| 1. Minimum area of plot | : | 4,000 m2. |
|---|---|---|
| 2. Maximum permissible Coverage | : | 286[10% subject to a maximum built up area of 1000m2 per holding. The maximum built up area permissible for a farm house irrespective of the area of plot will be <sup>287</sup>{1000m2}] |
| 3. Maximum permissible FAR. | : | 288[10 where area of plot exceeds 10,000 m2 with maximum built-up area of 1,000 m2]. |
| 4. Maximum permissible height | : | 7.60 meters from the ground level to the eaves of the roof, including stilts if any. * Relaxation in height can be considered for specific requirements in case of smoke houses and the like. |
| 5. Access | : | Farm house shall be accessible by a road of width not less than 6.0 meters (R/W) or a katcha carriageway of not less than 3.0 meters width. The access to the farm house shall not have the gradient of above1:6. |
| 6. Compound Wall | : | The compound wall for Farm House to be limited to the height of 1.50 meters [0.90 meter (solid type) and 0.60 meter above to be of wire mesh type] on the side abutting the road and may be solid for other sides. |
| 289[7. Setbacks | : | Front 30 meters or 3/4th depth of the plot whichever is less from the right of way line, if abutting a main road, i.e. MDR/SH/NH and main village road. All other setbacks should be minimum 5.00 meters with no projections in setback areas. For plots abutting SH/NH, prescribed setbacks as applicable shall have to be maintained. *The front setback can however be relaxed in case depth of the plot is not sufficient to maintain the 30 meters or ¾ depth of the plot guideline]. |
286Substituted vide Amendment Regulations, 2023.
287Corrected vide Corrigendum No. 21/1/TCP/2021-23/Steering Committee/113 dated 11-08-2023.
288Corrected vide Corrigendum No. 21/1/TCP/2021-23/Steering Committee/113 dated 11-08-2023.
289Substituted vide notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
212–
NOTE:
Farm house shall be used as residence of the owner and farm workers, for storage of agricultural produce, storage of agricultural equipments, manure, pesticides for the use of farming, smoke houses, parking of owners tractors and vehicles and other uses allied to agriculture. In case of single Farm House proposal in a property, the minimum access (R/W) required may be 6.0 meters (R/W) only. It shall not be used as a godown or for other any commercial purpose like club/hotel/casinos etc.
Farm houses are not permitted in low lying agricultural lands recorded as rice in the survey records or Forest lands as per Forest Act. However, pump houses of maximum area of 6 sq. meters and of height 1.8 meters may be permitted in such areas.
No hill cutting shall be allowed for construction of Farm house. Farm houses are not permitted in sloping land having slope above 25%. Farm houses shall be located and constructed in the flatter portion of the land not having slope of more than 25% slope and cutting shall be restricted to only for the plinth, foundation and for footing only.
Only one farm house per holding will be permitted. However for holdings above 20,000 m2 of area, additional auxiliary structures of non-habitable nature will be permitted not exceeding the maximum permissible coverage of 5%.
The design of the farm house should be in harmony with the surroundings and compulsorily have sloping roof with Mangalore tile cladding. However for farm sheds, poultry sheds/animal sheds etc., asbestos sheet and other kind of roofing materials would be permitted. As far as possible local materials should be made use for the construction.
The development in form of access, structures, retaining walls and compound wall should not cause blockage of the natural drainage system.
290[ANNEXURE – XI-A
For Agro Based Activities in Cultivable/Agriculture Zone/Orchards, etc.
| Sr. No. | Schemes of the Agriculture Department | Minimum area of the structure | Type of structure | Proposed FAR in percentage to net plot area |
|---|---|---|---|---|
| (1) | Protected cultivation for growing flowers and vegetables. The farmer gets 100% assistance against standard construction costs. Back ended programmer with a ceiling of maximum assistance for plot area of 4000 sq. mts. per individual green houses, shade, net houses, plastic tunnel | 500. mts. | (1)Tubular structure (steel or plastic) (2)Wooden Structure (3) Plastic tunnels | 50 |
| (2) | Grading and packing house (As per project) | - | Temporary/Permanentstructure | 5 |
290 Inserted vide Amendment Regulations, 2015.
213–
| (3) | Pre-cooling/primary proceeding unit (as per project) | 200 sq. mts. | Temporary/Permanentstructure | 5 |
|---|---|---|---|---|
| (4) | Cold storage | As per project | Temporary/Permanentstructure | 15 |
| (5) | Mushroom production unit | As per project | Temporary/Permanentstructure | 30 |
| (6) | Pump house with storage for tools and inputs | 30 sq. mts. | Temporary/Permanentstructure | 30 sq. mts. permitted |
| (7) | Water storage tank -10 cu. meter storage | - | Temporary/Permanentstructure | ____ |
| (8) | Dairy/Poultry/Piggery | 300 sq. mts. | Temporary/Permanentstructure | 20 |
Note: 291{(1) For all above activities, minimum size of land/plot has to be 4000 sq.mts. except in case of pump houses and dairy farming. In case of dairy farming the minimum plot requirement can be relaxed provided that a minimum plot size of 1000 sq.mts. shall be maintained and the area of structure on such plot shall be restricted to 100 sq.mts., provided further that the plot is surrounded by agriculture areas and preferably away from dense human habitation.}
(2) Prior approval of Director of Agriculture/Director of Animal Husbandry (as the case may be) shall be obtained and accompanied by a project report.
(3) The activities listed at Nos. 2, 3, 4 and 8 may not be permitted in wet cultivated paddy fields.
(4) The activities listed at No. 1 and 5 may be permitted in wet cultivated paddy fields provided the structures are of temporary nature only.
(5) Front set-back for such activities is relaxable to 10.00 mts. from the right of way line and all other set-backs shall remain the same as per farm house guidelines.
(6) A residence for staff/labourers, having a ground floor only and not exceeding 6.00 mts. height upto ridge may be permitted but only as auxiliary to the main use. However, the same shall not be permitted in wet cultivated paddy fields. Also, toilet facilities may be permitted for the activities listed at Nos. 1, 2, 3, 4, 5 & 8.
(7) The area under the residential use for the staff/labourers shall be restricted to 50.00 sq. mts. maximum of the total built up area proposed in the plot.
(8) The structure permitted for the activities listed at Nos. 1 to 8, shall be in addition to any other structure as permitted under Goa Land Development and Building Construction Regulations, 2010, in the same plot.]
291 Substituted vide Amendment Regulations, 2019.
214–
292[ANNEXURE-XII
27.XII
The requirement of minimum width of road for various residential buildings, commercial buildings (Resort/hotels) and Industrial buildings with restrictions shall be as follows:
Minimum width of road and extent of units/floor area in respect of residential buildings
| Minimum width of existing road required in meters.** | No. of units | Total Maximum floor area of entire/all building |
|---|---|---|
| 3 mts. or more, but public road | 1 (single dwelling) | 500 m2 |
| PUBLIC ROADS | ||
| > 3 upto 4 mts. | 2 units | 400 m2 |
| > 4 upto 5 mts. | 4 units | 600 m2 |
| > 5 upto 6 mts. | 8 units | 1000 m2 |
| 6 mts. or greater | 180 units | 20,000 m2 |
| 8 mts. or greater | More than 180 units | > 20,000 m2 |
** The project proponents shall leave the road widening area as prescribed in the Regional Plan/Outline Development Plan, and other roads not less than 6.0 mts. Most restrictive criteria among no. of units and floor area shall be considered for fixing the minimum width of access.
Minimum width of road and extent of rooms/floor area in respect of Resorts/hotel buildings
| (1) | (2) | (3) | (4) | (5) |
| Sl. No. | Type of Occupancy | Total floor area of the building in sq. mts. | Number of rooms | **Minimum width of existing road required in meters. |
| 1 | Resorts/Hotel | Up to 2000 | 40 | 6 |
| Above 2000 | More than 40 | 8 |
** The project proponents shall leave the road widening area as prescribed in the Regional Plan/Outline Development Plan and the Resorts/Hotels shall be allowed on proposed road widths of atleast 8.0mts. Most restrictive criteria among no. of rooms and floor area shall be considered for fixing the minimum width of access.
Minimum width of access and extent of floor area and number of storeys in respect of Industrial buildings
| Sl. No. | Type of Occupancy | Total floor area of the building in sq. mts. |
|---|
293[ANNEXURE - XIII
For granting additional FAR of 294[30%] for 4 and 5 star hotels in the State of Goa.
(1) Any existing hotel or hotel under construction or new proposals of 4 star and 5 star categories of hotels are eligible to avail this benefit.
(2) The project proponent has to submit details to the office of the Chief Town Planner, Town and Country Planning Department, Panaji, Goa, comprising of the following:
(i) A Copy of approved plans of the project (applicable to existing hotels).
(ii) A copy of construction licence from the local body (applicable to existing hotels).
(iii) A copy of conversion Sanad.
(iv) A letter confirming star category of hotel, issued by the Ministry of Tourism, Government of India.
(v) The detail report pertaining to infrastructure to be made available such as sewerage treatment plant, solid waste disposal details by taking into consideration additional area being added.
(vi) Plans indicating additional FAR, complying with other prevailing regulations of parking, set-back, access, etc.
(vii) A certificate from consultant that building confirms to the guidelines of 4 and 5 star rating hotels, both for new hotels and for the hotels under constructions.
(viii) A bank guarantee as specified by the Government from time to time shall be issued by the project proponent, guaranting compliance of requirement of 4 and 5 star rating criteria. In case the project proponent fails to submit star category certificate from the specified Competent Authority within 2 years of completion of the hotel, the bank guarantee is liable to be forfeited in favour of the Government.
(ix) The maximum permissible height of the building shall be relaxed for one additional floor only and shall not exceed the building height of 24.00 mts. The building height may be relaxed by the Government to 28.00 mts. in commercial (C-1) zone, on merit of the case, subject to fulfilling the requirement of parking, fire safety measures, etc.
(x) In case of existing buildings, relaxation of 5% additional coverage may be considered by the Government.
(xi) The calculation of 295[30%] additional FAR shall be on total net effective plot area.
296[(xii) The payment of Rs. 20,000/- per square meter for additional FAR shall be deposited within 30 days of issue of demand note for payment]
293 Inserted vide Amendment Regulations, 2015.
294 Substituted vide Amendment Regulations, 2023.
295 Substituted vide Amendment Regulations, 2023.
296 Substituted vide Notification No. 21/1/TCP/2015/Steering Comm/16/5145 dated 21-12-2016.
216–
(xiii) Adequate additional parking provision to commensurate with the additional built-up area permitted depending on categories of land use and size of development, as specified at Regulation No. 10 (parking) of the Goa Land Development and Building Construction Regulations, 2010.