4.1 Species of Timber
The species of timber recommended for structural purposes are given in Table 1.
4.1.1 Grouping
Species of timber recommended for constructional purposes are classified in three groups on the basis of their strength properties, namely, modulus of elasticity (E) and extreme fibre stress in bending and tension (fb).
The characteristics of these groups are as given below:
Group A — E above 1 2 . 6 × 1 0 3 N / m m 2 and f b above 18.0 N/mm2.
Group B — E above 9 . 8 × 1 0 3 N/mm2 and up to 1 2 . 6 × 1 0 3 N / m m 2 and f b above 12.0 N/mm2 and up to 18.0 N/mm2.
Group C — E above 5 . 6 × 1 0 3 N / m m 2 and up to 9 . 8 × 1 0 3 N / m m 2 and f b above 8.5 N/mm2 and up to 12.0 N/mm2.
NOTE — Modulus of elasticity given above is applicable for all locations and extreme fibre stress in bending is for inside location.
4.1.2 Timber species may be identified in accordance with good practice [6-3A(3)].
4.2 The general characteristics like durability and treatability of the species are also given in Table 1. Species of timber other than those recommended in Table 1 may be used, provided the basic strength properties are determined and found in accordance with 4.1.1.
NOTE — For obtaining basic stress figures of the unlisted species, reference may be made to the Forest Research Institute, Dehra Dun.
4.3 The permissible lateral strength (in double shear) of mild steel wire shall be as given in Table 2 and Table 3 for different species of timber.
4.4 Moisture Content in Timber
The permissible moisture content of timber for various positions in buildings shall be as given in Table 4.
4.5 Sawn Timber
4.5.1 Sizes
Preferred cut sizes of timber for use in structural components shall be as given in Tables 5 to 7.
4.5.2 Tolerances
Permissible tolerances in measurements of cut sizes of structural timber shall be as follows:
a) For width and thickness:
-
Up to and including 100 mm + 3 - 0 mm
-
Above 100 mm
b) For length + 1 0 - 0 m m