is one in which the lateral stiffness is less than 70 percent of that in the storey above or less than 80 percent of the average lateral stiffness of the three storeys above.
5.2.21 Static Eccentricity (esi)
It is the distance between centre of mass and centre of rigidity of floor i.
5.2.22 Storey
It is the space between two adjacent floors.
5.2.23 Storey Drift
It is the displacement of one level relative to the other level above or below.
5.2.24 Storey Shear (V )
It is the sum of design lateral forces at all levels above the storey under consideration.
5.2.25 Weak Storey