Basement shall be constructed within the prescribed setbacks and prescribed building line in one or two levels and may be put to only following uses. These shall be permissible free of FSI, except (c), (d), (e) and (f).
a) Air conditioning equipment and other machine used for services and utilities of the building;
b) Parking spaces
c) Strong room, bank cellars etc.
d) Storage of household or other goods of ordinarily non-combustible material;
e) Storage incidental to principal use; and
f) Shopping and related uses at only the basement level nearest to the ground level fronting road. Provided further, that uses given in (d) to (f) above may be permitted subject to adherence with Regulation 17.11.4 (g)
The basement shall not be used for residential, habitation or any uses other than those mentioned above.
Multilevel basements may be permitted if the basement is used for parking provided size of the plot is minimum 1,000 sqm. The ramps of minimum 3.5 m width for entry and exit of vehicle separately shall be provided. In case of bona-fide hardship, the Chairman, NIT may allow only one ramp with not less than 6.5 m. in width. (See regulation 19.4.6)
The basement shall have the following requirements -
a) Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of beam. Adequate ventilation shall be provided for the basement with a ventilation area not less than 2.5% of the area of the basement. Any deficiency may be met by providing in addition adequate mechanical ventilation in the form of blowers, exhaust fans, air conditioning systems etc.
b) The minimum height of the ceiling of any basement shall ordinarily be 0.9 m. and maximum of 1.2 m. above the average surrounding ground level. However it does not apply to the mechanically ventilated basements.
c) Adequate arrangement shall be made such that surface drainage does not enter the basement.
d) The walls and floor of the basement shall be water-tight and be so designed that the effect of the surrounding soil and moisture, if any, are taken into account in design and adequate damp proofing treatment is given; and
e) The access to the basement shall be separate from the main and alternate staircase providing access and exit from higher floors. Where the staircase is continuous in case of building served by more than one staircase, the same shall be of enclosed type serving as a fire separation from the basement floor and higher floors [see Regulation No. 19.4.3 (m)] Open ramps shall be permitted if they are constructed within the building line subject to the provision of (d).
f) Portion of basement beyond the building line shall not be within a distance less than half the margins of the site and the top of this shall align with ground level of the site.
g) In any circumstances, notwithstanding the uses given in 17.11.1 (d) to (f) above, a basement shall not be used for commercial use or storage of any kind or any such uses which may pose risk to life in case of an emergency.