7.0 Special features of design and construction for earthquake resistant masonry buildings are given in 7.2 to 7.8.2. Reference may also be made to good practice [6-4(6)] for detailed information.
7.1 Categories of Buildings
For the purpose of specifying the earthquake resistant features in masonry and wooden buildings, the buildings have been categorized in five categories A to E based on the seismic zone and the importance of building I,
where
I = Importance factor applicable to the building (see Table 35 of Part 6, Section 1)
7.1.1 The building categories are given in Table 12.
| Importance Factor | Seismic Zone | |||
| II(1) | III(2) | IV(3) | V(4) | |
| 1.0 | A | B | C | D |
| 1.5 | B | C | D | E |
7.2 Masonry Units
Bricks/Blocks as per the accepted standards [6-4(1)] having a crushing strength not less than 3.5 MPa shall be used. However, higher strength of masonry units may be required depending upon number of storeys and thickness of walls in accordance with provisions of this Section.