3.1 This clause covers imposed loads (live loads) to be assumed in the design of buildings. The imposed loads specified herein are minimum loads which should be taken into consideration for the purpose of structural safety of buildings.
NOTE — This Section does not cover detailed provisions for loads incidental to construction and special cases of vibration, such as moving machinery, heavy acceleration from cranes, hoists and the like. Such loads shall be dealt with individually in each case.
3.2 Terminology
3.2.1 For the purpose of imposed loads specified herein, the following definitions shall apply:
3.2.1.1 Assembly Buildings — These shall include any building or part of a building where groups of people congregate or gather for amusement, recreation, social, religious, patriotic, civil, travel and similar purposes; for example, theatres, motion picture houses, assembly halls, city halls, marriage halls, town halls, auditoria, exhibition halls, museums, skating rinks, gymnasiums, restaurants (also used as assembly halls), place of worship, dance halls, club rooms, passenger stations and terminals of air, surface and other public transportation services, recreation piers and stadia, etc.
3.2.1.2 Business Buildings — These shall include any building or part of a building, which is used for transaction of business (other than that covered by mercantile buildings); for keeping of accounts and records for similar purposes; offices, banks, professional establishments, court houses, and libraries shall be classified in this group so far as principal
function of these is transaction of public business and the keeping of books and records.
3.2.1.3 Dwellings — These shall include any building or part occupied by members of single/multi-family units with independent cooking facilities. These shall also include apartment houses (flats).
5
3.2.1.4 Educational Buildings — These shall include any building used for school, college or day-care purposes involving assembly for instruction, education or recreation and which is not covered by assembly buildings.
3.2.1.5 Imposed Load — The load assumed to be produced by the intended use or occupancy of a building including the weight of movable partitions, distributed and concentrated loads, loads due to impact and vibration, and dust loads but excluding wind, seismic, snow and other loads due to temperature changes, creep, shrinkage, differential settlement, etc.
3.2.1.6 Industrial Buildings — These shall include any building or a part of a building or structure, in which products or materials of various kinds and properties are fabricated, assembled or processed like assembly plants, power plants, refineries, gas plants, mills, dairies, factories, workshops, etc.
3.2.1.7 Institutional Buildings — These shall include any building or a part thereof, which is used for purposes, such as, medical or other treatment in case of persons suffering from physical and mental illness, disease or infirmity; care of infants, convalescents or aged persons and for penal or correctional detention in which the liberty of the inmates is restricted. Institutional buildings ordinarily provide sleeping accommodation for the occupants. It includes hospitals, sanitoria, custodial institutions or penal institutions like jails, prisons and reformatories.
3.2.1.8 Occupancy or Use Group — The principal occupancy for which a building or part of a building is used or intended to be used; for the purpose of classification of a building according to occupancy, an occupancy shall be deemed to include subsidiary occupancies which are contingent upon it. The occupancy classification is given in the following groups.
3.2.1.9 Office Buildings — The buildings primarily to be used as an office or for office purposes; ‘office purposes’ include the purpose of administration, clerical work, handling money, telephone and telegraph operating, and operating computers, calculating machines, ‘clerical work’ includes writing, book-keeping, sorting papers,
typing, filing, duplicating, punching cards or tapes, drawing of matter for publication and the editorial preparation of matter for publication.
3.2.1.10 Mercantile Buildings — These shall include any building or a part of a building which is used as shops, stores, market for display and sale of merchandize either wholesale or retail. Office, storage and service and facilities incidental to the sale of merchandize and located in the same building shall be included under this group.
3.2.1.11 Residential Buildings — These shall include any building in which sleeping accommodation is provided for normal residential purposes with or without cooking or dining or both facilities (except buildings under institutional buildings). It includes one or multi-family dwellings, apartment houses (flats), lodging or rooming houses, restaurants, hostels, dormitories and residential hotels.
3.2.1.12 Storage Buildings — These shall include any building or part of a building used primarily for the storage or sheltering of goods, wares or merchandize, like warehouses, cold storages, freight depots, transity sheds, store houses, garages, hangers, truck terminals, grain elevators, barns and stables.
Part 6 Section 1Loads, Forces and Effects
IS 875 (Part 2) : 1987 Code of practice for design loads (other than earthquake) for buildings and structures: Part 2 Imposed loads (second revision)
IS 875 (Part 3) : 1988 Code of practice for design loads (other than earthquake) for buildings and structures: Part 3 Wind loads (second revision)
IS 875 (Part 4) : 1987 Code of practice for design loads (other than earthquake) for buildings and structures: Part 4 Snow loads (second revision)
IS 875 (Part 5) : 1987 Code of practice for design loads (other than earthquake) for buildings and structures: Part 5 Special loads and load combinations (second revision)
This Section has to be read together with Sections 2 to 7 of Part 6 ‘Structural Design’.
A reference to SP 64 (S&T) : 2001 ‘Explanatory Handbook on Indian Standard Code of practice for design loads (other than earthquake) for buildings and structures: Part 3 Wind loads IS 875 (Part 3) : 1987’ may be useful. This publication gives detailed background information on the provisions for wind loads and also the use of these provisions for arriving at the wind loads on buildings and structures while evaluating their structural safety.
Reference may also be made to the Vulnerability Atlas of India, 1997 and Landslide Hazard Zonation Atlas of India, 2003 Building Materials and Technology Promotion Council, Ministry of Urban Development and Poverty Alleviation, Government of India. The vulnerability Atlas contains information pertaining to each State and Union Territory of India, on (a) seismic hazard map, (b) cyclone, and wind map, (c) flood prone area map, and (d) housing stock vulnerability table for each district indicating for each house type the level of risk to which it could be subjected. The Atlas can be used to identify areas in each district of the country which are prone to high risk from more than one hazard. The information will be useful in establishing the need of developing housing designs to resist the combination of such hazards.
All standards, whether given herein above or cross-referred to in the main text of this Section, are subject to revision. The parties to agreement based on this Section are encouraged to investigate the possibility of applying the most recent editions of the standards.
Section 1 Loads, Forces and Effects
1Scope
1.1 This Section covers basic design loads to be assumed in the design of buildings. The imposed loads, wind loads, seismic loads, snow loads and other loads, which are specified herein, are minimum working loads which should be taken into consideration for purposes of design.
1.2 This Section does not take into consideration loads incidental to construction.
3.3Imposed Loads on Floors Due to Use and Occupancy
3.3.1 Imposed Loads
The imposed loads to be assumed in the design of buildings shall be the greatest loads that probably will be produced by the intended use or occupancy, but shall not be less than the equivalent minimum loads specified in Table 1 subject to any reductions permitted in 3.3.2.
Floors shall be investigated for both the uniformly distributed load (UDL) and the corresponding concentrated load specified in Table 1, and designed for the most adverse effects but they shall not be considered to act simultaneously. The concentrated loads specified in Table 1 may be assumed to act over an area of 0.3 m × 0.3 m. However, the concentrated loads need not be considered where the floors are capable of effective lateral distribution of this load.
All other structural elements shall be investigated for
the effects of uniformly distributed loads on the floors specified in Table 1.
1 Where, in Table 1, no values are given for concentrated load, it may be assumed that the tabulated distributed load is adequate for design purposes.
2 The loads specified in Table 1 are equivalent uniformly distributed loads on the plan area and provide for normal effects of impact and acceleration. They do not take into consideration special concentrated loads and other loads.
3 Where the use of an area or floor is not provided in Table 1, the imposed load due to the use and occupancy of such an area shall be determined from the analysis of loads resulting from:
a) weight of the probable assembly of persons;
b) weight of the probable accumulation of equipment and furnishing;
c) weight of the probable storage materials; and
d) impact factor, if any.
4 While selecting a particular loading, the possible change in use or occupancy of the building should be kept in view. Designers should not necessarily select in every case the lower loading appropriate to the first occupancy. In doing this they might introduce considerable restrictions in the use of the building at a later date, and thereby reduce its utility.
5 The loads specified herein, which are based on estimations, may be considered as the characteristic loads for the purpose of limit state method of design till such time statistical data are established based on load surveys to be conducted in the country. 6 When an existing building is altered by an extension in height or area, all existing structural parts affected by the addition shall be strengthened where necessary and all new structural parts shall be designed to meet the requirements for building hereafter erected.
7 The loads specified in the section does not include loads incidental to construction. Therefore, close supervision during construction is essential to ensure that overloading of the building due to loads by way of stacking of building materials or use of equipment (for example, cranes and trucks) during construction or loads which may be induced by floor to floor propping in multi-storeyed construction, does not occur. However, if construction loads were of short duration, permissible increase in stresses in the case of working stress method or permissible decrease in load factors in limit state method, as applicable to relevant design codes, may be allowed for.
8 The loads in Table 1 are grouped together as applicable to buildings having separate principal occupancy or use. For a building with multiple occupancies, the loads appropriate to the occupancy with comparable use shall be chosen from other occupancies.
9 Regarding loading on lift machine rooms including storage space used for repairing lift machines, designers should go by the recommendations of lift manufacturers for the present. Regarding loading due to false ceiling, the same should be considered as imposed loads on the roof/floor to which it is fixed.
Table 1Imposed Floor Loads for Different Occupancies (Clause 3.3.1)
Sl No.(1)
Occupancy Classification(2)
Uniformly Distributed Load (UDL)(3)
Concentrated Load(4)
i) Residential Buildingsa) Dwelling houses:
KN/m²
KN
Table 1Continued
(1)
(2)
(3)
(4)
3) Corridors, passages, staircases including fire escapes and store rooms
3.0
4.5
4) Balconies
3.0
1.5 per metre run concentrated at the outer edge
b) Dwelling units planned and executed in accordance with [6-1(2)] only:
1) Habitable rooms, kitchens, and toilets and bathrooms
1.5
1.4
2) Corridors, passages and staircases including fire escapes
1.5
1.4
3) Balconies
3.0
1.5 per metre run concentrated at the outer edge
c) Hotels, hostels, boarding houses, lodging houses, dormitories and residential clubs:
1) Living rooms, bed rooms and dormitories
2.0
1.8
2) Kitchen and laundries
3.0
4.5
3) Billiards room and public lounges
3.0
2.7
4) Store rooms
5.0
4.5
5) Dining rooms, cafeterias and restaurants
4.0
2.7
6) Office rooms
2.5
2.7
7) Rooms for indoor games
3.0
1.8
8) Baths and toilets
2.0
—
9) Corridors, passages staircases including fire escapes and lobbies as per the floor services (excluding stores and the like) but not less than
3.0
4.5
10) Balconies
Same as rooms to which they give access but with a minimum of 4.0
1.5 per metre run concentrated at the outer edge
d) Boiler rooms and plant roomsto be calculated but not less than
5.0
6.7
e) Garages:
1) Garage floors (including parking area and repair workshops for passenger cars and vehicles not exceeding 2.5 tonnes gross weight, including access ways and ramps — to be calculated but not less than
2.5
9.0
2) Garage floors for vehicles not exceeding 4.0 tonnes gross weight (including access ways and ramps) — to be calculated but not less than
5.0
9.0
Table 1Continued
(1)
(2)
(3)
(4)
iii)
Institutional Buildings
a) Bed rooms, wards, dressing rooms, dormitories and lounges
2.0
1.8
b) Kitchens, laundries and laboratories
3.0
4.5
c) Dining rooms, cafeterias and restaurants
3.0¹⁾
2.7
d) Toilets and bathrooms
2.0
—
e) X-ray rooms, operating rooms and general storage areas — to be calculated but not less than
3.0
4.5
f) Office rooms and O.P.D. rooms
2.5
2.7
g) Corridors, passages, lobbies, staircases including fire escapes — as per the floor serviced (without accounting for storage and projection rooms) but not less than
4.0
4.5
h) Boiler rooms and plant rooms — to be calculated but not less than
5.0
4.5
j) Balconies
Same as rooms to which they give access but with a minimum of 4.0
1.5 metre run concentrated at the outer edge
iv)
Assembly Building
a) Assembly areas:
1) With fixed seats 2)
4.0
—
2) Without fixed seats
5.0
3.6
b) Restaurants (subject to assembly), museums and art galleries and gymnasia
4.0
4.5
c) Projection rooms
5.0
—
d) Stages
5.0
4.5
e) Office rooms, kitchens and laundries
3.0
4.5
f) Dressing rooms
2.0
1.8
g) Lounges and billiards rooms
2.0
2.7
h) Toilets and bathrooms
2.0
—
j) Corridors, passages and staircases including fire escapes
4.0
4.5
k) Balconies
Same as rooms to which they give access but with a minimum of 4.0
1.5 metre run concentrated at the outer edge
m) Boiler rooms and plant rooms including weight of machinery
Table 1Concluded
(1)
(2)
(3)
(4)
vi)
Merchantile Buildings
a) Retail shops
4.0
3.6
b) Wholesale shops — to be calculated but not less than
6.0
4.5
c) Office rooms
2.5
2.7
d) Dining rooms, restaurants and cafeterias
3.0¹⁾
2.7
e) Toilets
2.0
—
f) Kitchens and laundries
3.0
4.5
g) Boiler rooms and plant rooms — to be calculated but not less than
5.0
6.7
h) Corridors, passages, staircases including fire escapes and lobbies
4.0
4.5
j) Corridors, passages, staircases subject to loads greater than from crowds, such as wheeled vehicles, trolleys and the like
5.0
4.5
k) Balconies
Same as rooms to which they give access but with a minimum of 4.0
1.5 metre run concentrated at the outer edge
vii)
Industrial Buildings⁴⁾
a) Work areas without machinery/equipment
2.5
4.5
b) Work areas with machinery/ equipment³⁾
1) Light dutyTo be calculated but not less than
5.0
4.5
2) Medium duty
4.5
3) Heavy duty
7.010.0
4.54.5
c) Boiler rooms and plant rooms — to be calculated but not less than
5.0
6.7
d) Cafeterias and dinning rooms
3.0¹⁾
2.7
e) Corridors, passages, staircases including fire escapes
4.0
4.5
f) Corridors, passages, lobbies, staircases subject to machine loads and wheeled vehicles — to be calculated but not less than
5.0
4.5
g) Kitchens
3.0
4.5
h) Toilets and bathrooms
2.0
—
viii)
Storage Buildings⁴⁾
a) Storage rooms (other than cold storage) and warehouses — to be calculated based on the bulk density of materials stored but not less than
2.4 kN/m² per metre of storage height with a minimum of 7.5 kN/m²
3.3.1.1 Load application
The uniformly distributed loads specified in Table 1 shall be applied as static loads over the entire floor area under consideration or a portion of the floor area
whichever arrangement produces critical effects on the structural elements as provided in respective design codes.
In the design of floors, the concentrated loads are
considered to be applied in the positions which produce the maximum stresses and where deflection is the main criterion in the positions which produce the maximum deflections. Concentrated load, when used for the calculation of bending and shear, are assumed to act at a point. When used for the calculation of local effects, such as, crushing or punching, they are assumed to act over an actual area of application of 0.3 m × 0.3 m.
3.3.1.2 Loads due to light partitions
In office and other buildings, where actual loads due to light partitions cannot be assessed at the time of planning the floors and the supporting structural members shall be designed to carry, in addition to other loads, uniformly distributed loads per square metre of not less than 33.33 percent of weight per metre run of finished partitions, subject to a minimum of 1 kN/m2, provided total weight of partition walls per m2 of the wall area does not exceed 1.5 kN/m2 and the total weight per metre length is not greater than 4.0 kN.
3.3.2 Reduction in Imposed Loads on Floors
3.3.2.1 For members supporting floors
Except as provided for in 3.3.2.1 (a), the following reductions in assumed total imposed loads on the floors may be made in designing columns, load bearing walls, piers, their supports and foundations.
Number of Floors (Including the Roof) to be Carried by Member Under Consideration
Reduction in Total Distributed Imposed Load on All Floors to be Carried by the Member Under Consideration Percent
(1)
(2)
1
0
2
10
3
20
4
30
5 to 10
40
Over 10
50
a) No reduction shall be made for any plant or machinery which is specifically allowed for, or for buildings for storage purposes, warehouses and garages. However, for other buildings, where the floor is designed for an imposed floor load of 5.0 kN/m2 or more, the reductions shown in 3.3.2.1 may be taken provided that the loading assumed is not less than it would have been if all the floors had been designed for 5.0 kN/m2 with no reductions.
NOTE — In case if the reduced load in the lower floor is lesser than the reduced load in the upper floor, then the reduced load of the upper floor will be adopted.
b) An example is given in Annex A illustrating
the reduction of imposed loads in a multi-storeyed building in the design of column members.
3.3.2.2 For beams in each floor level
Where a single span of beam, girder or truss supports not less than 5 0 m 2 of floor at one general level, the imposed floor load may be reduced in the design of the beams, girders or trusses by 5 percent for each 50 m2 area supported subject to a maximum reduction of 25 percent. However, no reduction shall be made in any of the following types of loads:
a) any superimposed moving load,
b) any actual load due to machinery or similar concentrated loads,
c) the additional load in respect of partition walls; and
d) any impact or vibration.
NOTE — The above reduction does not apply to beams, girdes or trusses supporting roof loads.
3.3.3 Posting of Floor Capacities
Where a floor or part of a floor of a building has been designed to sustain a uniformly distributed load exceeding 3.0 k N / m 2 and in assembly, business mercantile, industrial or storage buildings, a permanent notice in the form shown below indicating the actual uniformly distributed and/or concentrated loadings for which the floor has been structurally designed shall be posted in a conspicuous place in a position adjacent to such floor or on such part of a floor.
DESIGNED IMPOSED FLOOR LOADING
Distributed......kN/m2
Concentrated......kN
Label Indicating Designed Imposed Floor Loading
1 The lettering of such notice shall be embossed or cast suitably on a tablet whose least dimension shall not be less than 0.25 m and located not less than 1.5 m above floor level with lettering of a minimum size of 25 mm.
2 If a concentrated load or a bulk load has to occupy a definite position on the floor, the same could also be indicated in the lable.
4Wind Load
4.1 General
This clause gives wind forces and their effects (static and dynamic) that should be taken into account when designing buildings, structures and components thereof.
1 It is believed that ultimately wind load estimation will be made by taking into account the random variation of wind speed with time, but available theoretical methods have not matured sufficiently at present for use in the Section. For this reason, equivalent static load estimation which implies a steady wind speed, which has proved to be satisfactory for normal, short and heavy structures, is given in 4.5 and 4.6. However, a beginning has been made to take account of the random nature of the wind speed by requiring that the alongwind or drag load on structures which are prone to wind induced oscillations, be also determined by the gust factor method (see 4.8) and the more severe of the two estimates be taken for design.
A large majority of structures met within practice do not, however, suffer wind induced oscillations and generally do not require to be examined for the dynamic effects of wind including use of gust factor method. Nevertheless, there are various types of structures or their components, such as some tall buildings, etc, which require investigation of wind induced oscillations. In identifying and analyzing such structures 4.6 shall be followed.
2 In the case of tall structures with unsymmetrical geometry, the designs may have to be checked for torsional effects due to wind pressure.
4.1.1 Wind is air in motion relative to the surface of the earth. The primary cause of wind is traced to earth’s rotation and differences in terrestrial radiation. The radiation effects are primarily responsible for convection either upwards or downwards. The wind
generally blows horizontal to the ground at high wind speeds. Since vertical components of atmospheric motion are relatively small, the term ‘wind’ denotes almost exclusively the horizontal wind, vertical winds are always identified as such. The wind speeds are assessed with the aid of anemometers or anemographs which are installed at meteorological observatories at heights generally varying from 10 to 30 m above ground.
4.1.2 Very strong wind speeds (greater than 80 km/h) are generally associated with cyclonic storms, thunderstorms, dust storms or vigorous monsoons. A feature of the cyclonic storms over the Indian area is that they rapidly weaken after crossing the coasts and move as depressions/lows inland. The influence of a severe storm after striking the coast does not, in general, exceed about 60 km, though sometimes, it may extend even up to 120 km. Very short duration hurricanes of very high wind speeds called Kal Baisaki or Norwesters occur fairly frequently during summer months over North-Eastern India.
4.1.3 The wind speeds recorded at any locality are extremely variable and, in addition to steady wind at any time, there are effects of gusts which may last for a few seconds. These gusts cause increase in air pressure but their effect on the stability of the building may not be so important; often, gusts affect only part of the building and the increased local pressures may be more than balanced by a momentary reduction in the pressure elsewhere. Because of the inertia of the building, short period gusts may not cause any appreciable increase in stress in the main components of the building, although the walls, roof sheeting and individual cladding units (glass panels) and their supporting members, such as purlins, sheeting rails and glazing bars may be more seriously affected. Gusts can also be extremely important for the design of structures with high slenderness ratios.
4.1.4 The liability of a building to high wind pressures depends not only upon the geographical location and proximity of other obstructions to air flow but also upon the characteristics of the structure itself.
4.1.5 The effect of wind on the structure as a whole is determined by the combined action of external and internal pressures acting upon it. In all cases, the calculated wind loads act normal to the surface to which they apply.
4.1.6 Buildings shall also be designed with due attention to the effects of wind on the comfort of people inside and outside the buildings.
4.1.7 The stability calculations of the building as a whole shall be done considering the combined effect, as well as separate effects of imposed loads and wind
loads on vertical surfaces, roofs and other parts of the building above the general roof level.
4.2 Notations
The notations to be followed, unless otherwise specified in relevant clauses under wind loads, are given in Annex B.
3.6Loading Effects Due to Impact and Vibration
The crane loads to be considered under imposed loads shall include the vertical loads, eccentricity effects induced by vertical loads, impact factors, lateral and longitudinal braking forces acting across and along the crane rails respectively.
3.6.1 Impact Allowance for Lifts, Hoists and Machinery
The imposed loads specified in 3.3.1 shall be assumed to include adequate allowance for ordinary impact conditions. However, for structures carrying loads
Table 3Horizontal Loads on Parapets, Parapet Walls and Balustrades (Clause 3.5.1)
Sl No.
Usage Area
Intensity of Horizontal Load kN/m Run
(1)
(2)
(3)
i)
Light access stairs, gangways and like not more than 600 mm wide
0.25
ii)
Light access stairs, gangways and like, more than 600 mm wide; stairways, landings, balconies and parapet walls (private and part of dwellings)
0.35
iii)
All other stairways, landings and balconies and all parapets and handrails to roofs [except those subject to overcrowding covered under (iv)]
0.75
iv)
Parapets and balustrades in place of assembly, such as theatres, cinemas, churches, schools, places of entertainment, sports and buildings and buildings likely to be overcrowded
2.25
NOTE — In the case of guard parapets on a floor of multi-storeyed car park or crash barriers provided in certain buildings for fire escape, the value of imposed horizontal load (together with impact load) may be determined.
which induce impact or vibration, as far as possible, calculations shall be made for increase in the imposed load due to impact or vibration. In the absence of sufficient data for such calculation, the increase in the imposed loads shall be as follows:
Structures
Impact Allowance, Percent, Min
a) For frames supporting lifts and hoists
100
b) For foundations, footings and piers supporting lifts and hoisting apparatus
40
c) For supporting structures and foundations for light machinery, shaft or motor units
20
d) For supporting structures and foundations for reciprocating machinery or power units
50
3.6.2 Concentrated Imposed Loads with Impact and Vibration
Concentrated imposed loads with impact and vibration which may be due to installed machinery shall be considered and provided for in the design. The impact factor shall not be less than 20 percent which is the amount allowable for light machinery.
3.6.2.1 Provision shall also be made for carrying any
concentrated equipment loads while the equipment is being installed or moved for servicing and repairing.
3.6.3 Impact Allowance for Crane Girders
For crane gantry girders and supporting columns, the impact allowances (given in informal table below) shall be deemed to cover all forces set up by vibration, shock from slipping of slings, kinetic action of acceleration, and retardation and impact of wheel loads.
Forces specified in (c) and (d) shall be considered as acting at the rail level and being appropriately transmitted to the supporting system. Gantry girders and their vertical supports shall be designed on the assumption that either of the horizontal forces in (c) and (d) may act at the same time as the vertical load.
NOTE — See [6-1(3)] for classification (Class I to IV) of cranes.
Impact Allowance for Crane Girders
Type of Load
Additional Load
a)
Vertical loads for electric overhead cranes
25 percent of maximum static loads for crane girders for all class of cranes
25 percent for columns supporting Class III and Class IV cranes.
10 percent for columns supporting Class I and Class II cranes.
No additional load for design of foundations.
b)
Vertical loads for hand operated cranes
10 percent of maximum wheel loads for crane girders only
c)
Horizontal forces transverse to rails:
1) For electric overhead cranes with trolley having rigid mast for suspension of lifted weight (such as, soaker crane, stripper crane, etc)
10 percent of weight of crab and the weight lifted by the cranes, acting on any one crane track rail, acting in either direction and equally distributed amongst all the wheels on one side of rail track
For frame analysis, this force, calculated as above, shall be applied on one side of the frame at a time in either direction.
2) For all other electric overhead cranes and hand operated cranes
5 percent of weight of crab and the weight lifted by the cranes, acting on any one crane track rail, acting in either direction and equally distributed amongst the wheels on one side of rail track
For the frame analysis, the force, calculated as above, shall be applied on one side of the frame at a time in either direction.
d)
Horizontal traction forces along the rails for overhead cranes, either electrically operated or hand operated
5 percent of all static wheel loads
3.6.3.1 Overloading factors in crane supporting structures
3.6.4 Crane Load Combinations
In the absence of any specific indications, the load combinations shall be as indicated below.
3.6.4.1 Vertical loads
In an aisle, where more than one crane is in operation or has provision for more than one crane in future, the following load combinations shall be taken for vertical loading:
a) Two adjacent cranes working in tandem with full load and with overloading according to 3.6.3.1; and
b) For long span gantries, where more than one crane can come in the span, the girder shall be designed for one crane fully loaded with overloading according to 3.6.3.1 plus as many loaded cranes as can be accommodated on the span but without taking into account overloading according to 3.6.3 (a) to give the maximum effect.
3.6.4.2 Lateral surge
For design of columns and foundations, supporting crane girders, the following crane combinations shall be considered:
a) For Single Bay Frames — Effect of one crane in the bay giving the worst effect shall be considered for calculation of surge force; and
b) For Multi-Bay Frames — Effect of two cranes working, one each in any of two bays in the cross-section to give the worst effect shall be considered for calculation of surge force.
3.6.4.3 Tractive force
a) Where one crane is in operation with no provision for future crane, tractive force from only one crane shall be taken.
b) Where more than one crane is in operation or there is provision for future crane, tractive force from two cranes giving maximum effect shall be considered.
NOTE — Lateral surge force and longitudinal tractive force acting across and along the crane rail respectively shall not be assumed to act simultaneously. However, if there is only one crane in the bay, the lateral and longitudinal forces may act together simultaneously with vertical loads.
3.4Imposed Loads on Roofs
3.4.1 Imposed Loads on Various Types of Roofs
On flat roofs, sloping roofs and curved roofs, the imposed loads due to use and occupancy of the buildings and the geometry of the types of roofs shall be as given in Table 2.
Table 2Imposed Loads on Various Types of Roofs (Clause 3.4.1)
Sl No.(1)
Type of Roof(2)
Imposed Load Measured on Plan Area(3)
Minimum Imposed Load Measured on Plan(4)
i)
Flat, sloping or curved roof with slopes up to and including 10 degrees
a) Access provided
1.5 kN/m²
3.75 kN uniformly distributed over any span of one metre width of the roof slab and 9 kN uniformly distributed over the span of any beam or truss or wall
b) Access not provided except for maintenance
0.75 kN/m²
1.9 kN uniformly distributed over any span of one metre width of the roof slab and 4.5 kN uniformly distributed over the span of any beam or truss or wall
ii)
Sloping roof with slope greater than 10°
For roof membrane sheets or purlins - 0.75 kN/m2less 0.02 kN/m2for every degree increase in slope over 10°
Subject to a minimum of 0.4 kN/m²
iii)
Curved roof with slope of line obtained by joining springing point to the crown with the horizontal, greater than 10°
(0.75 - 0.52 α²) kN/m² where α = h/l h = height of the highest point of the structure measured from its springing; and l = chord width of the roof if singly curved and shorter of the two sides if doubly curved.Alternatively, where structural analysis can be carried out for curved roofs of all slopes in a simple manner applying the laws of statistics, the curved roofs shall be divided into minimum 6 equal segments and for each segment imposed load shall be calculated appropriate to the slope of the chord of each segment as given in (i) and (ii).
Subject to a minimum of 0.4 kN/m²
NOTES
1 The loads given above do not include loads due to snow, rain, dust collection, etc. The roof shall be designed for imposed loads given above or for snow/rain load, whichever is greater.
2 For special types of roofs with highly permeable and absorbent material, the contingency of roof material increasing in weight due to absorption of moisture shall be provided for.
3.4.1.1 Roofs of buildings used for promenade or incidental to assembly purposes shall be designed for the appropriate imposed floor loads given in Table 1 for the occupancy.
3.4.2 Concentrated Load on Roof Coverings
To provide for loads incidental to maintenance, unless otherwise specified by the Engineer-in-Charge, all roof coverings (other than glass or transparent sheets made of fibre glass) shall be capable of carrying an incidental load of 0.90 kN concentrated on an area of 12.5 cm2 so placed as to produce maximum stresses in the covering. The intensity of the concentrated load may be reduced with the approval of the Engineer-in-Charge, where it is ensured that the roof coverings would not be traversed without suitable aids. In any case, the roof coverings shall be capable of carrying the loads in accordance with 3.4.1, 3.4.3, 3.4.4 and wind load.
3.4.3 Loads Due to Rain
On surfaces whose positioning, shape and drainage system are, such as, to make accumulation of rain water possible, loads due to such accumulation of water and the imposed loads for the roof as given in Table 2 shall be considered separately and the more critical of the two shall be adopted in the design.
3.4.4 Dust Loads
In areas prone to settlement of dust on roofs (example, steel plants, cement plants), provision for dust load equivalent to probable thickness of accumulation of dust may be made.
3.4.5 Loads on Members Supporting Roof Coverings
Every member of the supporting structure which is directly supporting the roof covering(s) shall be
designed to carry the more severe of the following loads except as provided in 3.4.5.1:
a) The load transmitted to the members from the roof covering(s) in accordance with 3.4.1, 3.4.3 and 3.4.4; and
b) An incidental concentrated load of 0.90 kN concentrated over a length of 12.5 cm placed at the most favourable positions on the member.
NOTE — Where it is ensured that the roofs would be traversed only with the aid of planks and ladders capable of distributing the loads on them to two or more supporting members, the intensity of concentrated load indicated in 3.4.5 (b) may be reduced to 0.5 kN with the approval of the Engineer-in-Charge.
3.4.5.1 In case of sloping roofs with slope greater than 10o, members supporting the roof purlins, such as trusses, beams, girders, etc, may be designed for twothirds of the imposed load on purlin or roofing sheets.
2Dead Load
2.1 Assessment of Dead Load
The dead load in a building shall comprise the weight of all walls, partitions, floors and roofs, and shall include the weights of all other permanent constructions in the building and shall conform to good practice [6-1(1)].
4.3Terminology
4.3.1 For the purpose of wind loads, the following definitions shall apply.
4.3.1.1 Angle of attack — Angle between the direction of wind and a reference axis of the structure.
4.3.1.2 Breadth — Breadth means horizontal dimension of the building measured normal to the direction of wind.
4.3.1.3 Depth — Depth means the horizontal dimension of the building measured in the direction of the wind.
NOTE — Breadth and depth are dimensions measured in relation to the direction of the wind, whereas length and width are dimensions related to the plan.
4.3.1.4 Developed height
Developed height is the height of upward penetration of the velocity profile in a new terrain. At large, fetch lengths, such penetration reaches the gradient height above which the wind speed may be taken to be constant. At lesser-fetch lengths, a velocity profile of a smaller height but similar to that of the fully developed profile of that terrain category has to be taken, with the additional provision that the velocity at the top of this shorter profile equals that of the unpenetrated earlier velocity profile at that height.
4.3.1.5 Effective frontal area
The projected area of the structure normal to the direction of the wind.
4.3.1.6 Element surface area
The area of surface over which the pressure coefficient is taken to be constant.
4.3.1.7 Force coefficient
A non-dimensional coefficient such that the total wind force on a body is the product of the force coefficient, the dynamic pressure of the incident design wind speed and the reference area over which the force is required.
NOTE — When the force is in the direction of the incident wind, the non-dimensional coefficient will be called as drag coefficient. When the force is perpendicular to the direction of incident wind the non-dimensional coefficient will be called as ‘lift coefficient’.
4.3.1.8 Ground roughness
The nature of the earth’s surface as influenced by small scale obstructions such as trees and buildings (as distinct from topography) is called ground roughness.
4.3.1.9 Gust
A positive or negative departure of wind speed from its mean value, lasting for not more than say 2 min over a specified interval of time.
4.3.1.10 Peak gust
Peak gust or peak gust speed is the wind speed associated with the maximum amplitude.
4.3.1.11 Fetch length
Fetch length is the distance measured along the wind from a boundary at which a change in the type of terrain occurs. When the changes in terrain types are encountered (such as the boundary of a town or city, forest, etc), the wind profile changes in character but such changes are gradual and start at ground level, spreading or penetrating upwards with increasing fetch length.
4.3.1.12 Gradient height
Gradient height is the height above the mean ground level at which the gradient wind blows as a result of balance among pressure gradient force, coriolis force and centrifugal force. For the purpose of this Section, the gradient height is taken as the height above the mean ground level above which the variation of wind speed with height need not be considered.
4.3.1.13 Mean ground level
The mean ground level is the average horizontal plane of the area enclosed by the boundaries of the structure.
4.3.1.14 Pressure coefficient
Pressure coefficient is the ratio of the difference between the pressure acting at a point on a surface and the static pressure of the incident wind to the design wind pressure, where the static and design wind pressure are determined at the height of the point considered after taking into account the geographical location, terrain conditions and shielding effect. The pressure coefficient is also equal to [ 1 - ( V p / V z ) 2 ] , where V p is the actual wind speed at any point on the structure at a height corresponding to that of V z .
NOTE — Positive sign of the pressure coefficient indicates pressure acting towards the surface and negative sign indicates pressure acting away from the surface.
4.3.1.15 Return period
Return period is the number of years, the reciprocal of which gives the probability of extreme wind exceeding a given wind speed in any one year.
4.3.1.16 Shielding effect
Shielding effect or shielding refers to the condition where wind has to pass along some structure(s) or structural element(s) located on the upstream wind side, before meeting the structure or structural element under consideration. A factor called ‘shielding factor’ is used to account for such effects in estimating the force on the shielded structures.
4.3.1.17 Suction
Suctions means pressure less than the atmospheric (static) pressure and is taken to act away from the surface.
4.3.1.18 Solidity ratio
Solidity ratio is equal to the effective area (projected area of all the individual elements) of a frame normal to the wind direction divided by the area enclosed by the boundary of the frame normal to the wind direction.
NOTE — Solidity ratio is to be calculated for individual frames.
4.3.1.19 Terrain category
Terrain category means the characteristics of the surface irregularities of an area which arise from natural or constructed features. The categories are numbered in increasing order of roughness.
4.3.1.20 Velocity profile
The variation of the horizontal component of the atmospheric wind speed at different heights above the mean ground level is termed as velocity profile.
4.3.1.21 Topography
The nature of the earth’s surface as influenced by the hill and valley configurations.
3.5Imposed Horizontal Loads on Parapets and Balustrades
3.5.1 Parapets, Parapet Walls and Balustrades
Parapets, parapet walls and balustrades, together with the members which give them structural support, shall be designed for the minimum loads given in Table 3. These are expressed as horizontal forces acting at handrail or coping level. These loads shall be considered to act vertically also but not simultaneously with the horizontal forces. The values given in Table 3 are minimum values and where values for actual loadings are available, they shall be used instead.
3.5.2 Grandstands and the Like
Grandstands, stadia, assembly platforms, reviewing stands and the like shall be designed to resist a horizontal force applied to seats of 0.35 kN per linear metre along the line of seats and 0.15 kN per linear metre perpendicular to the line of the seats. These loadings need not be applied simultaneously. Platforms without seats shall be designed to resist a minimum horizontal force of 0.25 kN/m2 of plan area.
4.4Wind Speed and Pressure
4.4.1 Nature of Wind in Atmosphere
In general, wind speed in the atmospheric boundary layer increases with height from zero at ground level to a maximum at a height called the gradient height. There is usually a slight change in direction (Ekman effect) but this is ignored in the Section. The variation with height depends primarily on the terrain conditions. However, the wind speed at any height never remains constant and it has been found convenient to resolve its instantaneous magnitude into an average or mean value and a fluctuating component around this average value. The average value depends on the averaging time employed in analyzing the meteorological data and this averaging time varies from a few seconds to several minutes. The magnitude of the fluctuating component of the wind speed, which is called as gust, depends on the averaging time. In general, smaller the
averaging interval, greater is the magnitude of the gust speed.
4.4.2 Basic Wind Speed
Figure 1 gives basic wind speed map of India, as applicable to 10 m height above mean ground level for 10 m height above mean ground level for different zones of the country. Basic wind speed is based on peak gust velocity averaged over a short time interval of about 3 s and corresponds to mean heights above ground level in an open terrain (Category 2). Basic wind speeds presented in Fig. 1 have been worked out for a 50 year return period. Basic wind speed for some important cities/towns is also given in Annex C.
4.4.3 Design Wind Speed (V )
The basic wind speed ( V b ) for any site shall be obtained from Fig. 1 and shall be modified to include the following effects to g e t V z , design wind speed at any height for the chosen structure.
a) risk level;
b) terrain roughness, height and size of structure; and
c) local topography.
It can be mathematically expressed as follows:
V z = V b k ₁ k ₂ k ₃
where
V = design of wind speed at any height z in m/s;
V = basic wind speed in m/s (Fig. 1);
k = probability factor (risk coefficient) (4.4.3.1);
k = terrain, height and structure size factor (4.4.3.2); and
k = topography factor (4.4.3.3)
NOTE — Design wind speed up to 10 m height from mean ground level shall be considered constant.
4.4.3.1 Risk coefficient (k1)
Figure 1 gives basic wind speeds for terrain Category 2 as applicable at 10 m above ground level based on 50 year mean return period. The suggested life period to be assumed in design and the corresponding k 1 factors for different classes of structure for the purpose of design is given in Table 4. In the design of all buildings and structures, a regional basic wind speed having a mean return period of 50 years shall be used except as specified in the note of Table 4.
4.4.3.2 Terrain, height and structure size factor (k2)
a) Terrain — Selection of terrain categories shall be made with due regard to the effect of the obstruction which constitute the ground surface roughness. The terrain category used in the
The territorial waters of India extend into the sea to a distance of twelve nautical miles measured from the appropriate base line. The boundary of Meghalaya shown on this map is as interpreted from the North-Eastern Areas (Reorganisation) Act, 1971, but has yet to be verified. Responsibility for correctness of internal details shown on the map rests with the publisher. The state boundaries between Uttaranchal & Uttar Pradesh, Bihar & Jharkhand and Chhatisgarh & Madhya Pradesh have not been verified by Governments concerned.
Based upon Survey of India Outline Map printed in 1993.
FIG. 1 BASIC WIND SPEED IN m/s (BASED ON 50-YEARS RETURN PERIOD)
Table 4Risk Coefficients for Different Classes of Structures in Different Wind Speed Zones (Clause 4.4.3.1)
Class of Structure
Mean Probable Design Life of Structure in Years
k₁ Factor for Basic Wind Speed (m/s) of
33(3)
39(4)
44(5)
47(6)
50(7)
55(8)
4.4.3.3 Topography (k3, factor)
The basic wind speed V b given in Fig. 1 takes account of the general level of the site above sea level. This does not allow for local topographic features, such as hills, valleys, cliffs, escarpments or ridges, which can significantly affect wind speed in their vicinity. The effect of topography is to accelerate wind near the summits of hills or crests of cliffs, escarpments or ridges and decelerate the wind in valleys or near the foot of cliffs, steep escarpments or ridges.
The effect of topography will be significant at a site when the upwind slope is greater than about 3 ° , and below that the value of k 3 may be taken to be equal to 1.0. The value of k 3 is confined in the range of 1.0 to 1.36 for slopes greater than 3°. A method of evaluating the value of k 3 for slope greater than 3 ° is given in Annex E. It may be noted that the value of k 3 varies with height above ground level with a maximum near the ground, and reducing to 1.0 at higher levels.
4.4.4 Design Wind Pressure
The design wind pressure at any height above mean ground level shall be obtained by the following relationship between wind pressure and wind velocity:
p z = 0. 6 V z ²
where
p = design wind pressure in N / m 2 at height Z, and
V z = design wind velocity in m / s at height Z.
NOTE — The coefficient 0.6 (in SI units) in the above formula depends on a number of factors, and mainly on the atmospheric pressure and air temperature. The value chosen corresponds to the average appropriate Indian atmospheric conditions.
4.4.5 Offshore Wind Velocity
Cyclonic storms form far way from the sea coast and gradually reduce in speed as they approach the sea coast. Cyclonic storms generally extend up to about 60 km inland after striking the coast. Their effect on land is already reflected in basic wind speeds specified in Fig. 1. The influence of wind speed off the coast up to a distance of about 200 km may be taken as 1.15 times the value on the nearest coast in the absence of any definite wind data.
4.6Dynamic Effects
4.6.1 General
Flexible slender structures and structural elements shall be investigated to ascertain the importance of wind induced oscillations for excitations along and across the direction of wind.
In general the following guidelines may be used for examining the problems of wind induced oscillations:
a) Buildings and closed structures with a height to minimum lateral dimension ratio of more than about 5.0; or
b) Buildings and structures whose natural frequency in the first mode is less than 1.0 Hz. Any building or structure which satisfies either of the above two criteria shall be examined for dynamic effects of wind.
1 The fundamental natural period (T ), in seconds, of a moment-resisting frame building without brick infil panels and of all other buildings including with brick infil panels may be estimated in accordance with 5.4.6. 2 If preliminary studies indicate that wind-induced oscillations are likely to be significant, investigations should be persued with the aid of analytical methods or, if necessary, by means of wind tunnel tests on models.
3 Cross wind motions may be due to the lateral gustiness of the wind, unsteady wake flow (for example, vortex shedding), negative aerodynamic damping or to a combination of these effects. These cross-wind motions can become critical in the design of tall building structures.
4 Motions in the direction of the wind (also known as buffeting) are caused by fluctuating wind force associated with gusts. The excitations depend on the gust energy available at the resonant frequency.
a) Values of C versus a / b for h 1 6 ≥ 1
b) Values of C versus a / b for h / b < 1
FIG. 4 FORCE COEFFICIENT FOR RECTANGULAR CLAD BUILDING IN UNIFORM FLOW
Table 26Force Coefficients C for Clad Buildings of Uniform Section (Acting in the Direction of Wind) [Clause 4.5.3.2 (a)]
Plan Shape
V₂b m²/s
Cf for Height/Breadth Ratio
Up to 1/2
1
2
5
10
20
∞
(see also Annex E)
All surfaces
<6
0.7
0.7
0.7
0.8
0.9
1.0
1.2
Rough or with projections
≥6
Smooth
≥6
0.5
0.5
0.5
0.5
0.5
0.6
0.6
Ellipse b/d = 1/2
<10
0.5
0.5
0.5
0.5
0.6
0.6
0.7
≥10
0.2
0.2
0.2
0.2
0.2
0.2
0.2
Ellipse b/d = 2
<8
0.8
0.8
0.9
1.0
1.1
1.3
1.7
≥8
0.8
0.8
0.9
1.0
1.1
1.3
1.5
b/d = 1r/b = 1/3
<4
0.6
0.6
0.6
0.7
0.8
0.8
1.0
≥4
0.4
0.4
0.4
0.4
0.5
0.5
0.5
b/d = 1r/b = 1/6
<10
0.7
0.8
0.8
0.9
1.0
1.0
1.3
≥10
0.5
0.5
0.5
0.5
0.6
0.6
0.6
b/d = 1/2r/b = 1/2
<3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
≥3
0.2
0.2
0.2
0.2
0.3
0.3
0.3
All values
0.5
0.5
0.5
0.5
0.6
0.6
0.7
b/d = 2r/b = 1/12
All values
0.9
0.9
1.0
1.1
1.2
1.5
1.9
Table 26Continued
Plan Shape
V₂b m²/s
Cf for Height/Breadth Ratio
Up to 1/2
1
2
5
10
20
∞
<6
0.7
0.8
0.8
0.9
1.0
1.2
1.6
≥6
0.5
0.5
0.5
0.5
0.5
0.6
0.6
<10
0.8
0.8
0.9
1.0
1.1
1.3
1.5
≥10
0.5
0.5
0.5
0.5
0.5
0.6
0.6
All values
0.9
0.9
0.9
1.1
1.2
1.3
1.6
r/a = 1/48
All values
0.9
0.9
0.9
1.1
1.2
1.3
1.6
r/b = 1/4
<11
0.7
0.7
0.7
0.8
0.9
1.0
1.2
≥11
0.4
0.4
0.4
0.4
0.5
0.5
0.5
r/b = 1/12
All values
0.8
0.8
0.8
1.0
1.1
1.2
1.4
All values
0.7
0.7
0.8
0.9
1.0
1.1
1.3
Table 26Concluded
Plan Shape
Vzb m²/s
Cf for Height/Breadth Ratio
Up to 1/2
1
2
5
10
20
∞
< 8
0.7
0.7
0.8
0.9
1.0
1.1
1.3
≥ 8
0.4
0.4
0.4
0.4
0.5
0.5
0.5
All values
1.2
1.2
1.2
1.4
1.6
1.7
2.1
12 sided polygon
< 12
0.7
0.7
0.8
0.9
1.0
1.1
1.3
≥ 12
0.7
0.7
0.7
0.7
0.8
0.9
1.1
Octagon
All values
1.0
1.0
1.1
1.2
1.2
1.3
1.4
Hexagon
All values
1.0
1.1
1.2
1.3
1.4
1.4
1.5
NOTE — Structures that, because of their size and the design wind velocity, are in the supercritical flow regime may need further calculation to ensure that the greatest loads do not occur at some wind speed below the maximum when the flow will be subcritical.
The coefficients are for buildings without projections, except where otherwise shown. In this table V b is used as an indication of the airflow regime.
Table 27 Force Coefficients for Low Walls or Hoardings (<15 m High) [Clause 4.5.3.2 (b)]
(Wind normal to face)
Width to Height Ratio, b/h
Drag Coefficient, Cf
Wall above ground
Wall on ground
From 0.5 to 6
From 1 to 12
1.2
10
20
1.3
16
32
1.4
20
40
1.5
40
80
1.7
60
120
1.8
80 or more
160 more 20
2.0
SIDE ELEVATION
DESCRIPTION OF SHAPE
C<sub>f</sub>
CIRCULAR DISC
1.2
HEMISPHERICAL BOWL
1.4
HEMISPHERICAL BOWL
0.4
HEMISPHERICAL SOLID
-1.2
SPHERICAL SOLID
0.5 FOR V D < 70.2 FOR V D ≥ 7
FIG. 6 FORCE COEFFICIENTS FOR SOLID SHAPES MOUNTED ON A SURFACE
5 The wake shed from an upstream body may intensify motions in the direction of the wind, and may also effect crosswind motions.
6 The designer must be aware of the following three forms of wind induced motion which are characterized by increasing amplitude of oscillation with increase of wind speed.
a) Galloping — Galloping is transverse oscillations of some structures due to the development of aerodynamic forces which are in phase with the motion. It is characterized by the progressively increasing amplitude of transverse vibration with increase of wind speed. The cross-sections which are particularly prone to this type of excitation include the following:
i) All structures with non-circular cross-sections, such as triangular, square, polygons, as well as angles, crosses and T-sections.
ii) Twisted cables and cables with ice encrustations.
b) Flutter — Flutter is unstable oscillatory motion of a structure due to coupling between aerodynamic force and the elastic deformation of the structure. Perhaps the most common form is the oscillatory motion due to combined bending and torsion. Although oscillatory motions in each degree of freedom may be dampled, instability can set in due to energy transfer from one mode of oscillation to another, and the structure is seen to execute sustained or divergent oscillations with a type of motion which is a combination of the individual modes of motion. Such energy transfer takes place when the natural frequencies of the modes, taken individually, are close to each other (ratio being typically less than 2.0). Flutter can set in at wind speeds much less than those required for exciting the individual modes of motion. Long span suspension bridge decks or any member of a structure with large values of d/t (where d is the depth of a structure or structural member parallel to wind stream and t is the least lateral dimension
of a member) are prone to low speed flutter. Wind tunnel testing is required to determine critical flutter speeds and the likely structural response. Other types of flutter are single degree of freedom stall flutter, torsional flutter etc.
c) Ovalling — Thin walled structures with open ends at one or both ends, such as oil storage tanks, and natural draught cooling towers, in which the ratio of the diameter of minimum lateral dimension to the wall thickness is of the order of 100 or more, are prone to ovalling oscillations. These oscillations are characterized by periodic radial deformation of the hollow structure.
7 Buildings and structures that may be subjected to serious wind excited oscillations require careful investigation. It is to be noted that wind induced oscillations may occur at wind speeds lower than the static design wind speed for the location.
8 Analytical methods for determining dynamic response of structures to wind loading can be found in the following publications:
b) ‘Wind Engineering in the Eighties’. Construction Industry Research and Information Association, 1981, London.
c) ‘Wind Effects on Structures’ by E Simiu and R.H. Scanlan. Johan Wiley and Sons, New York, 1978.
d) Supplement to the National Building Code of Canada, 1980. NRCC, No. 17724. National Research Council of Canada, Ottawa, 1980.
e) Wind Forces on Structures by Peter Sachs. Pergamon Press.
f) Flow Induced Vibration by Robert D. Clevins. Von Nostrand Reinfold Co.
9 In assessing wind loads due to such dynamic phenomenon as galloping, flutter and ovalling, if the required information is not available either in the references of Note 8 or other literature, specialist advice shall be sought, including experiments on models in wind tunnels.
4.6.2 Motions Due to Vortex Shedding
4.6.2.1 Slender structures — For a structure, the shedding frequency, η shall be determined by the following formula:
η=bSVd
where
S = Strouhal number,
V d = design wind velocity, and
b = The breadth of a structure or structural members in the horizontal plane normal to the wind direction.
a) Circular Structures — For structures circular in cross-section:
S = 0.20 for b V z not greater than 7, and S = 0.25 for b V z greater than 7.
b) Rectangular Structures — For structures of rectangular cross-section:
S = 0. 1 5 for all values of b V .
5Seismic Load
5.0 This clause deals with assessment of seismic loads on various structures and earthquake resistant design of buildings. (For the purpose of this clause the symbols given at Annex G are applicable).
5.1 Terminology for Earthquake Engineering
5.1.1 For the purpose of this standard, the following definitions shall apply which are applicable generally to all structures:
NOTE — For the definitions of terms pertaining to soil mechanics and soil dynamics references may be made to Part 6 ‘Structural Design, Section 2 Soils and Foundations’.
5.1.2 Closely-Spaced Modes
Closely-spaced modes of a structure are those of its natural modes of vibration whose natural frequencies differ from each other by 10 percent or less of the lower frequency.
5.1.3 Critical Damping
The damping beyond which the free vibration motion will not be oscillatory.
5.1.4 Damping
The effect of internal friction, imperfect elasticity of material, slipping, sliding etc, in reducing the amplitude of vibration and is expressed as a percentage of critical damping.
5.1.5 Design Acceleration Spectrum
Design acceleration spectrum refers to an average smoothened plot of maximum acceleration as a function of frequency or time period of vibration for a specified damping ratio for earthquake excitations at the base of a single degree of freedom system.
5.1.6 Design Basis Earthquake (DBE)
It is the earthquake which can reasonably be expected to occur at least once during the design life of the structure.
It is a horizontal acceleration coefficient that shall be used for design of structures.
5.1.8 Design Lateral Force
It is the horizontal seismic force prescribed by this standard, that shall be used to design a structure.
5.1.9 Ductility
Ductility of a structure, or its members, is the capacity to undergo large inelastic deformations without significant loss of strength or stiffness.
FIG. 8 BACKGROUND FACTOR, B
FIG. 9 GUST ENERGY FACTOR, E
FIG. 10 SIZE REDUCTION FACTOR, S
5.1.10 Epicentre
The geographical point on the surface of earth vertically above the focus of the earthquake.
5.1.11 Effective Peak Ground Acceleration (EPGA)
It is 0.4 times the 5 percent damped average spectral acceleration between period 0.1 to 0.3 s. This shall be taken as zero period acceleration (ZPA).
5.1.12 Floor Response Spectra
Floor response spectra is the response spectra for a time history motion of a floor. This floor motion time history is obtained by an analysis of multi-storey building for appropriate material damping values subjected to a specified earthquake motion at the base of structure.
5.1.13 Focus
The originating earthquake source of the elastic waves inside the earth which cause shaking of ground due to earthquake.
5.1.14 Importance Factor (I)
It is a factor used to obtain the design seismic force depending on the functional use of the structure, characterised by hazardous consequences of its failure, its post-earthquake functional need, historic value, or economic importance.
5.1.15 Intensity of Earthquake
The intensity of an earthquake at a place is a measure of the strength of shaking during the earthquake, and is indicated by a number according to the modified Mercalli Scale or M.S.K. scale of Seismic Intensities (see Annex H).
5.1.16 Liquefaction
Liquefaction is a state in saturated cohesionless soil wherein the effective shear strength is reduced to negligible value for all engineering purpose due to pore pressure caused by vibrations during an earthquake when they approach the total confining pressure. In this condition the soil tends to behave like a fluid mass.
5.1.17 Lithological Features
The nature of the geological formation of the earth‘s crust above bed rock on the basis of such characteristics as colour, structure, mineralogical composition and grain size.
5.1.18 Magnitude of Earthquake (Richter’s Magnitude)
The magnitude of earthquake is a number, which is a measure of energy released in an earthquake. It is defined as logarithm to the base 10 of the maximum trace amplitude, expressed in microns, which the
standard short-period torsion seismometer (with a period of 0.8 s, magnification 2 800 and damping nearly critical) would register due to the earthquake at an epicentral distance of 100 km.
5.1.19 Maximum Considered Earthquake (MCE)
The most severe earthquake effects considered by this Code.
5.1.20 Modal Mass (Mk)
Modal mass of a structure subjected to horizontal or vertical, as the case may be, ground motion is a part of the total seismic mass of the structure that is effective in mode k of vibration. The modal mass for a given mode has a unique value irrespective of scaling of the mode shape.
5.1.21 Modal Participation Factor (Pk)
Modal participation factor of mode k of vibration is the amount by which mode k contributes to the overall vibration of the structure under horizontal and vertical earthquake ground motions. Since the amplitudes of 95 per cent mode shapes can be scaled arbitrarily, the value of this factor depends on the scaling used for mode shapes.
5.1.22 Modes of Vibration (see 5.1.25)
5.1.23 Mode Shape Coefficient (ϕik)
When a system is vibrating in normal mode k , at any particular instant of time, the amplitude of mass i expressed as a ratio of the amplitude of one of the masses of the system, is known as mode shape coefficient ( φ i k )
5.1.24 Natural Period ( T)
Natural period of a structure is its time period of undamped free vibration.
5.1.24.1 Fundamental natural period (T1)
It is the first (longest) modal time period of vibration.
5.1.24.2 Modal natural period (Tk)
The modal natural period of mode k is the time period of vibration in mode k.
5.1.25 Normal Mode
A system is said to be vibrating in a normal mode when all its masses attain maximum values of displacements and rotations simultaneously, and pass through equilibrium positions simultaneously.
5.1.26 Response Reduction Factor (R)
It is the factor by which the actual base shear force, that would be generated if the structure were to remain elastic during its response to the design basis
earthquake (DBE) shaking, shall be reduced to obtain the design lateral force.
5.1.27 Response Spectrum
The representation of the maximum response of idealized single degree freedom systems having certain period and damping, during earthquake ground motion. The maximum response is plotted against the undamped natural period and for various damping values, and can be expressed in terms of maximum absolute acceleration, maximum relative velocity, or maximum relative displacement.
5.1.28 Seismic Mass
It is the seismic weight divided by acceleration due to gravity.
5.1.29 Seismic Weight (W)
It is the total dead load plus appropriate amounts of specified imposed load.
5.1.30 Structural Response Factors (Sa/g)
It is a factor denoting the acceleration response spectrum of the structure subjected to earthquake ground vibrations, and depends on natural period of vibration and damping of the structure.
5.1.31 Tectonic Features
The nature of geological formation of the bed rock in the earth’s crust revealing regions characterized by structural features, such as dislocation, distortion, faults, folding, thrusts, volcanoes with their age of formation, which are directly involved in the earth movement or quake resulting in the above consequences.
5.1.32 Time History Analysis
It is an analysis of the dynamic response of the structure attach increment of time, when its base is subjected to a specific ground motion time history.
5.1.33 Zone Factor (Z)
It is a factor to obtain the design spectrum depending on the perceived maximum seismic risk characterized by maximum considered earthquake (MCE) in the zone in which the structure is located. The basic zone factors included in this standard are reasonable estimate of effective peak ground acceleration.
5.1.34 Zero Period Acceleration (ZPA)
It is the value of acceleration response spectrum for period below 0.03 s (frequencies above 33 Hz).
4.5Wind Pressure and Forces on Buildings/ Structure
4.5.1 General
The wind load on a building shall be calculated for:
a) the building as a whole;
b) individual structural elements as roofs and walls; and
c) individual cladding units including glazing and their fixings.
4.5.2 Pressure Coefficients
The pressure coefficients are always given for a particular surface or part of the surface of a building. The wind load acting normal to a surface is obtained by multiplying the area of that surface or its appropriate portion by the pressure coefficient ( C p ) ; and the design wind pressure at the height of the surface from the ground. The average values of these pressure coefficients for some building shapes are given in 4.5.2.2 and 4.5.2.3.
Average values of pressure coefficients are given for critical wind directions in one or more quadrants. In order to determine the maximum wind load on the building, the total load should be calculated for each of the critical directions shown from all quadrants.
Where considerable variation of pressure occurs over a surface, it has been sub-divided and mean pressure coefficients given for each of its several parts.
In addition, areas of high local suction (negative pressure concentration) frequently occurring near the edges of walls and roofs are separately shown. Coefficients for the local effects should only be used for calculation of forces on these local areas affecting roof sheeting, glass panels and individual cladding units including their fixtures. They should not be used for calculating force on entire structural elements such as roof, walls or structure as a whole.
1 The pressure coefficients given in the different tables have been obtained mainly from measurements on models in wind tunnels, and the great majority of data available have been obtained in conditions of relatively smooth flow. Where sufficient field data exist as in the case of rectangular buildings, values have been obtained to allow for turbulent flow.
2 In recent years, wall glazing and cladding design has been a source of major concern. Although of less consequence than collapse of the main structures, damage to glass can be hazardous and cause considerable financial losses.
3 For pressure coefficients for structures not covered herein, reference may be made to specialist literature on the subject or advise may be sought from specialists in the subject.
ii) Educational Buildings
a) Class rooms and lecture rooms (not used for assembly purposes)
3.0
2.7
b) Dining rooms, cafeterias and restaurants
3.0¹⁾
2.7
c) Offices, lounges and staff rooms
2.5
2.7
d) Dormitories
2.0
2.7
e) Projection rooms
5.0
—
f) Kitchens
3.0
4.5
g) Toilets and bathrooms
2.0
—
h) Store rooms
5.0
4.5
j) Libraries and archives:
1) Stack room/stack area
6.0 kN/m² for a minimum height of 2.2 m + 2.0 kN/m² per metre height beyond 2.2 m
4.5
2) Reading rooms (without separate storage)
4.0
4.5
3) Reading rooms (with separate storage)
3.0
4.5
k) Boiler rooms and plant rooms — to be calculated but not less than
4.0
4.5
m) Corridors, passages, lobbies, staircases including fire escapes — as per the floor serviced (without accounting for storage and projection rooms) but not less than
4.0
4.5
n) Balconies
Same as rooms to which they give access but with a minimum of 4.0
1.5 metre run concentrated at the outer edge
7.5
4.5
n) Corridors, passages, subject to loads greater than from crowds, such as wheeled vehicles, trolleys and the like corridors, staircases and passages in grandstands
5.0
4.5
v)
Business and Office Buildings (see also 3.2.1)
a) Rooms for general use with separate storage
2.5
2.7
b) Rooms without separate storage
4.0
4.5
c) Banking halls
3.0
2.7
d) Business computing machine rooms (with fixed computers or similar equipment)
3.5
4.5
e) Records/files store rooms and storage space
5.0
4.5
f) Vaults and strong rooms — to be calculated but not less than
5.0
4.5
g) Cafeterias and dinning rooms
3.0¹⁾
2.7
h) Kitchens
3.0
2.7
j) Corridors, passages, lobbies, staircases including fire escapes — as per the floor serviced (excluding stores) but not less than
4.0
4.5
k) Bath and toilets rooms
2.0
—
m) Balconies
Same as rooms to which they give access but with a minimum of 4.0
1.5 metre run concentrated at the outer edge
n) Stationary stores
4.0 for each metre of storage height
9.0
p) Boiler rooms and plant rooms — to be calculated but not less than
5.0
6.7
q) Libraries
See S1 No. (ii)
7.0
b) Cold storage — to be calculated but not less than
5.0 kN/m² per metre of storage height with a minimum of 15 kN/m²
9.0
c) Corridors, passages, staircases including fire escapes — as per the floor serviced but not less than
4.0
4.5
d) Corridors, passages subject to loads greater than from crowds, such as wheeled vehicles, trolleys and the like
5.0
4.5
e) Boiler rooms and plant rooms
7.5
4.5
¹⁾ Where unrestricted assembly of persons is anticipated, the value of UDL should be increased to 4.0 kN/m² ²⁾ With fixed seats' implies that the removal of the seating and the use of the space for other purposes is improbable. The maximum likely load in this case is, therefore, closely controlled. ³⁾ The loading in industrial buildings (workshops and factories) varies considerably and so three loadings under the terms 'light', 'medium' and 'heavy' are introduced in order to allow for more economical designs but the terms have no special meaning in themselves other than the imposed load for which the relevant floor is designed. It is, however, important particularly in the case of heavy weight loads, to assess the actual loads to ensure that they are not in excess of 10 kN/m² ; in case where they are in excess, the design shall be based on the actual loadings. ⁴⁾ For various mechanical handling equipment which are used to transport goods, as in warehouses, workshops, store rooms, etc, the actual load coming from the use of such equipment shall be ascertained and design should cater to such loads.
For all ladle cranes and charging cranes where there is possibility of overloading from production considerations, an overloading factor of 10 percent of the maximum wheel loading shall be taken.
(1)
(2)
All general buildings and structures
50
1.0
1.0
1.0
1.0
1.0
1.0
Temporary sheds, structures such as those used during construction operations (for example, formwork and falsework), structures during construction stages and boundary walls
5
0.82
0.76
0.73
0.71
0.70
0.67
Buildings and structures presenting a low degree of hazard to life and property in the event of failure, such as isolated towers in wooded areas, farm buildings, other than residential buildings
25
0.94
0.92
0.91
0.90
0.90
0.89
Important buildings and structures, such as hospitals, communications buildings/towers and power plant structures
100
1.05
1.06
1.07
1.07
1.08
1.08
k1= XN,PNX50,0.63= A-B [ -(1)/(N) (1-PN) ]A+4B
where
N = mean probable design life of structure in years;
PN = risk level in N consecutive years (probability that the design wind speed is exceeded at least once in N successive years), nominal value = 0.63;
XN, PN = extreme wind speed for given values of N and PN ; and
X50,0.63 = extreme wind speed for N = 50 years and PN = 0.63
A and B are coefficients having the following values for different basic wind speed zones:
Zone
A
B
33 m/s
83.2
9.2
39 m/s
84.2
14.0
44 m/s
88.0
18.0
47 m/s
88.0
20.5
50 m/s
88.8
22.8
55 m/s
90.8
27.3
NOTE — The factor k is based on statistical concepts which take account of the degree of reliability required and period of time in years during which there will be exposure to wind, that is, life of the structure. Whatever wind speed is adopted for design purposes, there is always a probability (however small) that it may be exceeded in a storm of exceptional violence; the greater the period of years over which there will be exposure to wind, the greater is the probability. Higher return periods ranging from 100 to 1 000 years (implying lower risk level) in association with greater periods of exposure may have to be selected for exceptionally important structures, such as nuclear power reactors and satellite communication towers. Equation given above may be used in such cases to estimate k 1 factors for different periods of exposure and chosen probability of exceedence (risk level). The probability level of 0.63 is normally considered sufficient for design of buildings and structures against wind effects and the values of k 1 corresponding to this risk level are given in Table 4.
design of a structure may vary depending on the direction of wind under consideration. Wherever sufficient meteorological information is available about the nature of wind direction, the orientation of any building or structure may be suitably planned.
Terrian, in which a specific structure stands, shall be assessed as being one of the following terrain categories:
Category 1 — Exposed open terrain with few or no obstructions and in which the average height of any objects surrounding the structure is less than 1.5 m.
NOTE — This category includes open sea-coasts and flat treeless plains.
Category 2 — Open terrain with well scattered obstructions having heights generally between 1.5 and 10 m.
NOTE — This is the criterion for measurement of regional basic wind speeds and includes airfields, open parklands and undeveloped sparsely built-up outskirts of towns and suburbs. Open land adjacent to sea coast may also be classified as category 2 due to roughness of large sea waves at high winds.
Category 3 — Terrain with numerous closely spaced obstruction having the size of building-structures up to 10 m in height with or without a few isolated tall structures.
1 This category includes well wooded areas and shrubs, towns and industrial areas fully or partially developed.
2 It is likely that the next higher category than this will not exist in most design situations and that selection of a more severe category will be deliberate.
3 Particular attention must be given to the performance of the obstructions in areas affected by fully developed tropical cyclones. Vegetation, which is likely to be blown down or defoliated, cannot be relied upon to maintain Category 3 conditions. Where such situation may exist, either an intermediate category with velocity multipliers midway between the values for Categories 2 and 3 given in Table 5 or Category 2 should be selected having due regard to local conditions.
Category 4 — Terrain with numerous large high closely spaced obstructions.
NOTE — This category includes large city centres, generally with obstructions above 25 m and well developed industrial complexes.
b) Variation of Wind Speed with Height for Different Sizes of Structure in Different Terrains (k Factor) — Table 5 gives
multiplying factors (k ) by which the basic wind speed given in Fig. 1 shall be multiplied to obtain the wind speed at different heights, in each terrain category for different sizes of buildings/structures.
The buildings/structures are classified into the following three different classes depending upon their size:
Class A — Buildings and/or their components, such as cladding, glazing, roofing etc, having maximum dimension (greatest horizontal or vertical dimension) less than 20 m.
Class B — Buildings and/or their components, such as cladding, glazing, roofing etc, having maximum dimension (greatest horizontal or vertical dimension) between 20 m and 50 m.
Class C — Buildings and/or their components, such as cladding, glazing, roofing etc, having maximum dimension (greatest horizontal or vertical dimension) greater than 50 m.
c) Terrain Categories in Relation to the Direction of Wind — The terrain category used in the design of a building may vary depending on the direction of wind under consideration. Where sufficient meteorological information is available, the basic wind speed may be varied for specific wind direction.
Table 5k Factors to Obtain Design Wind Speed Variation with Height in Different Terrains for Different Classes of Building Structures [Clause 4.4.3.2 (b)]
Height (m)
Terrain Category 1 Class
Terrain Category 2 Class
Terrain Category 3 Class
Terrain Category 4 Class
A
B
C
A
B
C
A
B
C
A
B
C
10
1.05
1.03
0.99
1.00
0.98
0.93
0.91
0.88
0.82
0.80
0.76
0.67
15
1.09
1.07
1.03
1.05
1.02
0.97
0.97
0.94
0.87
0.80
0.76
0.67
20
1.12
1.10
1.06
1.07
1.05
1.00
1.01
0.98
0.91
0.80
0.76
0.67
30
1.15
1.13
1.09
1.12
1.10
1.04
1.06
1.03
0.96
0.97
0.93
0.83
50
1.20
1.18
1.14
1.17
1.15
1.10
1.12
1.09
1.02
1.10
1.05
0.95
100
1.26
1.24
1.20
1.24
1.22
1.17
1.20
1.17
1.10
1.20
1.15
1.05
150
1.30
1.28
1.24
1.28
1.25
1.21
1.24
1.21
1.15
1.24
1.20
1.10
200
1.32
1.30
1.26
1.30
1.28
1.24
1.27
1.24
1.18
1.27
1.22
1.13
250
1.34
1.32
1.28
1.32
1.31
1.26
1.29
1.26
1.20
1.28
1.24
1.16
300
1.35
1.34
1.30
1.34
1.32
1.28
1.31
1.28
1.22
1.30
1.26
1.17
350
1.37
1.35
1.31
1.36
1.34
1.29
1.32
1.30
1.24
1.31
1.27
1.19
400
1.38
1.36
1.32
1.37
1.35
1.30
1.34
1.31
1.25
1.32
1.28
1.20
450
1.39
1.37
1.33
1.38
1.36
1.31
1.35
1.32
1.26
1.33
1.29
1.21
500
1.40
1.38
1.34
1.39
1.37
1.32
1.36
1.33
1.28
1.34
1.30
1.22
1 See 4.4.3.2 (b) for definitions of Class A, Class B and Class C structures.
2 Intermediate values may be obtained by linear interpolation, if desired. It is permissible to assume constant wind speed between two heights for simplicity.
d) Changes in Terrain Categories — The velocity profile for a given terrain category does not develop to full height immediately with the commencement of that terrain category, but develops gradually to height (h ), which increases with the fetch or upwind distance (x)
Fetch and Developed Height Relationship — The relation beween the developed height ( h x ) and the fetch (x) for wind-flow over each of the four terrain categories may be taken as given in Table 6.
For buildings of heights greater than the developed height ( h _ X ) in Table 6, the velocity profile may be determined in accordance with the following:
i) The less or least terrain; or
ii) The method described in Annex D.
Table 6 Fetch and Developed Height Relationship [Clause 4.4.3.2 (b)]
1 Significant cross wind motions may be produced by vortex shedding if the natural frequency of the structure or structural element is equal to the frequency of the vortex shedding within the range of expected wind velocities. In such cases, further analysis should be carried out on the basis of references given in Note 8 of 4.6.1.
2 Unlined welded steel chimney stacks and similar structures are prone to excitation by vortex shedding.
3 Intensification of the effects of periodic vortex shedding has been reported in cases where two or more similar structures are located in close proximity, for example, at less than 20 b apart, where b is the dimension of the structure normal to the wind.
4 The formulae given in 4.6.2.1 (a) and 4.6.2.1 (b) are valid for infinitely long cylindrical structures. The value of S decreases slowly as the ratio of length to maximum transverse width decreases; the reduction being up to about half the value, if the structure is only three times higher than its width. Vortex shedding need not be considered if the ratio of length to maximum transverse width is less than 2.0.
4.5.2.1 Wind load on individual members
When calculating the wind load on individual structural elements such as roofs and walls, and individual cladding units and their fittings, it is essential to take account of the pressure difference between opposite faces of such elements or units. For clad structures, it is, therefore, necessary to know the internal pressure as well as external pressure. Then the wind load, F (in N) acting in a direction normal to the individual structural element or cladding unit is:
F = (C pe - C pi) A p d
where
C pe = external pressure coefficient;
C pi = internal pressure coefficient;
A = surface area of structural element or cladding unit in m2; and
p d = design wind pressure in N / m ²
1 If the surface design pressure varies with height, the surface areas of the structural element may be sub-divided so that the specified pressures are taken over appropriate areas.
2 Positive wind load indicates the force acting towards the structural element and negative away from it.
4.5.2.2 External pressure coefficients
a) Walls — The average external pressure coefficient for the walls of clad buildings of
rectangular plan shall be as given in Table 7. In addition, local pressure concentration coefficients are also given.
b) Pitched Roofs of Rectangular Clad Buildings — The average external pressure coefficients and pressure concentration coefficients for pitched roofs of rectangular clad building shall be as given in Table 8. Where no pressure concentration coefficients are given, the average coefficients apply. The pressure coefficients on the underside of any overhanging roof shall be taken in accordance with 4.5.2.2 (g).
1 The pressure concentration shall be assumed to act outward (suction pressure) at the ridges, eaves, cornices and 90° corners of roofs.
2 The pressure concentration shall not be included with the net external pressure when computing overall loads.
c) Monoslope Roofs of Rectangular Load Buildings — The average pressure coefficient and pressure concentration coefficient for monoslope (lean-to) roofs of rectangular clad buildings shall be as given in Table 9.
d) Canopy Roofs with ¼ < h/w < 1 and 1 < L / w < 3 — The pressure coefficients are given in Tables 10 and 11 separately for monopitch and double pitch canopy roofs, such as open-air parking garages, shelter areas, outdoor areas, railway platforms, stadiums and theatres. The coefficients take account of the combined effect of the wind exerted on and under the roof for all wind directions; the resultant is to be taken normal to the canopy. Where the local coefficients overlap the greater of the two given values should be taken. However, the effect of partial closures of one side and or both sides, such as those due to trains, buses and stored materials shall be foreseen and taken into account.
The solidity ratio ø is equal to the area of obstruction under the canopy divided by the gross area under the canopy, both areas normal to the wind direction. = 0 represents a canopy with no obstructions underneath. ø = 1 represents the canopy fully blocked with contents to the downwind eaves. Values of C p for intermediate solidities may be linearly interpolated between these two extremes, and apply upwind of the position of maximum blockage only. Downwind of the position of maximum blockage the coefficients for = 0 may be used.
In addition to the pressure forces normal to
Table 7External Pressure Coefficients ( C p e ) for Walls of Rectangular Clad Buildings [Clause 4.5.2.2 (a)]
Building Height Ratio
Building Plan Ratio
Elevation
Plan
Wind Angle θ Degree
Cpe for Surface
Local Cpe
A
B
C
D
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(h)/(w) ≤ (1)/(2)
1 < (l)/(w) ≤ (3)/(2)
090
+0.7-0.5
-0.2-0.5
-0.5+0.7
-0.5-0.2
-0.8
(3)/(2) < (l)/(w) < 4
u
090
+0.7-0.5
-0.25-0.5
-0.6+0.7
-0.6-0.1
-1.0
(1)/(2) < (h)/(w) ≤ (3)/(2)
1 < (l)/(w) ≤ (3)/(2)
090
+0.7-0.6
-0.25-0.6
-0.6+0.7
-0.6-0.25
-1.1
(3)/(2) < (l)/(w) < 4
090
+0.7-0.5
-0.3-0.5
-0.7+0.7
-0.7-0.1
-1.1
(3)/(2) < 1 (h)/(w) < 6
1 < (l)/(w) ≤ (3)/(2)
090
+0.8-0.8
-0.25-0.8
-0.8+0.8
-0.8-0.25
-1.2
(3)/(2) < (l)/(w) < 4
090
+0.7-0.5
-0.4-0.5
-0.7+0.8
-0.7-0.1
-1.2
(h)/(w) ≥ 6
(l)/(w) = (3)/(2)
090
+0.95-0.8
-1.85-0.8
-0.9+0.9
-0.9-0.85
-1.25
(l)/(w) = 1.0
090
+0.95-0.7
-0.25-0.7
-0.7+0.95
-0.7-1.25
-1.25
(l)/(w) = 2
090
+0.85-0.75
-0.75-0.75
-0.75+0.85
-0.75-0.75
-1.25
NOTE — h is the height of eaves or parapet, l is the greater horizontal dimension of a building and w is the lesser horizontal dimension of a building.
Table 8External Pressure Coefficients ( C p e ) for Pitched Roofs of Rectangular Clad Buildings [Clause 4.5.2.2 (b)]
Building Height Ratio
Roof Angle degrees
Wind Angle θ 0°
Wind Angle θ 90°
Local Coefficients
EF
GH
EG
FH
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(h)/(w) ≤ (1)/(2)
0
-0.8
-0.4
-0.8
-0.4
-2.0
-2.0
-2.0
—
5
-0.9
-0.4
-0.8
-0.4
-1.4
-1.2
-1.2
-1.0
10
-1.2
-0.4
-0.8
-0.6
-1.4
-1.4
-1.2
20
-0.4
-0.4
-0.7
-0.6
-1.0
-1.2
30
0
-0.4
-0.7
-0.6
-0.8
-1.1
45
+0.3
-0.5
-0.7
-0.6
-1.1
60
+0.7
-0.6
-0.7
-0.6
-1.1
(1)/(2) < (h)/(w) ≤ (3)/(2)
0
-0.8
-0.6
-1.0
-0.6
-2.0
-2.0
-2.0
—
5
-0.9
-0.6
-0.9
-0.6
-2.0
-2.0
-1.5
-1.0
10
-1.1
-0.6
-0.8
-0.6
-2.0
-2.0
-1.5
-1.2
20
-0.7
-0.5
-0.8
-0.6
-1.5
-1.5
-1.5
-1.0
30
-0.2
-0.5
-0.8
-0.8
-1.0
-1.0
45
+0.2
-0.5
-0.8
-0.8
NOTES
1 h is the height to caves or parapet, w is the lesser horizontal dimension of a building.
2 Where no local coefficients are given the overall coefficients apply.
OVERALL COEFFICIENTS
Table 9 External Pressure Coefficients ( C p e ) for Monoslope Roofs for Rectangular [Clause 4.5.2.2 (c)]
y = h or 0.15 w, whichever is the lesser
NOTE — Area H and area L refer to the whole quadrant.
Roof Angle α Degree
Wind Angle θ
0°
45°
90°
135°
180°
H
L
H
L
H & L
H & L
H
L
H
L
Applies to length w/2 from wind ward end
Applies to remainder
5
-1.0
-0.5
-1.0
-0.9
-1.0
-0.5
-0.9
-1.0
-0.5
-1.0
10
-1.0
-0.5
-1.0
-0.8
-1.0
-0.5
-0.8
-1.0
-0.4
-1.0
15
-0.9
-0.5
-1.0
-0.7
-1.0
-0.5
-0.6
-1.0
-0.3
-1.0
20
-0.8
-0.5
-1.0
-0.6
-0.9
-0.5
-0.5
-1.0
-0.2
-1.0
25
-0.7
-0.5
-1.0
-0.6
-0.8
-0.5
-0.3
-0.9
-0.1
-0.9
30
-0.5
-0.5
-1.0
-0.6
-0.8
-0.5
-0.1
-0.6
0
-0.6
Roof Angle
LOCAL COEF
FICIENTS C<sub>pe</sub>
Degree
H<sub>1</sub>
H<sub>2</sub>
L<sub>1</sub>
L<sub>2</sub>
H
L
5
-2.0
-1.5
-2.0
-1.5
-2.0
-2.0
10
-2.0
-1.5
-2.0
-1.5
-2.0
-2.0
15
-1.8
-0.9
-1.8
-1.4
-2.0
-2.0
20
-1.8
-0.8
-1.8
-1.4
-2.0
-2.0
25
-1.8
-0.7
-0.9
-0.9
-2.0
-2.0
30
-1.8
-0.5
-0.5
-0.5
-2.0
-2.0
NOTE — h is the height to eaves at lower side, l is greater horizontal dimension of a building and w is the lesser horizontal dimension of a building.
Maximum (Largest +ve) and Minimum (Largest -ve) Pressure Coefficients
Overall coefficients
Local coefficients
Degree
-20
All values of ∅
+0.7
+0.8
+1.6
+0.6
+1.7
-15
+0.5
+0.6
+1.5
+0.7
+1.4
-10
+0.4
+0.6
+1.4
+0.8
+1.1
-5
+0.3
+0.5
+1.5
+0.8
+0.8
+5
+0.3
+0.6
+1.8
+1.3
+0.4
+10
+0.4
+0.7
+1.8
+1.4
+0.4
+15
+0.4
+0.9
+1.9
+1.4
+0.4
+20
+0.6
+1.1
+1.9
+1.5
+0.4
+25
+0.7
+1.2
+1.9
+1.6
+0.5
+30
+0.9
+1.3
+1.9
+1.6
+0.7
-20
∅ = 0
-0.7
-0.9
-1.3
-1.6
-0.6
∅ = 1
-0.9
-1.2
-1.7
-1.9
-1.2
-15
∅ = 0
-0.6
-0.8
-1.3
-1.6
-0.6
∅ = 1
-0.8
-1.1
-1.7
-1.9
-1.2
-10
∅ = 0
-0.6
-0.8
-1.3
-1.5
-0.6
∅ = 1
-0.8
-1.1
-1.7
-1.9
-1.3
-5
∅ = 0
-0.5
-0.7
-1.3
-1.6
-0.6
∅ = 1
-0.8
-1.5
-1.7
-1.9
-1.4
+5
∅ = 0
-0.6
-0.6
-1.4
-1.4
-1.1
∅ = 1
-0.9
-1.3
NOTE — Each slope of a duopitch canopy should be able to withstand forces using both the maximum and the minimum coefficients, and the whole canopy should be able to support forces using one slope at the maximum coefficient with the other slope at the minimum coefficient. For duopitch canopies the centre of pressure should be taken to act at the centre of each slope.
the canopy, there will be horizontal loads on the canopy due to the wind pressure on any fascia and to friction over the surface of the canopy. For any wind direction, only the greater of these two forces need be taken into account. Fascia loads should be calculated on the area of the surface facing the wind, using a force coefficient of 1.3. Frictional drag should be calculated using the coefficients given in 4.5.3.1.
NOTE — Tables 12 to 17 may be used to get internal and external pressure coefficients for pitches and troughed free roofs for some specific cases for which aspect ratios and roof slopes have been specified. However, while using Tables 12 to 17 any significant departure from it should be investigated carefully. No increase shall be made for local effects except as indicated.
e) Curved Roofs — For curved roofs, the external pressure coefficients shall be as given in Table 18. Allowance for local effects shall be made in accordance with Table 8.
Table 12 Pressure Coefficients (Top and Bottom) for Pitched Roofs, α = 30° [Clause 4.5.2.2 (d)]
NOTE — When the wind is blowing normal to the gable ends, C p e m a y be taken as equal to –0.7 for the full width of the roof over a length of l/2 from the gable ends and –0.5 for the remaining portion.
f) Pitched and Saw-Tooth Roofs of Multi-span Buildings — For pitched and saw-tooth roofs of multi-span buildings, the external average pressure coefficients and pressure concentration coefficients shall be as given
in Tables 19 and 20 respectively, provided that all spans shall be equal and the height to the eaves shall not exceed the span.
NOTE — Evidence on multi-span buildings is fragmentary. Any departure given in Tables 19 and 20 should be investigated separately.
Table 19 External Pressure Coefficients ( C p e ) for Pitched Roofs of Multi-span Buildings (All Spans Equal) with h > w ′
Roof Angle degrees
Wind Angle degrees
First Span
First Intermediate Span
Other Intermediate Span
End Span
Local Coefficient
a
b
c
d
m
n
x
z
510203045
0
-0.9-1.1-0.7-0.2+0.3
-0.6-0.6-0.6-0.6-0.6
-0.4-0.4-0.4-0.4-0.6
-0.3-0.3-0.3-0.3-0.4
-0.3-0.3-0.3-0.2-0.2
-0.3-0.3-0.3-0.3-0.4
-0.3-0.3-0.3-0.2-0.2
-0.3-0.4-0.5-0.5-0.5
-2.0
-1.5
Roof Angle degrees
Wind Angle degrees
Distance
h1
h2
h3
Up to 45
90
-0.8
-0.6
-0.2
Frictional drag: when wind angle = 0o horizontal forces due to frictional drag are allowed for in the above values; when wind angle = 90o allow for frictional drag in accordance with 4.5.3.1.
Table 20 External Pressure Coefficients ( C p e ) for Saw-Tooth Roofs of Multispan Buildings (All Spans Equal) with h > w ′
[Clause 4.5.2.2 (f)]
ROOF PLAN
SECTION
Wind Angle degrees-
First Span
First Intermediate Span
Other Intermediate Span
End Span
Local Coefficient
a
b
c
d
m
n
x
z
0180
+0.6-0.5
-0.7-0.3
-0.7-0.3
-0.4-0.3
-0.3-0.4
-0.2-0.6
-0.1-0.6
-0.3-0.1
-2.0
-1.5
Frictional drag: when wind angle - = 0o horizontal forces due to frictional drag are allowed for in the above values; when wind angle - = 90o allow for frictional drag in accordance with 4.5.3.1.
NOTE — Evidence on these buildings is fragmentary and any departures from the cases given should be investigated separately.
Position of Periphery, θ in degrees
Pressure Coefficient, Cpe
H/D = 25
H/D = 7
H/D = 1
0
1.0
1.0
1.0
15
0.8
0.8
0.8
30
0.1
0.1
0.1
45
-0.9
-0.8
-0.7
60
-1.9
-1.7
-1.2
75
-2.5
-2.2
-1.6
90
-2.6
-2.2
-1.7
105
-1.9
-1.7
-1.2
120
-0.9
-0.8
-0.7
135
-0.7
-0.6
-0.5
150
-0.6
-0.5
-0.4
165
-0.6
-0.5
-0.5
180
-0.6
-0.5
-0.4
Table 21 External Pressure Distribution Coefficients Around Cylindrical Structures [Clause 4.5.2.2 (h)]
g) Pressure Coefficients on Overhangs from Roofs — The pressure coefficients on the top overhanging portion of the roofs shall be taken to be the same as that of the nearest top portion of the non-pressure coefficients for the underside surface of the overhanging portions shall be taken as follows and shall be taken as positive if the overhanging portion is on the windward side:
1.25, if the overhanging slopes; downwards;
1.0, if the overhanging is horizontal; and
0.75, if the overhanging slopes upwards. For overhanging portions on sides other than windward side, the average pressure coefficients on the adjoining walls may be used.
h) Cylindrical Structures — For the purpose of calculating the wind pressure distribution
around a cylindrical structure of circular cross-section, the value of external pressure coefficients given in Table 21 may be used provided that the Raynolds number is greater than 10 000. They may be used for wind blowing normal to the axes of cylinders having axis normal to the ground plane (that is, chimneys and silos) and cylinders having their axis parallel to the ground plane (that is, horizontal tanks) provided that the clearance between the tank and the ground is not less than the diameter of the cylinder.
h is the height of a vertical cylinder or length of a horizontal cylinder. Where there is a free flow of air around both ends, h is to be taken as half the length when calculating h/D ratio. 1) –0.8, where h/D is not less than 0.3; and 2) –0.5, where h/D is less than 0.3.
k)
j) Roofs and Bottom of Cylindrical Related Structure — The external pressure coefficients for roofs and bottoms of cylindrical elevated structures shall be as given in Table 22 (see also Fig. 2).
The total resultant load (P) acting on the roof of the structure is given by the following formula:
P = 0. 7 8 5 D ² (C pi - C pe) p d
The resultant of P for roofs lies at 0.1 D from the centre of the roof on the windward side.
Combined Roofs and Roofs with a Sky Light — The average external pressure coefficients for combined roofs and roofs with a sky light are shown in Table 23.
1 5 h + 0. 2 D FOR 0. 2 < h / D < 2
(For force coefficient corresponding to shell portion see Table 23)
FIG. 2 EXTERNAL PRESSURE COEFFICIENTS ON THE UPPER ROOF SURFACE OF SINGULAR CIRCULAR STANDING ON THE GROUND
Table 22 External Pressure Coefficients for Roofs and Bottoms of Cylindrical Structures
[Clause 4.5.5.2 (j)]
Coefficient of External Pressure, C p e
Structure According to
Shape
a, b and c
d
H/D
Roof
(Z/H) -1
Roof
Bottom
0.5
-0.65
1.00
-0.75
-0.8
1.0
-1.00
1.25
-0.75
-0.7
2.0
-1.00
1.50
-0.75
-0.6
Total force acting on the roof of the structure, P = 0.785 D² (Cpi - Cpe)pd The resultant of P lies eccentrically, e = 0.1 D.
Table 23 External Pressure Coefficients, C p e for Combined Roofs and Roofs with a Sky Light [Clause 4.5.2.2 (k)]
a) Combined Roofs
Values of C p e
Portion
Direction 1 Direction 2
a
From the Diagram C<sub>pe</sub> = -0.5, h1/h2 < 1.5 -0.4
b
C<sub>pe</sub> = -0.7, h1/h2 > 1.5
c and d
See Table 5
e
See 4.5.2.2 (g)
Table 23 — Concluded
b) Roofs with a Sky Light
m) Grandstands — The pressure coefficients on the roof (top and bottom) and rear wall of a typical grandstand roof, which is open on three sides, is given in Table 24. The pressure coefficients are valid for a particular ratio of dimensions as specified in Table 24, but may be used for deviations up to 20 percent. In general, the maximum wind load occurs, when the wind is blowing into the open front of the stand causing positive pressure under the roof and negative pressure on the roof.
n) Upper Surface of Round Silos and Tanks — The pressure coefficients on the upper surface of round silos and tanks standing on ground shall be as given in Fig. 2.
p) Spheres — The external pressure coefficients for spheres shall be as given in Table 25.
4.5.2.3 Internal pressure coefficients
Internal air pressure in a building depends upon the degree of permeability of the cladding to the flow of air. The internal air pressure may be positive or negative depending on the direction of flow of air in relation to the openings in the buildings.
a) In the case of buildings where the claddings permit the flow of air with openings not more than about 5 percent of the wall areas but where there are no large openings, it is necessary to consider the possibility of the internal pressure being positive or negative.
(h : b :l = 0.8: 1: 2.2)
Table 24 Pressure Coefficients at Top and Bottom Roof of Grandstands Open Three Sides (Roof = 5°)
[Clause 4.5.2.2 (m)]
Front and Back of Wall
θ
J
K
L
M
0o
+0.9
-0.5
+0.9
-0.5
45o
+0.8
-0.6
+0.4
-0.4
135o
-1.1
+0.6
-1.0
+0.4
180o
-0.3
+0.9
-0.3
+0.9
60o
Mw - Cp of K = -1.0
60o
Mw - Cp of J = +1.0
( Shaded area to scale )
Top and Bottom of Roof
θ
A
B
C
D
E
F
G
H
0o
-1.0
+0.9
-1.0
+0.9
-0.7
+0.9
+0.7
+0.9
45o
-1.0
+0.7
-0.7
+0.4
-0.5
+0.8
-0.5
+0.3
135o
-0.4
-1.1
-0.7
-1.0
-0.9
-1.1
-0.9
-1.0
180o
-0.6
-0.3
-0.6
-0.3
-0.6
-0.3
-0.6
-0.3
45o
MR - Cp (top) = -2.0
45o
MR - Cp (bottom) = +1.0
Table 25 External Pressure Distribution Coefficients Around Spherical Structures [Clause 4.5.2.2 (p)]
C<sub>f</sub> = 0.5 for DV<sub>z</sub> < 7 = 0.2 for DV<sub>z</sub> > 7
Two design conditions shall be examined, one with an internal pressure coefficient of +0.2 and another with an internal pressure coefficient of –0.2.
The internal pressure coefficient is algebraically added to the external pressure coefficient and the analysis, which indicates greater distress of the member, shall be adopted. In most situations, a simple inspection of the sign of the external pressure will at once indicate the proper sign of the internal pressure coefficient to be taken for design.
NOTE — The terms normal permeability relates to the flow of air commonly afforded by the claddings not only through the open windows and doors, but also
through the slits round the closed windows and doors and through chimneys, ventilators and through the joints between roof coverings, the total open area being less than 5 percent of the area of the walls having the openings.
b) Building with medium and large openings — Buildings with medium and large openings may also exhibit either positive or negative internal pressure depending upon the direction of wind. Buildings with medium openings between about 5 to 20 percent of wall area shall be examined for an internal pressure coefficient of +0.5 and later with an internal pressure coefficient of –0.5, and the members shall be adopted. Buildings with large openings, that is, openings larger than
20 percent of the wall area shall be examined once with an internal pressure coefficient of +0.7 and again with an internal pressure coefficient of –0.7, and the analysis which produces greater distress on the members shall be adopted.
Buildings with one open side or openings exceeding 20 percent of wall area may be assumed to be subjected to internal positive pressure or suction similar to those for buildings with large openings. A few examples of buildings with one sided openings are shown in Fig. 3 indicating values of internal pressure coefficients with respect to direction of wind.
c) In buildings with roofs but no walls, the roofs will be subjected to pressure from both inside
and outside, and the recommendations shall be as given in 4.5.2.2.
4.5.3 Force Coefficients
The value of force coefficients apply to a building or structure as a whole, and when multiplied by the effective frontal area, A e of the building or structure and by design wind pressure, p d give the total wind load on that particular building or structure.
F = CfAepd
where F is the force acting in a direction specified in the respective tables and C f is the force coefficient for the building.
1 The value of the force coefficient differs for the wind acting on different faces of a building or structure. In order to
FIG. 3 LARGE OPENING IN BUILDINGS (VALUES OF COEFFICIENT OF INTERNAL PRESSURE) (WITH TOP CLOSED)
determine the critical load, the total wind load should be calculated for each wind direction.
2 If surface design pressure varies with height, the surface area of the building/structure may be sub-divided so that specified pressure are taken over appropriate areas.
3 In tapered buildings/structures, the force coefficients shall be applied after sub-dividing the building/structure into suitable number of strips and the load on each strip calculated individually, taking the area of each strip as A .
4 Force coefficients for structures not covered herein, reference may be made to specialist literature on the subject or advise may be sought from specialists in the subject.
4.5.3.1 Frictional drag
In certain buildings of special shape, a force due to frictional drag shall be taken into account, in addition to those loads specified in 4.5.2. For rectangular clad buildings, this addition is necessary only where the ratio d/h or d/b is greater than 4. The frictional drag force, F ′ in the direction or the wind given by the following formulae:
If h ≤ b, F ′ = C f′ (d - 4 h) b p d + C f′ (d - 4 h) 2 h p d
If h > b, F ′ = C f′ (d - 4 b) b p d + C f′ (d - 4 b) 2 h p d
The first term in each case gives the drag on the roof and the second on the walls. The value of C f ′ has the following values:
C'= 0.01 for smooth surfaces without corrugations or ribs across the wind direction;
C'= 0.02 for surfaces with corrugations or ribs across the wind direction;
C f ′ = 0.04 for surfaces with ribs across the wind direction.
For other buildings, the frictional drag has been indicated, where necessary, in the tables of pressure coefficients and force coefficients.
4.5.3.2 Force coefficients for clad buildings
a) Clad buildings of uniform section — The overall force coefficients for rectangular clad buildings of uniform section with flat roofs in uniform flow shall be as given in Fig. 4 and for other clad buildings of uniform section (without projections, except where otherwise shown) shall be as given in Table 26.
b) Buildings of circular shapes — Force coefficients for buildings of circular cross-section shall be as given in Table 27 (see Fig. 5 and Annex F).
c) Low walls and hoardings — Force coefficients for low walls and hoardings less than 15 m high shall be as given in Table 27 provided the height shall be measured from the ground to the top of the walls or hoarding, and provided that for walls or hoardings above
the ground the clearance between the wall or hoarding and the ground shall be not less than 0.25 times the vertical dimension of the wall or hoarding.
To allow for oblique winds the design shall also be checked for the net pressure normal to the surface varying linearly from a maximum of 1 . 7 C f at the up wind edge to 0.44 C f at the down wind edge.
The wind load on appurtenances and supports for hoardings shall be accounted for separately by using the appropriate net pressure coefficients. Allowance shall be made for the shielding effects of one element or another.
d) Solid circular shapes mounted on a surface — The force coefficients for solid circular shapes mounted on a surface shall be as given in Fig. 6.
4.7Gust Factor (GF) or Gust Effectiveness Factor (GEF) Method
4.7.1 Application
Only the method of calculating load along wind or drag load by using gust factor method is given in the section since methods for calculating load across-wind or other components are not fully matured for all types of structures. However, it is permissible for a designer to use gust factor method to calculate all components of load on a structure using any available theory. However, such a theory must take into account the random nature of atmospheric wind speed.
NOTE — It may be noted that investigations for various types of wind induced oscillations out lined in 4.6 are in no way related to the use of gust factor method given in 4.7. Although study of 4.6 is needed for using gust factor method.
4.7.2 Hourly Mean Wind
Use of the existing theories of gust factor method require a knowledge of the maximum of the wind speeds averaged over one hour at a particular site. Hourly mean wind speeds at different heights over different terrains is given in Table 28.
NOTE — It must also be recognized that the ratio of hourly mean wind (HMW) to peak gust (PG) given in Table 28 may not be obtainable in India since extreme wind occurs mainly due to cyclones and thunderstorms, unlike in UK and Canada where the mechanism is fully developed pressure system. However Table 28 may be followed at present for the estimation of the hourly mean wind speed till more reliable values become available.
Table 28Hourly Mean Wind Speed Factor k z in Different Terrains for Different Heights (Clause 4.7.2)
Heightm(1)
Terrain
Category 1(2)
Category 2(3)
Category 3(4)
Category 4(5)
10
0.78
0.67
0.50
0.24
15
0.82
0.72
0.55
0.24
20
0.85
0.75
0.59
0.24
30
0.88
0.79
0.64
0.34
50
0.93
0.85
0.70
0.45
100
0.99
0.92
0.79
0.57
150
1.03
0.96
0.84
0.64
200
1.06
1.00
0.88
0.68
250
1.08
1.02
0.91
0.72
300
1.09
1.04
0.93
0.74
350
1.11
1.06
0.95
0.77
400
1.12
1.07
0.97
0.79
450
1.13
1.08
0.98
0.81
500
1.14
1.09
0.99
0.82
4.7.2.1 Variation of hourly mean wind speed with height
The variation of hourly mean wind speed with height shall be calculated as follows:
Vz=Vb
4.7.3 Along Wind Load
Along wind load on a structure on a strip area ( A e ) at any height (Z) is given by:
Fz=CfAe
5.3General Principles and Design Criteria
5.3.1 General Principles
5.3.1.1 Ground motion
The characteristics (intensity, duration, etc) of seismic ground vibrations expected at any location depends upon the magnitude of earthquake, its depth of focus, distance from the epicentre, characteristics of the path through which the seismic waves travel, and the soil strata on which the structure stands. The random earthquake ground motions, which cause the structure to vibrate, can be resolved in any three mutually perpendicular directions. The predominant direction of ground vibration is usually horizontal.
Earthquake-generated vertical inertia forces are to be considered in design unless checked and proven by specimen calculations to be not significant. Vertical acceleration should be considered in structures with large spans, those in which stability is a criterion for design, or for overall stability analysis of structures. Reduction in gravity force due to vertical component of ground motions can be particularly detrimental in cases of prestressed horizontal members and of cantilevered members. Hence, special attention should be paid to the effect of vertical component of the ground motion on prestressed or cantilevered beams, girders and slabs.
5.3.1.2 The response of a structure to ground vibrations is a function of the nature of foundation soil, materials, form, size and mode of construction of structures; and the duration and characteristics of ground motion. This standard specifies design forces for structures standing on rocks or soils which do not
settle, liquefy or slide due to loss of strength during ground vibrations.
5.3.1.3 The design approach adopted in this standard is to ensure that structures possess at least a minimum strength to withstand minor earthquakes (<DBE), which occur frequently, without damage; resist moderate earthquakes (DBE) without significant structural damage though some non-structural damage may occur; and aims that structures withstand a major earthquake (MCE) without collapse. Actual forces that appear on structures during earthquakes are much greater than the design forces specified in this Code. However, ductility, arising from inelastic material behaviour and detailing, and overstrength, arising from the additional reserve strength in structures over and above the design strength, are relied upon to account for this difference in actual and design lateral loads.
Reinforced and prestressed concrete members shall be suitably designed to ensure that premature failure due to shear or bond does not occur, subject to the provisions of Part 6 ‘Structural Design, Section 5 Concrete’. Provisions for appropriate ductile detailing of reinforced concrete members shall be in accordance with good practice [6-1(4)].
In steel structures, members and their connections should be so proportioned that high ductility is obtained, vide SP 6(6), avoiding premature failure due to elastic or inelastic buckling of any type.
The specified earthquake loads are based upon post-elastic energy dissipation in the structure and because of this fact, the provision of this Code for design, detailing and construction shall be satisfied even for structures and members for which load combinations that do not contain the earthquake effect indicate larger demands than combinations including earthquake.
5.3.1.4 Soil-structure interaction
The soil-structure interaction refers to the effects of the supporting foundation medium on the motion of structure. The soil-structure interaction may not be considered in the seismic analysis for structures supported on rock or rock-like material.
5.3.1.5 The design lateral force specified in this Code shall be considered in each of the two orthogonal horizontal directions of the structure. For structures which have lateral force resisting elements in the two orthogonal directions only, the design lateral force shall be considered along one direction at a time, and not in both directions simultaneously. Structures, having lateral force resisting elements (for example, frames, shear walls) in directions other than the two orthogonal directions, shall be analysed considering the load combinations specified in 5.3.3.2.
Where both horizontal and vertical seismic forces are
taken into account, load combinations specified in 5.3.3.3 shall be considered.
5.3.1.6 Equipment and other systems, which are supported at various floor levels of the structure, will be subjected to motions corresponding to vibration at their support points. In important cases, it may be necessary to obtain floor response spectra for design of equipment supports. For detail reference be made to good practice [6-1(5)]
5.3.1.7 Additions to existing structures
Additions shall be made to existing structures only as follows:
a) An addition that is structurally independent from an existing structures shall be designed and constructed in accordance with the seismic requirements for new structures.
b) An addition that is not structurally independent from an existing structure shall be designed and constructed such that the entire structure conforms to the seismic force resistance requirements for new structures unless the following three conditions are complied with:
The addition shall comply with the requirements for new structures;
The addition shall not increase the seismic forces in any structural elements of the existing structure by more than 5 per cent unless the capacity of the element subject to the increased force is still in compliance with this standard; and
The addition shall not decrease the seismic resistance of any structural element of the existing structure unless reduced resistance is equal to or greater than that required for new structures.
5.3.1.8 Change in occupancy
When a change of occupancy results in a structure being reclassified to a higher importance factor (I), the structure shall conform to the seismic requirements for a new structure with the higher importance factor.
5.3.2 Assumptions
The following assumptions shall be made in the earthquake-resistant design of structures:
a) Earthquake causes impulsive ground motions, which are complex and irregular in character, changing in period and amplitude each lasting for a small duration. Therefore, resonance of the type as visualized under steady-state sinusoidal excitations, will not occur as it would need time to build up such amplitudes. NOTE — However, there are exceptions where
resonance-like conditions have been seen to occur between long distance waves and tall structures founded on deep soft soils.
b) Earthquake is not likely to occur simultaneously with wind or maximum flood or maximum sea waves.
c) The value of elastic modulus of materials, wherever required, may be taken as for static analysis unless a more definite value is available for use in such condition (see Part 6 ‘Structural Design, Section 5 Concrete and Section 6 Steel’.
5.3.3 Load Combination and Increase in Permissible Stresses
5.3.3.1 Load combinations
When earthquake forces are considered on a structure, these shall be combined as per 5.3.3.1.1 and 5.3.3.1.2 where the terms DL, IL and EL stand for the response quantities due to dead load, imposed and designated earthquake load respectively.
5.3.3.1.1 Load factors for plastic design of steel structures
In the plastic design of steel structures, the following load combinations shall be accounted for:
a) 1.7 (DL + IL)
b) 1.7 (DL ± EL)
c) 1 . 3 ( D L + I L ± E L )
5.3.3.1.2 Partial safety factors for limit state design of reinforced concrete and prestressed concrete structures
In the limit state design of reinforced and prestressed concrete structures, the following load combinations shall be accounted for:
a) 1.5 (DL + IL)
b) 1.2 (DL+ IL ± EL)
c) 1 . 5 ( D L ± E L )
d) 0.9 D L ± 1 . 5 E L
5.3.3.2 Design horizontal earthquake load
5.3.3.2.1 When the lateral load resisting elements are oriented along orthogonal horizontal direction, the structure shall be designed for the effects due to full design earthquake load in one horizontal direction at time.
5.3.3.2.2 When the lateral load resisting elements are not oriented along the orthogonal horizontal directions, the structure shall be designed for the effects due to full design earthquake load in one horizontal direction plus 30 percent of the design earthquake load in the other direction.
NOTE — For instance, the building should be designed for (± E L x ± 0 . 3 E L y as well as ( ± 0 . 3 E L x ± E L y ) , where x and y are
two orthogonal horizontal direction, EL in 5.3.3.1.1 and 5.3.3.1.2 shall be replaced by ( EL ± 0 . 3 EL ) or ( E L ± 0 . 3 E L )
5.3.4 Design Spectrum
5.3.4.1 For the purpose of determining seismic forces, the country is classified into four seismic zones as shown in Fig. 11.
5.3.4.2 The design horizontal seismic coefficient A h for a structure shall be determined by the following expression:
Ah=2RgZIS
60
+0.6
-0.5
-0.8
-0.8
(3)/(2) < (h)/(w) < 6
0
-0.7
-0.6
-0.9
-0.7
-2.0
-2.0
-2.0
—
5
-0.7
-0.6
-0.8
-0.8
-2.0
-2.0
-1.5
-1.0
10
-0.7
-0.6
-0.8
-0.8
-2.0
-2.0
-1.5
-1.2
20
-0.8
-0.6
-0.8
-0.8
-1.5
-1.5
-1.5
-1.2
30
-1.0
-0.5
-0.8
-0.7
-1.5
40
-0.2
-0.5
-0.8
-0.7
-1.0
50
+0.2
-0.5
-0.8
-0.7
60
+0.5
-0.5
-0.8
-0.7
-1.8
-1.8
-2.1
+10
∅ = 0
-0.7
-0.7
-1.5
-1.4
-1.4
∅ = 1
-1.1
-1.4
-2.0
-1.8
-2.4
+15
∅ = 0
-0.8
-0.9
-1.7
-1.4
-1.8
∅ = 1
-1.2
-1.5
-2.2
-1.9
-2.8
+20
∅ = 0
-0.9
-1.2
-1.8
-1.4
-2.0
∅ = 1
-1.3
-1.7
-2.3
-1.9
-3.0
+25
∅ = 0
-1.0
-1.4
-1.9
-1.4
-2.0
∅ = 1
-1.4
-1.9
-2.4
-2.1
-3.0
+30
∅ = 0
-1.0
-1.4
-1.9
-1.4
-2.0
∅ = 1
-1.4
-2.1
-2.6
-2.2
-3.0
k
1
k2
k3
where
V z = hourly mean wind speed in m/s at height z,
V b = regional basic wind speed in m/s (see Fig. 1),
k ₁ = probability factor (Table 4),
k 2 = terrain and height factor (Table 28), and
k 3 = topography factor (4.4.3.3).
p
z
G
where
F z = along wind load on the structure at any
height Z corresponding to strip area A e l ,
C f = force coefficient for the building,
A e = effective frontal area considered for the structure at height Z.
p z = design pressure at height Z due to mean hourly wind obtained as 0.6 V z 2 (N/m2), and
G=gust factormean loadpeak loadand is given by:
G=1+gfr[B(1+ϕ)2+βSE]
where
g f = peak factor defined as the ratio of the expected peak value to the root mean value of a fluctuating load, and
r = a roughness factor which is dependent on the size of the structure in relation to the ground roughness.
The value of ° g f r is given in Fig. 7.
FIG. 7 VALUES OF E f r AND L h
B is a background factor indicating a measure of the slowly varying component of the fluctuating wind load and is obtained from Fig. 8.
( S E )/( β ) is a measure of the resonant component of the fluctuating wind load.
E is a measure of the available energy in the wind stream at the natural frequency of the structure (see Fig. 9).
S is size reduction factor (see Fig. 10).
β is the damping coefficient (as a fraction of critical damping) of the structure (see Table 29).
φ = g r √( B ) 4 and is to be accounted only for buildings less than 75 m high in terrain category 4 and for buildings less than 25 high in terrain category 3, and is to be taken as zero in all other cases.
In Fig. 8 and 10,
λ=CzhCybandfo=VhCzfoh
where
C _ y = lateral correlation constant which may be taken as 10 in the absence of more precise load data;
C z = longitudinal correlation constant which may be taken as 12 in the absence of more precise load data;
b = breadth of a structure normal to the wind stream;
h = height of a structure;
V = hourly mean wind speed at height Z;
f o = natural frequency of the structure in the fundamental mode; and
L h = a measure of turbulence length scale (see Fig. 7)
Table 29Suggested Values of Damping Coefficient (Clause 4.7.3)
Nature of Structure
---
(1)
(2)
Welded steel structures
0.010
Bolted steel structures
0.020
Reinforced concrete structures
0.016
The peak acceleration along the wind direction at the top of the structure is given by the following formula:
a=(2πfo)2xˉgfrβSE
where
x = mean deflection at the position where the acceleration is required.
x
y
y
x
5.3.3.3 Design vertical earthquake load
When effects due to vertical earthquake loads are to be considered, the design vertical force shall be calculated in accordance with 5.3.4.5.
5.3.3.4 Combination for two or three component motion
5.3.3.4.1 When responses from the three earthquake components are to be considered, the responses due to each components may be combined using the assumption that when the maximum response from one component occurs, the responses from the other two component are 30 percent of their maximum. All possible combinations of the three components ( E L x , E L γ and E L _ Z ) including variations in sign (plus or minus) shall be considered. Thus, the response due earthquake force (EL) is the maximum of the following three cases:
a)b)c)±ELx±0.3ELy±0.3ELz±EL
Where x and y are two orthogonal directions and z is vertical direction.
5.3.3.4.2 As an alternative to the procedure in 5.3.3.4.1, the response (EL) due to the combined effect of the three components can be obtained on the basis of ‘square root of the sum of the square (SRSS)’ that is
E L = √ (E L x) ² + (E L y) ² + (E L z) ²
NOTE — The combination procedure of 5.3.3.4.1 and 5.3.3.4.2 apply to the same response quantity (say, moment in a column about its major axis, or storey shear in a frame) due to different components of the ground motion.
5.3.3.4.3 When two component motions (say one horizontal and one vertical, or only two horizontal) are combined, the equations in 5.3.3.4.1 and 5.3.3.4.2 should be modified by deleting the term representing the response due to the component of motion not being considered.
5.3.3.5 Increase in permissible stresses
5.3.3.5.1 Increase in permissible stresses in materials
When earthquake forces are considered along with other normal design forces, the permissible stresses in material, in the elastic method of design, may be increased by onethird. However, for steels having a definite yield stress, the stress be limited to the yield stress; for steels without a definite yield point, the stress will be limited to 80 percent of the ultimate strength or 0.2 percent proof stress, whichever is smaller; and that in prestressed concrete members, the tensile stress in the extreme fibres of the concrete may be permitted so as not to exceed two-thirds of the modulus of rupture of concrete.
5.3.3.5.2 Increase in allowable pressure in soils
When earthquake forces are included, the allowable bearing pressure in soils shall be increased as per Table 1, depending upon type of foundation of the structure and the type of soil.
In soil deposits consisting of submerged loose sands and soils falling under classification SP with standard penetration N values less than 15 in seismic Zones III, IV, V and less than 10 in seismic Zone II, the vibration caused by earthquake may cause liquefaction or excessive total and differential settlements. Such sites should preferably be avoided
while locating new settlements or important projects. Otherwise, this aspect of the problem needs to be investigated and appropriate methods of compaction or stabilization adopted to achieve suitable N values as indicated in Note 3 under Table 30. Alternatively, deep pile foundation may be provided and taken to depths well into the layer which is not likely to liquefy. Marine clays and other sensitive clays are also known to liquefy due to collapse of soil structure and will need special treatment according to site condition.
NOTE — Specialist literature may be referred for determining liquefaction potential of a site.
Table 30 Percentage of Permissible Increase in Allowable Bearing Pressure or Resistance of Soils(Clause 5.3.3.5.2)
Sl No.
Foundation
Type of Soil Mainly Constituting the Foundation
Type I Rock or Hard Soil:Well graded gravel and sand gravel mixtures with or without clay binder, and clayey sands poorly graded or sand clay mixtures (GB, CW, SB, SW and SC) ¹⁾ having ²⁾ above 30, where N is the standard penetration value
Type II Medium SoilsAll soils with N between 10 an 30, and poorly graded sands or gravelly sands with little or no fines (SP ¹⁾ ) with N>15
Type III Soft Soils: All soils other than SP ¹⁾ with N<10
(1)
(2)
(3)
(4)
(5)
i)
Piles passing through any soil but resting on solid type I
50
50
50
ii)
Piles not covered under item (i)
—
25
25
iii)
Raft foundations
50
50
50
iv)
Combined isolated RCC footing with tie beams
50
25
—
v)
Isolated RCC footing without tie beams, or unreinforced strip foundations
50
25
—
vi)
Well foundations
50
25
25
NOTES1 The allowable bearing pressure shall be determined in accordance with good practice [6-1(6)].2 If any increase in bearing pressure has already been permitted for forces other than seismic forces, the total increase in allowable bearing pressure when seismic force is also included shall not exceed the limits specified above.3 Desirable minimum field values of N — If soils of smaller N-values are met, compacting may be adopted to achieve these values or deep pile foundations going to stronger strata should be used.4 The values of N (corrected values) are at the founding level and the allowable bearing pressure shall be determined in accordance with good practice [6-1(6)].
Seismic Zone Level m
Depth Below Ground
N-Values
Remark
III, IV and V
≤5
15
For values of depths between 5 m and 10 m, linear interpolation is recommended.
≥10
25
II (for important structures only)
≤5
15
≥10
20
5 The piles should be designed for lateral loads neglecting lateral resistance of soil layers liable to liquefy.6 Accepted standard [6-1(7)] and good practice [6-1(8)] may also be referred.7 Isolated R.C.C. footing without tie beams, or unreinforced strip foundation shall not be permitted in soft soils with N<10.
See accepted standard [6-1(7)].
See good practice [6-1(8)].
a
Provided that for any structure with T ≥ 0 . 1 sec, the value of A h will not be less than Z/2 whatever be the value of I/R
where
Z = Zone factor given in Table 31, is for the maximum considered earthquake (MCE) and service life of structure in a zone. The factor 2 in the denominator of > is used so as to reduce the maximum considered earthquake (MCE) zone factor to the factor for design basis earthquake (DBE).
Zone factor for some important towns are given at Annex J.
I = Importance factor, depending upon the functional use of the structures, characterised by hazardous consequences of its failure, post-earthquake functional needs, historical value, or economic importance (Table 35).
R = Response reduction factor, depending on the perceived seismic damage performance of the structure, characterized by ductile or brittle deformations. However, the ratio (I/R) shall not be greater than 1.0 (Table 36). The values of R for buildings are given in Table 36.
S /g = Average response acceleration coefficient for rock or soil sites as given by Fig. 12 and Table 32 based on appropriate natural periods and damping of the structure. These curves represent free field ground motion.
NOTE — For various types of structures, the values of Importance Factor I, Response Reduction Factor R, and damping values are given in the respective parts of this standard. The method (empirical or otherwise) to calculate the natural periods of the structure to be adopted for evaluating S /g is also given in the respective parts of this Code.
Table 31Zone Factor, Z
Seismic Zone
II
III
IV
V
Seismic Intensity
Low
Moderate
Severe
Very Severe
Z
0.10
0.16
0.24
0.36
5.3.4.3 Where a number of modes are to be considered
for dynamic analysis, the value of A h as defined in 5.3.4.2 for each mode shall be determined using the natural period of vibration of that mode.
5.3.4.4 For underground structures and foundations at depths of 30 m or below, the design horizontal acceleration spectrum value shall be taken as half the value obtained from 5.3.4.2. For structures and foundations placed between the ground level and 30 m depth, the design horizontal acceleration spectrum value shall be linearly interpolated between A h and 0 . 5 A h , where A h is as specified in 5.3.4.2.
5.3.4.5 The design acceleration spectrum for vertical motions, when required, may be taken as two-thirds of the design horizontal acceleration spectrum specified in 5.3.4.2.
Figure 12 shows the proposed 5 percent spectra for rocky and soils sites and Table 32 gives the multiplying factors for obtaining spectral values for various other dampings.
For Rocky, or hard soil sites
gSa
For Medium soil sites
gSa
For Soft soil sites
gSa
Table 32Multiplying Factors for Obtaining Values for Other Damping
(Clause 5.3.4.2)
Damping percent
0
2
5
7
10
15
20
25
30
Factors
3.20
1.40
1.00
0.90
0.80
0.70
0.60
0.55
0.50
5.3.4.6 In case design spectrum is specifically prepared for a structure at a particular project site, the same may be used for design at the discretion of the project authorities.