16.2 The above occupancies shall provide the following facilities, namely:—
(1) Every such building shall have easy access to the main entrance through a ramp with railing on both the sides as specified in clause (3).
(2) Every such building shall have a lift or separate approach through a ramp intended for persons with disabilities to each floor, provided that, the entrance door width for such lift shall not be less than 90 cm and its minimum size should be 1500 mm wide by 1500 mm deep; wherever possible 13 passenger lift to be provided, which allows easy maneuverability of wheel chair user, also the lift should have Braille marking on buttons inside and outside on the panels. It should have audio announcement, the lift should have railing on all three sides. In case lifts are provided with touch screen panel, there should be additional panel with physical button having Braille marking.
(3) The maximum gradient of any ramp approach intended for the persons with disabilities shall not exceed 1 in 12 (for details refer clause 7.2.2 of Harmonised
236 Regulation 16 substituted by Amendment Regulations, 2023.
129–
Guidelines and Space Standards for Barrier Free Built Environment for Persons with Disability and Elderly Persons) and shall be finished with non-slippery material. The minimum clear width of ramp shall be 120 cm. and provided with handrails on both sides at 80 cm. height. The slope of all such ramps shall be constant within a building as far as possible. The ramp also should carry tactile tiles as prescribed in the said Harmonised guidelines.
(4) Entrance Landing: Entrance landing shall be provided adjacent to ramp with the minimum dimension 1800mm x 2000mm. The entrance landing that adjoins the top end of a slope shall be provided with floor materials to attract the attention of visually impaired person‘s (limited to coloured floor material whose colour and brightness is conspicuously different from that of the surrounding floor material or the material that emits different sound to guide visually impaired persons. Finishes shall have a non-slip surface with a texture traversable by a wheel chair. Kerbs wherever provided should blend to a common level.
(5) Corridor connecting the entrance/exit for persons with disabilities: The corridor connecting the entrance/exit for persons with disabilities leading directly outdoors to a place where information concerning the overall use of the specified building can be provided to visually impaired persons either by a person or by signs, shall be provided as follows:
(a) Guiding floor materials shall be provided or device that emits sound to guide visually impaired persons should be installed.
(b) The minimum width shall be 1500mm.
(c) In case there is a difference of level, slope ways shall be provided with maximum slope of 1:12.
(d) Handrails shall be provided for ramps/slope ways on both the sides of stairways.
(6) Stair-ways: One of the stair-ways – near the entrance/exit for the persons with disabilities shall have the following provisions:
(a) The minimum width shall be 1350 mm.
(b) Height of the riser shall not be more than 150 mm and width of the tread 300mm. The steps shall not have abrupt (square) nosing.
(c) Maximum number of risers on a flight shall be limited to 12.
(d) Handrails shall be provided on both sides and shall extend 300 mm on the top and bottom of each flight of steps.