6.1 All structural members, assemblies or framework in a building shall be capable of sustaining, without
exceeding the limits of stress specified, the worst combination of all loadings. A fundamental aspect of design will be to determine the forces to which the structure/structural element might be subjected to, starting from the roof and working down to the soil by transferring the forces through various components and connections. Accepted principles of mechanics for analysis and specified design procedures shall be applied (see Part 6 ‘Structural Design, Sub-section 3A Timber’).
6.2 Unlike timber, bamboo properties do not relate well to species, being dependent among other factors, on position of the culm, geographic location and age. The practice in timber engineering is to base designs on safe working stresses and the same may be adopted to bamboo with the limitations that practical experience rather than precise calculations generally govern the detailing.
6.3 Net Section
It is determined by passing a plane or a series of connected planes transversely through the members. Least net sectional area is used for calculating load carrying capacity of a member.
6.4 Loads
6.4.1 The loads shall be in accordance with Part 6 ‘Structural Design, Section 1 Loads, Forces and Effects’.
6.4.2 The worst combination and location of loads shall be considered for design. Wind and seismic forces shall not be considered to act simultaneously.
6.5.1 Main structural components in bamboo may include roof and floor diaphragms, shear walls, wall panellings, beams, piles, columns, etc. Both from the point of view of capacity and deformation, trusses and framed skeltons are much better applications of bamboo.
6.5.2 Schematization of Bamboo as a Structural Material
This shall be based on the principles of engineering mechanics involving the following assumptions and practices:
a) The elastic behaviour of bamboo, till failure; (plastic behaviour being considered insignificant);
b) Bamboo culms are analysed on mean wall thickness basis as hollow tube structure (not perfectly straight) member on mean diameter basis;
c) The structural elements of bamboo shall be appropriately supported near the nodes of culm as and where the structural system demands. The joints in the design shall be located near nodes; and
d) Bamboo structures be designed like any other conventional structural elements taking care of details with regards to supports and joints; they shall be considered to generally act as a hinge, unless substantiating data justify a fixed joint.
6.6 Flexural Members
6.6.1 All flexural members may be designed using the principles of beam theory.
6.6.2 The deflection shall be within the prescribed limits. The tendency of bamboo beams to acquire a large deflection under long continuous loadings due to possible plastic flow, if any shall be taken care of. Permanent load may be doubled for calculation of deflection under sustained load (including creep) in case of green bamboo having moisture content exceeding 15 percent.
6.6.3 Bamboo is not naturally reinforced for shear, because, compared to reinforced cement concrete beam, the stirrups are located on the longitudinal instead of the transverse direction in a bamboo culm.
6.6.4 The moment of inertia, I shall be determined as follows:
a) The outside diameter and the wall thickness shall be measured at both ends, correct up to 1 mm for diameter of culm and 0.1 mm for the wall thickness. (For each cross-section the diameter shall be taken twice, in direction perpendicular to each other and so the wall thickness shall be taken as four times, in the same places as the diameter has been taken twice.)
b) With these values the mean diameter and the mean thickness for the middle of the beam shall be calculated and moment of inertia determined.
6.6.4.1 The maximum bending stress shall be calculated and compared with the allowable stress.
6.6.4.2 The deflection shall be calculated, and compared with the allowable deflection. The initial curvature shall be considered in the calculation of the deflection.
6.6.4.3 The shear stress in the neutral layer at the small end shall be checked, if the length of the beam is less
than 25 times the diameter at that end. For shear checks, conventional design procedure in accordance with Part 6 ‘Structural Design, Sub-section 3A Timber’ shall be followed.
NOTE — The basic shear stress values (N/mm2) for at least five species of bamboo in split form in green condition have been determined as under:
Bambusa pallida 9.77
B. Vulgaris 9.44
Dedrocalamus giganteous 8.86
D.hamiltonii 7.77
Oxytenanthera abyssinicia 11.2
6.6.4.4 Forces acting on a beam, being loads or reaction forces at supports, shall act in nodes or as near to nodes as by any means possible.
6.7 Bamboo Columns (Predominantly Loaded in Axial Direction)
6.7.1 Columns and struts are essential components sustaining compressive forces in a structure. They transfer load to the supporting media.
6.7.2 Design of columns shall be based on one of the following two criteria:
a) Full scale buckling tests on the same species, size and other relevant variables.
b) Calculations, based on the following:
-
The moment of inertia shall be as per 6.6.4.
-
For bamboo columns the best available straight bamboo culms shall be selected. Structural bamboo components in compression should be kept under a slenderness ratio of 50.
-
The bending stresses due to initial curvature, eccentricities and induced deflection shall be taken into account, in addition to those due to any lateral load.
6.7.3 Buckling calculation shall be according to Euler, with a reduction to 90 percent of moment of inertia, to take into account the effect of the taper provided it is not less than 0.6 percent.
6.7.4 For strength and stability, larger diameter thick walled sections of bamboo with closely spaced nodes shall be used. Alternatively, smaller sections may be tied together as a bundle-column.
6.8 Assemblies, Roof Trusses
6.8.1 Elements in structure are generally built-up in the form of assembled members for which a triangle is a simple figure of stability. Besides sloped chords, parallel chord construction is also appropriate as external profile.
6.8.2 A truss is essentially a plane structure which is very stiff in the plane of the members, that is the plane in which it is expected to carry load, but very flexible in every other direction. Roof truss generally consists of a number of triangulated frames, the members of which are fastened at ends and the nature of stresses at joints are either tensile or compressive and designed as pin-ended joints (see Fig. 2A). Bamboo trusses may also be formed using bamboo mat board or bamboo mat-veneer composite or plywood gusset (see Fig. 2B).
6.8.3 Truss shall be analysed from principles of structural mechanics for the determination of axial forces in members. For the influence of eccentricities, due allowance shall be made in design.
6.8.4 The truss height shall exceed 0.15 times the span in case of a triangular truss (pitched roofing) and 0.10 times the span in case of a rectangular (parallel) truss.
6.8.5 For members in compression, the effective length for in-plane strength verification shall be taken as the distance between two adjacent points of contraflexure. For fully triangulated trusses, effective length for simple span members without especially rigid end-connection shall be taken as the span length.
6.8.6 For strength verification of members in compression and connections, the calculated axial forces should be increased by 10 percent.
6.8.7 The spacing of trusses shall be consistent with use of bamboo purlins (2 m to 3 m).
6.8.8 The ends in open beams, joists, rafters, purlins shall be suitably plugged. Bamboo roof coverings shall be considered as non-structural in function. The common roof covering shall include bamboo mat board, bamboo mat corrugated sheet, bamboo tiles/ strings, plastered bamboo reeds, thatch, corrugated galvanized iron sheeting, plain clay tiles or pan tiles, etc.