8.1 General: The following general requirement shall apply to exits:
(a) Every building meant for human occupancy shall be provided with exits sufficient to permit safe escape of occupants in case of fire or other emergency.
(b) In every building exit shall comply with the minimum requirement of this part, except those not accessible for general public use.
(c) All exists shall be free of obstructions.
(d) No buildings shall be altered so as to reduce the number, width or portion of exits to less than required.
(e) Exits shall be clearly visible and the routes to reach exits shall be clearly marked and signs posted to guide the occupants of floor concerned.
(f) All exit ways shall be properly illuminated.
(g) Fire fighting equipment where provided along exits shall be suitably located and clearly marked but must not obstruct the exit way and there should be clear indication about its location from either side of the exit way.
(h) Alarm devices shall be installed to ensure prompt evacuation of the occupants concerned through the exits, wherever required.
(i) All exits shall provide continuous means of egress to the exterior of a building or to an exterior open space leading to a street.
(j) Exits shall be so arranged that they may be reached without passing through another occupied unit, except in the case of residential buildings.
9. Projections into set-back areas:
(a) Every interior or exterior open space shall be kept, free from any erection thereon and shall be open to the sky. Nothing except cornice, chajja or weather shade (not more than 0.75 m. wide) shall overhang or project over the said open spaces so as to reduce the width to less than the minimum required.
Note: Such projections shall not be allowed at a height less than 2.20 m. from the corresponding finished floor level.
(b) A canopy or canopies each not exceeding 4.50 m. in length and 2.40 m. in width in the form of cantilever or cantilevers, over the main entrance/entrances, providing a minimum clear height of 2.50 m. below the canopy.
In single storeyed residential building, only one such canopy shall be permitted for each individual detached block. In more than one storeyed residential building, two canopies shall be permitted over ground floor/higher floor entrances. In buildings of other occupancies, the permissibility of canopy, canopies shall be as decided by the Authority on its merits.
194–
(c) In case of residential building only, a balcony or balconies at roof level of a width of 1.50 meters overhanging in set backs within one‘s own land and courtyards provided the minimum area required shall not be reduced by more than 30% of such set back areas.
(d) The projections (cantilever) of cupboards and shelves shall be permitted and are exempted from covered area and FAR calculations in case of residential buildings only. Such projection shall be up to 0.75 m. depth provided.
(i) That no cupboard shall project in the side set back on the ground floor.
(ii) That outer length of cupboard overhanging in the set backs shall not exceed 2.0 m. per habitable room. In addition to this, cupboard under the above and windows can be provided.
Note: Cupboard means a space used for storage of household goods/clothes, having shelves/partitions not more than 1.5 m. apart.
(iii) Only one pergola on each floor shall be permitted in a residential building if constructed in the exterior open spaces or terrace. Such pergola shall not exceed 3.50 sq. m. in area on which 40% shall be void and shall have a clear height 2.20 m.
- In addition to above, the following shall not be included in covered area and FAR calculations:—
(a) Machine room for lift on top floor as required for the lift machine installation.
Note: The shaft provided for lift shall be taken for covered area calculations only on one floor.
(b) Rockery, well and well structures, plant nursery, water pool, swimming pool (if uncovered), platform round a tree, tank, fountain, bench, chabutara with open top and/or unenclosed sides by walls, open ramps, compound wall, gate, slide swing door, uncovered staircase (uncovered and unclosed on three sides except for a 0.90 m. high railing/wall, overhead water tank on top of building/open shafts.
(c) A mumty over staircase on top floor.
(d) Culvert on Municipal drains.
11. Height Limit:
The height and number of storeys shall be related to provisions of Zoning given in Regulation 6A.4 and the provisions of set-back given in these Regulations, subject to the following:
(a) The height of building shall depend upon the Zone and as given in Regulation 6A.4.
(b) If a building abuts on two or more streets of different width, the building shall be deemed to face upon the street that has the greater width and the height of the building shall be regulated by the width of that street. Height shall however, not exceed the maximum height as provided in the Master Plan.
(c) For buildings in the vicinity of the aerodromes the maximum height of such buildings shall be subject to clearance from the Civil Aviation Authorities from time to time and to this effect a no objection certificate issued by that Authority shall be submitted by the applicant along with plans to the sanctioning Authority.
Note: The location of slaughter house/butcher house and other areas for activities like depositing of garbage dumps which would attract high flying birds like eagles/hawks etc. shall not be permitted within a radius of 10 km. from aerodrome reference point.
195–
12. Height Exemptions:
The following structures shall not be included in the height of building covered under these Regulations.
Roof tanks and their supports not exceeding 1.0 m. in height, ventilating, air conditioning and lift rooms and similar service equipments, stair covered with Mumty not exceeding 3.00 m. in height. Chimneys and parapet wall and architectural features.