4.1. Development to be in conformity with respective Acts/Rules/Regulations.— (a) Every development shall conform to the provisions of relevant Acts, Rules and Regulations and appropriate Plan in force and no development shall be carried out without obtaining prior permission from the Competent Authority in the manner prescribed under these Regulations.
(b) Every building operation or sub-division of land shall be subject to the following general regulations, wherever applicable and no land shall be used as a site for development—
(i) If the site is found to be liable to liquefaction by the Goa State Disaster Management Authority under the earthquake intensity of the area, in such case it shall be ensured that the building site is away from such areas and a safe distance as advised by Goa State Disaster Management Authority is followed except where appropriate protection measures are taken.
(ii) If the Goa State Disaster Management Authority finds that the proposed development falls in the area liable to storm surge during cyclone, in such case it shall be ensured that the building site is away from such areas and a safe distance as advised by Goa State Disaster Management Authority is followed except where protection measures are adopted to prevent storm surge damage.
(iii) In hilly terrain, the site plan should include location of landslide prone areas, if any indicated in Goa Disaster Management Plan, on or near the site, in such case it shall be ensured that the building site is away from such areas and a safe distance as advised by Goa State Disaster Management Authority is followed except where protection measures are adopted to prevent landslides.
(iv) The site plan on a sloping site may also include proposals for diversion of the natural flow of water coming from uphill side of the building away from the foundation.
(c) Roof pattern in buildings.— All buildings in residential zone should have sloping roof 109[of each building], flat type roof 110[of each building] may be permitted up to a maximum extent of 111[50%] of covered area of the building.
4.2. Means of access to the building within the plot.— (a) Every person who erects a building shall provide a means of access to such building a clear way of not less than 3.00 mts.
(b) Such pathway shall be kept open to sky and no projection or overhang shall be permitted over it except a canopy or a balcony or a weather board or a chajja erected at least 2.50 metres above the ground level.
(c) Steps, ottas or any raised platforms shall not be permitted in such pathway.
(d) Every such pathway shall be paved, drained and adequately lighted.
109 Inserted vide Notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
110 Inserted vide Notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
111 Substituted vide Notification No. 21/1/TCP/2011/Part file/3252 dated 1-8-2011.
49–
(e) Any person who undertakes construction work or a building shall not reduce the width of such pathway to building previously existing below the minimum requirements prescribed under these Regulations.
(f) In case of level differences, the pathway could be in form of steps or ramp from the road level to the entrances of the building. In case of steps, the tread of the step shall not be less than 30 cms. and riser shall not be more than 20 cms. In case of ramp the gradient shall be less than 1:6 for driveway and 1:12 for pathway. In case of steps, adequate parking shall be provided nearby.
112[(g) Every person who erects a building with no side setbacks or with 1.5 mts. setback (or less) on both the sides, shall provide a means of access to the rear of (through) such building within the property, a clear way of not less than 4.5 mts. in width for non-high rise buildings and 6 mts. in width for high rise buildings for entry of fire fighting vehicle. Such means of access is to be maintained free from any obstructions and at no time shall any portion of the building be allowed to project or overhang into the passage below the height of 4.5 mts. If arch or covered gate is constructed, it shall have a clear headroom of not less than 5 meters.
113[{For buildings having side and rear setbacks as per Regulation 4.4.2, Table IV, the means of access to the rear is not required to be maintained. However, for high rise buildings, means of access to the rear of minimum 6.0 mtrs. or applicable setbacks, whichever is higher, is required to be maintained at least on one side. Further, access to the rear shall not be applicable to the plots covered under the regulation 4.7.}]
(h) The applicant shall indicate upon the site plan required to be furnished by him, the whole area of such means of access by distinguishing in colour and description.
(i) The person who undertakes development of a plot shall not do so as to deprive any other plot of land of its means of access or easement and shall not reduce such means of access to a width less than 3.0 mts. Such access could be through set back areas subject to the condition that no projection shall be permitted within this access. The area of such access shall not be deducted while computing the effective area of the plot.
(j) The applicant shall not at any time erect or cause to permit to be erected or re-erect any building/structure even temporarily, which in any way encroaches or diminishes the area so set apart for the purpose of public or traditional access.
4.3. Restriction on development within line of sight at the road intersections.— No development including construction of buildings, compound walls, erection of hoarding, etc. shall be permitted within the line of sight, upto 4.5 mts. height from the level of adjoining roads. Any obstruction existing within the line of sight, natural or/and manmade, shall also have to be removed from line before applying for occupancy certificate.
Further, no development shall extend beyond the imaginary line drawn by joining two points on the adjacent edges of the right of ways of the roads at a distance from the point of intersection of the side of the corner of the effective plot as given in the TABLE-II.
112 Substituted vide Amendment Regulations, 2018.
113 Substituted vide Amendment Regulations, 2019.
50–
TABLE-II
(Refer Sketch No. 3 at Chapter 28)
| Right of way of road in meters | More than 30 | More than 20 upto 30 | More than 10 and upto 20 | Less than 10 |
|---|---|---|---|---|
| Distance from point of intersection in meters | 10.00 | 7.50 | 5.00 | 4.00 |