There should be at least one water tap and arrangement for drainage in the vicinity of each water-closet or group of water-closets in all the buildings.
Each family dwelling unit on premises (abutting on a sewer or with a private sewage disposal system) shall have, at least, one water-closet and one kitchen type sink. A bath or shower shall also be installed to meet the basic requirement of sanitation and personal hygiene.
All other structures for human occupancy or use on premises, abutting on a sewer or with a private sewage disposal system, shall have adequate sanitary facilities, but in no case less than one watercloset and one other fixture for cleaning purposes.
31.2For Residences
Dwelling with individual convenience shall have at least the following fitments:
a) One bathroom provided with a tap and a floor trap,
One water-closet with flushing apparatus with an ablution tap; and One tap with a floor trap or a sink in kitchen or wash place.
Dwelling without individual conveniences shall have the following fitments:
a) One water tap with floor trap in each tenement,
b) One water-closet with flushing apparatus and one ablution tap,
c) Bath for every two tenements, and
d) One bath with water tap and floor trap for every two tenements.
Table No- 17a: Sanitation Requirements for Residences
Sr
Fitments
Dwellings with Individual Conveniences
Dwellings without Individual Conveniences
1
Bath Room
1 Provided with water tap
1 for every two tenements
2
Water-Closet
1 Provided with water tap
1 for every two tenements
3
Sink (Nahani)
1 Provided with water tap
------
4
Water Tap
------
1 with draining arrangements in each tenement 1 in common bathrooms and common water- closets
Note: Where only one water closet is provided in a dwelling, the bath and the water closet shall be separately accommodated.
31.3Drainage and Sanitation for Buildings Other than Residences
The requirements for fitments for drainage and sanitation in the case of buildings other than residences shall be in accordance with Table No. 18 to Table No. 31. The following shall be, in addition, taken into consideration:
a) The figures shown are based upon one (1) fixture being the minimum required for the number of persons indicated or part thereof
b) Building categories not included in the tables shall be considered separately by the Chairman- NIT.
c) Drinking fountains shall not be installed in the toilets.
d) Where there is the danger of exposure to skin contamination with poisonous, infectious or irritating material, washbasin with eye wash jet and an emergency shower located in an area accessible at all times with the passage / right of way suitable for access to a wheel chair, shall be provided.
e) When applying the provision of these tables for providing the number of fixtures, consideration shall be given to the accessibility of the fixtures.
f) Using purely numerical basis may not result in an installation suited to the need of a specific building. For example, schools should be provided with toilet facilities on each floor. Similarly toilet facilities shall be provided for temporary workmen employed in any establishment according to the needs; and in any case one WC and one washbasin shall be provided.
g) All buildings used for human habitation for dwelling work, occupation, medical care or any purpose detailed in the various tables, abutting a public sewer or a private sewage disposal system, shall be provided with minimum sanitary facilities as per the schedule in the tables. In case the disposal facilities are not available, they shall be provided as a part of the building design for ensuring high standards of sanitary conditions in accordance with this section.
h) Workplaces where crèches are provided, they shall be provided with one WC for 10 persons or part thereof, one washbasin for 15 persons or part thereof, one kitchen sink with floor tap for preparing food / milk preparations. The sink provided shall be with a drinking water tap.
i) In all types of buildings, individual toilets and pantry should be provided for executives and for meeting / seminar / conference rooms, etc. as per the user requirement.
j) Where food is consumed indoors, water stations may be provided in place of drinking water fountains.
Table No- 18: Sanitation Requirements for office
Sr.
Fixtures
Public Toilets
Staff Toilets
Male
Female
Male
Female
1
2
3
4
5
6
i)
Executive Rooms and Conference Halls in
Unit could be common for
For individual officer
ii)
Main Office Toilets for Staff and Visitors
1 per 25
1 per 15
1 per 25
1 per 15
a) Water-closet
1 per 25
1 per 15
1 per 25
1 per 15
b) Ablution tap with each water closet
1 in each water-closet
c) Urinals
Nil up to 6
-
Nil up to 6
-
101-200
Over 200
d) Washbasins
1 per 25
1 per 25
1 per 25
1 per 25
e) Drinking water fountain
1 per 100
1 per 100
1 per 100
1 per 100
f) Cleaner's sink
1 per floor
Table No- 19: Sanitation Requirements for Factories
Sr.
Fixtures
Offices / Visitors
Workers
Male
Female
Male
Female
1
2
3
4
5
6
i)
Water closets (workers & staff) For persons 101-200 add For persons over 200 add
1 for upto 25 2 for 16-35 3 for 36-65 4 for 66-1003%2.5%
1 for upto 15 2 for 16-25 3 for 26-40 4 for 41-57 5 for 58-77 6 for 78-1005%4%
1 for upto 25 2 for 16-35 3 for 36-65 4 for 66-1003%2.5%
1 for upto 15 2 for 16-25 3 for 26-40 4 for 41-57 5 for 58-77 6 for 78-1005%4%
ii)
Ablution tap
1 in each water closet
1 in each water closet
1 in each water closet
1 in each water closet
iii)
Urinals For persons 101-200 add For persons over 200 add
Nil upto 6 1 for 7-20 2 for 21-45 3 for 46-70 4 for 71-1003%2.5%
-
Nil upto 6 1 for 7-20 2 for 21-45 3 for 46-70 4 for 71-1003%2.5%
iv)
Washbasins Washbasins in rows or troughs and taps spaced 750 mm c/c
1 per 25 or part thereof
1 per 25 or part thereof
1 per 25 or part thereof
1 per 25 or part thereof
v)
Drinking water fountain
1 per every 100 or part thereof with minimum one on each floor
1 per every 100 or part thereof with minimum one on each floor
vi)
Cleaner's sink
1 on each floor
1 on each floor
1 on each floor
1 on each floor
vii)
Showers / Bathing rooms
As per trade requirements
As per trade requirements
viii)
Emergency shower and eye wash fountain
-
-
1 per every shop floor per 500 persons
NOTE – For factories requiring workers to be engaged in dirty and dangerous operations or requiring them to being extremely clean and sanitized conditions additional and separate (if required so) toilet facilities and if required by applicable Industrial and Safety Laws and the Factories Act must be provided in consultation with the user.
Table No- 20: Sanitation Requirements for Cinema, Multiplex, Concert and Convention Halls, Auditorium
Sr.
Fixtures
Offices / Visitors
Workers
Male
Female
Male
Female
1
2
3
4
5
6
i)
Water closets
1 per 100 up to400Over 400, add at 1 per 250 or part thereof
3 per 100 up to200Over 200, add at 2 per 100 or part thereof
1 for up to 15
1 for up to 12
ii)
Ablution tap
1 in each water closet
1 in each water closet
1 in each water closet
1 in each water closet
iii)
Urinals
1 per 25 or part thereof
-
Nil up to 6 1 for 7-20 2 for 21-45
-
iv)
Washbasins
1 per 200 or part thereof
1 for up to 15 2 for 16-35
1 for up to 12 2 for 13-25
v)
Drinking water fountain
1 per 100 persons or part thereof
vi)
Cleaner's sink
1 per floor
vii)
Showers / Bathing rooms
As per trade requirements
Note:
i) Some WC’s may be European style if desired.
ii) Male population may be assumed as two-third and female population as one-third
Table No- 21: Sanitation Requirements for Art Galleries, Libraries and Museums
Sr.
Fixtures
Public
Public
Staff
Staff
Sr.
Fixtures
Male
Female
Male
Female
1
2
3
4
5
6
i)
Water closets
1 per 200 up to400Over 400, add at 1 per 250 or part thereof
1 per 100 up to200Over 200, add at 2 per 150 or part thereof
1 for up to 15 2 for 16-35
1 for up to 12 2 for 13-25
ii)
Ablution tap
1 in each water closet
1 in each water closet
1 in each water closet
1 in each water closet
ii)
Ablution tap
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
iii)
Urinals
1 per 50
-
Nil up to 6 1 for 7-20 2 for 21-45
-
iv)
Washbasins
1 per 200 or part thereof. For over 400, add at 1 per 250 persons or part thereof
1 for every 200 or part thereof. For over 200, add at 1 per 150 persons or part thereof
1 for up to 15 2 for 16-35
1 for up to 12 2 for 13-25
v)
Drinking water fountain
1 per 100 persons or part thereof
1 per 100 persons or part thereof
1 per 100 persons or part thereof
1 per 100 persons or part thereof
vi)
Cleaner's sink
1 per floor, minimum
1 per floor, minimum
1 per floor, minimum
1 per floor, minimum
vii)
Showers / Bathing rooms
As per trade requirements
As per trade requirements
As per trade requirements
As per trade requirements
NOTE:
i) Some WC’s may be European style if desired.
ii) Male population may be assumed as two-third and female population as one-third
Table No- 22: Sanitation Requirements for Hospitals with Indoor Patient Wards
Sr.
Fixtures
Patient Toilets
Staff Toilets
Male
Female
Male
Female
1
2
3
4
5
6
i)
Toilet suite comprising one WC and one washbasin and shower stall
Private room with upto 4 patients
For individual doctor's / officer's rooms
For General Wards, Hospital Staff and Visitors
ii)
Water closets
1 per 8 beds or part thereof
1 per 8 beds or part thereof
1 for up to 15 2 for 16-35
1 for up to 12 2 for 13-25
iii)
Ablution tap
1 in each water closet
1 in each water closet
1 in each water closet
1 in each water closet
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
iv)
Urinals
1 per 30 beds
-
Nil up to 6 1 for 7-20 2 for 21-45
-
v)
Washbasins
2 per 30 beds or part thereof. Add 1 per additional 30 beds or part thereof.
1 for up to 15 2 for 16-35
1 for up to 12 2 for 13-25
vi)
Drinking water fountain
1 per ward
1 per 100 persons or part thereof
vii)
Cleaner's sink
1 per ward
-
viii)
Showers / Bathing rooms
1 per ward
-
ix)
Kitchen sink
1 per ward
-
NOTE:
i) Some WC’s may be European style if desired.
ii) Male population may be assumed as two-third and female population as one-third
iii) Provision for additional and special hospital fittings where required shall be made
Table No- 23: Sanitation Requirements for Hospitals with Outdoor Patient Department
Sr.
Fixtures
Patient Toilets
Staff Toilets
Male
Female
Male
Female
1
2
3
4
5
6
i)
Toilet suite comprising one WC and one washbasin (with optional shower stall if building used for 24 hrs)
For up to 4 patients
For individual doctor's / officer's rooms
ii)
Water closets
1 per 100 persons or part thereof
2 per 100 persons or part thereof
1 for up to 15 2 for 16-35
1 for up to 12 2 for 13-25
iii)
Ablution tap
1 in each water closet
1 in each water closet
1 in each water closet
1 in each water closet
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
iv)
Urinals
1 per 50 persons or part thereof
-
Nil up to 6 1 per 7-20 2 per 21-45
-
v)
Washbasins
1 per 100 persons or part thereof
2 per 100 persons or part thereof
1 for up to 15 2 for 16-35
1 for up to 12 2 for 13-25
vi)
Drinking water fountain
1 per 500 persons or part thereof
1 per 100 persons or part thereof
NOTE:
i) Some WC’s may be European style if desired.
ii) Male population may be assumed as two-third and female population as one-third
iii) Provision for additional and special hospital fittings where required shall be made
Table No- 24: Sanitation Requirements for Hospital’s Administrative Buildings
Sr.
Fixtures
Staff Toilets
Staff Toilets
Sr.
Fixtures
Male
Female
1
2
3
4
i)
Toilet suite comprising one WC and one washbasin (with optional shower stall if building used for 24 hrs)
For individual doctor's/officer's rooms
For individual doctor's/officer's rooms
ii)
Water-closets
1per 25 persons or part thereof
1per 15 persons or part thereof
iii)
Ablution tap
One in each water- closet
One in each water- closet
iii)
Ablution tap
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals
iv)
Urinals
Nil up to 6 1 per 7 to 20 2 per 21-45
-
v)
Washbasins
1per 25 persons or part thereof
1per 25 persons or part thereof
Sr.
Fixtures
Staff Toilets
Staff Toilets
Sr.
Fixtures
Male
Female
vi)
Drinking water fountain
1 per 100 persons or part thereof
1 per 100 persons or part thereof
vii)
Cleaner's sink
1 per floor, Min
1 per floor, Min
viii)
Kitchen sink
1 per floor, Min
1 per floor, Min
NOTE: Some WC’s may be European style if desired.
Table No- 25: Sanitation Requirements for Hospital’s Staff Quarters and Nurses Homes
Sr.
Fixtures
Staff Quarters
Nurses Homes
Male
Female
Male
Female
1
2
3
4
5
6
i)
Water-closets
1 per 4 persons or part thereof
1 per 4 persons or part thereof
1 per 4 persons or part thereof 2 for 16-35
1per 4 persons or part thereof 2 for 16-35
ii)
Ablution tap
One in each water closet
One in each water closet
One in each water closet
One in each water closet
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals
iii)
Washbasins
1 per 8 persons or part thereof
1 per 8 persons or part thereof
iv)
Bath (Showers)
1 per 4 persons or part thereof
1 per 4 persons or part thereof
v)
Drinking water fountain
1 per 100 persons or part thereof, minimum 1 per floor
1 per 100 persons or part thereof, minimum 1 per floor
vi)
Cleaner's sink
1 per Floor
1 per Floor
NOTE:
i) Some WC’s may be European style if desired.
ii) For independent housing units fixtures shall be provided as for residences
iii) Provision for additional and special fittings where required shall be made
Table No- 26: Sanitation Requirements for Hotels
Sr.
Fixtures
Public Rooms
Public Rooms
Non-Residential Staff
Non-Residential Staff
Sr.
Fixtures
Male
Female
Male
Female
(1)
(2)
(3)
(4)
(5)
(6)
i)
Toilet suite comprising one WC and one washbasin with shower or a bath tub
Individual guest rooms with attached toilets
Individual guest rooms with attached toilets
-
-
Guest Rooms with Common Facilities
Guest Rooms with Common Facilities
Guest Rooms with Common Facilities
Guest Rooms with Common Facilities
Guest Rooms with Common Facilities
Guest Rooms with Common Facilities
ii)
Water closets
1 per 100 persons up to400Over 400 add at 1 per 250 or part thereof
2 per 100 persons up to200Over 200 add at 1 per 100 or part thereof
1 for up to 15 2 for 16-35 3 for 36-65 4 for 66-100
1 for up to 12 2 for 13-25 3 for 26-40 4 for 41-57 5 for 58-77 6 for 78-100
Sr.
Fixtures
Public Rooms
Public Rooms
Non-Residential Staff
Non-Residential Staff
Sr.
Fixtures
Male
Female
Male
Female
(1)
(2)
(3)
(4)
(5)
(6)
iii)
Ablution tap
1 in each water closet
1 in each water closet
1 in each water closet
1 in each water closet
iii)
Ablution tap
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
iv)
Urinals
1 per 50 persons or part thereof
-
Nil up to 6 1 for 7-20 2 for 21-45 3 for 46-70 4 for 71-100
-
v)
Washbasins
1 per WC / Urinal
1 per WC
ii) Male population may be assumed as two-third and female population as one-third
iii) Provision for additional and special fittings where required shall be made
Table No- 27: Sanitation Requirements for Restaurants
Sr.
Fixtures
Public Rooms
Public Rooms
Non-Residential Staff
Non-Residential Staff
Sr.
Fixtures
Male
Female
Male
Female
1
2
3
4
5
6
i)
Water closets
1 per 50 seats up to 200 Over 200 add at 1 per 100 or part thereof
2 per 50 seats up to 200 Over 200 add at 1 per 100 or part thereof
1 for up to 15 2 for 16-35 3 for 36-65 4 for 66-100
1 for up to 12 2 for 13-25 3 for 26-40 4 for 41-57 5 for 58-77 6 for 78-100
ii)
Ablution tap
1 in each water closet
1 in each water closet
1 in each water closet
1 in each water closet
ii)
Ablution tap
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water closets and urinals
Sr.
Fixtures
Public Rooms
Public Rooms
Non-Residential Staff
Non-Residential Staff
Sr.
Fixtures
Male
Female
Male
Female
1
2
3
4
5
6
iii)
Urinals
1 per 50 persons or part thereof
-
Nil up to 6 1 for 7-20 2 for 21-45 3 for 46-70 4 for 71-100
-
iv)
Washbasins
1 per WC
1 per WC
1 per WC
1 per WC
v)
Cleaner's sink
1 per restaurant
1 per restaurant
1 per restaurant
1 per restaurant
vi)
Kitchen sink / Dish washer
1 per kitchen
1 per kitchen
1 per kitchen
1 per kitchen
NOTE:
i) Some WC’s may be European style if desired.
ii) Male population may be assumed as two-third and female population as one-third
iii) Provision for additional and special fittings where required shall be made
Table No- 28: Sanitation arrangements for Schools and Educational Institutions
Sr.
Fixtures
Nursery School
Non-Residential
Residential
Boys
Girls
Boys
Girls
1
2
3
4
5
6
7
i)
Water- closets
1 per 15 pupils or part thereof
1 for 40 pupils or part thereof
1 per 25 pupils or part thereof
1 per 8 pupils or part thereof
1 per 6 pupils or part thereof
ii)
Ablution tap
One in each water- closet
One in each water-
One in each water-
One in each water- closet
One in each water- closet
One in each water- closet
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals.
iii)
Urinals
----
1 per 20 pupils or part thereof
----
1 per 25 pupils or part thereof
----
iv)
Washbasins
1 per 15 pupils or part thereof
1 per 60 pupils or part thereof
1 per 40 pupils or part thereof
1 per 8 pupils or part thereof
1 per 6 pupils or part thereof
v)
Bath / Showers
1 per 40 pupils or part thereof
----
----
1 per 8 pupils or part thereof
1 per 6 pupils or part thereof
vi)
Drinking water fountain or taps
1 per 50 pupils or part thereof
1 per 50 pupils or part thereof
1 per 50 pupils or part thereof
1 per 50 pupils or part thereof
1 per 50 pupils or part thereof
vi)
Cleaner's Sink
1 per floor
NOTE:
i) Some WC’s may be European style if desired.
ii) For teaching staff, the schedule of fixtures to be provided shall be the same as in case of office building.
Table No- 29: Sanitation arrangements for Hostels
Sr.
Fixtures
Resident
Non-Resident
Visitor / Common Rooms
Male
Female
Male
Female
Male
Female
1
2
3
4
5
6
7
8
i)
Water-closets
1 per 6 or part thereof
1 per 6 or part thereof
1 for up to 152 for 16-353 for 36-654 for 66-100
1 for up to 122 for 13-253 for 26-404 for 41-575 for 58-776 for 78-100
1 per 100 up to 400Over 400 add at 1 per 250
1 per 200 up to 200Over 200 add at 1 per 100
ii)
Ablution tap
One in each water- closet
One in each water- closet
One in each water- closet
One in each water- closet
One in each water- closet
One in each water- closet
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals.
iii)
Urinals
1 per 25 or part thereof
-
Nil up to 61 for 7-202 for 21-453 for 46-704 for 71-100
-
1 per 50 or part thereof
-
iv)
Wash basins
1 per 8 persons or part thereof
1 per 6 persons or part thereof
-
-
-
-
v)
Bath / Showers
1 per 8 persons or part thereof
1 per 6 persons or part thereof
-
-
-
-
NOTE:
i) Some WC’s may be European style if desired.
Table No- 30: Sanitation arrangements for Fruit and Vegetable Markets
Sr.
Fixtures
Shop Owners
Shop Owners
Common Toilets in Market Building
Common Toilets in Market Building
Public Toilet for Floating Population
Public Toilet for Floating Population
Sr.
Fixtures
Male
Female
Male
Female
Male
Female
1
2
3
4
5
6
7
8
i)
Water-closets
1 per 8 persons or part thereof
1 per 8 persons or part thereof
1 for up to 15 2 for 16-35 3 for 36-65 4 for 66-100
1 for up to 12 2 for 13-25 3 for 26-40 4 for 41-57 5 for 58-77 6 for 78-100
1 per 50 (Minimum 2)
1 per 50 (Minimum 2)
ii)
Ablution tap
One in each water- closet
One in each water- closet
One in each water- closet
One in each water- closet
One in each water- closet
One in each water- closet
ii)
Ablution tap
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals.
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals.
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals.
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals.
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals.
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals.
iii)
Urinals
-
-
Nil up to 6 1 for 7-20 2 for 21-45 3 for 46-70 4 for 71-100
-
1 per 50
-
Sr.
Fixtures
Shop Owners
Shop Owners
Common Toilets in Market Building
Common Toilets in Market Building
Public Toilet for Floating Population
Public Toilet for Floating Population
Sr.
Fixtures
Male
Female
Male
Female
Male
Female
1
2
3
NOTE :
i) Toilet facilities for individual buildings in a market should be taken same as that for office building
ii) Common toilets in the market buildings provide facilities for persons working in shops and their regular visitors
iii) Special toilet facilities for a large floating population of out of town buyers / sellers, labour, drivers of vehicles for whom special toilet (public toilets).
Table No- 31: Sanitation Arrangements for Airports and Railway Stations
Sr.
Fixtures
Junction Stations, Intermediate Stations and Bus Stations
Terminal Railway and Bus Stations
Domestic and International Airports
Male
Female
Male
Female
Male
Female
1
2
3
4
5
6
7
8
i)
Water-closet
3 for up to 1000 Add 1 per additional 1000 or part thereof
4 for up to 1000 Add 1 per additional 1000 or part thereof
4 for up to 1000 Add 1 per additional 1000 or part thereof
5 for up to 1000 Add 1 per additional 1000 or part thereof
Minimum 2 For 200 2 For 400 9 For 600 12 For 800 16 For 1000 18
Minimum 2 For 200 2 For 400 9 For 600 12 For 800 16 For 1000 18
ii)
Ablution tap
One in each water- closet
One in each water-closet
One in each water-closet
One in each water-closet
One in each water- closet
One in each water- closet
1 water tap with draining arrangements shall be provided for every 50 persons or part thereof in the vicinity of water-closets and urinals.
iii)
Urinals
4 for up to 1000 Add 1 per additional1000
-
6 for up to 1000 Add 1 per additional1000
-
1 per 40 or part thereof
-
iv)
Washbasins
1 per WC / Urinal
1 per WC
1 per WC / Urinal
1 per WC
1 per WC / Urinal
1 per WC
v)
Bath/Showers
2 per 1000
3 per 1000
4 per 1000
Sr.
Fixtures
Junction Stations, Intermediate Stations and Bus Stations
Terminal Railway and Bus Stations
Domestic and International Airports
Male
Female
Male
Female
Male
Female
1
2
3
4
5
6
7
8
vi)
Drinking fountain or taps water (in common lobby for male/ female)
2 per 1000 or part thereof
3 per 1000 or part thereof
4 per 1000 or part thereof
vii)
Cleaner's sink
1 per toilet compart ment with 3 WC's
1 per toilet compart ment with 3 WC's
1 per toilet compart ment with 3 WC's
1 per toilet compartment with 3 WC's
1 per toilet compar tment with 3 WC's
1 per toilet compartm ent with 3 WC's
viii)
Toilet for Disabled
1 per4000
1 per4000
1 per4000
1 per 4000
1 per 4000 (Minimum 1)
1 per 4000 (Minimum 1)
NOTE:
i) Some WC’s may be European style if desired
ii) Male population may be assumed as three-fifth and female population as two-fifth
iii) Separate provision shall be made for staff and workers
1 for up to 15 2 for 16-35 3 for 36-65 4 for 66-100
1 for up to 12 2 for 13-25 3 for 26-40 4 for 41-57
vi)
Bath (Showers)
1 per 10 persons or part thereof
1 per 10 persons or part thereof
-
-
vii)
Cleaner's sink
1 per 30 rooms, minimum 1 per floor
1 per 30 rooms, minimum 1 per floor
1 per 30 rooms, minimum 1 per floor
1 per 30 rooms, minimum 1 per floor
viii)
Kitchen sink
1 per kitchen
1 per kitchen
1 per kitchen
1 per kitchen
NOTE:
i) Some WC’s may be European style if desired.
4
5
6
7
8
iv)
Wash basins
1 per 8 persons or part thereof
1 per 8 persons or part thereof
1 for up to 15 2 for 16-35 3 for 36-65 4 for 66-100
1 for up to 12 2 for 13-25 3 for 26-40 4 for 41-57