The widths of pathways shall be as follows -
a) 1.5 m. width of pathways upto 20 m. in length;
b) 2.0 m. width for pathways upto 30 m. in length;
c) 2.5 m. width for pathways upto 40 m. in length;
d) 3.0 m. width for pathways upto 50 m. in length
Flushing cistern - In water closets, flushing cistern shall not be essential and toilets without this provision may be permitted
Water closet pan size - The water closet seat shall be of a minimum of 0.46 m. (18 inches) in length.
24.4.9.9 Septic tank and leaching pits (soak pits.-A septic tank shall be provided with capacity of 141.6 litres (five cubic feet) per capita. Where the municipal services are likely to be available within four to five years or so, pour flush water seal latrines (NEERI type) shall be permitted where the municipal sewerage system is not available and the water table in the area is not high.
Convenience shopping - Convenience Shopping as defined in these Regulations shall be permitted along layout roads with width of 12.2 m. to 18.49 m. provided that a minimum set-back of 1.5m and a minimum plot area of 25.2 sq.m is available and is provided.
Recreation Ground - In the layouts, provision for recreation ground shall be on the lines prescribed in these Regulations
Ancillary structures - Ancillary structures such as underground tank, overhead tank, substations etc. shall be permissible in the compulsory recreation open space subject to the condition that not more than 10 percent of such space shall be utilised for such purposes.
Other provisions of these regulations shall continue to be applicable for such schemes.