The Residential – R1 zone is primarily intended for the following residential building types:
a) Residential multi-storey apartment;
b) Row house and semi-detached dwellings;
c) Villas/ bungalow;
d) Site and services/ other housing schemes for the EWS;
e) Old-age home or orphanage;
f) Hostels;
g) Service apartments.
Accessory uses permitted
Following accessory uses (non-residential building uses that are complimentary to residential development) will be permitted provided that the total area for all of these either singly or combined does not exceed 50 percent of the permissible built-up area of the plot. Further, setback requirements by type of activity shall be applicable as per tables 13, 13a and 14. In case of two or more activities in a building, greater of the relevant setbacks shall be applicable.
a) Community hall
b) Library
c) Pre-primary school/ crèche/ day care centre on roads not more than 12m wide
d) Places for worship, provided a No Objection Certificate shall be obtained from the concerned Police Authority and Collector before application of building permission. Commercial uses shall
not be permissible to be combined with the religious building. Minimum plot area shall be 300sqm.
e) Customary home occupation (as defined in 2.60) without employing hired labour and including stitching, embroidery, button making, etc., with or without motive power. If motive power is used, the total electricity load should not exceed 1HP.
f) Medical and dental practitioner's dispensary including pathological laboratory, diagnostic clinic, polyclinic, to be permitted on any floor above. However maternity homes and nursing homes, not exceeding 5 beds for inpatients, located on the ground or stilt floor or on first floor, shall be provided with a separate means of access of staircase from within the building or outside. Such means of access shall not be provided within the prescribed marginal open spaces in any case and with the special permission of Chairman, NIT.
g) Professional offices and studies of residents of the premises that are incidental to such residential use, not occupying a floor area exceeding 20sqm per office.
h) Club houses not conducted as a business.
Other permissible uses
a) Convenience shops (as defined in 2.28) not more than 10sqm BUA;
b) Service and repair shops not more than 20sqm BUA;
c) Retail shops and general stores with maximum BUA upto 200sqm
d) Restaurants and cafeteria upto 200sqm BUA;
e) Frozen food lockers and fast food vending stalls;
f) Book depot, stationary and chemist shops;
g) Radio broadcasting stations, studio, telephone exchanges, mobile towers;
h) Storage of furniture and other household goods, not exceeding 500sqm;
i) Dispensaries, including veterinary dispensaries or polyclinics, pathology laboratories;
j) Photographic studios and laboratories with not more than 50sqm, not employing more than 9 persons and not using power more than 3HP;
k) Personal service establishments such as professional offices;
l) Art galleries;
m) Exhibition hall, community hall, welfare centre, gymnasium;
n) Animal pounds;
o) Coal and firewood shops;
p) Small scale service industries or cottage industries not employing more than 9 persons, with motive power not exceeding 5HP and area not more than 50sqm; such as paper box manufacturing including paper cutting, mattress making and cotton cleaning, establishment requiring power for sealing tin;
q) Repair, cleaning shops and analytical, experimental or testing laboratories not employing more than 15 persons in the industrial activity. Such establishments shall not include use of a cleaning or dyeing fluid with a flash point lower than 60 degree Celsius and machines with dry load capacity of 30kg. Establishment which conducts activities that are noxious or offensive because of emission of odour, dust, smoke, gas, noise or vibration or other-wise dangerous to public health and safety may be permitted with special permission of Chairman, NIT provided that the motive power requirement of such establishment does not exceed 10 HP;
r) Repairing garages not employing more than 9 persons and 2HP motive power in the industrial activity with no floor above;
s) Battery charging and repairing, not employing more than 6 persons with an area not more than 25sqm and not more than 2 chargers with power not exceeding 5KW;
t) Trade or other similar schools not involving any danger of fire or explosion nor of offensive noise, vibration, smoke, dust, odour, glare, heat or any objectionable influences;
u) Flour mill/ spice grinding with special written permission of the Chairman, NIT if
i) It is located on ground floor;
ii) Adequate care has been taken in structural design;
iii) It does not cause any nuisance to the neighbors and residents of upper floors;
iv) Power requirement does not exceed 7.5kw, and horsepower upto 5HP may be granted with special permission of Chairman, NIT.
v) Fuel filling stations/ auto service stations
Non-residential uses permitted only in independent plots
a) Maternity homes or nursing homes with more than 5 beds for inpatients within independent buildings with one doctor’s residence with the special written permission of the Chairman who will take into consideration the suitability of the site, size and shape of the site, means of access, water and sanitary arrangement etc, before granting the permission; provided the plot is minimum 500sqm in area and the building has 6m setback on all sides;
b) Public libraries or museums in independent structures restricted to ground floor;
c) Club house or other recreational activity conducted as a business;
d) Hotel, motel or lodge;
e) Primary schools on roads not more than 24m in width and secondary schools, colleges;
f) Public parks;
g) Vegetable and fruit market ;
h) Bus shelters, auto rickshaw/ taxi stands;
i) Fuel stations, subject to conditions as per Regulation 48;
j) Veterinary hospitals;
k) Storage and sale of kerosene not exceeding 1000litres in groceries and approved ration shops on retail basis;
l) Sale/ distribution/ storage of LPG cylinders upto 100kg;
m) Parking of automobiles and other light vehicles as a business;
n) Marriage halls provided they have access from a road of minimum width 18m;
o) Hospitals, sanatoria, institutions for children, the aged, mahila ashram, in independent building, provided such uses take access from a road of minimum width 18m;
p) Public utility buildings.
Special conditions for use premises with shop lines
a) A building or premises with a shop line along a street may be used only for the purposes indicated in 22.2.4 subject to the following conditions:
78
b) It is located on a road with minimum width of 12m;
c) The additional uses permissible here under shall be restricted to a depth of 12.00m measured from the building line and only on the ground floor of the building in the front portion abutting the street;
d) Such additional uses shall in no case consume no more than 30 percent of the permissible FSI except in buildings on independent plots. Notwithstanding anything contained above, a pedestrian shopping precinct extending to a depth of more than 12m may be provided subject to the condition that no shop in such pedestrian precinct shall be allowed to open directly on the road in front. The minimum width of a pedestrian way provided shall be 3m clear of all steps or projections. Bollards shall be placed at the entrance of such a pedestrian passage to prevent entry of vehicles provided further that satisfactory arrangements for natural or artificial ventilation are made as may be directed by the NIT;
e) Where the building or premises abuts on two or more streets, no direct opening of such shop shall be permissible on the street, which is less than 9m in congested and 12m in non-congested area;
f) All goods offered for sale and brought for repair shall be displayed and kept within the building and shall not be kept in the passages or footpaths or roads;
g) No trade and business involving any danger of fire, explosion offensive noise, vibrations, smoke, dust glare heat or other objectionable influence may be allowed.