IS 875 (Part 2) : 1987 Code of practice for design loads (other than earthquake) for buildings and structures: Part 2 Imposed loads (second revision)
IS 875 (Part 3) : 1988 Code of practice for design loads (other than earthquake) for buildings and structures: Part 3 Wind loads (second revision)
IS 875 (Part 4) : 1987 Code of practice for design loads (other than earthquake) for buildings and structures: Part 4 Snow loads (second revision)
IS 875 (Part 5) : 1987 Code of practice for design loads (other than earthquake) for buildings and structures: Part 5 Special loads and load combinations (second revision)
This Section has to be read together with Sections 2 to 7 of Part 6 ‘Structural Design’.
A reference to SP 64 (S&T) : 2001 ‘Explanatory Handbook on Indian Standard Code of practice for design loads (other than earthquake) for buildings and structures: Part 3 Wind loads IS 875 (Part 3) : 1987’ may be useful. This publication gives detailed background information on the provisions for wind loads and also the use of these provisions for arriving at the wind loads on buildings and structures while evaluating their structural safety.
Reference may also be made to the Vulnerability Atlas of India, 1997 and Landslide Hazard Zonation Atlas of India, 2003 Building Materials and Technology Promotion Council, Ministry of Urban Development and Poverty Alleviation, Government of India. The vulnerability Atlas contains information pertaining to each State and Union Territory of India, on (a) seismic hazard map, (b) cyclone, and wind map, (c) flood prone area map, and (d) housing stock vulnerability table for each district indicating for each house type the level of risk to which it could be subjected. The Atlas can be used to identify areas in each district of the country which are prone to high risk from more than one hazard. The information will be useful in establishing the need of developing housing designs to resist the combination of such hazards.
All standards, whether given herein above or cross-referred to in the main text of this Section, are subject to revision. The parties to agreement based on this Section are encouraged to investigate the possibility of applying the most recent editions of the standards.
Section 1 Loads, Forces and Effects
1Scope
1.1 This Section covers basic design loads to be assumed in the design of buildings. The imposed loads, wind loads, seismic loads, snow loads and other loads, which are specified herein, are minimum working loads which should be taken into consideration for purposes of design.
1.2 This Section does not take into consideration loads incidental to construction.
2Dead Load
2.1 Assessment of Dead Load
The dead load in a building shall comprise the weight of all walls, partitions, floors and roofs, and shall include the weights of all other permanent constructions in the building and shall conform to good practice [6-1(1)].
3Imposed Load
3.1 This clause covers imposed loads (live loads) to be assumed in the design of buildings. The imposed loads specified herein are minimum loads which should be taken into consideration for the purpose of structural safety of buildings.
NOTE — This Section does not cover detailed provisions for loads incidental to construction and special cases of vibration, such as moving machinery, heavy acceleration from cranes, hoists and the like. Such loads shall be dealt with individually in each case.
3.2 Terminology
3.2.1 For the purpose of imposed loads specified herein, the following definitions shall apply:
3.2.1.1 Assembly Buildings — These shall include any building or part of a building where groups of people congregate or gather for amusement, recreation, social, religious, patriotic, civil, travel and similar purposes; for example, theatres, motion picture houses, assembly halls, city halls, marriage halls, town halls, auditoria, exhibition halls, museums, skating rinks, gymnasiums, restaurants (also used as assembly halls), place of worship, dance halls, club rooms, passenger stations and terminals of air, surface and other public transportation services, recreation piers and stadia, etc.
3.2.1.2 Business Buildings — These shall include any building or part of a building, which is used for transaction of business (other than that covered by mercantile buildings); for keeping of accounts and records for similar purposes; offices, banks, professional establishments, court houses, and libraries shall be classified in this group so far as principal
function of these is transaction of public business and the keeping of books and records.
3.2.1.3 Dwellings — These shall include any building or part occupied by members of single/multi-family units with independent cooking facilities. These shall also include apartment houses (flats).
5
3.2.1.4 Educational Buildings — These shall include any building used for school, college or day-care purposes involving assembly for instruction, education or recreation and which is not covered by assembly buildings.
3.2.1.5 Imposed Load — The load assumed to be produced by the intended use or occupancy of a building including the weight of movable partitions, distributed and concentrated loads, loads due to impact and vibration, and dust loads but excluding wind, seismic, snow and other loads due to temperature changes, creep, shrinkage, differential settlement, etc.
3.2.1.6 Industrial Buildings — These shall include any building or a part of a building or structure, in which products or materials of various kinds and properties are fabricated, assembled or processed like assembly plants, power plants, refineries, gas plants, mills, dairies, factories, workshops, etc.
3.2.1.7 Institutional Buildings — These shall include any building or a part thereof, which is used for purposes, such as, medical or other treatment in case of persons suffering from physical and mental illness, disease or infirmity; care of infants, convalescents or aged persons and for penal or correctional detention in which the liberty of the inmates is restricted. Institutional buildings ordinarily provide sleeping accommodation for the occupants. It includes hospitals, sanitoria, custodial institutions or penal institutions like jails, prisons and reformatories.
3.2.1.8 Occupancy or Use Group — The principal occupancy for which a building or part of a building is used or intended to be used; for the purpose of classification of a building according to occupancy, an occupancy shall be deemed to include subsidiary occupancies which are contingent upon it. The occupancy classification is given in the following groups.
3.2.1.9 Office Buildings — The buildings primarily to be used as an office or for office purposes; ‘office purposes’ include the purpose of administration, clerical work, handling money, telephone and telegraph operating, and operating computers, calculating machines, ‘clerical work’ includes writing, book-keeping, sorting papers,
typing, filing, duplicating, punching cards or tapes, drawing of matter for publication and the editorial preparation of matter for publication.
3.2.1.10 Mercantile Buildings — These shall include any building or a part of a building which is used as shops, stores, market for display and sale of merchandize either wholesale or retail. Office, storage and service and facilities incidental to the sale of merchandize and located in the same building shall be included under this group.
3.2.1.11 Residential Buildings — These shall include any building in which sleeping accommodation is provided for normal residential purposes with or without cooking or dining or both facilities (except buildings under institutional buildings). It includes one or multi-family dwellings, apartment houses (flats), lodging or rooming houses, restaurants, hostels, dormitories and residential hotels.
3.2.1.12 Storage Buildings — These shall include any building or part of a building used primarily for the storage or sheltering of goods, wares or merchandize, like warehouses, cold storages, freight depots, transity sheds, store houses, garages, hangers, truck terminals, grain elevators, barns and stables.
3.3Imposed Loads on Floors Due to Use and Occupancy
3.3.1 Imposed Loads
The imposed loads to be assumed in the design of buildings shall be the greatest loads that probably will be produced by the intended use or occupancy, but shall not be less than the equivalent minimum loads specified in Table 1 subject to any reductions permitted in 3.3.2.
Floors shall be investigated for both the uniformly distributed load (UDL) and the corresponding concentrated load specified in Table 1, and designed for the most adverse effects but they shall not be considered to act simultaneously. The concentrated loads specified in Table 1 may be assumed to act over an area of 0.3 m × 0.3 m. However, the concentrated loads need not be considered where the floors are capable of effective lateral distribution of this load.
All other structural elements shall be investigated for
the effects of uniformly distributed loads on the floors specified in Table 1.
1 Where, in Table 1, no values are given for concentrated load, it may be assumed that the tabulated distributed load is adequate for design purposes.
2 The loads specified in Table 1 are equivalent uniformly distributed loads on the plan area and provide for normal effects of impact and acceleration. They do not take into consideration special concentrated loads and other loads.
3 Where the use of an area or floor is not provided in Table 1, the imposed load due to the use and occupancy of such an area shall be determined from the analysis of loads resulting from:
a) weight of the probable assembly of persons;
b) weight of the probable accumulation of equipment and furnishing;
c) weight of the probable storage materials; and
d) impact factor, if any.
4 While selecting a particular loading, the possible change in use or occupancy of the building should be kept in view. Designers should not necessarily select in every case the lower loading appropriate to the first occupancy. In doing this they might introduce considerable restrictions in the use of the building at a later date, and thereby reduce its utility.
5 The loads specified herein, which are based on estimations, may be considered as the characteristic loads for the purpose of limit state method of design till such time statistical data are established based on load surveys to be conducted in the country. 6 When an existing building is altered by an extension in height or area, all existing structural parts affected by the addition shall be strengthened where necessary and all new structural parts shall be designed to meet the requirements for building hereafter erected.
7 The loads specified in the section does not include loads incidental to construction. Therefore, close supervision during construction is essential to ensure that overloading of the building due to loads by way of stacking of building materials or use of equipment (for example, cranes and trucks) during construction or loads which may be induced by floor to floor propping in multi-storeyed construction, does not occur. However, if construction loads were of short duration, permissible increase in stresses in the case of working stress method or permissible decrease in load factors in limit state method, as applicable to relevant design codes, may be allowed for.
8 The loads in Table 1 are grouped together as applicable to buildings having separate principal occupancy or use. For a building with multiple occupancies, the loads appropriate to the occupancy with comparable use shall be chosen from other occupancies.
9 Regarding loading on lift machine rooms including storage space used for repairing lift machines, designers should go by the recommendations of lift manufacturers for the present. Regarding loading due to false ceiling, the same should be considered as imposed loads on the roof/floor to which it is fixed.
Table 1Imposed Floor Loads for Different Occupancies (Clause 3.3.1)
Sl No.(1)
Occupancy Classification(2)
Uniformly Distributed Load (UDL)(3)
Concentrated Load(4)
i) Residential Buildingsa) Dwelling houses:
KN/m²
KN
Table 1Continued
(1)
(2)
(3)
(4)
3) Corridors, passages, staircases including fire escapes and store rooms
3.0
4.5
4) Balconies
3.0
1.5 per metre run concentrated at the outer edge
b) Dwelling units planned and executed in accordance with [6-1(2)] only:
1) Habitable rooms, kitchens, and toilets and bathrooms
1.5
1.4
2) Corridors, passages and staircases including fire escapes
1.5
1.4
3) Balconies
3.0
1.5 per metre run concentrated at the outer edge
c) Hotels, hostels, boarding houses, lodging houses, dormitories and residential clubs:
1) Living rooms, bed rooms and dormitories
2.0
1.8
2) Kitchen and laundries
3.0
4.5
3) Billiards room and public lounges
3.0
2.7
4) Store rooms
5.0
4.5
5) Dining rooms, cafeterias and restaurants
4.0
2.7
6) Office rooms
2.5
2.7
7) Rooms for indoor games
3.0
1.8
8) Baths and toilets
2.0
—
9) Corridors, passages staircases including fire escapes and lobbies as per the floor services (excluding stores and the like) but not less than
3.0
4.5
10) Balconies
Same as rooms to which they give access but with a minimum of 4.0
1.5 per metre run concentrated at the outer edge
d) Boiler rooms and plant roomsto be calculated but not less than
5.0
6.7
e) Garages:
1) Garage floors (including parking area and repair workshops for passenger cars and vehicles not exceeding 2.5 tonnes gross weight, including access ways and ramps — to be calculated but not less than
2.5
9.0
2) Garage floors for vehicles not exceeding 4.0 tonnes gross weight (including access ways and ramps) — to be calculated but not less than
5.0
9.0
Table 1Continued
(1)
(2)
(3)
(4)
iii)
Institutional Buildings
a) Bed rooms, wards, dressing rooms, dormitories and lounges
2.0
1.8
b) Kitchens, laundries and laboratories
3.0
4.5
c) Dining rooms, cafeterias and restaurants
3.0¹⁾
2.7
d) Toilets and bathrooms
2.0
—
e) X-ray rooms, operating rooms and general storage areas — to be calculated but not less than
3.0
4.5
f) Office rooms and O.P.D. rooms
2.5
2.7
g) Corridors, passages, lobbies, staircases including fire escapes — as per the floor serviced (without accounting for storage and projection rooms) but not less than
4.0
4.5
h) Boiler rooms and plant rooms — to be calculated but not less than
5.0
4.5
j) Balconies
Same as rooms to which they give access but with a minimum of 4.0
1.5 metre run concentrated at the outer edge
iv)
Assembly Building
a) Assembly areas:
1) With fixed seats 2)
4.0
—
2) Without fixed seats
5.0
3.6
b) Restaurants (subject to assembly), museums and art galleries and gymnasia
4.0
4.5
c) Projection rooms
5.0
—
d) Stages
5.0
4.5
e) Office rooms, kitchens and laundries
3.0
4.5
f) Dressing rooms
2.0
1.8
g) Lounges and billiards rooms
2.0
2.7
h) Toilets and bathrooms
2.0
—
j) Corridors, passages and staircases including fire escapes
4.0
4.5
k) Balconies
Same as rooms to which they give access but with a minimum of 4.0
1.5 metre run concentrated at the outer edge
m) Boiler rooms and plant rooms including weight of machinery
Table 1Concluded
(1)
(2)
(3)
(4)
vi)
Merchantile Buildings
a) Retail shops
4.0
3.6
b) Wholesale shops — to be calculated but not less than
6.0
4.5
c) Office rooms
2.5
2.7
d) Dining rooms, restaurants and cafeterias
3.0¹⁾
2.7
e) Toilets
2.0
—
f) Kitchens and laundries
3.0
4.5
g) Boiler rooms and plant rooms — to be calculated but not less than
5.0
6.7
h) Corridors, passages, staircases including fire escapes and lobbies
4.0
4.5
j) Corridors, passages, staircases subject to loads greater than from crowds, such as wheeled vehicles, trolleys and the like
5.0
4.5
k) Balconies
Same as rooms to which they give access but with a minimum of 4.0
1.5 metre run concentrated at the outer edge
vii)
Industrial Buildings⁴⁾
a) Work areas without machinery/equipment
2.5
4.5
b) Work areas with machinery/ equipment³⁾
1) Light dutyTo be calculated but not less than
5.0
4.5
2) Medium duty
4.5
3) Heavy duty
7.010.0
4.54.5
c) Boiler rooms and plant rooms — to be calculated but not less than
5.0
6.7
d) Cafeterias and dinning rooms
3.0¹⁾
2.7
e) Corridors, passages, staircases including fire escapes
4.0
4.5
f) Corridors, passages, lobbies, staircases subject to machine loads and wheeled vehicles — to be calculated but not less than
5.0
4.5
g) Kitchens
3.0
4.5
h) Toilets and bathrooms
2.0
—
viii)
Storage Buildings⁴⁾
a) Storage rooms (other than cold storage) and warehouses — to be calculated based on the bulk density of materials stored but not less than
2.4 kN/m² per metre of storage height with a minimum of 7.5 kN/m²
3.3.1.1 Load application
The uniformly distributed loads specified in Table 1 shall be applied as static loads over the entire floor area under consideration or a portion of the floor area
whichever arrangement produces critical effects on the structural elements as provided in respective design codes.
In the design of floors, the concentrated loads are
considered to be applied in the positions which produce the maximum stresses and where deflection is the main criterion in the positions which produce the maximum deflections. Concentrated load, when used for the calculation of bending and shear, are assumed to act at a point. When used for the calculation of local effects, such as, crushing or punching, they are assumed to act over an actual area of application of 0.3 m × 0.3 m.
3.3.1.2 Loads due to light partitions
In office and other buildings, where actual loads due to light partitions cannot be assessed at the time of planning the floors and the supporting structural members shall be designed to carry, in addition to other loads, uniformly distributed loads per square metre of not less than 33.33 percent of weight per metre run of finished partitions, subject to a minimum of 1 kN/m2, provided total weight of partition walls per m2 of the wall area does not exceed 1.5 kN/m2 and the total weight per metre length is not greater than 4.0 kN.
3.3.2 Reduction in Imposed Loads on Floors
3.3.2.1 For members supporting floors
Except as provided for in 3.3.2.1 (a), the following reductions in assumed total imposed loads on the floors may be made in designing columns, load bearing walls, piers, their supports and foundations.
Number of Floors (Including the Roof) to be Carried by Member Under Consideration
Reduction in Total Distributed Imposed Load on All Floors to be Carried by the Member Under Consideration Percent
(1)
(2)
1
0
2
10
3
20
4
30
5 to 10
40
Over 10
50
a) No reduction shall be made for any plant or machinery which is specifically allowed for, or for buildings for storage purposes, warehouses and garages. However, for other buildings, where the floor is designed for an imposed floor load of 5.0 kN/m2 or more, the reductions shown in 3.3.2.1 may be taken provided that the loading assumed is not less than it would have been if all the floors had been designed for 5.0 kN/m2 with no reductions.
NOTE — In case if the reduced load in the lower floor is lesser than the reduced load in the upper floor, then the reduced load of the upper floor will be adopted.
b) An example is given in Annex A illustrating
the reduction of imposed loads in a multi-storeyed building in the design of column members.
3.3.2.2 For beams in each floor level
Where a single span of beam, girder or truss supports not less than 5 0 m 2 of floor at one general level, the imposed floor load may be reduced in the design of the beams, girders or trusses by 5 percent for each 50 m2 area supported subject to a maximum reduction of 25 percent. However, no reduction shall be made in any of the following types of loads:
a) any superimposed moving load,
b) any actual load due to machinery or similar concentrated loads,
c) the additional load in respect of partition walls; and
d) any impact or vibration.
NOTE — The above reduction does not apply to beams, girdes or trusses supporting roof loads.
3.3.3 Posting of Floor Capacities
Where a floor or part of a floor of a building has been designed to sustain a uniformly distributed load exceeding 3.0 k N / m 2 and in assembly, business mercantile, industrial or storage buildings, a permanent notice in the form shown below indicating the actual uniformly distributed and/or concentrated loadings for which the floor has been structurally designed shall be posted in a conspicuous place in a position adjacent to such floor or on such part of a floor.
DESIGNED IMPOSED FLOOR LOADING
Distributed......kN/m2
Concentrated......kN
Label Indicating Designed Imposed Floor Loading
1 The lettering of such notice shall be embossed or cast suitably on a tablet whose least dimension shall not be less than 0.25 m and located not less than 1.5 m above floor level with lettering of a minimum size of 25 mm.
2 If a concentrated load or a bulk load has to occupy a definite position on the floor, the same could also be indicated in the lable.
3.4Imposed Loads on Roofs
3.4.1 Imposed Loads on Various Types of Roofs
On flat roofs, sloping roofs and curved roofs, the imposed loads due to use and occupancy of the buildings and the geometry of the types of roofs shall be as given in Table 2.
Table 2Imposed Loads on Various Types of Roofs (Clause 3.4.1)
Sl No.(1)
Type of Roof(2)
Imposed Load Measured on Plan Area(3)
Minimum Imposed Load Measured on Plan(4)
i)
Flat, sloping or curved roof with slopes up to and including 10 degrees
a) Access provided
1.5 kN/m²
3.75 kN uniformly distributed over any span of one metre width of the roof slab and 9 kN uniformly distributed over the span of any beam or truss or wall
b) Access not provided except for maintenance
0.75 kN/m²
1.9 kN uniformly distributed over any span of one metre width of the roof slab and 4.5 kN uniformly distributed over the span of any beam or truss or wall
ii)
Sloping roof with slope greater than 10°
For roof membrane sheets or purlins - 0.75 kN/m2less 0.02 kN/m2for every degree increase in slope over 10°
Subject to a minimum of 0.4 kN/m²
iii)
Curved roof with slope of line obtained by joining springing point to the crown with the horizontal, greater than 10°
(0.75 - 0.52 α²) kN/m² where α = h/l h = height of the highest point of the structure measured from its springing; and l = chord width of the roof if singly curved and shorter of the two sides if doubly curved.Alternatively, where structural analysis can be carried out for curved roofs of all slopes in a simple manner applying the laws of statistics, the curved roofs shall be divided into minimum 6 equal segments and for each segment imposed load shall be calculated appropriate to the slope of the chord of each segment as given in (i) and (ii).
Subject to a minimum of 0.4 kN/m²
NOTES
1 The loads given above do not include loads due to snow, rain, dust collection, etc. The roof shall be designed for imposed loads given above or for snow/rain load, whichever is greater.
2 For special types of roofs with highly permeable and absorbent material, the contingency of roof material increasing in weight due to absorption of moisture shall be provided for.
3.4.1.1 Roofs of buildings used for promenade or incidental to assembly purposes shall be designed for the appropriate imposed floor loads given in Table 1 for the occupancy.
3.4.2 Concentrated Load on Roof Coverings
To provide for loads incidental to maintenance, unless otherwise specified by the Engineer-in-Charge, all roof coverings (other than glass or transparent sheets made of fibre glass) shall be capable of carrying an incidental load of 0.90 kN concentrated on an area of 12.5 cm2 so placed as to produce maximum stresses in the covering. The intensity of the concentrated load may be reduced with the approval of the Engineer-in-Charge, where it is ensured that the roof coverings would not be traversed without suitable aids. In any case, the roof coverings shall be capable of carrying the loads in accordance with 3.4.1, 3.4.3, 3.4.4 and wind load.
3.4.3 Loads Due to Rain
On surfaces whose positioning, shape and drainage system are, such as, to make accumulation of rain water possible, loads due to such accumulation of water and the imposed loads for the roof as given in Table 2 shall be considered separately and the more critical of the two shall be adopted in the design.
3.4.4 Dust Loads
In areas prone to settlement of dust on roofs (example, steel plants, cement plants), provision for dust load equivalent to probable thickness of accumulation of dust may be made.
3.4.5 Loads on Members Supporting Roof Coverings
Every member of the supporting structure which is directly supporting the roof covering(s) shall be
designed to carry the more severe of the following loads except as provided in 3.4.5.1:
a) The load transmitted to the members from the roof covering(s) in accordance with 3.4.1, 3.4.3 and 3.4.4; and
b) An incidental concentrated load of 0.90 kN concentrated over a length of 12.5 cm placed at the most favourable positions on the member.
NOTE — Where it is ensured that the roofs would be traversed only with the aid of planks and ladders capable of distributing the loads on them to two or more supporting members, the intensity of concentrated load indicated in 3.4.5 (b) may be reduced to 0.5 kN with the approval of the Engineer-in-Charge.
3.4.5.1 In case of sloping roofs with slope greater than 10o, members supporting the roof purlins, such as trusses, beams, girders, etc, may be designed for twothirds of the imposed load on purlin or roofing sheets.
3.6Loading Effects Due to Impact and Vibration
The crane loads to be considered under imposed loads shall include the vertical loads, eccentricity effects induced by vertical loads, impact factors, lateral and longitudinal braking forces acting across and along the crane rails respectively.
3.6.1 Impact Allowance for Lifts, Hoists and Machinery
The imposed loads specified in 3.3.1 shall be assumed to include adequate allowance for ordinary impact conditions. However, for structures carrying loads
Table 3Horizontal Loads on Parapets, Parapet Walls and Balustrades (Clause 3.5.1)
Sl No.
Usage Area
Intensity of Horizontal Load kN/m Run
(1)
(2)
(3)
i)
Light access stairs, gangways and like not more than 600 mm wide
0.25
ii)
Light access stairs, gangways and like, more than 600 mm wide; stairways, landings, balconies and parapet walls (private and part of dwellings)
0.35
iii)
All other stairways, landings and balconies and all parapets and handrails to roofs [except those subject to overcrowding covered under (iv)]
0.75
iv)
Parapets and balustrades in place of assembly, such as theatres, cinemas, churches, schools, places of entertainment, sports and buildings and buildings likely to be overcrowded
2.25
NOTE — In the case of guard parapets on a floor of multi-storeyed car park or crash barriers provided in certain buildings for fire escape, the value of imposed horizontal load (together with impact load) may be determined.
which induce impact or vibration, as far as possible, calculations shall be made for increase in the imposed load due to impact or vibration. In the absence of sufficient data for such calculation, the increase in the imposed loads shall be as follows:
Structures
Impact Allowance, Percent, Min
a) For frames supporting lifts and hoists
100
b) For foundations, footings and piers supporting lifts and hoisting apparatus
40
c) For supporting structures and foundations for light machinery, shaft or motor units
20
d) For supporting structures and foundations for reciprocating machinery or power units
50
3.6.2 Concentrated Imposed Loads with Impact and Vibration
Concentrated imposed loads with impact and vibration which may be due to installed machinery shall be considered and provided for in the design. The impact factor shall not be less than 20 percent which is the amount allowable for light machinery.
3.6.2.1 Provision shall also be made for carrying any
concentrated equipment loads while the equipment is being installed or moved for servicing and repairing.
3.6.3 Impact Allowance for Crane Girders
For crane gantry girders and supporting columns, the impact allowances (given in informal table below) shall be deemed to cover all forces set up by vibration, shock from slipping of slings, kinetic action of acceleration, and retardation and impact of wheel loads.
Forces specified in (c) and (d) shall be considered as acting at the rail level and being appropriately transmitted to the supporting system. Gantry girders and their vertical supports shall be designed on the assumption that either of the horizontal forces in (c) and (d) may act at the same time as the vertical load.
NOTE — See [6-1(3)] for classification (Class I to IV) of cranes.
Impact Allowance for Crane Girders
Type of Load
Additional Load
a)
Vertical loads for electric overhead cranes
25 percent of maximum static loads for crane girders for all class of cranes
25 percent for columns supporting Class III and Class IV cranes.
10 percent for columns supporting Class I and Class II cranes.
No additional load for design of foundations.
b)
Vertical loads for hand operated cranes
10 percent of maximum wheel loads for crane girders only
c)
Horizontal forces transverse to rails:
1) For electric overhead cranes with trolley having rigid mast for suspension of lifted weight (such as, soaker crane, stripper crane, etc)
10 percent of weight of crab and the weight lifted by the cranes, acting on any one crane track rail, acting in either direction and equally distributed amongst all the wheels on one side of rail track
For frame analysis, this force, calculated as above, shall be applied on one side of the frame at a time in either direction.
2) For all other electric overhead cranes and hand operated cranes
5 percent of weight of crab and the weight lifted by the cranes, acting on any one crane track rail, acting in either direction and equally distributed amongst the wheels on one side of rail track
For the frame analysis, the force, calculated as above, shall be applied on one side of the frame at a time in either direction.
d)
Horizontal traction forces along the rails for overhead cranes, either electrically operated or hand operated
5 percent of all static wheel loads
3.6.3.1 Overloading factors in crane supporting structures
3.6.4 Crane Load Combinations
In the absence of any specific indications, the load combinations shall be as indicated below.
3.6.4.1 Vertical loads
In an aisle, where more than one crane is in operation or has provision for more than one crane in future, the following load combinations shall be taken for vertical loading:
a) Two adjacent cranes working in tandem with full load and with overloading according to 3.6.3.1; and
b) For long span gantries, where more than one crane can come in the span, the girder shall be designed for one crane fully loaded with overloading according to 3.6.3.1 plus as many loaded cranes as can be accommodated on the span but without taking into account overloading according to 3.6.3 (a) to give the maximum effect.
3.6.4.2 Lateral surge
For design of columns and foundations, supporting crane girders, the following crane combinations shall be considered:
a) For Single Bay Frames — Effect of one crane in the bay giving the worst effect shall be considered for calculation of surge force; and
b) For Multi-Bay Frames — Effect of two cranes working, one each in any of two bays in the cross-section to give the worst effect shall be considered for calculation of surge force.
3.6.4.3 Tractive force
a) Where one crane is in operation with no provision for future crane, tractive force from only one crane shall be taken.
b) Where more than one crane is in operation or there is provision for future crane, tractive force from two cranes giving maximum effect shall be considered.
NOTE — Lateral surge force and longitudinal tractive force acting across and along the crane rail respectively shall not be assumed to act simultaneously. However, if there is only one crane in the bay, the lateral and longitudinal forces may act together simultaneously with vertical loads.
4Wind Load
4.1 General
This clause gives wind forces and their effects (static and dynamic) that should be taken into account when designing buildings, structures and components thereof.
1 It is believed that ultimately wind load estimation will be made by taking into account the random variation of wind speed with time, but available theoretical methods have not matured sufficiently at present for use in the Section. For this reason, equivalent static load estimation which implies a steady wind speed, which has proved to be satisfactory for normal, short and heavy structures, is given in 4.5 and 4.6. However, a beginning has been made to take account of the random nature of the wind speed by requiring that the alongwind or drag load on structures which are prone to wind induced oscillations, be also determined by the gust factor method (see 4.8) and the more severe of the two estimates be taken for design.
A large majority of structures met within practice do not, however, suffer wind induced oscillations and generally do not require to be examined for the dynamic effects of wind including use of gust factor method. Nevertheless, there are various types of structures or their components, such as some tall buildings, etc, which require investigation of wind induced oscillations. In identifying and analyzing such structures 4.6 shall be followed.
2 In the case of tall structures with unsymmetrical geometry, the designs may have to be checked for torsional effects due to wind pressure.
4.1.1 Wind is air in motion relative to the surface of the earth. The primary cause of wind is traced to earth’s rotation and differences in terrestrial radiation. The radiation effects are primarily responsible for convection either upwards or downwards. The wind
generally blows horizontal to the ground at high wind speeds. Since vertical components of atmospheric motion are relatively small, the term ‘wind’ denotes almost exclusively the horizontal wind, vertical winds are always identified as such. The wind speeds are assessed with the aid of anemometers or anemographs which are installed at meteorological observatories at heights generally varying from 10 to 30 m above ground.
4.1.2 Very strong wind speeds (greater than 80 km/h) are generally associated with cyclonic storms, thunderstorms, dust storms or vigorous monsoons. A feature of the cyclonic storms over the Indian area is that they rapidly weaken after crossing the coasts and move as depressions/lows inland. The influence of a severe storm after striking the coast does not, in general, exceed about 60 km, though sometimes, it may extend even up to 120 km. Very short duration hurricanes of very high wind speeds called Kal Baisaki or Norwesters occur fairly frequently during summer months over North-Eastern India.
4.1.3 The wind speeds recorded at any locality are extremely variable and, in addition to steady wind at any time, there are effects of gusts which may last for a few seconds. These gusts cause increase in air pressure but their effect on the stability of the building may not be so important; often, gusts affect only part of the building and the increased local pressures may be more than balanced by a momentary reduction in the pressure elsewhere. Because of the inertia of the building, short period gusts may not cause any appreciable increase in stress in the main components of the building, although the walls, roof sheeting and individual cladding units (glass panels) and their supporting members, such as purlins, sheeting rails and glazing bars may be more seriously affected. Gusts can also be extremely important for the design of structures with high slenderness ratios.
4.1.4 The liability of a building to high wind pressures depends not only upon the geographical location and proximity of other obstructions to air flow but also upon the characteristics of the structure itself.
4.1.5 The effect of wind on the structure as a whole is determined by the combined action of external and internal pressures acting upon it. In all cases, the calculated wind loads act normal to the surface to which they apply.
4.1.6 Buildings shall also be designed with due attention to the effects of wind on the comfort of people inside and outside the buildings.
4.1.7 The stability calculations of the building as a whole shall be done considering the combined effect, as well as separate effects of imposed loads and wind
loads on vertical surfaces, roofs and other parts of the building above the general roof level.
4.2 Notations
The notations to be followed, unless otherwise specified in relevant clauses under wind loads, are given in Annex B.
4.3Terminology
4.3.1 For the purpose of wind loads, the following definitions shall apply.
4.3.1.1 Angle of attack — Angle between the direction of wind and a reference axis of the structure.
4.3.1.2 Breadth — Breadth means horizontal dimension of the building measured normal to the direction of wind.
4.3.1.3 Depth — Depth means the horizontal dimension of the building measured in the direction of the wind.
NOTE — Breadth and depth are dimensions measured in relation to the direction of the wind, whereas length and width are dimensions related to the plan.
4.3.1.4 Developed height
Developed height is the height of upward penetration of the velocity profile in a new terrain. At large, fetch lengths, such penetration reaches the gradient height above which the wind speed may be taken to be constant. At lesser-fetch lengths, a velocity profile of a smaller height but similar to that of the fully developed profile of that terrain category has to be taken, with the additional provision that the velocity at the top of this shorter profile equals that of the unpenetrated earlier velocity profile at that height.
4.3.1.5 Effective frontal area
The projected area of the structure normal to the direction of the wind.
4.3.1.6 Element surface area
The area of surface over which the pressure coefficient is taken to be constant.
4.3.1.7 Force coefficient
A non-dimensional coefficient such that the total wind force on a body is the product of the force coefficient, the dynamic pressure of the incident design wind speed and the reference area over which the force is required.
NOTE — When the force is in the direction of the incident wind, the non-dimensional coefficient will be called as drag coefficient. When the force is perpendicular to the direction of incident wind the non-dimensional coefficient will be called as ‘lift coefficient’.
4.3.1.8 Ground roughness
The nature of the earth’s surface as influenced by small scale obstructions such as trees and buildings (as distinct from topography) is called ground roughness.
4.3.1.9 Gust
A positive or negative departure of wind speed from its mean value, lasting for not more than say 2 min over a specified interval of time.
4.3.1.10 Peak gust
Peak gust or peak gust speed is the wind speed associated with the maximum amplitude.
4.3.1.11 Fetch length
Fetch length is the distance measured along the wind from a boundary at which a change in the type of terrain occurs. When the changes in terrain types are encountered (such as the boundary of a town or city, forest, etc), the wind profile changes in character but such changes are gradual and start at ground level, spreading or penetrating upwards with increasing fetch length.
4.3.1.12 Gradient height
Gradient height is the height above the mean ground level at which the gradient wind blows as a result of balance among pressure gradient force, coriolis force and centrifugal force. For the purpose of this Section, the gradient height is taken as the height above the mean ground level above which the variation of wind speed with height need not be considered.
4.3.1.13 Mean ground level
The mean ground level is the average horizontal plane of the area enclosed by the boundaries of the structure.
4.3.1.14 Pressure coefficient
Pressure coefficient is the ratio of the difference between the pressure acting at a point on a surface and the static pressure of the incident wind to the design wind pressure, where the static and design wind pressure are determined at the height of the point considered after taking into account the geographical location, terrain conditions and shielding effect. The pressure coefficient is also equal to [ 1 - ( V p / V z ) 2 ] , where V p is the actual wind speed at any point on the structure at a height corresponding to that of V z .
NOTE — Positive sign of the pressure coefficient indicates pressure acting towards the surface and negative sign indicates pressure acting away from the surface.
4.3.1.15 Return period
Return period is the number of years, the reciprocal of which gives the probability of extreme wind exceeding a given wind speed in any one year.
4.3.1.16 Shielding effect
Shielding effect or shielding refers to the condition where wind has to pass along some structure(s) or structural element(s) located on the upstream wind side, before meeting the structure or structural element under consideration. A factor called ‘shielding factor’ is used to account for such effects in estimating the force on the shielded structures.
4.3.1.17 Suction
Suctions means pressure less than the atmospheric (static) pressure and is taken to act away from the surface.
4.3.1.18 Solidity ratio
Solidity ratio is equal to the effective area (projected area of all the individual elements) of a frame normal to the wind direction divided by the area enclosed by the boundary of the frame normal to the wind direction.
NOTE — Solidity ratio is to be calculated for individual frames.
4.3.1.19 Terrain category
Terrain category means the characteristics of the surface irregularities of an area which arise from natural or constructed features. The categories are numbered in increasing order of roughness.
4.3.1.20 Velocity profile
The variation of the horizontal component of the atmospheric wind speed at different heights above the mean ground level is termed as velocity profile.
4.3.1.21 Topography
The nature of the earth’s surface as influenced by the hill and valley configurations.
4.4Wind Speed and Pressure
4.4.1 Nature of Wind in Atmosphere
In general, wind speed in the atmospheric boundary layer increases with height from zero at ground level to a maximum at a height called the gradient height. There is usually a slight change in direction (Ekman effect) but this is ignored in the Section. The variation with height depends primarily on the terrain conditions. However, the wind speed at any height never remains constant and it has been found convenient to resolve its instantaneous magnitude into an average or mean value and a fluctuating component around this average value. The average value depends on the averaging time employed in analyzing the meteorological data and this averaging time varies from a few seconds to several minutes. The magnitude of the fluctuating component of the wind speed, which is called as gust, depends on the averaging time. In general, smaller the
averaging interval, greater is the magnitude of the gust speed.
4.4.2 Basic Wind Speed
Figure 1 gives basic wind speed map of India, as applicable to 10 m height above mean ground level for 10 m height above mean ground level for different zones of the country. Basic wind speed is based on peak gust velocity averaged over a short time interval of about 3 s and corresponds to mean heights above ground level in an open terrain (Category 2). Basic wind speeds presented in Fig. 1 have been worked out for a 50 year return period. Basic wind speed for some important cities/towns is also given in Annex C.
4.4.3 Design Wind Speed (V )
The basic wind speed ( V b ) for any site shall be obtained from Fig. 1 and shall be modified to include the following effects to g e t V z , design wind speed at any height for the chosen structure.
a) risk level;
b) terrain roughness, height and size of structure; and
c) local topography.
It can be mathematically expressed as follows:
V z = V b k ₁ k ₂ k ₃
where
V = design of wind speed at any height z in m/s;
V = basic wind speed in m/s (Fig. 1);
k = probability factor (risk coefficient) (4.4.3.1);
k = terrain, height and structure size factor (4.4.3.2); and
k = topography factor (4.4.3.3)
NOTE — Design wind speed up to 10 m height from mean ground level shall be considered constant.
4.4.3.1 Risk coefficient (k1)
Figure 1 gives basic wind speeds for terrain Category 2 as applicable at 10 m above ground level based on 50 year mean return period. The suggested life period to be assumed in design and the corresponding k 1 factors for different classes of structure for the purpose of design is given in Table 4. In the design of all buildings and structures, a regional basic wind speed having a mean return period of 50 years shall be used except as specified in the note of Table 4.
4.4.3.2 Terrain, height and structure size factor (k2)
a) Terrain — Selection of terrain categories shall be made with due regard to the effect of the obstruction which constitute the ground surface roughness. The terrain category used in the
The territorial waters of India extend into the sea to a distance of twelve nautical miles measured from the appropriate base line. The boundary of Meghalaya shown on this map is as interpreted from the North-Eastern Areas (Reorganisation) Act, 1971, but has yet to be verified. Responsibility for correctness of internal details shown on the map rests with the publisher. The state boundaries between Uttaranchal & Uttar Pradesh, Bihar & Jharkhand and Chhatisgarh & Madhya Pradesh have not been verified by Governments concerned.
Based upon Survey of India Outline Map printed in 1993.
FIG. 1 BASIC WIND SPEED IN m/s (BASED ON 50-YEARS RETURN PERIOD)
Table 4Risk Coefficients for Different Classes of Structures in Different Wind Speed Zones (Clause 4.4.3.1)
Class of Structure
Mean Probable Design Life of Structure in Years
k₁ Factor for Basic Wind Speed (m/s) of
33(3)
39(4)
44(5)
47(6)
50(7)
55(8)
4.4.3.3 Topography (k3, factor)
The basic wind speed V b given in Fig. 1 takes account of the general level of the site above sea level. This does not allow for local topographic features, such as hills, valleys, cliffs, escarpments or ridges, which can significantly affect wind speed in their vicinity. The effect of topography is to accelerate wind near the summits of hills or crests of cliffs, escarpments or ridges and decelerate the wind in valleys or near the foot of cliffs, steep escarpments or ridges.
The effect of topography will be significant at a site when the upwind slope is greater than about 3 ° , and below that the value of k 3 may be taken to be equal to 1.0. The value of k 3 is confined in the range of 1.0 to 1.36 for slopes greater than 3°. A method of evaluating the value of k 3 for slope greater than 3 ° is given in Annex E. It may be noted that the value of k 3 varies with height above ground level with a maximum near the ground, and reducing to 1.0 at higher levels.
4.4.4 Design Wind Pressure
The design wind pressure at any height above mean ground level shall be obtained by the following relationship between wind pressure and wind velocity:
p z = 0. 6 V z ²
where
p = design wind pressure in N / m 2 at height Z, and
V z = design wind velocity in m / s at height Z.
NOTE — The coefficient 0.6 (in SI units) in the above formula depends on a number of factors, and mainly on the atmospheric pressure and air temperature. The value chosen corresponds to the average appropriate Indian atmospheric conditions.
4.4.5 Offshore Wind Velocity
Cyclonic storms form far way from the sea coast and gradually reduce in speed as they approach the sea coast. Cyclonic storms generally extend up to about 60 km inland after striking the coast. Their effect on land is already reflected in basic wind speeds specified in Fig. 1. The influence of wind speed off the coast up to a distance of about 200 km may be taken as 1.15 times the value on the nearest coast in the absence of any definite wind data.
4.5Wind Pressure and Forces on Buildings/ Structure
4.5.1 General
The wind load on a building shall be calculated for:
a) the building as a whole;
b) individual structural elements as roofs and walls; and
c) individual cladding units including glazing and their fixings.
4.5.2 Pressure Coefficients
The pressure coefficients are always given for a particular surface or part of the surface of a building. The wind load acting normal to a surface is obtained by multiplying the area of that surface or its appropriate portion by the pressure coefficient ( C p ) ; and the design wind pressure at the height of the surface from the ground. The average values of these pressure coefficients for some building shapes are given in 4.5.2.2 and 4.5.2.3.
Average values of pressure coefficients are given for critical wind directions in one or more quadrants. In order to determine the maximum wind load on the building, the total load should be calculated for each of the critical directions shown from all quadrants.
Where considerable variation of pressure occurs over a surface, it has been sub-divided and mean pressure coefficients given for each of its several parts.
In addition, areas of high local suction (negative pressure concentration) frequently occurring near the edges of walls and roofs are separately shown. Coefficients for the local effects should only be used for calculation of forces on these local areas affecting roof sheeting, glass panels and individual cladding units including their fixtures. They should not be used for calculating force on entire structural elements such as roof, walls or structure as a whole.
1 The pressure coefficients given in the different tables have been obtained mainly from measurements on models in wind tunnels, and the great majority of data available have been obtained in conditions of relatively smooth flow. Where sufficient field data exist as in the case of rectangular buildings, values have been obtained to allow for turbulent flow.
2 In recent years, wall glazing and cladding design has been a source of major concern. Although of less consequence than collapse of the main structures, damage to glass can be hazardous and cause considerable financial losses.
3 For pressure coefficients for structures not covered herein, reference may be made to specialist literature on the subject or advise may be sought from specialists in the subject.
4.5.2.1 Wind load on individual members
When calculating the wind load on individual structural elements such as roofs and walls, and individual cladding units and their fittings, it is essential to take account of the pressure difference between opposite faces of such elements or units. For clad structures, it is, therefore, necessary to know the internal pressure as well as external pressure. Then the wind load, F (in N) acting in a direction normal to the individual structural element or cladding unit is:
F = (C pe - C pi) A p d
where
C pe = external pressure coefficient;
C pi = internal pressure coefficient;
A = surface area of structural element or cladding unit in m2; and
p d = design wind pressure in N / m ²
1 If the surface design pressure varies with height, the surface areas of the structural element may be sub-divided so that the specified pressures are taken over appropriate areas.
2 Positive wind load indicates the force acting towards the structural element and negative away from it.
4.5.2.2 External pressure coefficients
a) Walls — The average external pressure coefficient for the walls of clad buildings of
rectangular plan shall be as given in Table 7. In addition, local pressure concentration coefficients are also given.
b) Pitched Roofs of Rectangular Clad Buildings — The average external pressure coefficients and pressure concentration coefficients for pitched roofs of rectangular clad building shall be as given in Table 8. Where no pressure concentration coefficients are given, the average coefficients apply. The pressure coefficients on the underside of any overhanging roof shall be taken in accordance with 4.5.2.2 (g).
1 The pressure concentration shall be assumed to act outward (suction pressure) at the ridges, eaves, cornices and 90° corners of roofs.
2 The pressure concentration shall not be included with the net external pressure when computing overall loads.
c) Monoslope Roofs of Rectangular Load Buildings — The average pressure coefficient and pressure concentration coefficient for monoslope (lean-to) roofs of rectangular clad buildings shall be as given in Table 9.
d) Canopy Roofs with ¼ < h/w < 1 and 1 < L / w < 3 — The pressure coefficients are given in Tables 10 and 11 separately for monopitch and double pitch canopy roofs, such as open-air parking garages, shelter areas, outdoor areas, railway platforms, stadiums and theatres. The coefficients take account of the combined effect of the wind exerted on and under the roof for all wind directions; the resultant is to be taken normal to the canopy. Where the local coefficients overlap the greater of the two given values should be taken. However, the effect of partial closures of one side and or both sides, such as those due to trains, buses and stored materials shall be foreseen and taken into account.
The solidity ratio ø is equal to the area of obstruction under the canopy divided by the gross area under the canopy, both areas normal to the wind direction. = 0 represents a canopy with no obstructions underneath. ø = 1 represents the canopy fully blocked with contents to the downwind eaves. Values of C p for intermediate solidities may be linearly interpolated between these two extremes, and apply upwind of the position of maximum blockage only. Downwind of the position of maximum blockage the coefficients for = 0 may be used.
In addition to the pressure forces normal to
Table 7External Pressure Coefficients ( C p e ) for Walls of Rectangular Clad Buildings [Clause 4.5.2.2 (a)]
Building Height Ratio
Building Plan Ratio
Elevation
Plan
Wind Angle θ Degree
C for Surface
4.5.2.3 Internal pressure coefficients
Internal air pressure in a building depends upon the degree of permeability of the cladding to the flow of air. The internal air pressure may be positive or negative depending on the direction of flow of air in relation to the openings in the buildings.
a) In the case of buildings where the claddings permit the flow of air with openings not more than about 5 percent of the wall areas but where there are no large openings, it is necessary to consider the possibility of the internal pressure being positive or negative.
(h : b :l = 0.8: 1: 2.2)
Table 24 Pressure Coefficients at Top and Bottom Roof of Grandstands Open Three Sides (Roof = 5°)
[Clause 4.5.2.2 (m)]
Front and Back of Wall
θ
J
K
L
M
0o
+0.9
-0.5
+0.9
-0.5
45o
+0.8
-0.6
+0.4
-0.4
135o
-1.1
+0.6
-1.0
+0.4
180o
-0.3
+0.9
-0.3
+0.9
60o
Mw - Cp of K = -1.0
60o
Mw - Cp of J = +1.0
( Shaded area to scale )
Top and Bottom of Roof
θ
A
B
C
D
E
F
G
H
0o
-1.0
+0.9
-1.0
+0.9
-0.7
+0.9
+0.7
+0.9
45o
-1.0
+0.7
-0.7
+0.4
4.5.3 Force Coefficients
The value of force coefficients apply to a building or structure as a whole, and when multiplied by the effective frontal area, A e of the building or structure and by design wind pressure, p d give the total wind load on that particular building or structure.
F = CfAepd
where F is the force acting in a direction specified in the respective tables and C f is the force coefficient for the building.
1 The value of the force coefficient differs for the wind acting on different faces of a building or structure. In order to
FIG. 3 LARGE OPENING IN BUILDINGS (VALUES OF COEFFICIENT OF INTERNAL PRESSURE) (WITH TOP CLOSED)
determine the critical load, the total wind load should be calculated for each wind direction.
2 If surface design pressure varies with height, the surface area of the building/structure may be sub-divided so that specified pressure are taken over appropriate areas.
3 In tapered buildings/structures, the force coefficients shall be applied after sub-dividing the building/structure into suitable number of strips and the load on each strip calculated individually, taking the area of each strip as A .
4 Force coefficients for structures not covered herein, reference may be made to specialist literature on the subject or advise may be sought from specialists in the subject.
4.5.3.1 Frictional drag
In certain buildings of special shape, a force due to frictional drag shall be taken into account, in addition to those loads specified in 4.5.2. For rectangular clad buildings, this addition is necessary only where the ratio d/h or d/b is greater than 4. The frictional drag force, F ′ in the direction or the wind given by the following formulae:
If h ≤ b, F ′ = C f′ (d - 4 h) b p d + C f′ (d - 4 h) 2 h p d
If h > b, F ′ = C f′ (d - 4 b) b p d + C f′ (d - 4 b) 2 h p d
The first term in each case gives the drag on the roof and the second on the walls. The value of C f ′ has the following values:
C'= 0.01 for smooth surfaces without corrugations or ribs across the wind direction;
C'= 0.02 for surfaces with corrugations or ribs across the wind direction;
C f ′ = 0.04 for surfaces with ribs across the wind direction.
4.6Dynamic Effects
4.6.1 General
Flexible slender structures and structural elements shall be investigated to ascertain the importance of wind induced oscillations for excitations along and across the direction of wind.
In general the following guidelines may be used for examining the problems of wind induced oscillations:
a) Buildings and closed structures with a height to minimum lateral dimension ratio of more than about 5.0; or
b) Buildings and structures whose natural frequency in the first mode is less than 1.0 Hz. Any building or structure which satisfies either of the above two criteria shall be examined for dynamic effects of wind.
1 The fundamental natural period (T ), in seconds, of a moment-resisting frame building without brick infil panels and of all other buildings including with brick infil panels may be estimated in accordance with 5.4.6. 2 If preliminary studies indicate that wind-induced oscillations are likely to be significant, investigations should be persued with the aid of analytical methods or, if necessary, by means of wind tunnel tests on models.
3 Cross wind motions may be due to the lateral gustiness of the wind, unsteady wake flow (for example, vortex shedding), negative aerodynamic damping or to a combination of these effects. These cross-wind motions can become critical in the design of tall building structures.
4 Motions in the direction of the wind (also known as buffeting) are caused by fluctuating wind force associated with gusts. The excitations depend on the gust energy available at the resonant frequency.
a) Values of C versus a / b for h 1 6 ≥ 1
b) Values of C versus a / b for h / b < 1
FIG. 4 FORCE COEFFICIENT FOR RECTANGULAR CLAD BUILDING IN UNIFORM FLOW
Table 26Force Coefficients C for Clad Buildings of Uniform Section (Acting in the Direction of Wind) [Clause 4.5.3.2 (a)]
Plan Shape
V₂b m²/s
Cf for Height/Breadth Ratio
Up to 1/2
1
2
5
10
20
∞
(see also Annex E)
All surfaces
<6
0.7
0.7
0.7
0.8
0.9
1.0
1.2
Rough or with projections
≥6
Smooth
≥6
0.5
0.5
0.5
0.5
0.5
0.6
0.6
Ellipse b/d = 1/2
<10
0.5
0.5
0.5
0.5
0.6
0.6
0.7
≥10
0.2
0.2
0.2
0.2
0.2
0.2
0.2
Ellipse b/d = 2
<8
0.8
0.8
0.9
1.0
1.1
1.3
1.7
≥8
0.8
0.8
0.9
1.0
1.1
1.3
1.5
b/d = 1r/b = 1/3
<4
0.6
0.6
0.6
0.7
0.8
0.8
1.0
≥4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
b/d = 1r/b = 1/6
<10
0.7
0.8
0.8
0.9
1.0
1.0
1.3
≥10
0.5
0.5
0.5
0.5
0.6
0.6
0.6
b/d = 1/2r/b = 1/2
<3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
≥3
0.2
0.2
0.2
0.2
0.3
0.3
0.3
All values
0.5
0.5
0.5
0.5
0.6
0.6
0.7
b/d = 2r/b = 1/12
All values
0.9
0.9
1.0
1.1
1.2
1.5
1.9
Table 26Continued
Plan Shape
V₂b m²/s
Cf for Height/Breadth Ratio
Up to 1/2
1
2
5
10
20
∞
<6
0.7
0.8
0.8
0.9
1.0
1.2
1.6
≥6
0.5
0.5
0.5
0.5
0.5
0.6
0.6
<10
0.8
0.8
0.9
1.0
1.1
1.3
1.5
≥10
0.5
0.5
0.5
0.5
0.5
0.6
0.6
All values
0.9
0.9
0.9
1.1
1.2
1.3
1.6
r/a = 1/48
All values
0.9
0.9
0.9
1.1
1.2
1.3
1.6
r/b = 1/4
<11
0.7
0.7
0.7
0.8
0.9
1.0
1.2
≥11
0.4
0.4
0.4
0.4
0.5
0.5
0.5
r/b = 1/12
All values
0.8
0.8
0.8
1.0
1.1
1.2
1.4
All values
0.7
0.7
0.8
0.9
1.0
1.1
1.3
Table 26Concluded
Plan Shape
Vzb m²/s
Cf for Height/Breadth Ratio
Up to 1/2
1
2
5
10
20
∞
< 8
0.7
0.7
0.8
0.9
1.0
1.1
1.3
≥ 8
0.4
0.4
0.4
0.4
0.5
0.5
0.5
All values
1.2
1.2
1.2
1.4
1.6
1.7
2.1
12 sided polygon
< 12
0.7
0.7
0.8
0.9
1.0
1.1
1.3
≥ 12
0.7
0.7
0.7
0.7
0.8
0.9
1.1
Octagon
All values
1.0
1.0
1.1
1.2
1.2
1.3
1.4
Hexagon
All values
1.0
1.1
1.2
1.3
1.4
1.4
1.5
NOTE — Structures that, because of their size and the design wind velocity, are in the supercritical flow regime may need further calculation to ensure that the greatest loads do not occur at some wind speed below the maximum when the flow will be subcritical.
The coefficients are for buildings without projections, except where otherwise shown. In this table V b is used as an indication of the airflow regime.
Table 27 Force Coefficients for Low Walls or Hoardings (<15 m High) [Clause 4.5.3.2 (b)]
(Wind normal to face)
Width to Height Ratio, b/h
Drag Coefficient, Cf
Wall above ground
Wall on ground
From 0.5 to 6
From 1 to 12
1.2
10
20
1.3
16
32
1.4
20
40
1.5
40
80
1.7
60
120
1.8
80 or more
160 more 20
2.0
SIDE ELEVATION
DESCRIPTION OF SHAPE
C<sub>f</sub>
CIRCULAR DISC
1.2
HEMISPHERICAL BOWL
1.4
HEMISPHERICAL BOWL
0.4
HEMISPHERICAL SOLID
-1.2
SPHERICAL SOLID
0.5 FOR V D < 70.2 FOR V D ≥ 7
FIG. 6 FORCE COEFFICIENTS FOR SOLID SHAPES MOUNTED ON A SURFACE
5 The wake shed from an upstream body may intensify motions in the direction of the wind, and may also effect crosswind motions.
6 The designer must be aware of the following three forms of wind induced motion which are characterized by increasing amplitude of oscillation with increase of wind speed.
a) Galloping — Galloping is transverse oscillations of some structures due to the development of aerodynamic forces which are in phase with the motion. It is characterized by the progressively increasing amplitude of transverse vibration with increase of wind speed. The cross-sections which are particularly prone to this type of excitation include the following:
i) All structures with non-circular cross-sections, such as triangular, square, polygons, as well as angles, crosses and T-sections.
ii) Twisted cables and cables with ice encrustations.
b) Flutter — Flutter is unstable oscillatory motion of a structure due to coupling between aerodynamic force and the elastic deformation of the structure. Perhaps the most common form is the oscillatory motion due to combined bending and torsion. Although oscillatory motions in each degree of freedom may be dampled, instability can set in due to energy transfer from one mode of oscillation to another, and the structure is seen to execute sustained or divergent oscillations with a type of motion which is a combination of the individual modes of motion. Such energy transfer takes place when the natural frequencies of the modes, taken individually, are close to each other (ratio being typically less than 2.0). Flutter can set in at wind speeds much less than those required for exciting the individual modes of motion. Long span suspension bridge decks or any member of a structure with large values of d/t (where d is the depth of a structure or structural member parallel to wind stream and t is the least lateral dimension
of a member) are prone to low speed flutter. Wind tunnel testing is required to determine critical flutter speeds and the likely structural response. Other types of flutter are single degree of freedom stall flutter, torsional flutter etc.
c) Ovalling — Thin walled structures with open ends at one or both ends, such as oil storage tanks, and natural draught cooling towers, in which the ratio of the diameter of minimum lateral dimension to the wall thickness is of the order of 100 or more, are prone to ovalling oscillations. These oscillations are characterized by periodic radial deformation of the hollow structure.
7 Buildings and structures that may be subjected to serious wind excited oscillations require careful investigation. It is to be noted that wind induced oscillations may occur at wind speeds lower than the static design wind speed for the location.
8 Analytical methods for determining dynamic response of structures to wind loading can be found in the following publications:
b) ‘Wind Engineering in the Eighties’. Construction Industry Research and Information Association, 1981, London.
c) ‘Wind Effects on Structures’ by E Simiu and R.H. Scanlan. Johan Wiley and Sons, New York, 1978.
d) Supplement to the National Building Code of Canada, 1980. NRCC, No. 17724. National Research Council of Canada, Ottawa, 1980.
e) Wind Forces on Structures by Peter Sachs. Pergamon Press.
f) Flow Induced Vibration by Robert D. Clevins. Von Nostrand Reinfold Co.
9 In assessing wind loads due to such dynamic phenomenon as galloping, flutter and ovalling, if the required information is not available either in the references of Note 8 or other literature, specialist advice shall be sought, including experiments on models in wind tunnels.
4.6.2 Motions Due to Vortex Shedding
4.6.2.1 Slender structures — For a structure, the shedding frequency, η shall be determined by the following formula:
η=bSVd
where
S = Strouhal number,
V d = design wind velocity, and
b = The breadth of a structure or structural members in the horizontal plane normal to the wind direction.
a) Circular Structures — For structures circular in cross-section:
S = 0.20 for b V z not greater than 7, and S = 0.25 for b V z greater than 7.
b) Rectangular Structures — For structures of rectangular cross-section:
S = 0. 1 5 for all values of b V .
3.5Imposed Horizontal Loads on Parapets and Balustrades
3.5.1 Parapets, Parapet Walls and Balustrades
Parapets, parapet walls and balustrades, together with the members which give them structural support, shall be designed for the minimum loads given in Table 3. These are expressed as horizontal forces acting at handrail or coping level. These loads shall be considered to act vertically also but not simultaneously with the horizontal forces. The values given in Table 3 are minimum values and where values for actual loadings are available, they shall be used instead.
3.5.2 Grandstands and the Like
Grandstands, stadia, assembly platforms, reviewing stands and the like shall be designed to resist a horizontal force applied to seats of 0.35 kN per linear metre along the line of seats and 0.15 kN per linear metre perpendicular to the line of the seats. These loadings need not be applied simultaneously. Platforms without seats shall be designed to resist a minimum horizontal force of 0.25 kN/m2 of plan area.
5Seismic Load
5.0 This clause deals with assessment of seismic loads on various structures and earthquake resistant design of buildings. (For the purpose of this clause the symbols given at Annex G are applicable).
5.1 Terminology for Earthquake Engineering
5.1.1 For the purpose of this standard, the following definitions shall apply which are applicable generally to all structures:
NOTE — For the definitions of terms pertaining to soil mechanics and soil dynamics references may be made to Part 6 ‘Structural Design, Section 2 Soils and Foundations’.
5.1.2 Closely-Spaced Modes
Closely-spaced modes of a structure are those of its natural modes of vibration whose natural frequencies differ from each other by 10 percent or less of the lower frequency.
5.1.3 Critical Damping
The damping beyond which the free vibration motion will not be oscillatory.
5.1.4 Damping
The effect of internal friction, imperfect elasticity of material, slipping, sliding etc, in reducing the amplitude of vibration and is expressed as a percentage of critical damping.
5.1.5 Design Acceleration Spectrum
Design acceleration spectrum refers to an average smoothened plot of maximum acceleration as a function of frequency or time period of vibration for a specified damping ratio for earthquake excitations at the base of a single degree of freedom system.
5.1.6 Design Basis Earthquake (DBE)
It is the earthquake which can reasonably be expected to occur at least once during the design life of the structure.
It is a horizontal acceleration coefficient that shall be used for design of structures.
5.1.8 Design Lateral Force
It is the horizontal seismic force prescribed by this standard, that shall be used to design a structure.
5.1.9 Ductility
Ductility of a structure, or its members, is the capacity to undergo large inelastic deformations without significant loss of strength or stiffness.
FIG. 8 BACKGROUND FACTOR, B
FIG. 9 GUST ENERGY FACTOR, E
FIG. 10 SIZE REDUCTION FACTOR, S
5.1.10 Epicentre
The geographical point on the surface of earth vertically above the focus of the earthquake.
5.1.11 Effective Peak Ground Acceleration (EPGA)
It is 0.4 times the 5 percent damped average spectral acceleration between period 0.1 to 0.3 s. This shall be taken as zero period acceleration (ZPA).
5.1.12 Floor Response Spectra
Floor response spectra is the response spectra for a time history motion of a floor. This floor motion time history is obtained by an analysis of multi-storey building for appropriate material damping values subjected to a specified earthquake motion at the base of structure.
5.1.13 Focus
The originating earthquake source of the elastic waves inside the earth which cause shaking of ground due to earthquake.
5.1.14 Importance Factor (I)
It is a factor used to obtain the design seismic force depending on the functional use of the structure, characterised by hazardous consequences of its failure, its post-earthquake functional need, historic value, or economic importance.
5.1.15 Intensity of Earthquake
The intensity of an earthquake at a place is a measure of the strength of shaking during the earthquake, and is indicated by a number according to the modified Mercalli Scale or M.S.K. scale of Seismic Intensities (see Annex H).
5.1.16 Liquefaction
Liquefaction is a state in saturated cohesionless soil wherein the effective shear strength is reduced to negligible value for all engineering purpose due to pore pressure caused by vibrations during an earthquake when they approach the total confining pressure. In this condition the soil tends to behave like a fluid mass.
5.1.17 Lithological Features
The nature of the geological formation of the earth‘s crust above bed rock on the basis of such characteristics as colour, structure, mineralogical composition and grain size.
5.1.18 Magnitude of Earthquake (Richter’s Magnitude)
The magnitude of earthquake is a number, which is a measure of energy released in an earthquake. It is defined as logarithm to the base 10 of the maximum trace amplitude, expressed in microns, which the
standard short-period torsion seismometer (with a period of 0.8 s, magnification 2 800 and damping nearly critical) would register due to the earthquake at an epicentral distance of 100 km.
5.1.19 Maximum Considered Earthquake (MCE)
The most severe earthquake effects considered by this Code.
5.1.20 Modal Mass (Mk)
Modal mass of a structure subjected to horizontal or vertical, as the case may be, ground motion is a part of the total seismic mass of the structure that is effective in mode k of vibration. The modal mass for a given mode has a unique value irrespective of scaling of the mode shape.
5.1.21 Modal Participation Factor (Pk)
Modal participation factor of mode k of vibration is the amount by which mode k contributes to the overall vibration of the structure under horizontal and vertical earthquake ground motions. Since the amplitudes of 95 per cent mode shapes can be scaled arbitrarily, the value of this factor depends on the scaling used for mode shapes.
5.1.22 Modes of Vibration (see 5.1.25)
5.1.23 Mode Shape Coefficient (ϕik)
When a system is vibrating in normal mode k , at any particular instant of time, the amplitude of mass i expressed as a ratio of the amplitude of one of the masses of the system, is known as mode shape coefficient ( φ i k )
5.1.24 Natural Period ( T)
Natural period of a structure is its time period of undamped free vibration.
5.1.24.1 Fundamental natural period (T1)
It is the first (longest) modal time period of vibration.
5.1.24.2 Modal natural period (Tk)
The modal natural period of mode k is the time period of vibration in mode k.
5.1.25 Normal Mode
A system is said to be vibrating in a normal mode when all its masses attain maximum values of displacements and rotations simultaneously, and pass through equilibrium positions simultaneously.
5.1.26 Response Reduction Factor (R)
It is the factor by which the actual base shear force, that would be generated if the structure were to remain elastic during its response to the design basis
earthquake (DBE) shaking, shall be reduced to obtain the design lateral force.
5.1.27 Response Spectrum
The representation of the maximum response of idealized single degree freedom systems having certain period and damping, during earthquake ground motion. The maximum response is plotted against the undamped natural period and for various damping values, and can be expressed in terms of maximum absolute acceleration, maximum relative velocity, or maximum relative displacement.
5.1.28 Seismic Mass
It is the seismic weight divided by acceleration due to gravity.
5.1.29 Seismic Weight (W)
It is the total dead load plus appropriate amounts of specified imposed load.
5.1.30 Structural Response Factors (Sa/g)
It is a factor denoting the acceleration response spectrum of the structure subjected to earthquake ground vibrations, and depends on natural period of vibration and damping of the structure.
5.1.31 Tectonic Features
The nature of geological formation of the bed rock in the earth’s crust revealing regions characterized by structural features, such as dislocation, distortion, faults, folding, thrusts, volcanoes with their age of formation, which are directly involved in the earth movement or quake resulting in the above consequences.
5.1.32 Time History Analysis
It is an analysis of the dynamic response of the structure attach increment of time, when its base is subjected to a specific ground motion time history.
5.1.33 Zone Factor (Z)
It is a factor to obtain the design spectrum depending on the perceived maximum seismic risk characterized by maximum considered earthquake (MCE) in the zone in which the structure is located. The basic zone factors included in this standard are reasonable estimate of effective peak ground acceleration.
5.1.34 Zero Period Acceleration (ZPA)
It is the value of acceleration response spectrum for period below 0.03 s (frequencies above 33 Hz).
4.7Gust Factor (GF) or Gust Effectiveness Factor (GEF) Method
4.7.1 Application
Only the method of calculating load along wind or drag load by using gust factor method is given in the section since methods for calculating load across-wind or other components are not fully matured for all types of structures. However, it is permissible for a designer to use gust factor method to calculate all components of load on a structure using any available theory. However, such a theory must take into account the random nature of atmospheric wind speed.
NOTE — It may be noted that investigations for various types of wind induced oscillations out lined in 4.6 are in no way related to the use of gust factor method given in 4.7. Although study of 4.6 is needed for using gust factor method.
4.7.2 Hourly Mean Wind
Use of the existing theories of gust factor method require a knowledge of the maximum of the wind speeds averaged over one hour at a particular site. Hourly mean wind speeds at different heights over different terrains is given in Table 28.
NOTE — It must also be recognized that the ratio of hourly mean wind (HMW) to peak gust (PG) given in Table 28 may not be obtainable in India since extreme wind occurs mainly due to cyclones and thunderstorms, unlike in UK and Canada where the mechanism is fully developed pressure system. However Table 28 may be followed at present for the estimation of the hourly mean wind speed till more reliable values become available.
Table 28Hourly Mean Wind Speed Factor k z in Different Terrains for Different Heights (Clause 4.7.2)
Heightm(1)
Terrain
Category 1(2)
Category 2(3)
Category 3(4)
Category 4(5)
10
0.78
0.67
0.50
0.24
15
0.82
0.72
0.55
0.24
20
0.85
0.75
0.59
0.24
30
0.88
0.79
0.64
0.34
50
0.93
0.85
0.70
0.45
100
0.99
0.92
0.79
0.57
150
1.03
0.96
0.84
0.64
200
1.06
1.00
0.88
0.68
250
1.08
1.02
0.91
0.72
300
1.09
1.04
0.93
0.74
350
1.11
1.06
0.95
0.77
400
1.12
1.07
0.97
0.79
450
1.13
1.08
0.98
0.81
500
1.14
1.09
0.99
0.82
4.7.2.1 Variation of hourly mean wind speed with height
The variation of hourly mean wind speed with height shall be calculated as follows:
Vz=Vb
4.7.3 Along Wind Load
Along wind load on a structure on a strip area ( A e ) at any height (Z) is given by:
Fz=CfAe
5.3General Principles and Design Criteria
5.3.1 General Principles
5.3.1.1 Ground motion
The characteristics (intensity, duration, etc) of seismic ground vibrations expected at any location depends upon the magnitude of earthquake, its depth of focus, distance from the epicentre, characteristics of the path through which the seismic waves travel, and the soil strata on which the structure stands. The random earthquake ground motions, which cause the structure to vibrate, can be resolved in any three mutually perpendicular directions. The predominant direction of ground vibration is usually horizontal.
Earthquake-generated vertical inertia forces are to be considered in design unless checked and proven by specimen calculations to be not significant. Vertical acceleration should be considered in structures with large spans, those in which stability is a criterion for design, or for overall stability analysis of structures. Reduction in gravity force due to vertical component of ground motions can be particularly detrimental in cases of prestressed horizontal members and of cantilevered members. Hence, special attention should be paid to the effect of vertical component of the ground motion on prestressed or cantilevered beams, girders and slabs.
5.3.1.2 The response of a structure to ground vibrations is a function of the nature of foundation soil, materials, form, size and mode of construction of structures; and the duration and characteristics of ground motion. This standard specifies design forces for structures standing on rocks or soils which do not
settle, liquefy or slide due to loss of strength during ground vibrations.
5.3.1.3 The design approach adopted in this standard is to ensure that structures possess at least a minimum strength to withstand minor earthquakes (<DBE), which occur frequently, without damage; resist moderate earthquakes (DBE) without significant structural damage though some non-structural damage may occur; and aims that structures withstand a major earthquake (MCE) without collapse. Actual forces that appear on structures during earthquakes are much greater than the design forces specified in this Code. However, ductility, arising from inelastic material behaviour and detailing, and overstrength, arising from the additional reserve strength in structures over and above the design strength, are relied upon to account for this difference in actual and design lateral loads.
Reinforced and prestressed concrete members shall be suitably designed to ensure that premature failure due to shear or bond does not occur, subject to the provisions of Part 6 ‘Structural Design, Section 5 Concrete’. Provisions for appropriate ductile detailing of reinforced concrete members shall be in accordance with good practice [6-1(4)].
In steel structures, members and their connections should be so proportioned that high ductility is obtained, vide SP 6(6), avoiding premature failure due to elastic or inelastic buckling of any type.
The specified earthquake loads are based upon post-elastic energy dissipation in the structure and because of this fact, the provision of this Code for design, detailing and construction shall be satisfied even for structures and members for which load combinations that do not contain the earthquake effect indicate larger demands than combinations including earthquake.
5.3.1.4 Soil-structure interaction
The soil-structure interaction refers to the effects of the supporting foundation medium on the motion of structure. The soil-structure interaction may not be considered in the seismic analysis for structures supported on rock or rock-like material.
5.3.1.5 The design lateral force specified in this Code shall be considered in each of the two orthogonal horizontal directions of the structure. For structures which have lateral force resisting elements in the two orthogonal directions only, the design lateral force shall be considered along one direction at a time, and not in both directions simultaneously. Structures, having lateral force resisting elements (for example, frames, shear walls) in directions other than the two orthogonal directions, shall be analysed considering the load combinations specified in 5.3.3.2.
Where both horizontal and vertical seismic forces are
taken into account, load combinations specified in 5.3.3.3 shall be considered.
5.3.1.6 Equipment and other systems, which are supported at various floor levels of the structure, will be subjected to motions corresponding to vibration at their support points. In important cases, it may be necessary to obtain floor response spectra for design of equipment supports. For detail reference be made to good practice [6-1(5)]
5.3.1.7 Additions to existing structures
Additions shall be made to existing structures only as follows:
a) An addition that is structurally independent from an existing structures shall be designed and constructed in accordance with the seismic requirements for new structures.
b) An addition that is not structurally independent from an existing structure shall be designed and constructed such that the entire structure conforms to the seismic force resistance requirements for new structures unless the following three conditions are complied with:
The addition shall comply with the requirements for new structures;
The addition shall not increase the seismic forces in any structural elements of the existing structure by more than 5 per cent unless the capacity of the element subject to the increased force is still in compliance with this standard; and
The addition shall not decrease the seismic resistance of any structural element of the existing structure unless reduced resistance is equal to or greater than that required for new structures.
5.3.1.8 Change in occupancy
When a change of occupancy results in a structure being reclassified to a higher importance factor (I), the structure shall conform to the seismic requirements for a new structure with the higher importance factor.
5.3.2 Assumptions
The following assumptions shall be made in the earthquake-resistant design of structures:
a) Earthquake causes impulsive ground motions, which are complex and irregular in character, changing in period and amplitude each lasting for a small duration. Therefore, resonance of the type as visualized under steady-state sinusoidal excitations, will not occur as it would need time to build up such amplitudes. NOTE — However, there are exceptions where
resonance-like conditions have been seen to occur between long distance waves and tall structures founded on deep soft soils.
b) Earthquake is not likely to occur simultaneously with wind or maximum flood or maximum sea waves.
c) The value of elastic modulus of materials, wherever required, may be taken as for static analysis unless a more definite value is available for use in such condition (see Part 6 ‘Structural Design, Section 5 Concrete and Section 6 Steel’.
5.3.3 Load Combination and Increase in Permissible Stresses
5.3.3.1 Load combinations
When earthquake forces are considered on a structure, these shall be combined as per 5.3.3.1.1 and 5.3.3.1.2 where the terms DL, IL and EL stand for the response quantities due to dead load, imposed and designated earthquake load respectively.
5.3.3.1.1 Load factors for plastic design of steel structures
In the plastic design of steel structures, the following load combinations shall be accounted for:
a) 1.7 (DL + IL)
b) 1.7 (DL ± EL)
c) 1 . 3 ( D L + I L ± E L )
5.3.3.1.2 Partial safety factors for limit state design of reinforced concrete and prestressed concrete structures
In the limit state design of reinforced and prestressed concrete structures, the following load combinations shall be accounted for:
a) 1.5 (DL + IL)
b) 1.2 (DL+ IL ± EL)
c) 1 . 5 ( D L ± E L )
d) 0.9 D L ± 1 . 5 E L
5.3.3.2 Design horizontal earthquake load
5.3.3.2.1 When the lateral load resisting elements are oriented along orthogonal horizontal direction, the structure shall be designed for the effects due to full design earthquake load in one horizontal direction at time.
5.3.3.2.2 When the lateral load resisting elements are not oriented along the orthogonal horizontal directions, the structure shall be designed for the effects due to full design earthquake load in one horizontal direction plus 30 percent of the design earthquake load in the other direction.
NOTE — For instance, the building should be designed for (± E L x ± 0 . 3 E L y as well as ( ± 0 . 3 E L x ± E L y ) , where x and y are
two orthogonal horizontal direction, EL in 5.3.3.1.1 and 5.3.3.1.2 shall be replaced by ( EL ± 0 . 3 EL ) or ( E L ± 0 . 3 E L )
5.3.4 Design Spectrum
5.3.4.1 For the purpose of determining seismic forces, the country is classified into four seismic zones as shown in Fig. 11.
5.3.4.2 The design horizontal seismic coefficient A h for a structure shall be determined by the following expression:
Ah=2RgZIS
6Snow Load
6.1 This clause deals with snow loads on roofs of buildings. Roofs should be designed for the actual load due to snow or for the imposed loads specified in 3 whichever is more severe.
NOTE — Mountainous regions in northern parts of India are subjected to snow fall.
In India, part of Jammu and Kashmir (Baramulah District, Srinagar District, Anantnag District and Ladakh District); Punjab and Himachal Pradesh (Chamba, Kulu Kinnaur District, Mahasu District, Mandi District, Sirmur District and Simla District); and Uttaranchal (Dehra Dun District, Tehri Garhwal District, Almora District and Nainital District) experience snow fall of varying depths two or three times in a year.
6.2 Notations
(Dimensionless) — Nominal values of the shape coefficients, taking tin account snow draft, sliding snow, etc, with subscripts, if necessary.
l i (metres) — Horizontal dimension with numerical subscripts, if necessary.
h i (metres) — Vertical dimensions with numerical subscripts, if necessary.
β i (degrees) — Roof slope.
s _ 0 (pascals) — Snow load on ground.
s i (pascals) — Snow load on roofs.
6.3 Snow Load in Roof(s)
6.3.1 The minimum design snow load on a roof area or any other area above ground which is subjected to snow accumulation is obtained by multiplying the snow load on ground, s _ 0 by the shape coefficient μ, as applicable to the particular roof area considered:
s = µ s o
where
s = Design snow load in Pa on plan area of roof,
μ = Shape coefficient (see 5.4), and
s = Ground snow load in Pa (1 Pa=1 N/m2)
NOTE — Ground snow load at any place depends on the critical combination of the maximum depth of undisturbed aggregate cumulative snow fall and its average density. In due course the characteristic snow load on ground for different regions will be included based on studies. Till such time the users of this code are advised to contact either Snow and Avalanches Study Establishment (Defence Research and Development Organization), Manali (HP) or Indian Meteorological Department (IMD), Pune in the absence of any specific information for any location.
6.4 Shape Coefficients
6.4.1 General Principles
In perfectly calm weather, falling snow would cover roofs and the ground with a uniform blanket of snow, and the design snow load could be considered as a uniformly distributed load. Truly uniform loading conditions, however, are rare and have usually only been observed in areas that are sheltered on all sides by high trees, buildings, etc. In such a case, the shape coefficient would be equal to unity.
In most regions, snow-falls are accompanied or followed by winds. The winds will re-distribute the snow, and on some roofs especially multilevel roofs, the accumulated drift load may reach a multiple of the ground load. Roofs which are sheltered by other buildings, vegetation, etc, may collect more snow load than the ground level. The phenomenon is of the same nature as that illustrated for multi-level roofs in 6.4.2.4.
So far sufficient data are not available to determine the shape coefficient on a statistical basis. Therefore, a nominal value is given. A representative sample of roofs is shown in 6.4.2. However, in special cases such as strip loading, cleaning of the roof periodically by deliberate heating of the roof, etc, have to be treated separately.
The distribution of snow in the direction parallel to the caves is assumed to be uniform.
6.4.2.2
6.4.2 Shape Coefficients for Selected Types of Roofs
6.4.2.1
μ↓
0°<β≤30°
μ1=0.8
μ2=μ1=0.8
15°<β≤30°
μ2=0.8+0.4(β-15/15)μ1=0.8
30°<β≤60°
μ1=0.8(60-β/30)
μ2=1.2(60-β/30)μ1=0.8(60-β/30)
β>60°
μ1=0
μ2=μ1=0
For asymmetrical simple pitched roofs, each side of the roof shall be treated as one half of corresponding symmetrical roofs.
6.4.2.3 Simple curved roofs
THE FOLLOWING CASES 1 AND 2 MUST BE EXAMINED
6.4.2.4 Multi-level roofs1)
μ1=0.8μ2=μ
where
μs = due to sliding
µw = due to wind
l _ 3 = 2 h 2 ) but is restricted as follows:
5 m ≤ l ₃ ≤ 1 5 m
μw=2hl1+l
with the restriction 0 . 8 ≤ µ _ w ≤ 4 . 0 where
h is in metres
s _ 0 is in kilopascals (kilonewtons per square metre) k = 2 kN/m2
β ≥ 1 5 ° : µ s is determined from an additional load amounting to 50 percent of the maximum total load on the adjacent slope of the upper roof 1), and is distributed linearly as shown in the figure.
β ≤ 15°:µs = 0
A
1
2 < 3,
more extensive formula for is described in Annex A. μw
If l l the coefficient μ is determined by interpolation between μ and μ
The load on the upper roof is calculated according to 6.4.2.1 or 6.4.2.2.
6.4.2.5 Complex multi-level roofs
l ₂ = 2 h ₁: l ₃ = 2 h ₂: µ₁ = 0. 8
Restriction:
5 m < l ₂ ≤ 1 5 m;
5 m < l ₃ ≤ 1 5 m;
µ 2 and µ _ 3 = ( µ _ s + µ _ w ) , are calculated according to 6.4.2.1, 6.4.2.2 and 6.4.2.4.
6.4.2.6 Roofs with local projections and obstructions
6.4.3 Shape Coefficients in Areas Exposed to Wind
The shape coefficients given in 6.4.2 and Annex K may be reduced by 15 percent, provided the designer has demonstrated that the following conditions are fulfilled:
a) The building is located in an exposed location, such as open level terrain with only scattered buildings, trees or other obstructions so that the roof is exposed to the winds on all sides and is not likely to become shielded in the future by obstructions higher than the roof
within a distance from the building equal to ten times the height of the obstruction above the roof level; and
b) The roof does not have any significant projections, such as, parapet walls which may prevent snow from being blow off the roof.
NOTE — In some areas, winter climate may not be of such a nature as to produce a significant reduction of roof loads from the snow load on the ground these areas area:
a) Winter calm valleys in the mountains where sometimes layer after layer of snow accumulates
on roofs without any appreciable removal of snow by wind; and
b) Areas (that is, high temperature) where the maximum snow load may be the result of single snowstorm, occasionally without appreciable wind removal.
In such area, the determination of the shape coefficients shall be based on local experience with due regard to the likelihood of wind drifting and sliding.
7Special Loads
7.1 This clause gives guidance on loads and load effects due to temperature changes, soil and hydrostatic pressures, internally generating stresses (due to creep, shrinkage, differential settlement, etc), accidental loads, etc, to be considered in the design of buildings as appropriate. This clause also includes guidance on load combinations. The nature of loads to be considered for a particular situation is to be based on engineering judgement (see also 3.6)
7.2 Temperature Effects
7.2.1 Expansion and contraction due to changes in temperature of the materials of a structure shall be considered in design. Provision shall be made either to relieve the stress by the provision of expansion/ contraction joints in accordance with good practice [6-1(10)] or design the structure to carry additional stresses due to temperature effects as appropriate to the problem.
7.2.1.1 The temperature range varies for different regions and under different diurinal and seasonal conditions. The absolute maximum and minimum temperature which may be expected in different localities in Annex B of Part 6 ‘Structural Design, Section 6 Steel’ respectively. These figures may be used for guidance in assessing the maximum variations of temperature.
7.2.1.2 The temperatures indicated are the air temperatures in the shade. The range of variation in temperature of the building materials may be appreciably greater or less than the variation of air temperature and is influenced by the condition of exposure and the rate at which the materials composing the structure absorb or radiate heat. This difference in temperature variations of the material and air should be given due consideration.
7.2.1.3 The structural analysis must take account of changes of the mean (through the section) temperature in relation to the initial (st) and the temperature gradient through the section.
a) It should be borne in mind that the changes of mean temperature in relation to the initial are liable to differ as between one structural
element and another in buildings or structures, as for example, between the external walls and the internal elements of a building. The distribution of temperature through section of single-leaf structural elements may be assumed linear for the purpose of analysis.
b) The effect of mean temperature changes t 1 and t 2 ° and the temperature gradients 1 and 2 in the hot and cold seasons for single-leaf structural elements shall be evaluated on the basis of analytical principles.
1 For portions of the structure below ground level, the variation of temperature is generally insignificant. However, during the period of construction, when the portions of the structure are exposed to weather elements, adequate provision should be made to encounter adverse effects, if any.
2 If it can be shown by engineering principles, or if it is known from experience, that neglect of some or all the effects of temperature do not affect the structural safety and serviceability, they need not be considered in design.
5.4Buildings
5.4.1 Regular and Irregular Configuration
To perform well in an earthquake, a building should possess four main attributes, namely, simple and regular configuration, and adequate lateral strength, stiffness and ductility. Buildings having simple regular in plan as well as in elevation, suffer much less damage
Based upon Survey of India Outline Map printed in 1993.
The territorial waters of India extend into the sea to a distance of twelve nautical miles measured from the appropriate base line. The boundary of Meghalaya shown on this map is as interpreted from the North-Eastern Areas (Reorganisation) Act, 1971, but has yet to be verified. Responsibility for correctness of internal details shown on the map rests with the publisher. The state boundaries between Uttaranchal & Uttar Pradesh, Bihar & Jharkhand and Chhatisgarh & Madhya Pradesh have not been verified by Governments concerned.
NOTE — Towns falling at the boundary of zones demarcation line between two zones shall be considered in higher zone.
FIG. 11 SEISMIC ZONES
FIG. 12 RESPONSE SPECTRA FOR ROCK AND SOIL SIGHT FOR 5 PERCENT DAMPING
than buildings with irregular configurations. A building shall be considered as irregular for the purposes of this standard, if at least one of the conditions given in Tables 33 and 34 is applicable.
Table 33Definitions of Irregular Buildings Plan Irregularities (Fig. 13) (Clause 5.4.1)
Sl No.
Irregularity Type and Description
i)
Torsion Irregularity To be considered when floor diaphragms are rigid in their own plan in relation to the vertical structural elements that resist the lateral forces. Torsional irregularity to be considered to exist when the maximum storey drift, computed with design eccentricity, at one end of the structures transverse to an axis is more than 1.2 times the average of the storey drifts at the two ends of the structure.
ii)
Re-entrant Corners Plan configurations of a structure and its lateral force resisting system contain re-entrant corners, where both projections of the structure beyond the re-entrant corner are greater than 15 percent of its plan dimension in the given direction.
iii)
Diaphragm Discontinuity Diaphragms with abrupt discontinuities or variations in stiffness, including those having cut-out or open areas greater than 50 percent of the gross enclosed diaphragm area, or changes in effective diaphragm stiffness of more than 50 percent from one storey to the next.
iv)
Out- of- Plane Offsets Discontinuities in a lateral force resistance path, such as out-of-plane offsets of vertical elements.
v)
Non-parallel Systems The vertical elements resisting the lateral force are not parallel to or symmetric about the major orthogonal axes or the lateral force resisting elements.
a) Stiffness Irregularity - Soft Storey A soft storey is one in which the lateral stiffness is less than 70 percent of that in the storey above or less than 80 percent of the average lateral stiffness of the three storeys above. b) Stiffness Irregularity - Extreme Soft Storey An extreme soft storey is one in which the lateral stiffness is less than 60 percent of that in the storey above or less than 70 percent of the average stiffness of the three storeys above. For example, buildings on STILTS will fall under this category.
ii)
Mass Irregularity Mass irregularity shall be considered to exist where the seismic weight of any storey is more than 200 percent of that of its adjacent storeys. The irregularity need not be considered in case of roofs.
iii)
Vertical Geometric Irregularity Vertical geometric irregularity shall be considered to exist where the horizontal dimension of the lateral force resisting system in any storey is more than 150 percent of that in its adjacent storey.
iv)
In-Plane Discontinuity in Vertical Elements Resisting Lateral Force An in-plane offset of the lateral force resisting elements greater than the length of those elements.
v)
Discontinuity in Capacity - Weak Strorey A weak storey is one in which the storey lateral strength is less than 80 percent of that in the storey above. The storey lateral strength is the total strength of all seismic force resisting elements sharing the storey shear in the considered direction.
FIG. 13 PLAN IRREGULARITIES — Continued
FOLI L ING STFF ES
MASS IRREGULA
STIFFNESS IRREGULA
VERTICAL IRREGULARITIES — Co
MTY WH'-1 <
MASSRSTIO
14 C VERTICAL GEOMETRIC IRREGULARITY, WHEN L 2 > 1 . 5 L 1
14 D IN - PLANE DISCONTINUITY VERTICAL ELEMENTS RESISTING LATERAL FORCE, WHEN b > a
FIG. 14 VERTICAL IRREGULARITIES
5.4.2 Importance Factor I and Response Reduction Factor R
The minimum value of importance factor, I, for different building systems shall be as given in Table 35. The response reduction factor, R, for different building systems shall be as given in Table 36.
5.4.3 Design Imposed Loads for Earthquake Force Calculation
5.4.3.1 For various loading classes as specified in IS 875 (Part 2), the earthquake force shall be calculated for the full dead load plus the percentage of imposed load as given in Table 37.
5.4.3.2 For calculating the design seismic forces of the structure, the imposed load on roof need not be considered.
5.4.3.3 The percentage of imposed loads given in 5.3.3.1 and 5.3.3.2 shall also be used for ‘Whole frame loaded’ condition in the load combinations specified in 5.3.3.1.1 and 5.3.3.1.2 where the gravity loads are combined with the earthquake loads [that is in load combinations (a) in 5.3.3.1.1, and (b) in 5.3.3.1.2]. No further reduction in the imposed load will be used as envisaged in 3 for number of storeys above the one under consideration or for large spans of beams or floors.
5.4.3.4 The proportions of imposed load indicated above for calculating the lateral design forces for earthquakes are applicable to average conditions. Where the probable loads at the time of earthquake are more accurately assessed, the designer may alter the proportions indicated or even replace the entire
Table 35Importance Factors, I (Clauses 5.3.4.2 and 5.4.2)
Sl No.
Structure
Importance Factor
i)
Important service and community buildings, such as hospitals; schools; monumental structures; emergency buildings like telephone exchange, television stations, radio stations, railway stations, fire station buildings; large community halls like cinemas, assembly halls and subway stations, power stations.
1.5
ii)
All other buildings.
1.0
NOTES
1
The design engineer may choose values of importance factor I greater than those mentioned above.
2
Buildings not covered in Sl No. (i) and (ii) above may be designed for higher value of I, depending on economy, strategy considerations like multi-storey buildings having several residential units.
3
This does not apply to temporary structures like excavations, scaffolding etc of short duration.
Table 36Response Reduction Factor1) R, for Building Systems (Clauses 5.3.4.2 and 5.4.2)
Sl No.
Lateral Load Resisting System
R
Building Frame Systems
i)
Ordinary RC Moment-Resisting Frame (OMRF) ²⁾
3.0
ii)
Special RC Moment-Resisting Frame (SMRF) ³⁾
5.0
iii)
Steel Frame with a) Concentric Braces
4.0
b) Eccentric Braces
5.0
iv)
Steel Moment Resisting Frame designed as per SP: 6(6)
5.0
Building with Shear Walls ⁴⁾
v)
Load Bearing Masonry Wall Buildings ⁵⁾
a) Unreinforced
1.5
b) Reinforced with horizontal RC Bands
2.5
c) Reinforced with horizontal RC bands and vertical bars at corners of rooms and jambs of openings
3.0
vi)
Ordinary Reinforced Concrete Shear Walls ⁶⁾
3.0
vii)
Ductile Shear Walls ⁷⁾
4.0
Buildings with Dual Systems ⁸⁾
viii)
Ordinary Shear Wall with OMRF
3.0
ix)
Ordinary Shear Wall with SMRF
4.0
x)
Ductile Shear Wall with OMRF
4.5
xi)
Ductile Shear Wall with SMRF
5.0
The above values of response reduction factors are to be used for buildings with lateral load resisting elements, and not just for the lateral load resisting elements built in isolation.
OMRF are those designed and detailed as per IS 456 or IS 800 but not meeting ductile detailing requirement as per IS 13920.
SMRF defined in 4.15.2.
Buildings with shear walls also include buildings having shear walls and frames, but where
a) frames are not designed to carry lateral loads, or
b) frames are designed to carry lateral loads but do not fulfil the requirements of ‘dual systems’.
Reinforcement should be as per IS 4326.
Prohibited in Zones IV and V.
Ductile shear walls are those designed and detailed as per IS 13920 8) Buildings with dual systems consist of shear walls (or braced frames) and moment resisting frames such that
a) the two systems are designed to resist the total design force in proportion to their lateral stiffness considering the interaction of the dual system at all floor levels; and
Table 37Percentage of Imposed Load to be Considered in Seismic Weight Calculation (Clause 5.4.3.1)
Imposed Uniformity Distributed
Percentage of Imposed
Floor Loads (kN/sq.m)
Load
Up to and including 3.0
25
Above 3.0
50
imposed load proportions by the actual assessed load. In such cases, where the imposed load is not assessed as per 5.4.3.1 and 5.4.3.2 only that part of imposed load, which possesses mass, shall be considered. Lateral design force for earthquakes shall not be calculated on contribution of impact effects from imposed loads.
5.4.3.5 Other loads apart from those given above (for example, snow and permanent equipment) shall be considered as appropriate.
5.4.4 Seismic Weight
5.4.4.1 Seismic weight of floors
The seismic weight of each floor is its full dead load plus appropriate amount of imposed load, as specified in 5.4.3.1 and 5.4.3.2. While computing the seismic weight of each floor, the weight of columns and walls in any storey shall be equally distributed to the floors above and below the storey.
5.4.4.2 Seismic weight of building
The seismic weight of the whole building is the sum of the seismic weights of all the floors.
5.4.4.3 Any weight supported in between storeys shall be distributed to the floors above and below in inverse proportion to its distance from the floors.
5.4.5 Design Lateral Force
5.4.5.1 Buildings and portions thereof shall be designed and constructed, to resist the effects of design lateral force specified in 5.4.5.3 as a minimum.
5.4.5.2 The design lateral force shall first be computed for the building as a whole. This design lateral force shall then be distributed to the various floor levels. The overall design seismic force thus obtained at each floor level, shall then be distributed to individual lateral load resisting elements depending on the floor diaphragm action.
5.4.5.3 Design seismic base shear — The total design lateral force or seismic base shear ( V B ) along any principal direction shall be determined by the following expression:
V B = A h W
where
A h = Design horizontal acceleration spectrum value as per 5.3.4.2, using the fundamental natural period as per 5.4.6 in the considered direction of vibration; and
W = Seismic weight of the building as per 5.4.4.2.
5.4.6 Fundamental Natural Period
5.4.6.1 The approximate fundamental natural period
of vibration ( T a ) , , in seconds, of a moment-resisting frame building without brick infill panels may be estimated by the empirical expression:
Ta=0.075h0.75
5.4.7 Distribution of Design Force
5.4.7.1 Vertical distribution of base shear to different floor levels
The design base shear ( V B ) computed in 5.4.5.3 shall be distributed along the height of the building as per the following expression:
Qi=VB
5.4.8 Dynamic Analysis
5.4.8.1 Dynamic analysis shall be performed to obtain the design seismic force, and its distribution to different levels along the height of the building and to the various lateral load resisting elements, for the following buildings:
a) Regular buildings — Those greater than 40 m in height in Zones IV and V, and those greater than 90 m in height in Zones II and III. Modelling as per 5.4.8.4.5 can be used.
b) Irregular buildings (as defined in 5.4.1) — All framed buildings higher than 12 m in Zones IV and V, and those greater than 40 m in height in Zones II and III.
The analytical model for dynamic analysis of buildings with unusual configuration should be such that it adequately models the types of irregularities present in the building configuration. Buildings with plan irregularities, as defined in Table 33 (as per 5.4.1), cannot be modelled for dynamic analysis by the method given in 5.4.8.4.5
NOTE — For irregular buildings, lesser than 40 m in height in Zones II and III, dynamic analysis, even though not mandatory, is recommended.
5.4.8.2 Dynamic analysis may be performed either by the Time History Method or by the Response Spectrum Method. However, in either method, the design base shear ( V B ) shall be compared with a base shear ( V B ) calculated using a fundamental period T a , where T a is as per 5.4.6. Where V B is less than V B , , all the response quantities (for example, member forces, displacements, storey forces, storey shears and base reactions) shall be multiplied by V B / V B ~ ) .
5.4.8.2.1 The value of damping for buildings may be taken as 2 and 5 percent of the critical, for the purposes
of dynamic analysis of steel and reinforced concrete buildings, respectively.
5.4.8.3 Time history method
Time history method of analysis, when used, shall be based on an appropriate ground motion and shall be performed using accepted principles of dynamics.
5.4.8.4 Response spectrum method
Response spectrum method of analysis shall be performed using the design spectrum specified by 5.3.4.2, or by a site-specific design spectrum mentioned in 5.3.4.6.
5.4.8.4.1 Free vibration analysis
Undamped free vibration analysis of the entire building shall be performed as per established methods of mechanics using the appropriate masses and elastic stiffness of the structural system, to obtain natural periods (T) and mode shapes {Ø} of those of its modes of vibration that need to be considered as per 5.4.8.4.2.
5.4.8.4.2 Modes to be considered
The number of modes to be used in the analysis should be such that the sum total of modal masses of all modes considered is at least 90 percent of the total seismic mass and missing mass correction beyond 33 percent. If modes with natural frequency beyond 33 Hz are to be considered, modal combination shall be carried out only for modes up to 33 Hz. The effect of higher modes shall be included by considering missing mass correction following well established procedures.
5.4.9 Torsion
5.4.9.1 Provision shall be made in all buildings for increase in shear forces on the lateral force resisting elements resulting from the horizontal torsional moment arising due to eccentricity between the centre of mass and centre of rigidity. The design forces calculated as in 5.4.8.4.5 are to be applied at the centre of mass appropriately displaced so as to cause design eccentricity (5.4.9.2) between the displaced centre of mass and centre of rigidity. However, negative torsional shear shall be neglected.
5.4.9.2 The design eccentricity, e d i to be used at floor i shall be taken as
edi=
5.4.10 Buildings with Soft Storey
5.4.10.1 In case buildings with a flexible storey, such as the ground storey consisting of open spaces for parking that is stilt buildings, special arrangement needs to be made to increase the lateral strength and stiffness of the soft/open storey.
5.4.10.2 Dynamic analysis of building is carried out including the strength and stiffness effects of infills and inelastic deformations in the members, particularly, those in the soft storey, and the members designed accordingly.
5.4.10.3 Alternatively, the following design criteria are to be adopted after carrying out the earthquake analysis, neglecting the effect of infill walls in other storeys:
a) the columns and beams of the soft storey are to be designed for 2.5 times the storey shears and moments calculated under seismic loads specified in the other relevant clauses; or,
b) besides the columns designed and detailed for the calculated shears and moments, shear walls placed symmetrically in both directions of the building as far away from the centre of the building as feasible; to be designed exclusively for 1.5 times the lateral shear force calculated as before.
5.4.11 Deformations
5.4.11.1 Storey drift limitation
The storey drift in any storey due to the minimum specified design lateral force, with partial load factor of 1.0, shall not exceed 0.004 times the storey height.
For the purposes of displacement requirements only (that is, in 5.4.11.1, 5.4.11.2 and 5.4.11.3 only), it is permissible to use seismic force obtained from the computed fundamental period (T) of the building without the lower bound limit on design seismic force specified in 5.4.8.2.
There shall be no drift limit for single storey building which has been designed to accommodate storey drift.
5.4.11.2 Deformation compatibility of non-seismic members
For building located in seismic Zones IV and V , it shall be ensured that the structural components, that are not a part of the seismic force resisting system in the direction under consideration, do not lose their vertical load-carrying capacity under the induced moments resulting from storey deformations equal to R times the storey displacements calculated as per 5.4.11.1, where R is specified in Table 36.
NOTE — For instance, consider a flat-slab building in which lateral load resistance is provided by shear walls. Since the lateral load resistance of the slab-column system is small, these are often designed only for the gravity loads, while all the seismic force is resisted by the shear walls. Even though the slabs and columns are not required to share the lateral forces, these deform with rest of the structure under seismic force. The concern is that under such deformations, the slab-column system should not lose its vertical load capacity.
5.4.11.3 Separation between adjacent units
Two adjacent buildings, or two adjacent units of the same building with separation joint in between shall be separated by a distance equal to the amount R times the sum of the calculated storey displacements as per 5.4.11.1 of each of them, to avoid damaging contact when the two units deflect towards each other. When floor levels of two similar adjacent units or buildings are at the same elevation levels, factor R in this requirement may be replaced by R/2.
5.4.12 Miscellaneous
5.4.12.1 Foundations
The use of foundations vulnerable to significant differential settlement due to ground shaking shall be avoided for structures in seismic Zones III, IV and V. In seismic Zones IV and V, individual spread footings or pile caps shall be interconnected with ties, (see 5.2.3.4.1 of IS 4326) except when individual spread footings are directly supported on rock. All ties shall be capable of carrying, in tension and in compression, an axial force equal to A h / 4 times the larger of the column or pile cap load, in addition to the otherwise computed forces. Here, A h is as per 5.3.4.2.
5.4.12.2 Cantilever projections
5.4.12.2.1 Vertical projections
Tower, tanks, parapets, smoke stacks (chimneys) and other vertical cantilever projections attached to buildings and projecting above the roof, shall be designed and checked for stability for five times the design horizontal seismic coefficient A h specified in 5.3.4.2. In the analysis of the building, the weight
of these projecting elements will be lumped with the roof weight.
5.4.12.2.2 Horizontal projection
All horizontal projections like cornices and balconies shall be designed and checked for stability for five times the design vertical coefficient specified in 5.3.4.5.
5.4.12.2.3 The increased design forces specified in 5.4.11.2.1 and 5.4.12.2.2 are only for designing the projecting parts and their connections with the main structures. For the design of the main structure, such increase need not be considered.
5.4.12.3 Compound walls
Compound walls shall be designed for the design horizontal coefficient A h with Importance Factor I = 1.0 specified in 6.4.2
5.4.12.4 Connections between parts
All parts of the building, except between the separation sections, shall be tied together to act as integrated single unit. All connections between different parts, such as, beams to columns and columns to their footings, should be made capable of transmitting a force, in all possible directions, of magnitude ( Q i / W i ) times but not less than 0.05 times the weight of the smaller part or the total of dead and imposed load reaction. Frictional resistance shall not be relied upon for fulfilling these requirements.
7.3Hydrostatic and Soil Pressure
7.3.1 In the design of structures of parts or structures below ground level, such as, retaining walls and other walls in basement floors, the pressure exerted by the soil or water or both shall be duly accounted for on the basis of established theories. Due allowance shall be made for possible surcharge from stationary or moving loads. When a portion or whole of the soil is blow the free water surface, the lateral earth pressure shall be evaluated for weight of soil diminished by buoyancy and the full hydrostatic pressure.
7.3.1.1 All foundation slabs and other footings subjected to water pressure shall be designed to resist a uniformly distributed uplift equal to the full hydrostatic pressure. Checking of overturning of foundation under submerged condition shall be done considering buoyant weight of foundation.
7.3.2 While determining the lateral soil pressure on column like structural members, such as, pillars which rest in sloping soils, the width of the member shall be taken as follows (see Fig. 15).
Actual Width of Member
Ratio of Effective Width to Actual Width
Less than 0.5 m
3.0
Beyond 0.5 m and up to 1 m
3.0 to 2.0
Beyond 1 m
2.0
The relieving pressure of soil in front of the structural member concerned may generally not be taken into account.
FIG. 15 SKETCH SHOWING EFFECTIVE WIDTH OF PILAR FOR CALCULATING SOIL PRESSURE
7.3.3 Safe-guarding of structures and structural members against overturning and horizontal sliding shall be verified. Imposed loads having favourable effect shall be disregarded for the purpose. Due consideration shall be given to the possibility of soil being permanently or temporarily removed.
7.4Fatigue
7.4.1 General
Fatigue cracks are usually initiated at points of high stress concentration. These stress concentrations may be caused by or associated with holes (such as, bolt or rivet holes in steel structures), welds including stray or fusions in steel structures, defects in materials, and local and general changes in geometry of members. The cracks usually propogate, if loading is continuous.
Where there is such loading cycles, sudden changes of shape of a member or part of a member, especially in regions of tensile stress and/or local secondary bending, shall be avoided. Suitable steps shall be taken to avoid critical vibrations due to wind and other causes.
7.4.2 Where necessary, permissible stresses shall be reduced to allow for the effects of fatigue. Allowance for fatigue shall be made for combinations of stresses due to dead load and imposed load. Stresses due to wind and earthquakes may be ignored when fatigue is
being considered, unless otherwise specified in relevant codes of practice.
Each element of the structure shall be designed for the number of stress cycles of each magnitude to which it is estimated that the element is liable to be subjected during the expected life of the structure. The number of cycles of each magnitude shall be estimated in the light of available date regarding the probable frequency of occurrence of each type of loading.
NOTE — Apart from the general observations made herein, the section is unable to provide any precise guidance in estimating the probabilistic behaviour and response of structures of various types arising out of repetitive loading approaching fatigue conditions in structural members, joints, materials, etc.
7.5Structural Safety During Construction
7.5.1 All loads required to be carried by the structures or any part of it due to storage or positioning of construction materials and erection equipment including all loads due to operation of such equipment, shall be considered as erection loads. Proper provision shall be made, including temporary bracings, to take care of all stresses due to erection loads. The conjunction with the temporary bracings shall be capable of sustaining these erection loads, without exceeding the permissible stresses specified in respective codes of practice. Dead load, wind load and such parts of imposed load, as would be imposed on
the structure during the period of erection, shall be taken as acting together with erection loads.
8Load Combinations
8.1 General
A judicious combination of the loads keeping in view the probability of:
a) their acting together; and
b) their disposition in relation to other loads and severity of stresses or deformations caused by the combinations of the various loads, is necessary to ensure the required safety and economy in the design of a structure.
8.2 Land Combinations
Keeping the aspect specified in 8.1, the various loads should, therefore, be combined in accordance with the stipulation in the relevant design codes. In the absence of such recommendations, the following loading combinations, whichever combination produces the most unfavourable effect in the building, foundation or structural member concerned may be adopted (as a general guidance). It should also be recognized in load combinations that the simultaneous occurrence of maximum values of wind, earthquake, imposed and snow loads is not likely.
DL
DL + IL
DL + WL
DL + EL
DL + TL
DL + IL + WL
DL + IL + EL
DL + IL + TL
DL + WL + TL
DL + EL + TL
DL + IL + WL+TL
DL + IL + EL+TL
(DL = dead load, IL = imposed load, WL = wind load, EL = earthquake load and TL = temperature load).
1 When snow load is present on roof’s, replace imposed load by snow load for the purpose of above load combinations.
2 The relevant design codes shall be followed for permissible stresses when the structure is designed by working stress method and for partial safety factors when the structure is designed by limit stale design method for each of the above load combinations.
3 Whenever imposed load (IL) is combined with earthquake load (EL), the appropriate part of imposed load as specified in 5 should be used, both for evaluating earthquake effect and also for combined load effects used in such combination.
4 For the purpose of stability of the structure as a whole against overturning, the restoring moment shall be not less than 1.2 times the maximum overturning moment due to dead load plus 1.4 times the maximum overturning moment due to imposed loads. In cases where dead load provides the restoring moment, only 0.9 times the dead load shall be considered. The restoring moments due to imposed loads shall be ignored.
5 The structure shall have a factor against sliding of not less than 1.4 under the most adverse combination of the applied loads/forces. In this case, only 0.9 times the dead load shall be taken into account.
6 Where the bearing pressure on soil due to wind alone is less than 25 percent of that due to dead load and imposed load, it may be neglected in design where this exceeds 25 percent, foundation may be so proportioned that the pressure due to combined effect of dead load, imposed load and wind load does not exceed the allowable bearing pressure by more than 25 percent. When earthquake effect is included, the permissible increase in allowable bearing pressure in the soil shall be in accordance with 5.
9Multi-hazard Risk in Various Districts of India
9.1 Multi-Hazard Risk Concept
The commonly encountered hazards are:
a) earthquake,
b) cyclone,
c) wind storm,
d) floods,
e) landslides,
f) liquefaction of soils,
g) extreme winds,
h) cloud bursts, and
j) failure of slopes.
A study of the earthquake, wind/cyclone, and flood hazard maps of India indicate that there are several areas in the country which run the risk of being affected by more than one of these hazards.
Further there may be instances where one hazard may cause occurrence or accentuation of another hazard, such as landslides may be triggered/accelerated by earthquakes and wind storms and floods by the cyclones.
It is important to study and examine the possibility of occurrence of multiple hazards, as applicable to an area. However, it is not economically viable to design all the structures for multiple hazards. The special structures, such as, nuclear power plants, and life line structures, such as, hospitals and emergency rescue shelters may be designed for multiple hazards. For such special structures, site specific data have to be collected and the design be carried out based on the accepted levels of risk. The factors that have to be considered in determining this risk are:
a) The severity of the hazard characterized by M.M. (or M.S.K.) intensity in the case of earthquake; the duration and velocity of wind in the storms; and unprotected or protected situation of flood prone areas; and
b) The frequency of occurrence of the severe hazards.
Till such time that risk evaluation procedures are formalized, the special structures may be designed for multiple hazards using the historical data, that can be obtained for a given site and the available Code for loads already covered. The designer may have to consider the loads due to any one of the hazards individually or in combination as appropriate.
9.2 Multi-Hazard Prone Areas
The criteria adopted for identifying multi hazard prone areas may be as follows:
a) Earthquake and Flood Risk Prone — Districts which have seismic Zone of intensity 7 or more and also flood prone unprotected or protected area. Earthquake and flood can occur separately or simultaneously.
Annex A[Clause 3.3.2.1(b)] Illustrative Example Showing Reduction of Uniformly Distributed Imposed Floor Loads in Multi-storeyed Buildings for Design of Columns
A-1 The total imposed loads from different floor levels (including the roof) combing on the central column of a multi-storeyed building (with mixed occupancy) is shown in Fig. 20. Calculate the reduced imposed load for the design of column members at different
floor levels using 3.3.2.1. Floor loads do not exceed 5.0 kN/m2.
A-1.1 Applying reduction coefficients in accordance with 3.3.2.1, total reduced floor loads on the column at different levels is indicated along with Fig. 18.
a) Class rooms and lecture rooms (not used for assembly purposes)
3.0
2.7
b) Dining rooms, cafeterias and restaurants
3.0¹⁾
2.7
c) Offices, lounges and staff rooms
2.5
2.7
d) Dormitories
2.0
2.7
e) Projection rooms
5.0
—
f) Kitchens
3.0
4.5
g) Toilets and bathrooms
2.0
—
h) Store rooms
5.0
4.5
j) Libraries and archives:
1) Stack room/stack area
6.0 kN/m² for a minimum height of 2.2 m + 2.0 kN/m² per metre height beyond 2.2 m
4.5
2) Reading rooms (without separate storage)
4.0
4.5
3) Reading rooms (with separate storage)
3.0
4.5
k) Boiler rooms and plant rooms — to be calculated but not less than
4.0
4.5
m) Corridors, passages, lobbies, staircases including fire escapes — as per the floor serviced (without accounting for storage and projection rooms) but not less than
4.0
4.5
n) Balconies
Same as rooms to which they give access but with a minimum of 4.0
1.5 metre run concentrated at the outer edge
7.5
4.5
n) Corridors, passages, subject to loads greater than from crowds, such as wheeled vehicles, trolleys and the like corridors, staircases and passages in grandstands
5.0
4.5
v)
Business and Office Buildings (see also 3.2.1)
a) Rooms for general use with separate storage
2.5
2.7
b) Rooms without separate storage
4.0
4.5
c) Banking halls
3.0
2.7
d) Business computing machine rooms (with fixed computers or similar equipment)
3.5
4.5
e) Records/files store rooms and storage space
5.0
4.5
f) Vaults and strong rooms — to be calculated but not less than
5.0
4.5
g) Cafeterias and dinning rooms
3.0¹⁾
2.7
h) Kitchens
3.0
2.7
j) Corridors, passages, lobbies, staircases including fire escapes — as per the floor serviced (excluding stores) but not less than
4.0
4.5
k) Bath and toilets rooms
2.0
—
m) Balconies
Same as rooms to which they give access but with a minimum of 4.0
1.5 metre run concentrated at the outer edge
n) Stationary stores
4.0 for each metre of storage height
9.0
p) Boiler rooms and plant rooms — to be calculated but not less than
5.0
6.7
q) Libraries
See S1 No. (ii)
7.0
b) Cold storage — to be calculated but not less than
5.0 kN/m² per metre of storage height with a minimum of 15 kN/m²
9.0
c) Corridors, passages, staircases including fire escapes — as per the floor serviced but not less than
4.0
4.5
d) Corridors, passages subject to loads greater than from crowds, such as wheeled vehicles, trolleys and the like
5.0
4.5
e) Boiler rooms and plant rooms
7.5
4.5
¹⁾ Where unrestricted assembly of persons is anticipated, the value of UDL should be increased to 4.0 kN/m² ²⁾ With fixed seats' implies that the removal of the seating and the use of the space for other purposes is improbable. The maximum likely load in this case is, therefore, closely controlled. ³⁾ The loading in industrial buildings (workshops and factories) varies considerably and so three loadings under the terms 'light', 'medium' and 'heavy' are introduced in order to allow for more economical designs but the terms have no special meaning in themselves other than the imposed load for which the relevant floor is designed. It is, however, important particularly in the case of heavy weight loads, to assess the actual loads to ensure that they are not in excess of 10 kN/m² ; in case where they are in excess, the design shall be based on the actual loadings. ⁴⁾ For various mechanical handling equipment which are used to transport goods, as in warehouses, workshops, store rooms, etc, the actual load coming from the use of such equipment shall be ascertained and design should cater to such loads.
For all ladle cranes and charging cranes where there is possibility of overloading from production considerations, an overloading factor of 10 percent of the maximum wheel loading shall be taken.
(1)
(2)
All general buildings and structures
50
1.0
1.0
1.0
1.0
1.0
1.0
Temporary sheds, structures such as those used during construction operations (for example, formwork and falsework), structures during construction stages and boundary walls
5
0.82
0.76
0.73
0.71
0.70
0.67
Buildings and structures presenting a low degree of hazard to life and property in the event of failure, such as isolated towers in wooded areas, farm buildings, other than residential buildings
25
0.94
0.92
0.91
0.90
0.90
0.89
Important buildings and structures, such as hospitals, communications buildings/towers and power plant structures
100
1.05
1.06
1.07
1.07
1.08
1.08
k1= XN,PNX50,0.63= A-B [ -(1)/(N) (1-PN) ]A+4B
where
N = mean probable design life of structure in years;
PN = risk level in N consecutive years (probability that the design wind speed is exceeded at least once in N successive years), nominal value = 0.63;
XN, PN = extreme wind speed for given values of N and PN ; and
X50,0.63 = extreme wind speed for N = 50 years and PN = 0.63
A and B are coefficients having the following values for different basic wind speed zones:
Zone
A
B
33 m/s
83.2
9.2
39 m/s
84.2
14.0
44 m/s
88.0
18.0
47 m/s
88.0
20.5
50 m/s
88.8
22.8
55 m/s
90.8
27.3
NOTE — The factor k is based on statistical concepts which take account of the degree of reliability required and period of time in years during which there will be exposure to wind, that is, life of the structure. Whatever wind speed is adopted for design purposes, there is always a probability (however small) that it may be exceeded in a storm of exceptional violence; the greater the period of years over which there will be exposure to wind, the greater is the probability. Higher return periods ranging from 100 to 1 000 years (implying lower risk level) in association with greater periods of exposure may have to be selected for exceptionally important structures, such as nuclear power reactors and satellite communication towers. Equation given above may be used in such cases to estimate k 1 factors for different periods of exposure and chosen probability of exceedence (risk level). The probability level of 0.63 is normally considered sufficient for design of buildings and structures against wind effects and the values of k 1 corresponding to this risk level are given in Table 4.
design of a structure may vary depending on the direction of wind under consideration. Wherever sufficient meteorological information is available about the nature of wind direction, the orientation of any building or structure may be suitably planned.
Terrian, in which a specific structure stands, shall be assessed as being one of the following terrain categories:
Category 1 — Exposed open terrain with few or no obstructions and in which the average height of any objects surrounding the structure is less than 1.5 m.
NOTE — This category includes open sea-coasts and flat treeless plains.
Category 2 — Open terrain with well scattered obstructions having heights generally between 1.5 and 10 m.
NOTE — This is the criterion for measurement of regional basic wind speeds and includes airfields, open parklands and undeveloped sparsely built-up outskirts of towns and suburbs. Open land adjacent to sea coast may also be classified as category 2 due to roughness of large sea waves at high winds.
Category 3 — Terrain with numerous closely spaced obstruction having the size of building-structures up to 10 m in height with or without a few isolated tall structures.
1 This category includes well wooded areas and shrubs, towns and industrial areas fully or partially developed.
2 It is likely that the next higher category than this will not exist in most design situations and that selection of a more severe category will be deliberate.
3 Particular attention must be given to the performance of the obstructions in areas affected by fully developed tropical cyclones. Vegetation, which is likely to be blown down or defoliated, cannot be relied upon to maintain Category 3 conditions. Where such situation may exist, either an intermediate category with velocity multipliers midway between the values for Categories 2 and 3 given in Table 5 or Category 2 should be selected having due regard to local conditions.
Category 4 — Terrain with numerous large high closely spaced obstructions.
NOTE — This category includes large city centres, generally with obstructions above 25 m and well developed industrial complexes.
b) Variation of Wind Speed with Height for Different Sizes of Structure in Different Terrains (k Factor) — Table 5 gives
multiplying factors (k ) by which the basic wind speed given in Fig. 1 shall be multiplied to obtain the wind speed at different heights, in each terrain category for different sizes of buildings/structures.
The buildings/structures are classified into the following three different classes depending upon their size:
Class A — Buildings and/or their components, such as cladding, glazing, roofing etc, having maximum dimension (greatest horizontal or vertical dimension) less than 20 m.
Class B — Buildings and/or their components, such as cladding, glazing, roofing etc, having maximum dimension (greatest horizontal or vertical dimension) between 20 m and 50 m.
Class C — Buildings and/or their components, such as cladding, glazing, roofing etc, having maximum dimension (greatest horizontal or vertical dimension) greater than 50 m.
c) Terrain Categories in Relation to the Direction of Wind — The terrain category used in the design of a building may vary depending on the direction of wind under consideration. Where sufficient meteorological information is available, the basic wind speed may be varied for specific wind direction.
Table 5k Factors to Obtain Design Wind Speed Variation with Height in Different Terrains for Different Classes of Building Structures [Clause 4.4.3.2 (b)]
Height (m)
Terrain Category 1 Class
Terrain Category 2 Class
Terrain Category 3 Class
Terrain Category 4 Class
A
B
C
A
B
C
A
B
C
A
B
C
10
1.05
1.03
0.99
1.00
0.98
0.93
0.91
0.88
0.82
0.80
0.76
0.67
15
1.09
1.07
1.03
1.05
1.02
0.97
0.97
0.94
0.87
0.80
0.76
0.67
20
1.12
1.10
1.06
1.07
1.05
1.00
1.01
0.98
0.91
0.80
0.76
0.67
30
1.15
1.13
1.09
1.12
1.10
1.04
1.06
1.03
0.96
0.97
0.93
0.83
50
1.20
1.18
1.14
1.17
1.15
1.10
1.12
1.09
1.02
1.10
1.05
0.95
100
1.26
1.24
1.20
1.24
1.22
1.17
1.20
1.17
1.10
1.20
1.15
1.05
150
1.30
1.28
1.24
1.28
1.25
1.21
1.24
1.21
1.15
1.24
1.20
1.10
200
1.32
1.30
1.26
1.30
1.28
1.24
1.27
1.24
1.18
1.27
1.22
1.13
250
1.34
1.32
1.28
1.32
1.31
1.26
1.29
1.26
1.20
1.28
1.24
1.16
300
1.35
1.34
1.30
1.34
1.32
1.28
1.31
1.28
1.22
1.30
1.26
1.17
350
1.37
1.35
1.31
1.36
1.34
1.29
1.32
1.30
1.24
1.31
1.27
1.19
400
1.38
1.36
1.32
1.37
1.35
1.30
1.34
1.31
1.25
1.32
1.28
1.20
450
1.39
1.37
1.33
1.38
1.36
1.31
1.35
1.32
1.26
1.33
1.29
1.21
500
1.40
1.38
1.34
1.39
1.37
1.32
1.36
1.33
1.28
1.34
1.30
1.22
1 See 4.4.3.2 (b) for definitions of Class A, Class B and Class C structures.
2 Intermediate values may be obtained by linear interpolation, if desired. It is permissible to assume constant wind speed between two heights for simplicity.
d) Changes in Terrain Categories — The velocity profile for a given terrain category does not develop to full height immediately with the commencement of that terrain category, but develops gradually to height (h ), which increases with the fetch or upwind distance (x)
Fetch and Developed Height Relationship — The relation beween the developed height ( h x ) and the fetch (x) for wind-flow over each of the four terrain categories may be taken as given in Table 6.
For buildings of heights greater than the developed height ( h _ X ) in Table 6, the velocity profile may be determined in accordance with the following:
i) The less or least terrain; or
ii) The method described in Annex D.
Table 6 Fetch and Developed Height Relationship [Clause 4.4.3.2 (b)]
NOTE — h is the height of eaves or parapet, l is the greater horizontal dimension of a building and w is the lesser horizontal dimension of a building.
Table 8External Pressure Coefficients ( C p e ) for Pitched Roofs of Rectangular Clad Buildings [Clause 4.5.2.2 (b)]
Building Height Ratio
Roof Angle degrees
Wind Angle θ 0°
Wind Angle θ 90°
Local Coefficients
EF
GH
EG
FH
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(h)/(w) ≤ (1)/(2)
0
-0.8
-0.4
-0.8
-0.4
-2.0
-2.0
-2.0
—
5
-0.9
-0.4
-0.8
-0.4
-1.4
-1.2
-1.2
-1.0
10
-1.2
-0.4
-0.8
-0.6
-1.4
-1.4
-1.2
20
-0.4
-0.4
-0.7
-0.6
-1.0
-1.2
30
0
-0.4
-0.7
-0.6
-0.8
-1.1
45
+0.3
-0.5
-0.7
-0.6
-1.1
60
+0.7
-0.6
-0.7
-0.6
-1.1
(1)/(2) < (h)/(w) ≤ (3)/(2)
0
-0.8
-0.6
-1.0
-0.6
-2.0
-2.0
-2.0
—
5
-0.9
-0.6
-0.9
-0.6
-2.0
-2.0
-1.5
-1.0
10
-1.1
-0.6
-0.8
-0.6
-2.0
-2.0
-1.5
-1.2
20
-0.7
-0.5
-0.8
-0.6
-1.5
-1.5
-1.5
-1.0
30
-0.2
-0.5
-0.8
-0.8
-1.0
-1.0
45
+0.2
-0.5
-0.8
-0.8
60
+0.6
-0.5
-0.8
-0.8
(3)/(2) < (h)/(w) < 6
0
-0.7
-0.6
-0.9
-0.7
-2.0
-2.0
-2.0
—
5
-0.7
-0.6
-0.8
-0.8
-2.0
-2.0
-1.5
-1.0
10
-0.7
-0.6
-0.8
-0.8
-2.0
-2.0
-1.5
-1.2
20
-0.8
-0.6
-0.8
-0.8
-1.5
-1.5
-1.5
-1.2
30
-1.0
-0.5
-0.8
-0.7
-1.5
40
-0.2
-0.5
-0.8
-0.7
-1.0
50
+0.2
-0.5
-0.8
-0.7
60
+0.5
-0.5
-0.8
-0.7
NOTES
1 h is the height to caves or parapet, w is the lesser horizontal dimension of a building.
2 Where no local coefficients are given the overall coefficients apply.
OVERALL COEFFICIENTS
Table 9 External Pressure Coefficients ( C p e ) for Monoslope Roofs for Rectangular [Clause 4.5.2.2 (c)]
y = h or 0.15 w, whichever is the lesser
NOTE — Area H and area L refer to the whole quadrant.
Roof Angle α Degree
Wind Angle θ
0°
45°
90°
135°
180°
H
L
H
L
H & L
H & L
H
L
H
L
Applies to length w/2 from wind ward end
Applies to remainder
5
-1.0
-0.5
-1.0
-0.9
-1.0
-0.5
-0.9
-1.0
-0.5
-1.0
10
-1.0
-0.5
-1.0
-0.8
-1.0
-0.5
-0.8
-1.0
-0.4
-1.0
15
-0.9
-0.5
-1.0
-0.7
-1.0
-0.5
-0.6
-1.0
-0.3
-1.0
20
-0.8
-0.5
-1.0
-0.6
-0.9
-0.5
-0.5
-1.0
-0.2
-1.0
25
-0.7
-0.5
-1.0
-0.6
-0.8
-0.5
-0.3
-0.9
-0.1
-0.9
30
-0.5
-0.5
-1.0
-0.6
-0.8
-0.5
-0.1
-0.6
0
-0.6
Roof Angle
LOCAL COEF
FICIENTS C<sub>pe</sub>
Degree
H<sub>1</sub>
H<sub>2</sub>
L<sub>1</sub>
L<sub>2</sub>
H
L
5
-2.0
-1.5
-2.0
-1.5
-2.0
-2.0
10
-2.0
-1.5
-2.0
-1.5
-2.0
-2.0
15
-1.8
-0.9
-1.8
-1.4
-2.0
-2.0
20
-1.8
-0.8
-1.8
-1.4
-2.0
-2.0
25
-1.8
-0.7
-0.9
-0.9
-2.0
-2.0
30
-1.8
-0.5
-0.5
-0.5
-2.0
-2.0
NOTE — h is the height to eaves at lower side, l is greater horizontal dimension of a building and w is the lesser horizontal dimension of a building.
Maximum (Largest +ve) and Minimum (Largest -ve) Pressure Coefficients
Overall coefficients
Local coefficients
Degree
-20
All values of ∅
+0.7
+0.8
+1.6
+0.6
+1.7
-15
+0.5
+0.6
+1.5
+0.7
+1.4
-10
+0.4
+0.6
+1.4
+0.8
+1.1
-5
+0.3
+0.5
+1.5
+0.8
+0.8
+5
+0.3
+0.6
+1.8
+1.3
+0.4
+10
+0.4
+0.7
+1.8
+1.4
+0.4
+15
+0.4
+0.9
+1.9
+1.4
+0.4
+20
+0.6
+1.1
+1.9
+1.5
+0.4
+25
+0.7
+1.2
+1.9
+1.6
+0.5
+30
+0.9
+1.3
+1.9
+1.6
+0.7
-20
∅ = 0
-0.7
-0.9
-1.3
-1.6
-0.6
∅ = 1
-0.9
-1.2
-1.7
-1.9
-1.2
-15
∅ = 0
-0.6
-0.8
-1.3
-1.6
-0.6
∅ = 1
-0.8
-1.1
-1.7
-1.9
-1.2
-10
∅ = 0
-0.6
-0.8
-1.3
-1.5
-0.6
∅ = 1
-0.8
-1.1
-1.7
-1.9
-1.3
-5
∅ = 0
-0.5
-0.7
-1.3
-1.6
-0.6
∅ = 1
-0.8
-1.5
-1.7
-1.9
-1.4
+5
∅ = 0
-0.6
-0.6
-1.4
-1.4
-1.1
∅ = 1
-0.9
-1.3
-1.8
-1.8
-2.1
+10
∅ = 0
-0.7
-0.7
-1.5
-1.4
-1.4
∅ = 1
-1.1
-1.4
-2.0
-1.8
-2.4
+15
∅ = 0
-0.8
-0.9
-1.7
-1.4
-1.8
∅ = 1
-1.2
-1.5
-2.2
-1.9
-2.8
+20
∅ = 0
-0.9
-1.2
-1.8
-1.4
-2.0
∅ = 1
-1.3
-1.7
-2.3
-1.9
-3.0
+25
∅ = 0
-1.0
-1.4
-1.9
-1.4
-2.0
∅ = 1
-1.4
-1.9
-2.4
-2.1
-3.0
+30
∅ = 0
-1.0
-1.4
-1.9
-1.4
-2.0
∅ = 1
-1.4
-2.1
-2.6
-2.2
-3.0
NOTE — Each slope of a duopitch canopy should be able to withstand forces using both the maximum and the minimum coefficients, and the whole canopy should be able to support forces using one slope at the maximum coefficient with the other slope at the minimum coefficient. For duopitch canopies the centre of pressure should be taken to act at the centre of each slope.
the canopy, there will be horizontal loads on the canopy due to the wind pressure on any fascia and to friction over the surface of the canopy. For any wind direction, only the greater of these two forces need be taken into account. Fascia loads should be calculated on the area of the surface facing the wind, using a force coefficient of 1.3. Frictional drag should be calculated using the coefficients given in 4.5.3.1.
NOTE — Tables 12 to 17 may be used to get internal and external pressure coefficients for pitches and troughed free roofs for some specific cases for which aspect ratios and roof slopes have been specified. However, while using Tables 12 to 17 any significant departure from it should be investigated carefully. No increase shall be made for local effects except as indicated.
e) Curved Roofs — For curved roofs, the external pressure coefficients shall be as given in Table 18. Allowance for local effects shall be made in accordance with Table 8.
Table 12 Pressure Coefficients (Top and Bottom) for Pitched Roofs, α = 30° [Clause 4.5.2.2 (d)]
NOTE — When the wind is blowing normal to the gable ends, C p e m a y be taken as equal to –0.7 for the full width of the roof over a length of l/2 from the gable ends and –0.5 for the remaining portion.
f) Pitched and Saw-Tooth Roofs of Multi-span Buildings — For pitched and saw-tooth roofs of multi-span buildings, the external average pressure coefficients and pressure concentration coefficients shall be as given
in Tables 19 and 20 respectively, provided that all spans shall be equal and the height to the eaves shall not exceed the span.
NOTE — Evidence on multi-span buildings is fragmentary. Any departure given in Tables 19 and 20 should be investigated separately.
Table 19 External Pressure Coefficients ( C p e ) for Pitched Roofs of Multi-span Buildings (All Spans Equal) with h > w ′
Roof Angle degrees
Wind Angle degrees
First Span
First Intermediate Span
Other Intermediate Span
End Span
Local Coefficient
a
b
c
d
m
n
x
z
510203045
0
-0.9-1.1-0.7-0.2+0.3
-0.6-0.6-0.6-0.6-0.6
-0.4-0.4-0.4-0.4-0.6
-0.3-0.3-0.3-0.3-0.4
-0.3-0.3-0.3-0.2-0.2
-0.3-0.3-0.3-0.3-0.4
-0.3-0.3-0.3-0.2-0.2
-0.3-0.4-0.5-0.5-0.5
-2.0
-1.5
Roof Angle degrees
Wind Angle degrees
Distance
h1
h2
h3
Up to 45
90
-0.8
-0.6
-0.2
Frictional drag: when wind angle = 0o horizontal forces due to frictional drag are allowed for in the above values; when wind angle = 90o allow for frictional drag in accordance with 4.5.3.1.
Table 20 External Pressure Coefficients ( C p e ) for Saw-Tooth Roofs of Multispan Buildings (All Spans Equal) with h > w ′
[Clause 4.5.2.2 (f)]
ROOF PLAN
SECTION
Wind Angle degrees-
First Span
First Intermediate Span
Other Intermediate Span
End Span
Local Coefficient
a
b
c
d
m
n
x
z
0180
+0.6-0.5
-0.7-0.3
-0.7-0.3
-0.4-0.3
-0.3-0.4
-0.2-0.6
-0.1-0.6
-0.3-0.1
-2.0
-1.5
Frictional drag: when wind angle - = 0o horizontal forces due to frictional drag are allowed for in the above values; when wind angle - = 90o allow for frictional drag in accordance with 4.5.3.1.
NOTE — Evidence on these buildings is fragmentary and any departures from the cases given should be investigated separately.
Position of Periphery, θ in degrees
Pressure Coefficient, Cpe
H/D = 25
H/D = 7
H/D = 1
0
1.0
1.0
1.0
15
0.8
0.8
0.8
30
0.1
0.1
0.1
45
-0.9
-0.8
-0.7
60
-1.9
-1.7
-1.2
75
-2.5
-2.2
-1.6
90
-2.6
-2.2
-1.7
105
-1.9
-1.7
-1.2
120
-0.9
-0.8
-0.7
135
-0.7
-0.6
-0.5
150
-0.6
-0.5
-0.4
165
-0.6
-0.5
-0.5
180
-0.6
-0.5
-0.4
Table 21 External Pressure Distribution Coefficients Around Cylindrical Structures [Clause 4.5.2.2 (h)]
g) Pressure Coefficients on Overhangs from Roofs — The pressure coefficients on the top overhanging portion of the roofs shall be taken to be the same as that of the nearest top portion of the non-pressure coefficients for the underside surface of the overhanging portions shall be taken as follows and shall be taken as positive if the overhanging portion is on the windward side:
1.25, if the overhanging slopes; downwards;
1.0, if the overhanging is horizontal; and
0.75, if the overhanging slopes upwards. For overhanging portions on sides other than windward side, the average pressure coefficients on the adjoining walls may be used.
h) Cylindrical Structures — For the purpose of calculating the wind pressure distribution
around a cylindrical structure of circular cross-section, the value of external pressure coefficients given in Table 21 may be used provided that the Raynolds number is greater than 10 000. They may be used for wind blowing normal to the axes of cylinders having axis normal to the ground plane (that is, chimneys and silos) and cylinders having their axis parallel to the ground plane (that is, horizontal tanks) provided that the clearance between the tank and the ground is not less than the diameter of the cylinder.
h is the height of a vertical cylinder or length of a horizontal cylinder. Where there is a free flow of air around both ends, h is to be taken as half the length when calculating h/D ratio. 1) –0.8, where h/D is not less than 0.3; and 2) –0.5, where h/D is less than 0.3.
k)
j) Roofs and Bottom of Cylindrical Related Structure — The external pressure coefficients for roofs and bottoms of cylindrical elevated structures shall be as given in Table 22 (see also Fig. 2).
The total resultant load (P) acting on the roof of the structure is given by the following formula:
P = 0. 7 8 5 D ² (C pi - C pe) p d
The resultant of P for roofs lies at 0.1 D from the centre of the roof on the windward side.
Combined Roofs and Roofs with a Sky Light — The average external pressure coefficients for combined roofs and roofs with a sky light are shown in Table 23.
1 5 h + 0. 2 D FOR 0. 2 < h / D < 2
(For force coefficient corresponding to shell portion see Table 23)
FIG. 2 EXTERNAL PRESSURE COEFFICIENTS ON THE UPPER ROOF SURFACE OF SINGULAR CIRCULAR STANDING ON THE GROUND
Table 22 External Pressure Coefficients for Roofs and Bottoms of Cylindrical Structures
[Clause 4.5.5.2 (j)]
Coefficient of External Pressure, C p e
Structure According to
Shape
a, b and c
d
H/D
Roof
(Z/H) -1
Roof
Bottom
0.5
-0.65
1.00
-0.75
-0.8
1.0
-1.00
1.25
-0.75
-0.7
2.0
-1.00
1.50
-0.75
-0.6
Total force acting on the roof of the structure, P = 0.785 D² (Cpi - Cpe)pd The resultant of P lies eccentrically, e = 0.1 D.
Table 23 External Pressure Coefficients, C p e for Combined Roofs and Roofs with a Sky Light [Clause 4.5.2.2 (k)]
a) Combined Roofs
Values of C p e
Portion
Direction 1 Direction 2
a
From the Diagram C<sub>pe</sub> = -0.5, h1/h2 < 1.5 -0.4
b
C<sub>pe</sub> = -0.7, h1/h2 > 1.5
c and d
See Table 5
e
See 4.5.2.2 (g)
Table 23 — Concluded
b) Roofs with a Sky Light
m) Grandstands — The pressure coefficients on the roof (top and bottom) and rear wall of a typical grandstand roof, which is open on three sides, is given in Table 24. The pressure coefficients are valid for a particular ratio of dimensions as specified in Table 24, but may be used for deviations up to 20 percent. In general, the maximum wind load occurs, when the wind is blowing into the open front of the stand causing positive pressure under the roof and negative pressure on the roof.
n) Upper Surface of Round Silos and Tanks — The pressure coefficients on the upper surface of round silos and tanks standing on ground shall be as given in Fig. 2.
p) Spheres — The external pressure coefficients for spheres shall be as given in Table 25.
-0.5
+0.8
-0.5
+0.3
135o
-0.4
-1.1
-0.7
-1.0
-0.9
-1.1
-0.9
-1.0
180o
-0.6
-0.3
-0.6
-0.3
-0.6
-0.3
-0.6
-0.3
45o
MR - Cp (top) = -2.0
45o
MR - Cp (bottom) = +1.0
Table 25 External Pressure Distribution Coefficients Around Spherical Structures [Clause 4.5.2.2 (p)]
C<sub>f</sub> = 0.5 for DV<sub>z</sub> < 7 = 0.2 for DV<sub>z</sub> > 7
Two design conditions shall be examined, one with an internal pressure coefficient of +0.2 and another with an internal pressure coefficient of –0.2.
The internal pressure coefficient is algebraically added to the external pressure coefficient and the analysis, which indicates greater distress of the member, shall be adopted. In most situations, a simple inspection of the sign of the external pressure will at once indicate the proper sign of the internal pressure coefficient to be taken for design.
NOTE — The terms normal permeability relates to the flow of air commonly afforded by the claddings not only through the open windows and doors, but also
through the slits round the closed windows and doors and through chimneys, ventilators and through the joints between roof coverings, the total open area being less than 5 percent of the area of the walls having the openings.
b) Building with medium and large openings — Buildings with medium and large openings may also exhibit either positive or negative internal pressure depending upon the direction of wind. Buildings with medium openings between about 5 to 20 percent of wall area shall be examined for an internal pressure coefficient of +0.5 and later with an internal pressure coefficient of –0.5, and the members shall be adopted. Buildings with large openings, that is, openings larger than
20 percent of the wall area shall be examined once with an internal pressure coefficient of +0.7 and again with an internal pressure coefficient of –0.7, and the analysis which produces greater distress on the members shall be adopted.
Buildings with one open side or openings exceeding 20 percent of wall area may be assumed to be subjected to internal positive pressure or suction similar to those for buildings with large openings. A few examples of buildings with one sided openings are shown in Fig. 3 indicating values of internal pressure coefficients with respect to direction of wind.
c) In buildings with roofs but no walls, the roofs will be subjected to pressure from both inside
and outside, and the recommendations shall be as given in 4.5.2.2.
For other buildings, the frictional drag has been indicated, where necessary, in the tables of pressure coefficients and force coefficients.
4.5.3.2 Force coefficients for clad buildings
a) Clad buildings of uniform section — The overall force coefficients for rectangular clad buildings of uniform section with flat roofs in uniform flow shall be as given in Fig. 4 and for other clad buildings of uniform section (without projections, except where otherwise shown) shall be as given in Table 26.
b) Buildings of circular shapes — Force coefficients for buildings of circular cross-section shall be as given in Table 27 (see Fig. 5 and Annex F).
c) Low walls and hoardings — Force coefficients for low walls and hoardings less than 15 m high shall be as given in Table 27 provided the height shall be measured from the ground to the top of the walls or hoarding, and provided that for walls or hoardings above
the ground the clearance between the wall or hoarding and the ground shall be not less than 0.25 times the vertical dimension of the wall or hoarding.
To allow for oblique winds the design shall also be checked for the net pressure normal to the surface varying linearly from a maximum of 1 . 7 C f at the up wind edge to 0.44 C f at the down wind edge.
The wind load on appurtenances and supports for hoardings shall be accounted for separately by using the appropriate net pressure coefficients. Allowance shall be made for the shielding effects of one element or another.
d) Solid circular shapes mounted on a surface — The force coefficients for solid circular shapes mounted on a surface shall be as given in Fig. 6.
z
1 Significant cross wind motions may be produced by vortex shedding if the natural frequency of the structure or structural element is equal to the frequency of the vortex shedding within the range of expected wind velocities. In such cases, further analysis should be carried out on the basis of references given in Note 8 of 4.6.1.
2 Unlined welded steel chimney stacks and similar structures are prone to excitation by vortex shedding.
3 Intensification of the effects of periodic vortex shedding has been reported in cases where two or more similar structures are located in close proximity, for example, at less than 20 b apart, where b is the dimension of the structure normal to the wind.
4 The formulae given in 4.6.2.1 (a) and 4.6.2.1 (b) are valid for infinitely long cylindrical structures. The value of S decreases slowly as the ratio of length to maximum transverse width decreases; the reduction being up to about half the value, if the structure is only three times higher than its width. Vortex shedding need not be considered if the ratio of length to maximum transverse width is less than 2.0.
k
1
k2
k3
where
V z = hourly mean wind speed in m/s at height z,
V b = regional basic wind speed in m/s (see Fig. 1),
k ₁ = probability factor (Table 4),
k 2 = terrain and height factor (Table 28), and
k 3 = topography factor (4.4.3.3).
p
z
G
where
F z = along wind load on the structure at any
height Z corresponding to strip area A e l ,
C f = force coefficient for the building,
A e = effective frontal area considered for the structure at height Z.
p z = design pressure at height Z due to mean hourly wind obtained as 0.6 V z 2 (N/m2), and
G=gust factormean loadpeak loadand is given by:
G=1+gfr[B(1+ϕ)2+βSE]
where
g f = peak factor defined as the ratio of the expected peak value to the root mean value of a fluctuating load, and
r = a roughness factor which is dependent on the size of the structure in relation to the ground roughness.
The value of ° g f r is given in Fig. 7.
FIG. 7 VALUES OF E f r AND L h
B is a background factor indicating a measure of the slowly varying component of the fluctuating wind load and is obtained from Fig. 8.
( S E )/( β ) is a measure of the resonant component of the fluctuating wind load.
E is a measure of the available energy in the wind stream at the natural frequency of the structure (see Fig. 9).
S is size reduction factor (see Fig. 10).
β is the damping coefficient (as a fraction of critical damping) of the structure (see Table 29).
φ = g r √( B ) 4 and is to be accounted only for buildings less than 75 m high in terrain category 4 and for buildings less than 25 high in terrain category 3, and is to be taken as zero in all other cases.
In Fig. 8 and 10,
λ=CzhCybandfo=VhCzfoh
where
C _ y = lateral correlation constant which may be taken as 10 in the absence of more precise load data;
C z = longitudinal correlation constant which may be taken as 12 in the absence of more precise load data;
b = breadth of a structure normal to the wind stream;
h = height of a structure;
V = hourly mean wind speed at height Z;
f o = natural frequency of the structure in the fundamental mode; and
L h = a measure of turbulence length scale (see Fig. 7)
Table 29Suggested Values of Damping Coefficient (Clause 4.7.3)
Nature of Structure
---
(1)
(2)
Welded steel structures
0.010
Bolted steel structures
0.020
Reinforced concrete structures
0.016
The peak acceleration along the wind direction at the top of the structure is given by the following formula:
a=(2πfo)2xˉgfrβSE
where
x = mean deflection at the position where the acceleration is required.
x
y
y
x
5.3.3.3 Design vertical earthquake load
When effects due to vertical earthquake loads are to be considered, the design vertical force shall be calculated in accordance with 5.3.4.5.
5.3.3.4 Combination for two or three component motion
5.3.3.4.1 When responses from the three earthquake components are to be considered, the responses due to each components may be combined using the assumption that when the maximum response from one component occurs, the responses from the other two component are 30 percent of their maximum. All possible combinations of the three components ( E L x , E L γ and E L _ Z ) including variations in sign (plus or minus) shall be considered. Thus, the response due earthquake force (EL) is the maximum of the following three cases:
a)b)c)±ELx±0.3ELy±0.3ELz±EL
Where x and y are two orthogonal directions and z is vertical direction.
5.3.3.4.2 As an alternative to the procedure in 5.3.3.4.1, the response (EL) due to the combined effect of the three components can be obtained on the basis of ‘square root of the sum of the square (SRSS)’ that is
E L = √ (E L x) ² + (E L y) ² + (E L z) ²
NOTE — The combination procedure of 5.3.3.4.1 and 5.3.3.4.2 apply to the same response quantity (say, moment in a column about its major axis, or storey shear in a frame) due to different components of the ground motion.
5.3.3.4.3 When two component motions (say one horizontal and one vertical, or only two horizontal) are combined, the equations in 5.3.3.4.1 and 5.3.3.4.2 should be modified by deleting the term representing the response due to the component of motion not being considered.
5.3.3.5 Increase in permissible stresses
5.3.3.5.1 Increase in permissible stresses in materials
When earthquake forces are considered along with other normal design forces, the permissible stresses in material, in the elastic method of design, may be increased by onethird. However, for steels having a definite yield stress, the stress be limited to the yield stress; for steels without a definite yield point, the stress will be limited to 80 percent of the ultimate strength or 0.2 percent proof stress, whichever is smaller; and that in prestressed concrete members, the tensile stress in the extreme fibres of the concrete may be permitted so as not to exceed two-thirds of the modulus of rupture of concrete.
5.3.3.5.2 Increase in allowable pressure in soils
When earthquake forces are included, the allowable bearing pressure in soils shall be increased as per Table 1, depending upon type of foundation of the structure and the type of soil.
In soil deposits consisting of submerged loose sands and soils falling under classification SP with standard penetration N values less than 15 in seismic Zones III, IV, V and less than 10 in seismic Zone II, the vibration caused by earthquake may cause liquefaction or excessive total and differential settlements. Such sites should preferably be avoided
while locating new settlements or important projects. Otherwise, this aspect of the problem needs to be investigated and appropriate methods of compaction or stabilization adopted to achieve suitable N values as indicated in Note 3 under Table 30. Alternatively, deep pile foundation may be provided and taken to depths well into the layer which is not likely to liquefy. Marine clays and other sensitive clays are also known to liquefy due to collapse of soil structure and will need special treatment according to site condition.
NOTE — Specialist literature may be referred for determining liquefaction potential of a site.
Table 30 Percentage of Permissible Increase in Allowable Bearing Pressure or Resistance of Soils(Clause 5.3.3.5.2)
Sl No.
Foundation
Type of Soil Mainly Constituting the Foundation
Type I Rock or Hard Soil:Well graded gravel and sand gravel mixtures with or without clay binder, and clayey sands poorly graded or sand clay mixtures (GB, CW, SB, SW and SC) ¹⁾ having ²⁾ above 30, where N is the standard penetration value
Type II Medium SoilsAll soils with N between 10 an 30, and poorly graded sands or gravelly sands with little or no fines (SP ¹⁾ ) with N>15
Type III Soft Soils: All soils other than SP ¹⁾ with N<10
(1)
(2)
(3)
(4)
(5)
i)
Piles passing through any soil but resting on solid type I
50
50
50
ii)
Piles not covered under item (i)
—
25
25
iii)
Raft foundations
50
50
50
iv)
Combined isolated RCC footing with tie beams
50
25
—
v)
Isolated RCC footing without tie beams, or unreinforced strip foundations
50
25
—
vi)
Well foundations
50
25
25
NOTES1 The allowable bearing pressure shall be determined in accordance with good practice [6-1(6)].2 If any increase in bearing pressure has already been permitted for forces other than seismic forces, the total increase in allowable bearing pressure when seismic force is also included shall not exceed the limits specified above.3 Desirable minimum field values of N — If soils of smaller N-values are met, compacting may be adopted to achieve these values or deep pile foundations going to stronger strata should be used.4 The values of N (corrected values) are at the founding level and the allowable bearing pressure shall be determined in accordance with good practice [6-1(6)].
Seismic Zone Level m
Depth Below Ground
N-Values
Remark
III, IV and V
≤5
15
For values of depths between 5 m and 10 m, linear interpolation is recommended.
≥10
25
II (for important structures only)
≤5
15
≥10
20
5 The piles should be designed for lateral loads neglecting lateral resistance of soil layers liable to liquefy.6 Accepted standard [6-1(7)] and good practice [6-1(8)] may also be referred.7 Isolated R.C.C. footing without tie beams, or unreinforced strip foundation shall not be permitted in soft soils with N<10.
See accepted standard [6-1(7)].
See good practice [6-1(8)].
a
Provided that for any structure with T ≥ 0 . 1 sec, the value of A h will not be less than Z/2 whatever be the value of I/R
where
Z = Zone factor given in Table 31, is for the maximum considered earthquake (MCE) and service life of structure in a zone. The factor 2 in the denominator of > is used so as to reduce the maximum considered earthquake (MCE) zone factor to the factor for design basis earthquake (DBE).
Zone factor for some important towns are given at Annex J.
I = Importance factor, depending upon the functional use of the structures, characterised by hazardous consequences of its failure, post-earthquake functional needs, historical value, or economic importance (Table 35).
R = Response reduction factor, depending on the perceived seismic damage performance of the structure, characterized by ductile or brittle deformations. However, the ratio (I/R) shall not be greater than 1.0 (Table 36). The values of R for buildings are given in Table 36.
S /g = Average response acceleration coefficient for rock or soil sites as given by Fig. 12 and Table 32 based on appropriate natural periods and damping of the structure. These curves represent free field ground motion.
NOTE — For various types of structures, the values of Importance Factor I, Response Reduction Factor R, and damping values are given in the respective parts of this standard. The method (empirical or otherwise) to calculate the natural periods of the structure to be adopted for evaluating S /g is also given in the respective parts of this Code.
Table 31Zone Factor, Z
Seismic Zone
II
III
IV
V
Seismic Intensity
Low
Moderate
Severe
Very Severe
Z
0.10
0.16
0.24
0.36
5.3.4.3 Where a number of modes are to be considered
for dynamic analysis, the value of A h as defined in 5.3.4.2 for each mode shall be determined using the natural period of vibration of that mode.
5.3.4.4 For underground structures and foundations at depths of 30 m or below, the design horizontal acceleration spectrum value shall be taken as half the value obtained from 5.3.4.2. For structures and foundations placed between the ground level and 30 m depth, the design horizontal acceleration spectrum value shall be linearly interpolated between A h and 0 . 5 A h , where A h is as specified in 5.3.4.2.
5.3.4.5 The design acceleration spectrum for vertical motions, when required, may be taken as two-thirds of the design horizontal acceleration spectrum specified in 5.3.4.2.
Figure 12 shows the proposed 5 percent spectra for rocky and soils sites and Table 32 gives the multiplying factors for obtaining spectral values for various other dampings.
For Rocky, or hard soil sites
gSa
For Medium soil sites
gSa
For Soft soil sites
gSa
Table 32Multiplying Factors for Obtaining Values for Other Damping
(Clause 5.3.4.2)
Damping percent
0
2
5
7
10
15
20
25
30
Factors
3.20
1.40
1.00
0.90
0.80
0.70
0.60
0.55
0.50
5.3.4.6 In case design spectrum is specifically prepared for a structure at a particular project site, the same may be used for design at the discretion of the project authorities.
s
+
μw
2
≤
sokh
=0.085h0.75
for RC Frame Buildingfor Steel Frame Building
where
h = Height of building, in metres. This excludes the basement storeys, where basement walls are connected with the ground floor deck or fitted between the building columns. But, it includes the basement storeys, when they are not so connected.
5.4.6.2 The approximate fundamental natural period of vibration ( T a ) , in seconds, of all other buildings, including moment-resisting frame buildings with brick infill panels, may be estimated by the empirical expression:
Ta=d0.09h
where
h = Height of building, in metres, as defined in 5.4.6.1; and
d = Base dimension of the building at the plinth level, in metres; and along the considered direction of the lateral force.
∑j=1nWjhj2
Wihi2
where
Q = Design lateral force at floor i,
W i = Seismic weight of floor i,
hi = Height of floor i measured from base, and
n = Number of storeys in the building is the number of levels at which the masses are located.
5.4.7.2 Distribution of horizontal design lateral force to different lateral force resisting elements
5.4.7.2.1 In case of buildings whose floors are capable of providing rigid horizontal diaphragm action, the total
shear in any horizontal plane shall be distributed to the various vertical elements of lateral force resisting system, assuming the floors to be infinitely rigid in the horizontal plane.
5.4.7.2.2 In case of building whose floor diaphragms cannot be treated as infinitely rigid in their own plane, the lateral shear at each floor shall be distributed to the vertical elements resisting the lateral forces, considering the in-plane flexibility of the diaphragms.
1 A floor diaphragm shall be considered to be flexible, if it deforms such that the maximum lateral displacement measured from the chord of the deformed shape at any point of the diaphragm is more than 1.5 times the average displacement of the entire diaphragm.
2 Reinforced concrete monolithic slab-beam floors or those consisting of Prefabricated/Precast elements with topping reinforced screed can be taken a rigid diaphragms.
5.4.8.4.3 Analysis of building subjected to design forces
The building may be analysed by accepted principles of mechanics for the design forces considered as static forces.
5.4.8.4.4 Modal Combination
The peak response quantities (for example, member forces, displacements, storey forces, storey shears and base reactions) shall be combined as per Complete Quadratic Combination (CQC) method.
λ=i=1∑rj=1∑rλiρijλj
where
r = Number of modes being considered,
λi = Response quantity in i th mode,
i = Cross-modal coefficient i (including sign), and
λj = Response quantity in mode j (including sign).
ρij=(1−β2)2+4ς2β(1+β)28ς2(1+β)β1.5
= Modal damping ratio (in fraction) as specified in 5.4.8.2.1,
β = Frequency ratio = ω /ω
ω = circular frequency in ith mode, and
ω = circular frequency in jth mode.
Alternatively, the peak response quantities may be combined as follows:
a) If the building does not have closely-spaced modes, then the peak response quantity (λ) due to all modes considered shall be obtained as
λ=K=1∑r(λK)2
where
λ = Absolute value of quantity in mode k.
b) If the building has a few closely-spaced modes (see 5.3.3.2), then the peak response quantity (λ*) due to these modes shall be obtained as
λ∗=c∑λc
where the summation is for the closely-spaced modes only. This peak response quantity due to the closely spaced modes ( λ ∗ ) is then combined with those of the remaining well-separated modes by the method described in 5.4.8.4.4 (a).
5.4.8.4.5 Buildings with regular, or nominally irregular, plan configurations may be modelled as a system of masses lumped at the floor levels with each mass having one degree of freedom, that of lateral displacement in the direction under consideration. In such a case, the following expressions shall hold in the computation of the various quantities:
a) Modal Mass — The modal mass ( M k ) of mode k is given by
MK=g∑i=1NWi(ϕik)2[∑i=1NWiϕik]2
where
g = Acceleration due to gravity,
φik = Mode shape coefficient at floor i in mode k, and
W i = Seismic weight of floor i.
b) Modal Participation Factors — The modal participation factor ( P _ K ) of mode k is given by
PK=∑i=1nWi(ϕik)2∑i=1nWiϕik
c) Design lateral Force at Each Floor in Each Mode — The peak lateral force ( Q i k ) at floor i in mode k is given by
Q ik = A K φik P K W i
where
A _ K = Design horizontal acceleration spectrum value as per 5.3.4.2 using the natural period of vibration ( T k ) of mode k.
c) Storey Shear Forces in Each Mode — The peak shear force ( V i K ) acting in storey i in mode k is given by
ViK=j=i+1∑nQiK
d) Storey Shear Forces due to All Modes Considered — The peak storey shear force ( V i ) in storey i due to all modes considered is obtained by combining those due to each mode in accordance with 5.4.8.4.4.
e) Lateral Forces at Each Storey due to All Modes Considered — The design lateral forces, F r o o f and F i ° at roof and at floor i:
Froof=VroofandFi=Vi−Vi+1
{1.5oresi+0.05biesi−0.05bi
whichever of these gives the more severe effect in the shear of any frame where
e d i = static eccentricity at floor i defined as the distance between centre of mass and centre of rigidity and
b i = floor plan dimension of floor i, perpendicular to the direction of force.
NOTE — The factor 1.5 represents dynamic amplification factor, while the factor 0.05 represents the extent of accidental eccentricity.
5.4.9.3 In case of highly irregular buildings analysed according to 5.4.8.4.5, additive shears will be superimposed for a statically applied eccentricity of ± 0.05b with respect to the centre of rigidity.
Reduced imposed load specified in 3 for the design of supporting structures should not be applied in combination with earthquake forces.
7 Other loads and accidental load combination not included should be dealt with appropriately.
8 Crane load combinations are covered in 3.6.4.
b) Cyclone and Flood Risk Prone — Districts which have cyclone and flood prone areas. Here floods can occur separately from cyclones, but simultaneous also along with prossibility of storm surge too.
c) Earthquake, Cyclone and Flood Risk Prone — Districts which have earthquake Zone of intensity 7 or more, cyclone prone as well as flood prone (protected or unprotected) areas. Here the three hazards can occur separately and also simultaneously as in (a) and (b) above but earthquake and cyclone will be assumed to occur separately only.
d) Earthquake and Cyclone Risk Prone — Districts which have earthquake zone of intensity 7 or more and prone to cyclone hazard too. The two will be assumed to occur separately.
Based on the approach given above, the districts with multi-hazard risk are given in Annex M.
9.3 Use of the List of the District with Multi-hazard Risk
The list provides some ready information for use of the authorities involved in the task of disaster mitigation, preparedness and preventive action. This information gives the district which are prone to high risk for more than one hazard. This information will be useful in establishing the need for developing housing design to resist the such multi-hazard situation.
The occurrence of which, with a significant value, is unlikely on a given structure over the period of time under consideration, and also in most cases, is of short duration. The occurrence of an accidental load could, in many cases, be expected to cause severe consequences, unless special measures are taken.
The accidental loads arising out of human action include the following:
a) Impacts and collisions,
b) Explosions, and
c) Fire.
Characteristic of the above stated loads are that they are not a consequence of normal use and that they are undesired, and that extensive effects are made to avoid them. As a result, the probability of occurrence of an accidental load is small whereas the consequences may be severe.
The causes of accidental loads may be:
a) inadequate safety of equipment (due to poor design or poor maintenance); and
b) wrong operation (due to insufficient teaching or training, indisposition, negligence or unfavouable external circumstances).
In most cases, accidental loads only develop under a combination of several unfavourable occurrence. In practical applications, it may be necessary to neglect the most unlikely loads. The probability of occurrence of accidental loads, which are neglected, may differ for different consequences of a possible failure. A data base for a detailed calculation of the probability will seldom be available.
7.6.1 Impact and Collisions
7.6.1.1 General
During an impact, the kinetic impact energy has to be absorbed by the vehicle hitting the structure and by the structure itself. In an accurate analysis, the probability of occurrence of an impact with a certain energy object hitting the structure and the structure itself at the actual place must be considered. Impact energies for dropped object should be based on the actual loading capacity and lifting height.
Common sources of impact are:
a) Vehicles;
b) Dropped objects from cranes, fork lifts, etc;
c) Cranes out of control, crane failures; and
d) Flying fragments.
The codal requirements regarding impact from vehicles and cranes are given in 7.6.1.2 and 7.6.1.3.
7.6.1.2 Collisions between vehicles and structural elements
In road traffic, the requirement that a structure shall be able to resist collision may be assumed to be fulfilled if it is demonstrated that the structural element is able to stop a fictitious vehicle, as described below. It is assumed that the vehicle strikes the structural element at a height of 1.2 m in any possible direction and at a speed of 10 m/s (36 km/h).
The fictitious vehicle shall be considered to consist of two masses m 1 and m 2 which during compression of the vehicle, produce an impact force increasing uniformly from zero, corresponding to the rigidities C 1 and C 2 ∗ It is assumed that the mass m 1 is broken completely before the breaking of mass m 2 begins.
The following numerical values should be used:
m1=400kg,C1
m2=12000kg,C2
NOTE — The described fictitious collision corresponds in the case of a non-elastic structural element to a maximum static force of 630 kN for the mass m i and 600 kN for the mass m irrespective of the elasticity, it will therefore be on the safe side to assume the static force to be 630 kN.
In addition, breaking of the mass m 1 will result in an impact wave, the effect of which will depend, to a great extent, on the kind of structural element concerned. Consequently, it will not always be sufficient to design for the static force.
7.6.1.3 Safety railings
With regard to safety, railings put up to protect structures against collision due to road traffic, it should be shown that the railings are able to resist the impact as described in 7.6.1.2.
NOTE — When a vehicle collides with safety railings, the kinetic energy of the vehicle will be absorbed partly by the deformation of the railings and partly by the deformation of the vehicle. The part of the kinetic energy which the railings should be able to absorb without breaking down may be determined on the basis of the assumed rigidity of the vehicle during compression.
7.6.1.4 Crane impact load on buffer stop
The basic horizontal load P y (tones), acting along the crane track produced by impact of the crane on the buffer stop, is calculated by the following formula:
P y = M V ² / f
where
V = Speed at which the crane is travelling at the moment of impact (assumed equal to half the nominal value) (m/s).
f = Maximum shortening of the buffer, assumed equal to 0.1 m for light duty, medium-duty and heavy-duty cranes with flexible load suspension and loading capacity not exceeding 50 t, and 0.2 m in every other cranes.
M = Reduced crane mass, ( t . s 2 / m ) ; and is obtained by the formula:
M=g1[2P
where
g = Acceleration due to gravity (9.81 m/s2);
P h = Crane bridge weight (t);
P t = Crab bridge weight (t);
Q = Crane loading capacity (t);
k = Coefficient, assumed equal to zero for cranes with flexible load suspension and to one for cranes with rigid suspension;
L k = Crane span (m); and
l = Nearness of crab (m).
7.6.2 Explosions
7.6.2.1 General
Explosions may cause impulsive loading on a structure. The following types of explosions are particularly relevant:
a) Internal gas explosions which may be caused by leakage of gas piping (including piping outside the room), evaporation from volatile liquids or unintentional evaporation from surface material (for example, fire);
b) Internal dust explosions;
c) Boiler failure;
d) External gas cloud explosions; and
e) External explosions of high explosives (TNT, dynamite).
The codal requirement regarding internal gas explosions is given in 7.6.2.2.
7.6.2.2 Explosion effect in closed rooms
Gas explosion may be caused, for example by leaks in gas pipes (inclusive of pipes outside for room), evaporation from volatile liquids or unintentional evaporation of gas from wall sheathings (for example, caused by fire).
NOTES
1 The effect of explosions depends on the exploding medium,
the concentration of the explosion, the shape of the room, possibilities of ventilation of the explosion, and the ductility and dynamic properties of the structure. In rooms with little possibility for relief of the pressure from the explosion, very large pressures may occur.
Internal over pressure from an internal gas explosion in rooms of sizes comparable to residential rooms and with ventilation areas consisting of window glass breaking at a pressure of 4 kN/m2 (3-4 mm machine made glass) may be calculated from the following method:
a) The over pressure is assumed to depend on a factor A/V, where A is the total windows area in m2 and V is the volume in m3 of the room considered;
b) The internal pressure is assumed to act simultaneously upon all walls and floors in one closed room; and
c) The action q o may be taken as static action.
If account is taken of the time curve of the action, the schematic correspondence between pressure and time is assumed (Fig. 16), where t 1 is the time from the start of combustion until maximum pressure is reached and t 2 is the time from maximum pressure to the end of combustion. For t 1 and t 2 ° the most unfavourable values should be chosen in relation to the dynamic properties of the structures. However, the values should be chosen within the intervals as given in Fig. 17.
2 Figure 16 is based on tests with gas explosions in room corresponding to ordinary residential flats and should, therefore, not be applied to considerably different conditions. The figure corresponds to an explosion caused by town gas and it might, therefore, be somewhat on the safe side in rooms where there is only the possibility of gases with a lower rate of combustion.
7.6.3 Vertical Load on Air Raid Shelters
7.6.3.1 Characteristic values
As regards buildings in which the individual floors are acted upon by a total characteristic imposed action of up to 5.0 kN/m2, vertical actions on air raid shelters generally located below ground level, for example, basement, etc, should be considered to have the following characteristic values:
Buildings up to 2 storeys
28 kN/m²
Buildings with 3-4 storeys
34 kN/m²
Buildings with more than 4 storeys
41 kN/m²
Buildings of particularly stable constructionirrespective of the number of storeys
28 kN/m²
In the case of buildings with floors that are acted upon by a characteristic imposed action larger than 5.0 kN/m2, the above values should be increased by the difference between the average imposed action on all storeys above the one concerned and 5.0 kN/m2.
FIG. 16 SKETCH SHOWING RELATION BETWEEN PRESSURE AND TIME
FIG. 17 SKETCH SHOWING TIME INTERVAL AND PRESSURE
1 By storeys it is understood, every utilizable storey above the shelter.
2 By buildings of a particular stable construction, it is understood, buildings in which the load-bearing structures are made from reinforced in-situ concrete.
7.6.4 Fire
7.6.4.1 General
Possible extraordinary loads during a fire may be considered as accidental actions. Examples are loads from people along escape routes and loads on another structure from structure failing because of a fire.
7.6.4.2 Thermal effects during fire
The thermal effect during fire may be determined from one of the following methods:
a) the time-temperature curve and the required fire resistance (minutes), and
b) an energy balance method.
If the thermal effect during fire is determined from an energy balance method, the fire load is taken to be:
q = 1 2 t b
where
q = Fire action (kJ per m2 floor), and
t = Required fire resistance (minutes) [see 6-1(11)].
NOTE — The fire action is defined as the total quantity of heat produced by complete combustion of all combustible material in the fire compartment, inclusive of stored goods and equipment together with building structures and building materials.
7.7 Vibrations
For general details on loads due to vibrations, reference may be made to Annex L.
7.8 Other Loads
Other loads not included in the Section, such as special loads due to technical process, moisture and shrinkage effects, etc, should be taken into account where stipulated by building design codes or established in accordance with the performance requirement of the structure.
7.9 For additional information regarding loads, forces and effects about cyclone resistant buildings and landslide control aspects, reference may be made to good practices [6-1(12)] and 6-1(13)] respectively.
Annex B(Clause 4.2)
Notations
A = Surface area of a structure or part of a structure
A e = Effective frontal area
A z = An area at height Z
b = Breadth of a structure or structural member normal to be wind stream in the horizontal plane
C f = Force coefficient/drag coefficient
C f n = Normal force coefficient
C f t = Transverse force coefficient
C f ′ = Frictional drag coefficient
C = Pressure coefficient
C p e = External pressure coefficient
C p i = Internal pressure coefficient
d = Depth of a structure or structural member parallel to wind stream
D = Diameter of cylinder
F = Force normal to the surface
F n = Normal force
F t = Transverse force
F’ = Frictional force
h = Height of structure above mean ground level
h _ x = The height of development of a velocity profile at a distance x down wind from a change in terrain category
k1 k2 = Multiplication factors k3
K = Multiplication factor
l = Length of the member or greater horizontal dimension of a building
p d = Design wind pressure
p z = Design wind pressure at height Z
p e = External pressure
p i = Internal pressure
R e = Reynolds number
S = Strouhal number
V b = Regional basic wind speed
V b = Mean hourly wind speed corresponding to
V z = Design wind velocity at height Z
V z = Hourly mean wind speed at height Z
w = Lesser horizontal dimension of a building or a structural member
w´ = Bay within multi-bay buildings
x = Distance down wind from a change in terrain category
The pressure may be applied solely in one room or in more rooms at the same time. In the latter case, all rooms are incorporated in the volume V. Only windows or other similarly weak and light weight structural elements may be taken to be ventilation areas even though certain limited structural parts break at pressures less than q o ′
Figure 16 is given purely as guide and probability of occurrence of an explosion should be checked in each case using appropriate values.