12.1 Every plot/ building whether existing or proposed, shall have means of access as required in these Regulations.
12.2 Every person who erects a building shall not at any time erect or cause or permit to erect or re-erect any building which in any way encroaches upon or diminishes the area set apart as means of access.
12.3 Width of Means of Access
A. For Residential Development -The plots shall abut on a public means of access like street / road. Minimum width of access / layout road / internal road in any development proposal / subdivision / group housing shall be as given in Table No- 4. In the interest of general development of an area, the NIT/SPA may require the means of access to be of larger width than that required below.
Table No- 4
| S. No. | Length of Means of access (meters) | Width of Means of access (meters) |
|---|---|---|
| i | Upto 150 | 9.00 |
| ii | Above 150 and up to 300 | 12.00 |
| iii | More than 300 | 15.00 |
B. Other than residential development –The minimum width of access / layout road / internal road in any development proposal in the industrial zone shall be as given in Table No.4a.
Table No- 4a
| S. No. | Length of Means of Access in m. | Width of Means of Access in m. |
|---|---|---|
| i | Upto 75 | 12 |
| i | 75 to 150 | 15 |
| ii | Above 150m | 18 or more |
Note:
i) The means of access shall be clear of required marginal open spaces from the existing building line.
ii) In no case, development on plots shall be permitted unless it is accessible by the authorized public street existing prior to coming in to force of these Regulations or road from the layout sanctioned prior to these Regulations.
Pathways
A pedestrian approach to the buildings from road / street / internal means of access wherever necessary, shall be through paved pathway of width not less than 1.5m., 2.0 and 4.5m provided its length measured from exit way of the building is not more than 20 m, 40 m and 60m respectively from the main / internal means of access. If the length is more than 60 m, then a regular street as provided in Table No.4a shall be necessary. This provision shall also apply to group housing scheme or layout of building for other uses except development under Regulation No 24.4.
The length of means of access shall be determined by the distance from the farthest plot (building) to the public street. The length of the subsidiary access way shall be measured from the point of its origin to the next wider road on which it meets.
In the interest of general development of an area, the Chairman, NIT may require the means of access to be of larger width than that required under regulation No. 12.3.
12.3.1.3 In case where a private passage is unrestrictedly used by public for more than 10 years as a means of access of width not less than 9 m. to a numbers of plots, the Chairman, NIT may take steps including improvement under, the provision of relevant Act to declare it as a public street.
In congested areas and gaothans in the case of plots facing street / means of access less than 4.5 m. in width the plot boundary shall be shifted to be away by 2.25 m. from the central line of the street/ means of access way to give rise to a new street / means of access way of width of 4.5 m. clear from the structural projections.
12.4 Means of access shall be levelled, metalled, flagged, paved, sewered, drained, channelled, lighted, laid with water supply line and provided with trees for shade (wherever necessary) to the satisfaction of the Authority, free of encroachment and shall be maintained in a condition to the satisfaction of the Chairman, NIT.
If any private street or any other means of access to a building is not constructed and maintained as specified above, the authority may by written notice require the owner or owners of the several premises fronting or adjoining the said street or other means of access or abutting thereon or to which access is obtained through such street or other means of access or which shall benefit by works executed to carry out any or more of the aforesaid requirements in such manner and within such time as the NIT/ SPA shall direct. If the owner or owners fail to comply with this direction, the NIT/ SPA may arrange for its execution and recover the expenses incurred from the owner/ owners.
12.5 Access from the Highways/classified roads: Generally the plot / building along Highway and important roads with width (right of way) 30m or more shall derive access from service road. However, highway amenities like petrol pump; hotel etc. may have an access direct from such road categories mentioned above or more. The above shall be subject to the provisions of State Highways Act, 1965 and National Highway Act 1956.
Provided that in suitable cases, the NIT/ SPA may suspend the operation of this rule till service roads are provided.
12.6 For buildings identified in Regulation No. 6.2.6.1, the following additional provisions of means of access for public occupancy buildings shall be ensured;
a) The width of the main street on which the building abuts shall not be less than 12m and one end of this street shall join another street of width not less than 12 m. in width subject to Regulation No.12.3.
b) The approach to the building and open spaces on its all sides (see Regulation No. 15.1 shall be 6 m. and the layout for the same shall be approved in consultation with the Fire Officer, NIT/NMC, Director of Fire Services, Maharashtra and the same shall be of hard surface capable of taking the weight of fire engine, weighing up to 45 tones. The said open space shall be kept free of obstructions and shall be motorable.
c) Main entrances to the plot shall be of adequate width to allow easy access to the fire engine and in no case it shall measure less than 4.5m for a one way entrance and 6.5m for a two way driveway. The entrance gate shall fold back against the compound wall of the premises, thus leaving the exterior access way within the plot free for movement of fire engine / fire service vehicles. If main entrance at boundary wall is built over, the minimum clearance shall be 4.5m.
d) No building shall be at a distance of more than 25m from a means of access to a fire tender.
12.7 Access Requirements for Fuel Filling Stations
The width of the main street on which the fuel filling stations or fuel filling cum service stations shall abut shall not be less than 12m and one end of this street shall join another street of width not less than 12m in width subject to other conditions given in Regulation 48.