5.1 Kitchen:
Every room to be used as a kitchen shall have—
(a) Unless separately provided in a pantry, means for washing of kitchen utensils, which shall lead directly or through a sink to a grated and trapped connection to the waste pipe.
(b) An impermeable floor.
(c) At least a window not less than 1 sq. m. in area open directly to an interior or exterior open space, but not into a shaft, and
(d) In residential building 15 m. or more in height, refuse chutes.
5.2 Bathroom and W.C.C.:
Every bathroom or water closet compartment shall—
(a) Be so situated that atleast one of its walls shall open to external air and shall have a minimum opening in the form of window or ventilation to the extent of 0.37 sq. m.
(b) Not be directly over any room other than another latrine, washing place, bath or terrace unless it has a watertight floor.
(c) Have the platform or seat made of watertight non-absorbent material.
191–
(d) Be enclosed by walls or partitions and the surface of every such wall partition shall be finished with a smooth impervious material to a height of not less than 1.0 m. above the floor of such a room.
(e) Be provided with an impervious floor covering, sloping towards the drain with a suitable grade and not towards verandah or any other room.
(f) No room containing water closet compartments shall be used for any purpose except as a lavatory.
(g) Every water closet compartment and/or a set of urinals shall have flushing cistern of adequate capacity attached to it.
(h) A toilet on terrace having a maximum of 2.2 mt. height shall be permitted subject to condition that the area of toilet be counted in FAR.
(i) All the sewage outlets shall be connected to the Municipal Sewerage system. Where no such system exists, a septic tank with soak pit shall be provided within the plot conforming to the requirements of the Health Department.
5.3 Loft:
Lofts shall be permitted in residential building and shops only. Area of such loft shall be restricted to 25% of the covered area or respective floor. Minimum height between loft and ceiling shall be 1.75 m. and the clear height below the loft shall be as stipulated in these Regulations for the space below it.
5.4 Mezzanine Floor:
Mezzanine floor may be permitted with the minimum height of 2.75 m. between any two floors above ground in all types of building provided the same is counted as part of total permissible floor area ratio and height of the building.
5.5 Garage:
(a) The plinth of garage located at ground level shall not be less than 15 cm. above the surrounding ground level.
(b) The garages shall be setback behind the building line of the street/road on to which the plot abuts and shall not be located affecting the access ways to the building. If the garage is not setback as aforesaid, the Authority may require the owner or occupier of the garage to discontinue its use as such or to carry out such structural alterations to the premises or to take such other measures as the Authority may consider necessary in order to prevent danger or obstruction to traffic along the street.