13.1 All habitable rooms shall have for the admission of light and air, one or more apertures, such as window, glazed door and fan lights, opening directly to the external air or into a open verandah not more than 2.40 meters in width. In case light and ventilation to habitable space area are through an internal courtyard, the minimum dimensions of such courtyard shall not be less than 3.00 mts. x 3.00 mts. for buildings up to 12.50 meters in height. For buildings with higher heights, the minimum dimensions of the internal courtyard shall be as per these Regulations.
13.2 Where the lighting and ventilation requirements are not met through day lighting and natural ventilation, the same shall be ensured through artificial lighting and mechanical ventilation as given in part-VII building services Section-1 lighting and Ventilation of National Building Code of India published by the Bureau of Indian Standards. The latest version of the National Building Code of India shall be taken into account at the time of enforcement of the Building Regulations.
Notwithstanding the above, the minimum aggregate area of openings of habitable rooms and kitchens excluding doors shall be not less than 1/10 of the floor area.
No portion of a room shall be assumed to be lighted if it is more than 7.50 m. from the opening assumed for lighting that portion.
13.3 Ventilation Shaft:
For ventilating the spaces for water closets and bathrooms, if not opening on the front side, rear and interior open spaces, shall open on the ventilation shaft, the size, of which shall not be less than the values given below:
TABLE-VII.4:
| Height of Building in meters | Size of ventilation shaft in sq. meters | Minimum size of shaft in meters |
|---|---|---|
| 9.0 | 1.5 | 1.0 |
| 12.5 | 3.0 | 1.2 |
| 15 and above | 4.0 | 1.5 |
*For commercial buildings, mechanical ventilation system shall be installed besides the provision of minimum ventilation shaft.
14. Parapet:—
Parapet walls and handrails provided on the edges of roof terrace, balcony etc. should not be less than 1.0 m. and more than 1.5 m. in height.
Note: The above shall not apply where roof terrace is not accessible by a staircase.
196–
- VIII
ANNEXURE-VIII
ADDITIONAL SPECIAL REQUIREMENTS FOR OCCUPANCY/LAND DEVELOPMENT (From the National Building Code of India, 2005 placed in these Regulations for reference and information only)
1. Industrial Buildings (Factories, Workshops etc.).—
(a) The relevant provisions contained in the Factory Act, 1948 shall apply for the construction of factory buildings. The minimum internal height of workrooms shall not be less than 4.5 m. measured from the floor level to the lowest point in the ceiling provided that this bye-law shall not apply to room intended for storage, go-downs and the like purposes but only in rooms occupied by workers for purposes of manufacture.
In case of small factories, employing less than 50 workers for purposes of manufacturing and carrying on a class of manufacturing covered under the flatted factories and service industries, as given in the Master Plan/Development Plan, the Authority may allow minimum height up to 3.66 m.
(b) Parking space provisions as provided in development code of Master Plan/Development Plan.
(c) Requirements of water supply, drainage and sanitary installation shall be as per the National Building Code of India Part-4 Fire & Life Safety, but in no case less than 1 W.C. and one urinal shall be permitted.
(d) (i) Notwithstanding the provision of exits requirements as per the National Building Code of India Part-4 Fire & Life Safety, each working room shall be provided with adequate number of exits not less than two in number.
(ii) No exit shall be less than 1.2 m. in width and 2.1 m. in height and doors of such exit shall be so arranged that it can be opened easily from inside.
No staircase, lobby corridors or passage shall be less than 1.20 meters in width. In addition to the requirement in this part, provisions contained in National Building Code of India shall be followed.
(e) There shall be provided at all time for each person employed in any room of factory at least 3.50 square meters of floor space exclusive to that occupied by the machinery and a breathing space of at least 15 cum. (Further the provision of Part-8 Section-1 lighting and ventilation of National Building Code of India shall be followed).
(f) The effluent from industries (industrial and biological in nature) shall be treated and shall be of quality to the satisfaction of the concerned local bodies before letting out the same into a watercourse or municipal drain.
2. Educational Building (School/Colleges).—
(a) No basement or cellar room shall be designed, constructed, altered, converted or used for the purpose of study or instruction.
(b) Every such building, exceeding two storeys in height shall be constructed of fire resisting material throughout.
(c) The minimum size of a cellar room, study room or room used for purposes of instruction shall be 5.50 mts. x 4.50 mts. and no part of such room shall be distant more than 7.50 meters from an external wall abutting on the requisite open space. Every such room shall have minimum ventilation to the extent of 1/5th of its floor area.
197–
(d) A minimum of 1.0 sq. m. of net floor space per student shall be provided. A central hall will not be counted in the accommodation, nor will a class room for cookery, laundry, manual instruction, drawing or science. The number of students in such building shall be calculated on this basis for the purpose of this clause.
(e) Every assembly room, gymnasium shall have a clear height of 3.60 meters except under a girder which may project 0.60 meters below the required ceiling height.
A clear internal height under balcony or a girder shall not be less than 3.00 meters. A minimum room height for classroom in all schools and other institutions shall not be less than 3.00 meters. The minimum head room under beams shall be 2.75 meters.
(f) Exit requirements shall conform to these Regulations 15.5 (a) (vi). No door shall be less than 1.20 meters in width and 2.20 meters in height.
(g) Requirement of water supply, drainage and sanitary installation shall conform to Building Services at 14.
(h) Playground shall be provided as per norms.
3. Assembly Building (Cinema, Theatres, etc.).—
(a) The relevant provisions of the Cinematographic Rules/Acts of the particular States and IS: 4878 code for construction of Cinema Building shall apply for planning, design and construction of Cinema Building.
(b) Parking spaces wherever not specifically given shall conform to the Regulation 10.
(c) Requirements of water supply, drainage and sanitation shall conform to Building Services at 14.
(d) Buildings for religious worship shall not be erected on a site, which has not been previously approved by the Authority.
4. Burial and Cremation Grounds.—
The Authority shall under the provisions of their Regulations/Acts, regulate the location and area limits of the burial and cremation grounds, including cemetery. Further, the Authority shall prohibit certain burial and cremation grounds to be located in certain area, which in their opinion is dangerous or likely to be dangerous to the health and well being of the persons living in the neighborhood or to be offensive to such persons.
5. Building in mining area.—
Building in mining area shall not be constructed to a height more than one storey without the special prior approval of the Authority.
- Poultry Farms (wherever allowed as per Plan).—
6.1. The coverage for poultry farms shall be as allowed in case of farmhouses.
6.2. Setback: The setback for farm building from the right of way shall be as under:
TABLE: 8.1
| Road(R/W) | Front Setback |
|---|---|
| National Highway (90 m.) | 60 m. |
| State Highway (60 m.) | 37 m. |
| Major District Road (30 m.) | 22 m. |
| Village Road (18 m.) | 13 m. |
198–
6.3 Space Planning:
(a) There should be a minimum distance of 6.0 mt. between sheds in the farm.
(b) The minimum distance of any farm building from the property line should be 4.5 m.
(c) The minimum distance of any farm shed or farm building from the dwelling unit should be 7.5 m.
6.4 Farm Shed:
See REGULATIONS FOR FARM HOUSE AND OTHER AUXILIARY STRUCTURES FOR POULTRY OR ANIMAL SHEDS IN Agricultural lands at Annexure XI.
6.5. Farm House:
See REGULATIONS FOR FARM HOUSE AND OTHER AUXILIARY STRUCTURES FOR POULTRY OR ANIMAL SHEDS IN Agricultural lands at Annexure XI.