115[TABLE-IV]
| Height of the building | Side/Rear Setbacks |
|---|---|
| (1) | (2) |
| 7.60 m. | 3.00 m. |
| 9.00 m. | 3.50 m |
| 11.50 m. | 4.00 m. |
| 15.00 m. | 5.00 m. |
| 18.00 m. | 5.50 m. |
| 21.00 m. | 6.00 m. |
| 24.00 m. | 6.50 m. |
| 28.00 m. | 7.40 m. |
| 116[32.00 m. | 8.00 m. |
| 36.00 m. | 8.00 m.] |
114 Substituted vide Amendment Regulations, 2016.
116 Added vide Amendment Regulation, 2018(September).
115 Titled as Table-IV vide Notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
– 51–
117[Note: After 36.00 mts. height the side/rear setbacks shall be increased by 1.00 mtr., for every 4.00 mts. additional height, provided further that the maximum setback which can be insisted by the authorities shall be atleast 15.00 mts., irrespective of the height of the building.]
118[(a) In existing Municipal areas notified prior to the commencement of these Regulations, the building may be allowed with the side setbacks less than those specified in table-IV limited to a minimum 1.5 meters provided that no light and ventilation is taken from that side. However, in densely built up existing areas, where neighboring building or building existing within the applicant‘s plot, are already touching the boundaries, the building may be allowed to touch the boundary or keep 1.50 meters or less on one or both sides, provided that no light and ventilation is taken from that side]
119[(b) In industrial estates/industrial areas minimum 3.00 mts. side setback shall be maintained in case the area of the plot does not exceed 1,000 sq. mts. and minimum 4.50 mts. side setback shall be maintained at least on one side for plot where the area of the plot exceeds 1,000 sq. mts.].
4.5. Restrictions on development within setbacks.— The setbacks, as required to be provided under these Regulations, shall be kept permanently open to sky and they shall not be used for stacking materials or loose articles for the purpose of trade or otherwise, nor they shall be used for putting up fixed or movable platforms or advertisement hoarding boards or neon sign boards or for such similar uses.
However, plantations/orchards, septic tanks, pump, well, gardening 120[, rain water harvesting/ground water recharge system] will be permitted in the said setbacks provided no structure shall impede the access and circulation of vehicles.
4.6. Projections within the setbacks.— Following projections shall be allowed within the setbacks provided that there is no obstruction/interference with line of sight or street furniture, fixtures, lighting, access, etc.
(a) Within Front setback.— (i) An un-storeyed porch/canopy/cantilevered stair landing projection, provided that a minimum setback of 2.00 meters is left between the R/W of the road/street and the extreme edge of the canopy, there is a clear distance of 2.50 meters between the ground and the bottom of the porch/canopy/stair landing, and no columns are located within the setback.
(ii) Balconies/verandah, floor projections which are cantilevered and there is a clear distance of 2.50 meters from the bottom of such projections and ground and 2.00 meters setback is left between the R/W of the road/street and such projection.
(b) Within Side and Rear setbacks.— Cantilevered weather board, sun shades, chajjas, balconies, canopies or stair landing projections, provided that they are at a minimum height of 2.50 meters from the ground, and not more than 1.5 m. in depth and not more 1/3rd of the side setback. The minimum height shall be 4.50 meters along the side giving access to the rear.
117 Inserted vide Amendment Regulation, 2018 (September).
118 Substituted vide Amendment Regulations, 2016.
119 Inserted vide Amendment Regulations, 2018.
120 Inserted vide Notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
52–
(c) Security cabin of not more than a size of 6.00 square meters of 2.50 meters height provided it does not interfere with line of sight in a corner plot or road junction. Provided the main gate is partially recessed by at least 1.00 meter.
4.7. Further restrictions/relaxations.— (a) 121[For original survey plots or mundkarial plots or plots of approved layout having frontage up to 13.00 meters, construction of single dwelling units may be permitted with side setbacks of 1.50 meters allowing normal light and ventilation, provided the construction is limited to ground and one upper floor only and that no projection shall be permitted except of weather board, sun shades, roof projections or any architectural features not exceeding 30.00 cms. In case of multi-dwelling units, side setbacks can be relaxed to 1.50 meters on one side only with the above restrictions/control. Un-storied car porches of maximum length of 5.00 meters may be permitted to touch the boundary, provided rain water drain and disposal are within the plot.]
(b) When the construction is permitted to touch the boundary under clause 4.4.2 (b) in Municipal areas, the said setback shall be provided with a permanent wall/screen or any architectural feature, extending to the boundary, on the face of the building abutting the street, to maintain the continuity of the streetscape. An opening to serve as an emergency access only, may be provided in this wall/screen at the ground floor. This shall be applicable to any plot, irrespective of its size.
4.8. Distance between two buildings.— (a) The minimum distance between two buildings within the same plot shall not be less than three meters in case no ventilation or light is taken from facing sides.
(b) The minimum distance shall be half the mean height of the two buildings or three meters, whichever is more, in case light and ventilation is taken from facing sides and this distance shall be measured at point where such light and ventilation is taken. No projections shall be permitted within the minimum distance 122[except chajjas/weather boards].
4.9. Courtyard.— The sizes of the Courtyards provided in the development shall conform to the following provisions:–
(a) If light and ventilation is taken to the habitable rooms from a courtyard, then the minimum area of the Courtyard shall be 10.00 m2 and the smallest side shall be determined, as per the Table-IV for side setbacks given at 4.4.2 above.
(b) If light and ventilation is taken to non habitable rooms from a courtyard, then the minimum area of the courtyard shall be 6.25 sq. mts. with the smallest side not less than 2.50 mts. for courtyard having height upto 11.00 mts.
The minimum area of the courtyard shall be 9.00 sq. mts. with minimum side of 3.00 mts. for courtyard having height above 11.00 mts.
4.10. Regulations regarding development on sloping sites.— (a) When submitting plans for development of a plot which has a gradient of 1:10 or more, the plan should
121 Substituted vide Notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
122 Inserted vide Notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
53–
indicate block levels at 5.00 m. centre to centre or alternatively contour plans at 1.00 m. intervals.
(b) Block levels/contour plans are also to be submitted in case plot area exceeds 1000 sq. mts. for building operations.
(c) Block levels/contour plans are also to be submitted in case plot area exceeds 10000 sq. mts. for sub-division of land.
(d) The levels/contours should be drawn with reference to a bench mark clearly indicated on the site plan.
(e) No development shall be permitted if the gradient exceeds 1:4.
(f) The Chartered Surveyor or Civil Engineer shall certify the contour plans and shall be responsible for the accuracy of the said plan.
4.11. Development of Landlocked areas.— Development of any land locked area i.e. area without access or with inadequate access shall be governed by the following regulations:-
(a) If the area is accessible by a traditional access, passing through a property of different owner or is proposed to be made accessible by an access having a width of 3 m. or less, development shall be limited to a ground floor and one upper floor structure with a maximum floor area of 200 m2 to be used for residential use only. Such access shall have to be marked on the site plan.
(b) If the area is proposed to be made accessible by an access having a width of more than 4.50 m. but less than 6 m. development shall be limited to a ground floor and one upper floor structure with a maximum floor area of 350 m2 to be used for residential use only. Such access shall have to be marked on the site plan.
123[(c) If any property is made accessible by an access/road through a property of different owner by his voluntary consent, the area used for such access/road shall not be deducted from the effective area of the plot in which it is provided, for the purpose of coverage and FAR calculations provided that the width of such access is 3.00 meters or more and has concurrence of the Authority/Council/Panchayat.]
(d) In case such an access is not voluntarily made available, then the 124[Authority/ /Council/Panchayat/Town & Country Planning Department] at the request of the owner of the landlocked property, shall acquire the area of such access based on the micro planning of the area. The width of such access shall not be more than 6.00 meters and shall not render the plot unfit for development. The cost of acquisition of the area alongwith 5% service charges shall be borne by the said owner. The minimum service charges shall be Rupees five thousand or as decided by the Authority from time to time. If due to such acquisition, the owner is not able to develop his property with full benefit of FAR due to other restrictions like coverage, setbacks, etc., the 125[Authority/Council/Panchayat/Town & Country Planning Department] may relax such requirements on individual merit.
123 Substituted vide Amendment Regulations, 2016.
124 Substituted vide Amendment Regulations, 2023.
125 Substituted vide Amendment Regulations, 2023.
54–
4.12. Land Acquisition by the Competent Authority.— (a) The land zoned as P (public, semi public and institutional) and the land zoned as R (parks, playgrounds, recreational) may be acquired by the Competent Authority, to the extent of minimum size of plot specified in the Regulations of the said zones, at the request of the institution for the purpose of allowable development in the said zone.
(b) The land required for development of common facilities/services, such as a crematorium, cemeteries etc., for the uses as permitted in specific zones, may be defined and acquired by the Competent Authority on request of the Institution or local body.
- Group Housing.— Group of buildings in an effective area of plot more than 4000 m² but less than 20,000 m²:
126[(a) When a plot, having an area of more than 4000 m2 but less than 20000 m2, is used for construction of building/group of buildings, an open space, as per the provisions in sub-division Regulations (12) shall be provided, in addition to the parking requirements. However, for calculating the coverage and FAR, the area of the entire plot, inclusive of the open space, shall be taken as effective plot area. However, this provision shall not be applicable to single family dwelling unit.]
(b) All the buildings should be provided with a minimum 127[ ] access of 3.00 m. and minimum setback of 1.50 mts. on either side of the access shall be applicable.
(c) All parking areas shall be accessible by an internal road having a minimum width of 6.00 meters. If such parking is provided within buildings, then the access to these buildings shall also be 6.00 meters and a setback of 1.00 meter from the road shall be necessary.
(d) A road of 6.00 m. width shall be extended to the rear of the plot or adjoining plot, in case the same is without an access. The general regulations regarding the road setbacks would not be applicable.
(e) Commercial use will be permitted as per the provisions of Regulation 6.A.1.
(f) 128[In case of plots exceeding 20,000 m2 in area, internal access roads shall be provided as per sub-division regulations or a hierarchy of roads shall be followed, subject to above Regulations 5 (a) to (d)].
(g) No part of building shall be allowed to be projected over the road/access including balcony.
Note: In case of high rise building the regulations applicable for fire safety shall be adhered to.
129[5A. Regulations for Shopping Mall cum multiplex.— (1) Definition:– ―Shopping mall cum multiplex‖ shall mean an integrated entertainment and shopping
126 Substituted vide Amendment Regulations, 2016.
127 Deleted vide Notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
128 Substituted vide Notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
129 Inserted vide Amendment Regulations, 2019.
55–
Centre/Complex consisting of small retail outlet, food courts, pubs, bowling alleys, restaurants, fast food outlets, health spas/centers, convention centers, hotel, IT and ITES, recreational activities, etc., with at least 2 cinema hall screens either within the complex or in a separate building within the compound of the complex.
(2) Site requirement for shopping mall cum multiplex:– (i) The minimum size of plot for a new shopping mall cum multiplex complex shall be 10,000 sq. mts.;
(ii) The minimum abutting road width for a shopping mall cum multiplex complex shall be 15 mts. existing.
(3) Location criteria:– (i) The location of a shopping mall cum multiplex complex shall be in a notified commercial area as per the statutory plans in force. The project shall be further subject to the requirements of,—
(a) a traffic impact study and a traffic management plan, for such complex undertaken through a qualified consultant in traffic and transportation.
(b) NOC from the Director of Fire and Emergency Services for considering the building permission by the Authority granting the permission.
(4) General:–
Plot area – 10,000m2
Coverage – 50%
FAR – As per the permissible FAR in respective zone.
Height – Maximum height permissible shall be as per the permissible limits within the respective zones. Maximum height of shopping mall cum multiplex having assembly occupancy shall not exceed 30 mtrs. or the height permissible in the respective zones, whichever is less. However, relaxation in height could be considered with the approval of the Town and Country Planning Board for creating iconic or landmark tower which would have tourist/public attractions and would enhance the image of the city by following setback requirements up to a maximum height of 50.00 mtrs. only in C1 Special Zone (C1 Special), Commercial Special Zone (CS) and Special Commercial Zone (SPC). This relaxation in height is subject to condition that uses in the tower shall be of non-assembly occupancy. If such tower is attached to the main shopping complex cum multiplex, it should have separate entry and exit from the ground level and overall height of the building including the tower shall not exceed 50 mtrs. If the tower like building is proposed as detached building within the same compound of the complex, maximum height of 50 mtrs. could be considered, independently. The relaxation in height will be further subject to the condition that the tower like building shall not cover more than 33% of the overall plinth area of shopping mall cum multiplex.
Note: The additional height upto 50 mtrs. can be permitted subject to availability of fire equipments capable of handling high rise building of such magnitudes by the Director of Fire and Emergency Services. However, exemptions could be considered in case the prospective developer donates the equipments as required by the Government and make available in house fire fighting facilities within the complex.
(5) Parking:— One equivalent car parking space shall be provided for every 35 sq.mtrs. of built up area of the shopping mall cum multiplex.]
56–
6. Zoning Regulations and use provisions.—
6.1. Introduction.— To regulate the development in terms of FAR, coverage, use of building, height of building, and other zoning regulations, and the use of the plot within the zone/use designated in—
(a) Regional plan of Goa.
(b) Development Plans (Notified).
(c) Development Plan of Withdrawn Notified Areas.
(d) Part-Regional Plan/Zoning Plans/Town Planning Scheme or any other plan prepared for development control as the case may be.
6.1.1. The following Regulations shall be applicable in the respective zones.— 130{The following Regulations shall be applicable in the respective zones:
(a) Regional Plan for Goa: The settlement zone areas means the areas which could be brought under development for various uses and the compatibility of the said uses/zones within the settlement level plans. FAR applicable shall be as per Table-V given below.
TABLE – V
| VP Status | Area of Plot | FAR permitted | Height |
| VP1 | Area below 4000 m2 | 80 | As per S2/R2 |
| 131[ ] | |||
| VP2 | Area below 4000 m2 | 60 | 9.00 mts. including stilt |
| 132[ ] | |||
Note: 133[(1)] The above shall be applicable for all types residential, commercial, industrial and institutional buildings.
134[(2) The Government on recommendation of the Town and Country Planning Board shall grant additional height and FAR to the proposals on case to case basis in consideration of the locational aspect, nature of development, use proposed, information available and on any such other criteria, if required. Such relaxation shall however not be relaxed for more than 20% permitted in the prevailing Regulations.].
Any other provisions, the interpretation of which is not clear, shall be referred to the Chief Town Planner/Member Secretary, Town and Country Planning Board of Government of Goa and interpretation given by Town and Country Planning Board shall be treated as final and shall form part of these Regulations.
(b) Outline Development Plans/Comprehensive Development Plans: These are plans as notified/to be notified for existing planning areas declared under Section 18 of The Goa Town & Country Planning Act, 1974. These Regulations shall be applicable for all developments.
130 Substituted vide Notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
131 Omitted vide Amendment Regulations, 2023.
132 Omitted vide Amendment Regulations, 2023.
133 Numbered vide Amendment Regulations, 2023.