The regulations given below are applicable to fuel stations with or without auto service stations.
48.1 Permission from Government of India, Petroleum Ministry and Chief Controller of Explosives shall be necessary
48.2 NOC from Public Works Department and other related departments shall be obtained as per the prevailing rules. As regards service road / building line / control line, the Government Resolution, Public Works Department, No. RBD-1081/ 871/Raste-7, dated 09 March 2001 and the circulars issued in this regard from time to time shall be observed. Instructions contained in Government of India, Ministry of Road Transport and Highways letters dated 25/09/2003 and 17/10/2003 and its enclosures as amended from time to time shall be observed
48.3 Plot shall be located /fronting on National Highway, State Highway, Major District Road, Other District Road or Village Road or other road with a minimum width of 12.00 m. or more
48.4 The plot on which a petrol filling station with or without service bays is proposed shall be an independent plot on which no other structure shall be constructed
48.5 Petrol/LPG/CNG station shall not be permitted within a distance of 90 meter from junction of roads having minimum width of 12 m. each. Also Petrol station shall not be sited within a distance of 90 m. from the nearest premises of school, hospital and theatre, place of assembly or stadium
48.6 Location
To assure satisfactory weaving distances, location of fuel filling stations shall be as per below:
a) The minimum distance of the plot edge from the nearest road junction/ traffic circle/ traffic island/ bridge/ railway level crossing shall be 90m;
b) Fuel filling stations shall not be located opposite a break or opening in the central verge on a dual carriage road;
c) In cases where a service road or a marginal access road is provided in addition to a main road, access to the fuel station shall be provided from the service road. Even with the presence of a service road, a fuel station shall not be located without fulfilling conditions ‘a’ to ‘c’ above.
d) Fuel filling station shall not be sited on the convex side of a road curve. In case the curve is not very sharp and cars moving out of the station are completely visible to the traffic from a distance of at least 90m and vice versa, they may be permitted on such a convex curve.
e) Fuel filling stations shall not be sited within a distance of 90m from the nearest gate of a school, hospital, theatre, place of assembly or stadium.
f) The plot on which a petrol filling station with or without service bays is proposed shall be an independent plot on which no other structure shall be constructed, except ancillary structures as mentioned in regulation 48.9.
48.7 Plot Sizes
The minimum size of plots for fuel filling stations shall be as given below:
a) Fuel filling station: Plot area 545sqm (with minimum frontage of 16.75m)
b) Fuel filling cum service station: Plot area 1100sqm (with minimum frontage of 30.5m)
48.8 Curb Cuts and Driveways
Plots for fuel filling stations shall have only one single curb cut (and driveway) for incoming and outgoing vehicles, not exceeding 10m in width.
Permission for two curb cuts may be granted by the Authority on the condition that they shall be spaced minimum 40m centre to centre. In such cases, the minimum width of each driveway shall be 5m.
48.9 Ancillary Commercial Uses
Ancillary commercial uses shall be permitted within plots for fuel filling stations, provided the location and access for such ancillary commercial uses does not impede or interfere with vehicular circulation to and from the fuel pumps. The built-up area covered under the combination of all such uses shall be limited to 30 percent of the consumable FSI of the plot.
Such uses shall be limited to the following:
a) restaurant or coffee shop up to 60sqm;
b) book shop up to 60sqm;
c) small scale retail for food items up to 60sqm;
d) sale of small motor parts up to 60sqm and
e) ATMs (automated teller machine) up to 10sqm.
48.10 Fire Safety Requirements
Fuel filling stations present fire hazards due to storage of explosive material and nature of their operations. Therefore, in addition to the Maharashtra Fire Prevention and Life Safety Measures Act 2006, fuel filling stations shall comply with the Explosives (Temporary Provisions) Act, 1947, as amended from time to time. The storage and handling of fuel should be in conformity with the restrictions and safety standards under the said Act which regulates operations of inflammable substances like loading, unloading, handling, storage and conveyance etc.
49 REGULATIONS FOR INFORMATION TECHNOLOGY ESTABLISHMENTS
49.1 Not with standing anything contained in these regulations, following regulations shall apply to the building to be used for information technology establishment.
-
Definition -Information Technology Establishment (ITE) means an establishment which is in the business of developing either software or hardware.
-
Height of the room for ITE: Any telemetric equipment storage erection facility can have a height as required for effective functioning of that system.
-
Any covered antenna/ dish antenna/ communication tower will be allowed to be erected free of FSI if, it is used for telecom (basic cellular or satellite telephone) or ITE purpose which shall include equipment relating to earth station, V-sat, routes transponders and similar ITE related structures or equipment.
-
ITE (pertaining software only) may be permitted in R1 zone on the plots / premises fronting on roads having width 9m and above.
-
ITE shall be permitted in service industries zone and industrial zone on all roads having width more than 12m.
-
ITE (pertaining to software only) with ancillary residential development shall be allowed in no development zone subject to the following conditions:
i) The total FSI shall not exceed 0.5.
ii) Residential development shall not have FSI of more than 0.15.
iii) Construction of ITE /Ancillary residential use may be permitted (in suitable location so as to keep as much as remaining space open) upto 15% on 50% of the area of plot. On remaining 50% plot, trees shall be planted at the rate of 500 trees per hectare.
iv) Subdivision of land shall be permitted with the area of plot to be subdivided being not less than 400sqm.
50 REGULATIONS FOR RESORTS AND AMUSEMENT/ THEME PARKS
50.1 These Regulations shall apply to all resorts and amusement parks/ theme park developments undertaken within the Nagpur Metropolitan Area.
50.2 The entire land shall vest in single ownership. It shall not be sub-divided at any time and the individual structures of buildings shall not be sold to different persons.