In existing crematorium a buffer/safety zone of 30.00 meters between cremation platform and for cemeteries/graveyard, a buffer/safety zone of 15.00 meters between grave yard and the nearest settlement area.
Proposed
Any proposal for development of crematorium shall provide, within the plot area itself, a buffer/safety zone of 30.00 meters between cremation platform and the nearest settlement area.
For grave yards/cemeteries shall provide, within the plot area itself, a buffer/safety zone of 15.00 meters between grave yard and the nearest settlement area.
Note: The buffer/safety zone in the existing crematoriums may be relaxed up to 15.00 meters in case the various constraints and needs of the area, provided that such relaxation is specially requested, and may be placed before the Board by the Chief Town Planner with his comments and thereafter the Board may consider the relaxation on case to case basis.
9.3Structures for Non-Conventional Energy Sources:
Any structures proposed for installation of any non-conventional energy, shall be exempted from coverage, FAR, height, use, etc.
Note:
Special Buildings not covered:
Any building/structures which are not specifically defined or covered under these Regulations shall be treated as Special Buildings. Such buildings/structures shall be dealt with as per the provisions contained in the National Building Code of India.
10. Parking.—
(a) Off street parking spaces for vehicles shall be provided in case of every new building proposed to be constructed or when new additions are made to the existing building, as specified in 185[TABLE-IX-A], depending on the use of the building.
186[TABLE-IX-A
Type of Use
Minimum Parking Requirement
I.
Residential buildings/ Flats/Apartments
1.00 for every dwelling unit
Upto floor area of 75 m2
1.25 for every dwelling unit
Floor area more than 75 m2 up to 100 m2
1.50 for every dwelling unit
Floor area more than 100 m2 upto 150m2
2.00 for every dwelling unit
Floor area above 150 m2
185 Substituted vide notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
186 Substituted vide notification No.21/1/TCP/2011/Part file/3252 dated 1-8-2011.
88–
II.
(a) Five & Four star hotels
One space for two rooms
(b) Other hotels and motels
One space for four rooms
III.
Cinemas, Theatres, Dance Halls, Public Assembly Halls
One space for floor area of 20 m2 or part thereof
IV.
Retail Business Markets including restaurants, office buildings, professional offices, banks, hospitals and nursing homes
One space for floor area of 50 m2 or part thereof
V.
Wholesale ware housing, wholesale market and market yards
Parking area of 50 m2 for floor area of 100 m2 or part thereof
VI.
Schools and Colleges
Parking area of 25 m2 for floor area of 100 m2 or part thereof
VII.
Industrial premises
Parking area of 50 m2 for floor area of 200 m2 or part thereof
VIII.
Stadia
Parking area of 50 m2 for 50 seats or part thereof
IX.
Retail markets
Parking area of 25 m2 for floor area of 100 m2 or part thereof]
(b) One off street parking space shall have the minimum area of 12.50 m2 (2.50 m x 5.00 m) and all parking spaces shall be provided with adequate vehicular circulation and maneuvering space from the street. Wherever areas of parking are as specified in the Table IX, these areas should not be converted into open spaces; the minimum being the one specified above and shall not include circulation space.
(c) The parking layout plan to be submitted with the application shall fulfill the following conditions:-
(a) The minimum width of the access to the street shall be 3.00 m and which shall be a no parking zone.
(b) The car parking area shall have two independent accesses leading to the street, if its capacity exceeds 19 parking spaces. However only one such access may be permitted if its minimum width is 5.00 meters and which shall be a no parking zone.
(d) Developments providing for off street parking in excess of the minimum requirements may be considered favorably by the Competent Authority for relaxation of other requirements.187[In no case F.A.R, coverage, height and setback shall be relaxed].
(e) The requirement of stilt parking on the ground floor, full or part, may be exempted, provided the builder/developer provides a separate structure only for parking within the same plot. The said structure shall be allowed free of FAR but shall be counted in the coverage and shall follow all other regulations in force.
(f) In case parking spaces are provided in the basement, at least two ramps of adequate width and slope shall be provided, located preferably at opposite end.188[However only one ramp may be permitted if the width of the ramp provided
187 Inserted vide notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
188 Inserted vide notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
89–
is at least 5.0 meters. Alternatively a car lift shall be provided in case provision of a ramp is not feasible.]
189{190[(g)] All new and renovated non-residential buildings and other residential buildings, Co-operative Housing Societies and Colonies managed by Residents Welfare Associations (RWAs), with parking demarcated for more than 10 equivalent car spaces (‗ECS‘) shall have atleast 20% of such ‗ECS‘ to be made ‗Electric Vehicle ready‘ ECS spots with conduits installed as per the GOA ELECTRIC MOBILITY PROMOTION POLICY – 2021 as amended from time to time.
Note: Independent house on single holding shall be exempted from the above regulation.}
11. Compound wall and gates.—
11.1. Permission for construction of compound wall and gates may be sought separately or alongwith the application for permission for construction/ /building operation/development within a plot. Detailed drawings of compound wall and gates shall be submitted alongwith the application for development permission drawn to a scale of 1 cm to 1 m.
11.2. Maximum height of a compound wall along the boundary other than that abutting on a street may be permitted up to a maximum height of 1.80 mts. and along the boundary abutting on a street up to a height of 1.50 mts. only and may be of closed type up to a height of 90 cms. only. However, no compound wall shall be permitted in front of commercial establishments existing/proposed in the building, unless separate entry and exit points are provided.
11.3. Compound wall, at street junctions shall be so located, as not to disturb the minimum sight distances as prescribed in these regulations and along the intersections of streets no compound wall shall be raised to a height of more than 1.00 mts. from the crown of the road for a length of 9.0 mts. From the intersection corner of the plot, on both sides of the plot.
11.4. In case of Government/Semi Government Blocks etc., which require special security requirements, mills, factories, industrial units, storage depots and warehouses, the compound wall may be allowed to be raised to a height not exceeding 3.0 mts. from the crown of the road, provided that no obstruction to the line of sight for traffic is caused.
11.5. All gates of compound wall shall open inward only, unless the gate is recessed into the plot to a depth, which will not cause the gate to protrude beyond the compound wall line.
11.6. The entry or exit, to the plot situated at the intersection of the roads having a width of 10.00 mts. or more, shall be located at least 15.00 mts. away from the tangent point of such intersection. If the length of any side of such a plot is less
189 Inserted vide Amendment Regulations, 2023.
190 Corrected vide Corrigendum No. 21/1/TCP/2021-23/Steering Committee/157 dated 3-11-2023.
90–
than what is prescribed above, then the entry or exit shall be provided at the farthest end of the plot from the intersection.
11.7. No barbed wire fence or cactus hedge shall be permitted along the boundaries abutting on a public road.
11.8. A sheet metal fence along the boundaries of a plot abutting a street or streets shall not be erected until the design thereof has been approved by the Licensing Authority.
11.9. No compound wall shall obstruct the right of way of the roads as prescribed in the designated plan/map and shall not block the traditional access passing through the property.
191[11.10. In case of industrial estates/industrial areas, the compound height shall be maximum 3.00 mts. With maximum construction height upto 2.00 mts. And barbed wire or chain linked for remaining 1.00 mt. subject to clearing of line of sight.]
Chapter 9Special Development/Structures.
9.1 Theatres and Stadia:
All buildings for Cinemas, Theatres including Motion Picture Houses, Exhibition Halls and other Public Assembly Buildings which come under Group-D-Classification of Building based on occupancy as per National Building Code of India shall conform with Fire & Life Safety as per Fire Protection (Part IV) Fire & Life Safety of National Building Code of India, 2005 as amended from time to time and shall conform to IS 4878-1986 for construction of Cinema Buildings (First Revision)(Reaffirmed in 1991) and Goa Cinematography Rules.
87–
12.2Regulations regarding surface and storm water drainage:
(a) All drains should have adequate slope to facilitate surface water drainage effectively.
(b) All drains should be constructed, lined, cemented and finished as per PWD specifications.
(c) All drains shall have minimum sizes as specified in Table X and should be constructed on one side for roads up to 6.0 m. R/W and on both sides for wider roads.
(d) Cross drains and culverts shall be provided as per site conditions wherever required and shall be either of pipes of minimum diameter of 300 mm. embedded in Plain Cement Concrete or RCC slab drain supported on laterite masonry with PCC lining at the bottom.
(e) All surface drains, storm water drains, cross drains and culverts should be clearly indicated in the sub-division plans indicating the route of flow of water along the proposed drains and its ultimate discharge on to public drains, public nallah or natural water courses.
195 Inserted vide notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
196 Substituted vide Notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
92–
(f) The open space/spaces left shall be provided with lined drains to drain out water in satisfactory manner as approved by the sanctioning authority.
(g) The sub-division plans should show the cross section and other construction details of the road drains, cross drains, culverts etc.
12.3Regulations regarding sloping sites:
(a) When submitting plans of sub-division of land or layout of private street proposals in a plot which has a gradient of 1:10 or more, the plan should indicate block levels at 5.00 m. centre to centre or alternatively contour plans at 1.00 m. intervals prepared by a Chartered Surveyor.
(b) The levels/contours should be drawn with reference to a bench mark clearly indicated on the site plan.
(c) Such block levels/contour plans prepared by a Chartered Surveyor are obligatory in case the site exceeds 10,000 m2 in area.
(d) No part of the plot which is having an inclination of more than 25% slope shall be permitted for development as useable 197[ ] plots. 198[This however shall not be applicable to the sub-divided plots already approved prior to the coming into force of these Regulations,]
12.1Regulations regarding roads:
(a) All road right of ways shall have the carriage widths and other widths specified in the following TABLE-X:
194[TABLE - X
Right of way (road width) in meters
6
8
10
15 with median
20 with median
Carriage width in meters
3.5
4.5
7
9 with median
12 with median
Shoulder/footpath width in meters
1.10 on each side
1.35 on each side
1.10 on each side
2.50 on each side
3.50 on each side
Width of road side drain in meters
0.30 on one side
0.40 +0.40
0.40+0.40
0.50+0.50
0.50+0.50].
191 Inserted vide Amendment Regulations, 2018.
192 Bracketed vide notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
193 Substituted vide notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
194 Substituted vide Amendment Regulations, 2018.
91–
(b) No roads shall have a gradient of more than 1:8 along its longitudinal section. 195[However, the same may be relaxed up to 1:6 for the length of a road not more than 100 meters in case construction of a road of lesser gradient is not possible, provided that road surface is constructed with higher specifications and with non-slippery surface material].
(c) All roads within the layout or sub-division shall be of water bound macadam with asphalt topping and shall follow the relevant P. W. D. specifications.
(d) All road corners should be worked out in a smooth curve of 3.00 m. radius for roads up to 10.00 m. R/W and that of 5.00 m. radius for roads above 10.00 m. R/W width (Refer Sketch No. 3 at Chapter 28).
(e) In case of road inter-sections involving roads of different R/W, the corners should be worked out as per the specifications prescribed for the road having wider R/W.
(f) All the cul-de-sac head provided shall have the minimum size of 12.00 meter X 12.00 meter shall touch the plot boundary to provide access to the adjacent properties. However, a 3.00 meter road serving a single plot may not be provided with a cul-de-sac head.
(g) 196[All sub-division roads shall be treated as deemed public roads unless the same are part of a co-operative housing or maintenance society or a gated community.]
12.4Regulations regarding open spaces:
(a) When a plot is to be sub-divided, certain areas shall be set apart as usable open space in the proportion given as detailed in TABLE- XI below. Further such open space provided in any sub-division of land shall not be further subdivided under these regulations.
199[Provided that the Goa Industrial Development Corporation may re-align, revise or reduce the open spaces maintained by it in any existing Industrial Estate or Industrial Area as per the standards specified in the Table below.]
TABLE-XI
Zone
Area to be sub-divided
Open space to be provided
S1, S2,
4000 m2 and
15%
S3, S4
above
C1, C2,
4000 m2
15%, out of which 10% is to be developed as recreational open
C3, C4,
and above
space and 5% as general pool parking which is open to sky and shall not be built upon.
P
4000 m2 and above
15%, out of which 10% is to be developed as recreational open space and 5% as general pool parking which is open to sky and shall not be built upon.
197Omitted vide notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
198Inserted vide notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
199 Inserted vided Amendment Regulations, 2020.
93–
²⁰⁰[I1, I2, I3]
10,000 m2 and above
15%, out of which 7.5% is to be developed as recreational open space and 7.50% as general pool parking which is open to sky and shall not be built upon.In GIDC developed industrial estates/industrial area, 7.5% of the total area shall be reserved for open space, out of which 2.5% shall be kept for recreational landscaping such as park/garden/tree plantation and 5% can be used for general utility like OHR, pump house, sump and general parking open to sky.]²⁰¹[The open space area that may be available to be released over and above the requirement of 7.5% of the total area shall be deemed to be zoned as industrial area.]
T
20,000 m2 and above
15%, out of which 10% is to be developed as recreational open space and 5% as general pool parking which is open to sky and shall not be built upon.
202[(b) The open spaces can be provided in more than one parcel. However, the area of each such parcel shall not be less than 500 square meters and the minimum length of any side shall not be less than 15.00 meters.
Further, in case of triangular open space/any open space having irregular shape, the minimum dimension shall be that of a circle, having 15 meters diameter, inscribed within such an irregular shape (refer sketch No. 7).]
(c) All open spaces shall have a means of access as though it is an independent plot.
203[(d) The open spaces shall be used for recreational and community purposes of the occupants of the sub-divided plots and/or for installations of public utilities, provided that such installations do not cover more than 5% of each of the open space or they may cover by combining the 5% of each of the various existing/proposed open space parcels within the existing/proposed sub-division layout and utilize in one bigger parcel of the existing/proposed sub-division open space, a minimum of 3.00 metre setback from all edges of the plot is kept and the maximum height of any construction is restricted to 6.00 m only. In case of water tower, the height restriction will not be applicable.]
(e) The open spaces shall be deemed to be zoned as zone ―R‖ and shall be governed by the following provisions:-
204[(i) The open spaces may be transferred to the local authority by a gift deed by the owner/developer before obtaining final approval. If the open spaces are transferred to the local authority the same shall be developed and maintained by such local authority for the purpose mentioned in sub-clause (d) above.
200 Substituted vide Amendment Regulations, 2018.
201 Added vided Amendment Regulations, 2020.
203Substituted vide Amendment Regulations, 2023.
202 Substituted vide notification No. 21/1/TCP/2015/Steering Comm/16/5145 dated 21-12-2016.
204Substituted vide notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
94–
However, purchasers of the plots shall be entitled to free access and use of the open spaces].
(ii) In case of Group Housing wherein open spaces are required to be kept, then, such open spaces shall be jointly held by the owners of the premises/ /Co-operative Housing Society. The owners of the premises or Co-operative Housing Society shall be deemed to have an undivided share in such open spaces proportionate to the area of their premises. Its use however shall remain unchanged as stipulated at sub-clause (d) above.
While enclosing the area by a compound 205[or boundary] wall, adequate provision shall be made to ensure that access is not obstructed to any adjoining] 206[property thereby making it a land locked property.]
(f) In commercial zones, if bye-lanes of width not less than 7.50 m. are provided adjoining public roads, to be used for parking, the area of such bye-lanes may be computed in the open space up to 50% of the total requirements of open space.
(g) In case of partial development of a plot, 15% open space should be set apart of only that part of the plot undertaken for development provided that this part of the plot as well as the remaining part is not less than 4000 m² in area.
(h) General pool parking provided in the regulations at Table XI shall be only of open to sky type and shall not be built upon.
12.5 General requirements regarding development of plots, open spaces and roads:
(a) All plots should be properly developed to make them suitable for construction and so as to prevent water logging.
(b) The roads and open spaces should be developed so as to prevent water logging and flooding.
(c) Every sub-divided plot as well as all open spaces should have an independent motorable means of access from a public road.
(d) All plots and open spaces shall be clearly demarcated with boundary stones fixed at all corners.
Sub-division regulations.—
The sub-division of land shall conform to the provisions given below regarding roads, surface and storm water drainage, sloping sites, open spaces, size of plots and their frontage and means of access.
These regulations shall be applicable to new sub-divisions in all zones 192[( , except in zones A1 & A2)], which shall be governed under ‗Other Regulations‘ at 193[12.7].
Provided that sub-division regulations regarding minimum size of plot, Frontage etc. shall not apply to the original plots having independent surveys No./chalta No. for the purpose of permitting any development within the plot in terms of zoning and land use provisions. Also appropriate provisions shall be made for garbage, sewerage, water supply, electric supply, telephone lines, cable television, etc. and other essential services as required in the Regulations.