The maximum depth of a loft shall be 1.5 m. and the loft may be provided, over residential kitchens, habitable rooms, bath rooms, corridors and over shop floor, built up to an area 25 per cent over kitchens and full space of bath rooms, water closets and corridors . In the shops with width upto 3.0m, a loft shall cover upto 33.5 percent of the carpet area and in shops width above 3.0m, a loft shall cover upto 50 percent of the carpet area. However, loft will not be allowed where mezzanine floor is provided.
The clear head room under loft shall not be less than 2.1 m.
Loft in commercial areas and industrial buildings shall be located 2 m. away from the entrance.
Size of ledge or tand
A ledge or tand in a habitable room shall not cover more than 25 percent of the area of the floor on which it is constructed and shall not interfere with the ventilation of the room under any circumstances.
62
Height of ledge or tand
a) The ledge shall be provided at a minimum height of 2.1m.
b) Cantilevered projections of cupboards and shelves may be permitted in the marginal open spaces created by building setbacks subject to the prescribed conditions in Regulation 15.4.1.
17.6 Cupboards & Shelves
The projections (cantilever) of cupboards and shelves may be permitted on all floors except on ground floor. Such projections may project upto 45 cm, in the setbacks for residential buildings provided the width of such cupboard/shelves does not exceed 2.4 m. and each room shall not have more than one such cupboard/ shelf. Moreover such projection shall be at least 2 m. from plot boundary and the bottom of such a projection shall be atleast 2.5 m. above the finished ground level.