(7) (a) In all public buildings, one unisex accessible toilet should be provided in each toilet block in each floor. Apart from this all toilet blocks must have one cubicle suitable for use by persons with ambulatory disabilities.
130–
Note: (1) For small office buildings where the floor area limits the provision of accessible washrooms/toilets on each floor, one unisex accessible washroom on ground level shall be provided to serve the entire building. The unisex accessible washroom/toilet should be located adjacent to an accessible elevator.
Note: (2) Where an office building is sub-divided among various tenants, unisex accessible washroom/toilet should be provided on each floor.
(7) (b) The unisex toilet should have:-
(i) The minimum size shall be 2200mm x 2000mm.
(ii) Minimum clear opening of the door shall be 900mm and the door shall open outward or have two way opening door or a sliding type with a sliding/horizontal pull bar at least 600mm long.
(iii) The layout of the fixtures in the toilet should be such that there is a clear maneuvering space of 1800mm x 1800mm in front of water closet and wash basin in the accessible toilet unit.
(iv) Centre of WC shall be located at a distance of 460mm to 480mm from the adjacent wall.
(v) There should be an adequate clear floor space of atleast 1350mm depth and 900mm width both in front and on the transfer side, adjacent to water closet.
(vi) Suitable arrangement of vertical/horizontal handrails with atleast 50mm clearance from wall shall be made in toilet.
(vii) The top of WC seat shall be 450-480mm from the floor.
(viii) At least one sink (washbasin) in each floor shall have a knee room of 70 cms high under the sink and
(ix) Locks if any, of such toilet doors shall be of a type that can be opened from outside in case of emergency.
(7) (c) One special W.C. at each floor in a set of toilets shall be provided for the use of persons with disabilities with essential provision of washbasin near the entrance for the persons with disabilities.
(i) The minimum size shall be 900 x 2000 mm.
(ii) Minimum clear opening of the door shall be 900mm and the door shall open outward or have two way opening door or a sliding type with a sliding /horizontal pull bar at least 600mm long.
(iii) Suitable arrangement of vertical/horizontal handrails with minimum 50mm clearance from wall shall be made in the toilet.
(iv) The top of W.C. seat shall be 450-480mm from the floor.
131–
(v) At least one sink (washbasin) in each floor shall have a knee room of 70 cms high under the sink and 900mm width both in front and on the transfer side, adjacent to water closet.
(vi) Locks if any, of such toilet doors shall be of a type that can be opened from outside in case of emergency.
(8) Parking facilities:
(a) Two accessible parking lot should be provided for every 25 car parking spaces or part thereof exclusively for persons with disabilities with maximum travel distance of 30 meters from the building entrance.
(b) The width of such parking bay shall be minimum of 3.6 meters.
Specific sign boards should be available for notifying reserve parking for persons with disabilities in all building structures/recreational spaces specified in regulation 16.1.